Search criteria
20 vulnerabilities by wibu
CVE-2025-47809 (GCVE-0-2025-47809)
Vulnerability from cvelistv5 – Published: 2025-05-16 00:00 – Updated: 2025-05-16 13:36
VLAI?
Summary
Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.
Severity ?
8.2 (High)
CWE
- CWE-272 - Least Privilege Violation
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47809",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-16T13:35:54.604112Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-16T13:36:00.498Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CodeMeter",
"vendor": "Wibu",
"versions": [
{
"lessThan": "8.30a",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*",
"versionEndExcluding": "8.30a",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-272",
"description": "CWE-272 Least Privilege Violation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-16T00:18:40.444Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.wibu.com/support/security-advisories/wibu-100120.html"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-47809",
"datePublished": "2025-05-16T00:00:00.000Z",
"dateReserved": "2025-05-10T00:00:00.000Z",
"dateUpdated": "2025-05-16T13:36:00.498Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45181 (GCVE-0-2024-45181)
Vulnerability from cvelistv5 – Published: 2024-09-12 00:00 – Updated: 2024-09-12 19:49
VLAI?
Summary
An issue was discovered in WibuKey64.sys in WIBU-SYSTEMS WibuKey before v6.70 and fixed in v.6.70. An improper bounds check allows crafted packets to cause an arbitrary address write, resulting in kernel memory corruption.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:wibu:wibukey:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wibukey",
"vendor": "wibu",
"versions": [
{
"lessThan": "6.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-45181",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-12T19:41:43.007669Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T19:49:11.501Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in WibuKey64.sys in WIBU-SYSTEMS WibuKey before v6.70 and fixed in v.6.70. An improper bounds check allows crafted packets to cause an arbitrary address write, resulting in kernel memory corruption."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T18:23:55.651977",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://wibu.com"
},
{
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-94453.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-45181",
"datePublished": "2024-09-12T00:00:00",
"dateReserved": "2024-08-22T00:00:00",
"dateUpdated": "2024-09-12T19:49:11.501Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45182 (GCVE-0-2024-45182)
Vulnerability from cvelistv5 – Published: 2024-09-12 00:00 – Updated: 2024-10-29 20:14
VLAI?
Summary
An issue was discovered in WibuKey64.sys in WIBU-SYSTEMS WibuKey before v6.70 and fixed in v.6.70 An improper bounds check allows specially crafted packets to cause an arbitrary address read, resulting in Denial of Service.
Severity ?
5.5 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:wibu:wibukey:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "wibukey",
"vendor": "wibu",
"versions": [
{
"lessThan": "6.70",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-45182",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-12T19:36:05.663302Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "CWE-404 Improper Resource Shutdown or Release",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-29T20:14:05.302Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in WibuKey64.sys in WIBU-SYSTEMS WibuKey before v6.70 and fixed in v.6.70 An improper bounds check allows specially crafted packets to cause an arbitrary address read, resulting in Denial of Service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-12T18:24:54.445902",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://wibu.com"
},
{
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-94453.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-45182",
"datePublished": "2024-09-12T00:00:00",
"dateReserved": "2024-08-22T00:00:00",
"dateUpdated": "2024-10-29T20:14:05.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3935 (GCVE-0-2023-3935)
Vulnerability from cvelistv5 – Published: 2023-09-13 13:19 – Updated: 2025-08-27 20:32
VLAI?
Summary
A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system.
Severity ?
9.8 (Critical)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Wibu | CodeMeter Runtime |
Affected:
0.0 , ≤ 7.60b
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:08:50.775Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-031/"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2023-030/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3935",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T21:50:55.835781Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T20:32:53.842Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CodeMeter Runtime",
"vendor": "Wibu",
"versions": [
{
"lessThanOrEqual": "7.60b",
"status": "affected",
"version": "0.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "CodeMeter Runtime",
"vendor": "Wibu",
"versions": [
{
"status": "unaffected",
"version": "7.21g"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system."
}
],
"value": "A heap buffer overflow vulnerability in Wibu CodeMeter Runtime network service up to version 7.60b allows an unauthenticated, remote attacker to achieve RCE and gain full access of the host system."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-19T07:00:20.911Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/AdvisoryWIBU-230704-01-v3.0.pdf"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-031/"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2023-030/"
}
],
"source": {
"defect": [
"CERT@VDE#64566"
],
"discovery": "UNKNOWN"
},
"title": "Wibu: Buffer Overflow in CodeMeter Runtime",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2023-3935",
"datePublished": "2023-09-13T13:19:18.392Z",
"dateReserved": "2023-07-25T13:02:40.206Z",
"dateUpdated": "2025-08-27T20:32:53.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-41057 (GCVE-0-2021-41057)
Vulnerability from cvelistv5 – Published: 2021-11-14 20:21 – Updated: 2024-08-04 02:59
VLAI?
Summary
In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T02:59:31.383Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.wibu.com/us/support/security-advisories.html"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-14T20:21:30",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.wibu.com/us/support/security-advisories.html"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41057",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.wibu.com/us/support/security-advisories.html",
"refsource": "MISC",
"url": "https://www.wibu.com/us/support/security-advisories.html"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf"
},
{
"name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf",
"refsource": "CONFIRM",
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41057",
"datePublished": "2021-11-14T20:21:30",
"dateReserved": "2021-09-13T00:00:00",
"dateUpdated": "2024-08-04T02:59:31.383Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20094 (GCVE-0-2021-20094)
Vulnerability from cvelistv5 – Published: 2021-06-16 11:09 – Updated: 2024-08-03 17:30
VLAI?
Summary
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.
Severity ?
No CVSS data available.
CWE
- Uncaught Exception
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Wibu-Systems CodeMeter |
Affected:
< 7.21a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.586Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-24"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wibu-Systems CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "\u003c 7.21a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Uncaught Exception",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-05T20:12:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-24"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20094",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wibu-Systems CodeMeter",
"version": {
"version_data": [
{
"version_value": "\u003c 7.21a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-24",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-24"
},
{
"name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf",
"refsource": "MISC",
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20094",
"datePublished": "2021-06-16T11:09:07",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.586Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20093 (GCVE-0-2021-20093)
Vulnerability from cvelistv5 – Published: 2021-06-16 11:09 – Updated: 2024-08-03 17:30
VLAI?
Summary
A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server.
Severity ?
No CVSS data available.
CWE
- Buffer Over-read
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Wibu-Systems CodeMeter |
Affected:
< 7.21a
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.515Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-24"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Wibu-Systems CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "\u003c 7.21a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer Over-read",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-05T20:11:49",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-24"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2021-20093",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Wibu-Systems CodeMeter",
"version": {
"version_data": [
{
"version_value": "\u003c 7.21a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer Over-read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-24",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-24"
},
{
"name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf",
"refsource": "MISC",
"url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2021-20093",
"datePublished": "2021-06-16T11:09:02",
"dateReserved": "2020-12-17T00:00:00",
"dateUpdated": "2024-08-03T17:30:07.515Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-16233 (GCVE-0-2020-16233)
Vulnerability from cvelistv5 – Published: 2020-09-16 19:51 – Updated: 2024-08-04 13:37
VLAI?
Summary
An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.
Severity ?
No CVSS data available.
CWE
- CWE-404 - IMPROPER RESOURCE SHUTDOWN OR RELEASE CWE-404
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:37:53.590Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 7.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "IMPROPER RESOURCE SHUTDOWN OR RELEASE CWE-404",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-16T19:51:20",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-16233",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CodeMeter",
"version": {
"version_data": [
{
"version_value": "All versions prior to 7.10"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER RESOURCE SHUTDOWN OR RELEASE CWE-404"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-16233",
"datePublished": "2020-09-16T19:51:20",
"dateReserved": "2020-07-31T00:00:00",
"dateUpdated": "2024-08-04T13:37:53.590Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-14513 (GCVE-0-2020-14513)
Vulnerability from cvelistv5 – Published: 2020-09-16 19:49 – Updated: 2024-08-04 12:46
VLAI?
Summary
CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields.
Severity ?
No CVSS data available.
CWE
- CWE-20 - IMPROPER INPUT VALIDATION CWE-20
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.696Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 6.81"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "IMPROPER INPUT VALIDATION CWE-20",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-16T19:49:37",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14513",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CodeMeter",
"version": {
"version_data": [
{
"version_value": "All versions prior to 6.81"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CodeMeter (All versions prior to 6.81) and the software using it may crash while processing a specifically crafted license file due to unverified length fields."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER INPUT VALIDATION CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14513",
"datePublished": "2020-09-16T19:49:37",
"dateReserved": "2020-06-19T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.696Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-14515 (GCVE-0-2020-14515)
Vulnerability from cvelistv5 – Published: 2020-09-16 19:48 – Updated: 2024-08-04 12:46
VLAI?
Summary
CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected.
Severity ?
No CVSS data available.
CWE
- CWE-347 - IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.789Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-347",
"description": "IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-16T19:48:08",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14515",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CodeMeter",
"version": {
"version_data": [
{
"version_value": "All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CodeMeter (All versions prior to 6.90 when using CmActLicense update files with CmActLicense Firm Code) has an issue in the license-file signature checking mechanism, which allows attackers to build arbitrary license files, including forging a valid license file as if it were a valid license file of an existing vendor. Only CmActLicense update files with CmActLicense Firm Code are affected."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14515",
"datePublished": "2020-09-16T19:48:08",
"dateReserved": "2020-06-19T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.789Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-14519 (GCVE-0-2020-14519)
Vulnerability from cvelistv5 – Published: 2020-09-16 19:44 – Updated: 2024-08-04 12:46
VLAI?
Summary
This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515.
Severity ?
No CVSS data available.
CWE
- CWE-346 - ORIGIN VALIDATION ERROR CWE-346
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.665Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 7.00, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-346",
"description": "ORIGIN VALIDATION ERROR CWE-346",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-16T19:44:16",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14519",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CodeMeter",
"version": {
"version_data": [
{
"version_value": "All versions prior to 7.00, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows an attacker to use the internal WebSockets API for CodeMeter (All versions prior to 7.00 are affected, including Version 7.0 or newer with the affected WebSockets API still enabled. This is especially relevant for systems or devices where a web browser is used to access a web server) via a specifically crafted Java Script payload, which may allow alteration or creation of license files for when combined with CVE-2020-14515."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "ORIGIN VALIDATION ERROR CWE-346"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14519",
"datePublished": "2020-09-16T19:44:16",
"dateReserved": "2020-06-19T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-14517 (GCVE-0-2020-14517)
Vulnerability from cvelistv5 – Published: 2020-09-16 19:42 – Updated: 2024-08-04 12:46
VLAI?
Summary
Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API.
Severity ?
No CVSS data available.
CWE
- CWE-326 - INADEQUATE ENCRYPTION STRENGTH CWE-326
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.990Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 6.90, including Version 6.90 or newer only if CodeMeter Runtime is running as server."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "INADEQUATE ENCRYPTION STRENGTH CWE-326",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-16T19:42:12",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14517",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CodeMeter",
"version": {
"version_data": [
{
"version_value": "All versions prior to 6.90, including Version 6.90 or newer only if CodeMeter Runtime is running as server."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Protocol encryption can be easily broken for CodeMeter (All versions prior to 6.90 are affected, including Version 6.90 or newer only if CodeMeter Runtime is running as server) and the server accepts external connections, which may allow an attacker to remotely communicate with the CodeMeter API."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "INADEQUATE ENCRYPTION STRENGTH CWE-326"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14517",
"datePublished": "2020-09-16T19:42:12",
"dateReserved": "2020-06-19T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.990Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-14509 (GCVE-0-2020-14509)
Vulnerability from cvelistv5 – Published: 2020-09-16 19:39 – Updated: 2024-08-04 12:46
VLAI?
Summary
Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities.
Severity ?
No CVSS data available.
CWE
- CWE-805 - BUFFER ACCESS WITH INCORRECT LENGTH VALUE CWE-805
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.701Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CodeMeter",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "All versions prior to 7.10"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-805",
"description": "BUFFER ACCESS WITH INCORRECT LENGTH VALUE CWE-805",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-16T19:39:02",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14509",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CodeMeter",
"version": {
"version_data": [
{
"version_value": "All versions prior to 7.10"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple memory corruption vulnerabilities exist in CodeMeter (All versions prior to 7.10) where the packet parser mechanism does not verify length fields. An attacker could send specially crafted packets to exploit these vulnerabilities."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "BUFFER ACCESS WITH INCORRECT LENGTH VALUE CWE-805"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-203-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14509",
"datePublished": "2020-09-16T19:39:02",
"dateReserved": "2020-06-19T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.701Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-3990 (GCVE-0-2018-3990)
Vulnerability from cvelistv5 – Published: 2019-02-05 22:00 – Updated: 2024-08-05 04:57
VLAI?
Summary
An exploitable pool corruption vulnerability exists in the 0x8200E804 IOCTL handler functionality of WIBU-SYSTEMS WibuKey.sys Version 6.40 (Build 2400). A specially crafted IRP request can cause a buffer overflow, resulting in kernel memory corruption and, potentially, privilege escalation. An attacker can send an IRP request to trigger this vulnerability.
Severity ?
9.3 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T04:57:24.697Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107005",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107005"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0658"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-01-28T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An exploitable pool corruption vulnerability exists in the 0x8200E804 IOCTL handler functionality of WIBU-SYSTEMS WibuKey.sys Version 6.40 (Build 2400). A specially crafted IRP request can cause a buffer overflow, resulting in kernel memory corruption and, potentially, privilege escalation. An attacker can send an IRP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T18:07:38",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "107005",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107005"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0658"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2018-3990",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An exploitable pool corruption vulnerability exists in the 0x8200E804 IOCTL handler functionality of WIBU-SYSTEMS WibuKey.sys Version 6.40 (Build 2400). A specially crafted IRP request can cause a buffer overflow, resulting in kernel memory corruption and, potentially, privilege escalation. An attacker can send an IRP request to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 9.3,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107005",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107005"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0658",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0658"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2018-3990",
"datePublished": "2019-02-05T22:00:00",
"dateReserved": "2018-01-02T00:00:00",
"dateUpdated": "2024-08-05T04:57:24.697Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-3991 (GCVE-0-2018-3991)
Vulnerability from cvelistv5 – Published: 2019-02-05 22:00 – Updated: 2024-08-05 04:57
VLAI?
Summary
An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability.
Severity ?
10 (Critical)
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T04:57:24.691Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107005",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107005"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-01-28T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T18:07:39",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "107005",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107005"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2018-3991",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 10,
"baseSeverity": null,
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107005",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107005"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0659"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2018-3991",
"datePublished": "2019-02-05T22:00:00",
"dateReserved": "2018-01-02T00:00:00",
"dateUpdated": "2024-08-05T04:57:24.691Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-3989 (GCVE-0-2018-3989)
Vulnerability from cvelistv5 – Published: 2019-02-05 22:00 – Updated: 2024-08-05 04:57
VLAI?
Summary
An exploitable kernel memory disclosure vulnerability exists in the 0x8200E804 IOCTL handler functionality of WIBU-SYSTEMS WibuKey.sys Version 6.40 (Build 2400).A specially crafted IRP request can cause the driver to return uninitialized memory, resulting in kernel memory disclosure. An attacker can send an IRP request to trigger this vulnerability.
Severity ?
4.3 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T04:57:24.561Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "107005",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/107005"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0657"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2018-01-28T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "An exploitable kernel memory disclosure vulnerability exists in the 0x8200E804 IOCTL handler functionality of WIBU-SYSTEMS WibuKey.sys Version 6.40 (Build 2400).A specially crafted IRP request can cause the driver to return uninitialized memory, resulting in kernel memory disclosure. An attacker can send an IRP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T18:07:37",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "107005",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/107005"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0657"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2018-3989",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An exploitable kernel memory disclosure vulnerability exists in the 0x8200E804 IOCTL handler functionality of WIBU-SYSTEMS WibuKey.sys Version 6.40 (Build 2400).A specially crafted IRP request can cause the driver to return uninitialized memory, resulting in kernel memory disclosure. An attacker can send an IRP request to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 4.3,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "107005",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/107005"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0657",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2018-0657"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844562.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-760124.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2018-3989",
"datePublished": "2019-02-05T22:00:00",
"dateReserved": "2018-01-02T00:00:00",
"dateUpdated": "2024-08-05T04:57:24.561Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-13754 (GCVE-0-2017-13754)
Vulnerability from cvelistv5 – Published: 2017-09-07 13:00 – Updated: 2024-08-05 19:05
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in the "advanced settings - time server" module in Wibu-Systems CodeMeter before 6.50b allows remote attackers to inject arbitrary web script or HTML via the "server name" field in actions/ChangeConfiguration.html.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T19:05:19.996Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2074"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1073133"
},
{
"name": "20170904 Wibu Systems AG CodeMeter 6.50 - Persistent XSS Vulnerability",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "http://www.securityfocus.com/archive/1/541119/100/0/threaded"
},
{
"name": "20170904 Wibu Systems AG CodeMeter 6.50 - Persistent XSS Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2017/Sep/1"
},
{
"name": "104433",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/104433"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-102-02"
},
{
"name": "42610",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/42610/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-09-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in the \"advanced settings - time server\" module in Wibu-Systems CodeMeter before 6.50b allows remote attackers to inject arbitrary web script or HTML via the \"server name\" field in actions/ChangeConfiguration.html."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-09T18:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.vulnerability-lab.com/get_content.php?id=2074"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1073133"
},
{
"name": "20170904 Wibu Systems AG CodeMeter 6.50 - Persistent XSS Vulnerability",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "http://www.securityfocus.com/archive/1/541119/100/0/threaded"
},
{
"name": "20170904 Wibu Systems AG CodeMeter 6.50 - Persistent XSS Vulnerability",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2017/Sep/1"
},
{
"name": "104433",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/104433"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-102-02"
},
{
"name": "42610",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/42610/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-13754",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in the \"advanced settings - time server\" module in Wibu-Systems CodeMeter before 6.50b allows remote attackers to inject arbitrary web script or HTML via the \"server name\" field in actions/ChangeConfiguration.html."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.vulnerability-lab.com/get_content.php?id=2074",
"refsource": "MISC",
"url": "https://www.vulnerability-lab.com/get_content.php?id=2074"
},
{
"name": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1073133",
"refsource": "CONFIRM",
"url": "https://rockwellautomation.custhelp.com/app/answers/detail/a_id/1073133"
},
{
"name": "20170904 Wibu Systems AG CodeMeter 6.50 - Persistent XSS Vulnerability",
"refsource": "BUGTRAQ",
"url": "http://www.securityfocus.com/archive/1/541119/100/0/threaded"
},
{
"name": "20170904 Wibu Systems AG CodeMeter 6.50 - Persistent XSS Vulnerability",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2017/Sep/1"
},
{
"name": "104433",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/104433"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-102-02",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-102-02"
},
{
"name": "42610",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/42610/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-13754",
"datePublished": "2017-09-07T13:00:00",
"dateReserved": "2017-08-29T00:00:00",
"dateUpdated": "2024-08-05T19:05:19.996Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2014-8419 (GCVE-0-2014-8419)
Vulnerability from cvelistv5 – Published: 2014-11-26 15:00 – Updated: 2024-08-06 13:18
VLAI?
Summary
Wibu-Systems CodeMeter Runtime before 5.20 uses weak permissions (read and write access for all users) for codemeter.exe, which allows local users to gain privileges via a Trojan horse file.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T13:18:48.164Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/129234/CodeMeter-Weak-Service-Permissions.html"
},
{
"name": "20141124 CVE-2014-8419 - CodeMeter Weak Service Permissions",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "http://www.securityfocus.com/archive/1/534079/100/0/threaded"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2014-11-24T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Wibu-Systems CodeMeter Runtime before 5.20 uses weak permissions (read and write access for all users) for codemeter.exe, which allows local users to gain privileges via a Trojan horse file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-09T18:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/129234/CodeMeter-Weak-Service-Permissions.html"
},
{
"name": "20141124 CVE-2014-8419 - CodeMeter Weak Service Permissions",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "http://www.securityfocus.com/archive/1/534079/100/0/threaded"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2014-8419",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Wibu-Systems CodeMeter Runtime before 5.20 uses weak permissions (read and write access for all users) for codemeter.exe, which allows local users to gain privileges via a Trojan horse file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://packetstormsecurity.com/files/129234/CodeMeter-Weak-Service-Permissions.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/129234/CodeMeter-Weak-Service-Permissions.html"
},
{
"name": "20141124 CVE-2014-8419 - CodeMeter Weak Service Permissions",
"refsource": "BUGTRAQ",
"url": "http://www.securityfocus.com/archive/1/534079/100/0/threaded"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2014-8419",
"datePublished": "2014-11-26T15:00:00",
"dateReserved": "2014-10-22T00:00:00",
"dateUpdated": "2024-08-06T13:18:48.164Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-4057 (GCVE-0-2011-4057)
Vulnerability from cvelistv5 – Published: 2012-01-13 18:00 – Updated: 2024-09-16 16:43
VLAI?
Summary
Wibu-Systems AG CodeMeter Runtime 4.30c, 4.10b, and possibly other versions before 4.40 allows remote attackers to cause a denial of service (CodeMeter.exe crash) via certain crafted packets to TCP port 22350.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:53:32.604Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "78223",
"tags": [
"vdb-entry",
"x_refsource_OSVDB",
"x_transferred"
],
"url": "http://osvdb.org/78223"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8MYNFL"
},
{
"name": "51382",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51382"
},
{
"name": "VU#659515",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/659515"
},
{
"name": "JVN#78901873",
"tags": [
"third-party-advisory",
"x_refsource_JVN",
"x_transferred"
],
"url": "http://jvn.jp/en/jp/JVN78901873/index.html"
},
{
"name": "JVNDB-2012-000003",
"tags": [
"third-party-advisory",
"x_refsource_JVNDB",
"x_transferred"
],
"url": "http://jvndb.jvn.jp/ja/contents/2012/JVNDB-2012-000003.html"
},
{
"name": "47497",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/47497"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Wibu-Systems AG CodeMeter Runtime 4.30c, 4.10b, and possibly other versions before 4.40 allows remote attackers to cause a denial of service (CodeMeter.exe crash) via certain crafted packets to TCP port 22350."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-01-13T18:00:00Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"name": "78223",
"tags": [
"vdb-entry",
"x_refsource_OSVDB"
],
"url": "http://osvdb.org/78223"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/MAPG-8MYNFL"
},
{
"name": "51382",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51382"
},
{
"name": "VU#659515",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/659515"
},
{
"name": "JVN#78901873",
"tags": [
"third-party-advisory",
"x_refsource_JVN"
],
"url": "http://jvn.jp/en/jp/JVN78901873/index.html"
},
{
"name": "JVNDB-2012-000003",
"tags": [
"third-party-advisory",
"x_refsource_JVNDB"
],
"url": "http://jvndb.jvn.jp/ja/contents/2012/JVNDB-2012-000003.html"
},
{
"name": "47497",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/47497"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-4057",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Wibu-Systems AG CodeMeter Runtime 4.30c, 4.10b, and possibly other versions before 4.40 allows remote attackers to cause a denial of service (CodeMeter.exe crash) via certain crafted packets to TCP port 22350."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "78223",
"refsource": "OSVDB",
"url": "http://osvdb.org/78223"
},
{
"name": "http://www.kb.cert.org/vuls/id/MAPG-8MYNFL",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/MAPG-8MYNFL"
},
{
"name": "51382",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51382"
},
{
"name": "VU#659515",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/659515"
},
{
"name": "JVN#78901873",
"refsource": "JVN",
"url": "http://jvn.jp/en/jp/JVN78901873/index.html"
},
{
"name": "JVNDB-2012-000003",
"refsource": "JVNDB",
"url": "http://jvndb.jvn.jp/ja/contents/2012/JVNDB-2012-000003.html"
},
{
"name": "47497",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/47497"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2011-4057",
"datePublished": "2012-01-13T18:00:00Z",
"dateReserved": "2011-10-13T00:00:00Z",
"dateUpdated": "2024-09-16T16:43:55.949Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-3689 (GCVE-0-2011-3689)
Vulnerability from cvelistv5 – Published: 2011-09-27 19:00 – Updated: 2024-09-16 16:28
VLAI?
Summary
Cross-site scripting (XSS) vulnerability in Licenses.html in Wibu-Systems CodeMeter WebAdmin 3.30 and 4.30 allows remote attackers to inject arbitrary web script or HTML via the BoxSerial parameter.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:46:02.611Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.solutionary.com/index/SERT/Vuln-Disclosures/CodeMeter-WebAdmin.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting (XSS) vulnerability in Licenses.html in Wibu-Systems CodeMeter WebAdmin 3.30 and 4.30 allows remote attackers to inject arbitrary web script or HTML via the BoxSerial parameter."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2011-09-27T19:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.solutionary.com/index/SERT/Vuln-Disclosures/CodeMeter-WebAdmin.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-3689",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site scripting (XSS) vulnerability in Licenses.html in Wibu-Systems CodeMeter WebAdmin 3.30 and 4.30 allows remote attackers to inject arbitrary web script or HTML via the BoxSerial parameter."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.solutionary.com/index/SERT/Vuln-Disclosures/CodeMeter-WebAdmin.html",
"refsource": "MISC",
"url": "http://www.solutionary.com/index/SERT/Vuln-Disclosures/CodeMeter-WebAdmin.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-3689",
"datePublished": "2011-09-27T19:00:00Z",
"dateReserved": "2011-09-23T00:00:00Z",
"dateUpdated": "2024-09-16T16:28:26.648Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}