Action not permitted
Modal body text goes here.
cve-2021-20094
Vulnerability from cvelistv5
Published
2021-06-16 11:09
Modified
2024-08-03 17:30
Severity ?
EPSS score ?
Summary
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.
References
▼ | URL | Tags | |
---|---|---|---|
vulnreport@tenable.com | https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf | Mitigation, Vendor Advisory | |
vulnreport@tenable.com | https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf | Patch, Third Party Advisory | |
vulnreport@tenable.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02 | Third Party Advisory, US Government Resource | |
vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2021-24 | Exploit, Patch, Third Party Advisory |
Impacted products
▼ | Vendor | Product |
---|---|---|
n/a | Wibu-Systems CodeMeter |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T17:30:07.586Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Wibu-Systems CodeMeter", "vendor": "n/a", "versions": [ { "status": "affected", "version": "\u003c 7.21a" } ] } ], "descriptions": [ { "lang": "en", "value": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server." } ], "problemTypes": [ { "descriptions": [ { "description": "Uncaught Exception", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-05T20:12:10", "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "shortName": "tenable" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20094", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Wibu-Systems CodeMeter", "version": { "version_data": [ { "version_value": "\u003c 7.21a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Uncaught Exception" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-24", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf", "refsource": "MISC", "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be", "assignerShortName": "tenable", "cveId": "CVE-2021-20094", "datePublished": "2021-06-16T11:09:07", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-08-03T17:30:07.586Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-20094\",\"sourceIdentifier\":\"vulnreport@tenable.com\",\"published\":\"2021-06-16T12:15:12.073\",\"lastModified\":\"2022-05-13T17:30:28.603\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.\"},{\"lang\":\"es\",\"value\":\"Se presenta una vulnerabilidad de denegaci\u00f3n de servicio en las de Wibu-Systems CodeMeter versiones anteriores a 7.21a. Un atacante remoto no autenticado puede explotar este problema para bloquear el CodeMeter Runtime Server\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.21a\",\"matchCriteriaId\":\"E4D83EED-5237-4A45-82AA-5370A6B9D0D9\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:pss_cape:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"890BA38B-38CD-4B6D-96E8-A786CFFE4C35\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sicam_230:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"702949EB-ED2D-4E85-802B-93EEA4FA939E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sicam_230_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ACC0968E-7082-4FBF-AEC0-91B280DA2A8C\"}]}]}],\"references\":[{\"url\":\"https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2021-24\",\"source\":\"vulnreport@tenable.com\",\"tags\":[\"Exploit\",\"Patch\",\"Third Party Advisory\"]}]}}" } }
icsa-23-320-03
Vulnerability from csaf_cisa
Published
2023-11-14 00:00
Modified
2023-11-14 00:00
Summary
Siemens Desigo CC product family
Notes
Summary
Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS) are affected by multiple vulnerabilities in the underlying third-party component WIBU Systems CodeMeter Runtime.
Successful exploitation of these vulnerabilities could allow remote attackers to execute arbitrary code on the Desigo CC server, or create a denial of service condition.
While all verison lines V5.0, V5.1 and V6 are affected by all listed vulnerabilities, V7 is only affected by CVE-2023-3935.
Siemens has released a patch to update the CodeMeter Runtime component and recommends to apply the patch on affected systems.
General Recommendations
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Versions V5.0 through V7 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS) are affected by multiple vulnerabilities in the underlying third-party component WIBU Systems CodeMeter Runtime.\nSuccessful exploitation of these vulnerabilities could allow remote attackers to execute arbitrary code on the Desigo CC server, or create a denial of service condition.\nWhile all verison lines V5.0, V5.1 and V6 are affected by all listed vulnerabilities, V7 is only affected by CVE-2023-3935.\n\nSiemens has released a patch to update the CodeMeter Runtime component and recommends to apply the patch on affected systems.", "title": "Summary" }, { "category": "general", "text": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-625850.json" }, { "category": "self", "summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-625850.html" }, { "category": "self", "summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-625850.pdf" }, { "category": "self", "summary": "SSA-625850: Multiple WIBU Systems CodeMeter Vulnerabilities Affecting the Desigo CC Product Family - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-625850.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-320-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-320-03 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Desigo CC product family", "tracking": { "current_release_date": "2023-11-14T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-320-03", "initial_release_date": "2023-11-14T00:00:00Z", "revision_history": [ { "date": "2023-11-14T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Desigo CC product family V5.0", "product_id": "1" } } ], "category": "product_name", "name": "Desigo CC product family V5.0" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Desigo CC product family V5.1", "product_id": "2" } } ], "category": "product_name", "name": "Desigo CC product family V5.1" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Desigo CC product family V6", "product_id": "3" } } ], "category": "product_name", "name": "Desigo CC product family V6" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Desigo CC product family V7", "product_id": "4" } } ], "category": "product_name", "name": "Desigo CC product family V7" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-20093", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.\n\nAn unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "vendor_fix", "details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-20093" }, { "cve": "CVE-2021-20094", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash.\n\nAn unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3" ] }, "remediations": [ { "category": "vendor_fix", "details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions", "product_ids": [ "1", "2", "3" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3" ] } ], "title": "CVE-2021-20094" }, { "cve": "CVE-2023-3935", "cwe": { "id": "CWE-122", "name": "Heap-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "In CodeMeter Runtime versions up to 7.60b, there is a heap buffer overflow vulnerability which can potentially lead to a remote code execution. Currently, no PoC is known to us. To\r\nexploit the heap overflow, additional protection mechanisms need to be broken. Remote access is only possible if CodeMeter is configured as a server. If CodeMeter is not configured as a server, the adversary would need to log in to the machine where the CodeMeter Runtime is running or trick the user into sending a malicious request to CodeMeter. This might result in an escalation of privilege. (WIBU-230704-01)", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4" ] }, "remediations": [ { "category": "vendor_fix", "details": "Install the patch (available at \nhttps://support.industry.siemens.com/cs/ww/en/view/109825787/), which can be applied to all released versions", "product_ids": [ "1", "2", "3", "4" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.0, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4" ] } ], "title": "CVE-2023-3935" } ] }
icsa-21-210-02
Vulnerability from csaf_cisa
Published
2021-07-29 00:00
Modified
2021-07-29 00:00
Summary
Wibu-Systems CodeMeter Runtime
Notes
CISA Disclaimer
This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Risk evaluation
Successful exploitation of these vulnerabilities could allow an attacker to read data from the heap of the CodeMeter Runtime network server, or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Exploitability
No known public exploits specifically target these vulnerabilities.
{ "document": { "acknowledgments": [ { "organization": "Tenable, Inc", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to read data from the heap of the CodeMeter Runtime network server, or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-675303: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-675303.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-210-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-210-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-210-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-210-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-675303: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "category": "external", "summary": "SSA-675303: WIBU Systems CodeMeter Runtime Vulnerabilities in Siemens Products - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-675303.txt" } ], "title": "Wibu-Systems CodeMeter Runtime", "tracking": { "current_release_date": "2021-07-29T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-210-02", "initial_release_date": "2021-07-29T00:00:00.000000Z", "revision_history": [ { "date": "2021-07-29T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-210-02 WIBU Systems CodeMeter Runtime" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "CAPE 14 installations installed from material dated earlier than 2021-06-16", "product": { "name": "PSS(R)CAPE", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "PSS(R)CAPE" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SICAM 230", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "SICAM 230" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= 2019 SP1 \u003c 2020 Upd1", "product": { "name": "SIMATIC Information Server", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "SIMATIC Information Server" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.1", "product": { "name": "SIMATIC PCS neo", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "SIMATIC PCS neo" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= 2019 \u003c 2020 Upd1", "product": { "name": "SIMATIC Process Historian (incl. Process Historian OPC UA Server)", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "SIMATIC Process Historian (incl. Process Historian OPC UA Server)" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.17 P013", "product": { "name": "SIMATIC WinCC OA V3.17", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.17" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.18 P002", "product": { "name": "SIMATIC WinCC OA V3.18", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "SIMATIC WinCC OA V3.18" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= V10.0 \u003c V10.3 Upd 1", "product": { "name": "SIMIT Simulation Platform", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "SIMIT Simulation Platform" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V1.0.1 Update 1", "product": { "name": "SINEC INS", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "SINEC INS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V3.0 SP2", "product": { "name": "SINEMA Remote Connect Server", "product_id": "CSAFPID-00010" } } ], "category": "product_name", "name": "SINEMA Remote Connect Server" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-20093", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A buffer over-read vulnerability in the CodeMeter Runtime network server could cause the server to return packets containing data from the heap.\n\nAn unauthenticated remote attacker could exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010" ] }, "references": [ { "summary": "CVE-2021-20093 - SIMATIC WinCC OA V3.17", "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "summary": "CVE-2021-20093 - SIMATIC WinCC OA V3.18", "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "summary": "CVE-2021-20093 - SIMIT Simulation Platform", "url": "https://support.industry.siemens.com/cs/ww/en/view/109800638/" }, { "summary": "CVE-2021-20093 - SINEC INS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109806100/" }, { "summary": "CVE-2021-20093 - SINEMA Remote Connect Server", "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790/" }, { "summary": "CVE-2021-20093 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-20093.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-20093" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "CAPE 14 installations installed from material dated 2021-06-16 or later are not affected, as they contain a fixed version of CodeMeter Runtime.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "If CAPE 14 was initially installed using earlier material, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.psscape.com/codemeter and install it the same way as documented for previous versions in the PSS CAPE 14 Installation Manual. Contact PSS(R)CAPE Support at psscape.support.energy@siemens.com if you need assistance with patching affected systems.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Installations of PSS(R)CAPE are only affected if network access to CodeMeter Runtime is enabled. This is not the default configuration and is not necessary for any functionality in PSS(R)CAPE.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Update SICAM 230 to V8.00 or later version. Then update CodeMeter Runtime to V7.21a or V7.30a: Download the package from: https://www.wibu.com/us/support/user/downloads-user-software.html. Install it on SICAM 230 systems according to the procedure documented in chapter 9.2 of the COPA-DATA Security Vulnerability Announcement 2021_1: https://www.copadata.com/fileadmin/user_upload/faq/files/CD_SVA_2021_1.pdf.", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "vendor_fix", "details": "Update SIMATIC PCS neo to V3.1 or later version", "product_ids": [ "CSAFPID-0003", "CSAFPID-0005" ] }, { "category": "mitigation", "details": "Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running.", "product_ids": [ "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005" ] }, { "category": "vendor_fix", "details": "Update to V3.1 or later version", "product_ids": [ "CSAFPID-0004" ] }, { "category": "vendor_fix", "details": "Update to V3.17 P013 or later version", "product_ids": [ "CSAFPID-0006" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "mitigation", "details": "Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running (for details refer to the updated security manual of WinCC OA).", "product_ids": [ "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "vendor_fix", "details": "Update to V3.18 P002 or later version", "product_ids": [ "CSAFPID-0007" ], "url": "https://www.winccoa.com/downloads/category/versions-patches.html" }, { "category": "vendor_fix", "details": "Update to V10.3 Upd1 or later version", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800638/" }, { "category": "vendor_fix", "details": "Alternatively, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.wibu.com/us/support/user/downloads-user-software.html and follow the installation instructions from WIBU Systems.", "product_ids": [ "CSAFPID-0008" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109800638/" }, { "category": "vendor_fix", "details": "Update to V1.0.1 Update 1 or later version", "product_ids": [ "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109806100/" }, { "category": "vendor_fix", "details": "Alternatively, update CodeMeter Runtime to V7.21a: Download the package \"CodeMeter User Runtime for Linux, version 7.21a, Driver-only\" from the WIBU Systems User Software website. Install it on the system which runs SINEC INS by executing the following command:\n\n\"sudo dpkg --force-depends --force-confnew -i codemeter-7.21.4611.501_amd64.deb\"", "product_ids": [ "CSAFPID-0009" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109806100/" }, { "category": "mitigation", "details": "Limit remote access to port 22350/tcp on systems where the Codemeter runtime network server is running. Note that this is the default configuration, which therefore limits the exploitability to local attacks only.", "product_ids": [ "CSAFPID-0009", "CSAFPID-00010" ] }, { "category": "vendor_fix", "details": "Update to V3.0 SP2 or later version", "product_ids": [ "CSAFPID-00010" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109793790/" }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010" ] } ], "scores": [ { "cvss_v3": { "baseScore": 9.1, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009", "CSAFPID-00010" ] } ], "title": "CVE-2021-20093" }, { "cve": "CVE-2021-20094", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "A buffer over-read vulnerability in the HTTP(S) service of the CodeMeter Runtime CmWAN server could cause the server to crash.\n\nAn unauthenticated remote attacker with access to the CmWAN port could exploit this issue to crash the CodeMeter Runtime Server (i.e., CodeMeter.exe).", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-20094 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-20094.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-20094" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "CAPE 14 installations installed from material dated 2021-06-16 or later are not affected, as they contain a fixed version of CodeMeter Runtime.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "If CAPE 14 was initially installed using earlier material, install WIBU Systems CodeMeter Runtime V7.21a or V7.30a manually to fix the issue: Download the package from https://www.psscape.com/codemeter and install it the same way as documented for previous versions in the PSS CAPE 14 Installation Manual. Contact PSS(R)CAPE Support at psscape.support.energy@siemens.com if you need assistance with patching affected systems.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Installations of PSS(R)CAPE are only affected if network access to CodeMeter Runtime is enabled. This is not the default configuration and is not necessary for any functionality in PSS(R)CAPE.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Update SICAM 230 to V8.00 or later version. Then update CodeMeter Runtime to V7.21a or V7.30a: Download the package from: https://www.wibu.com/us/support/user/downloads-user-software.html. Install it on SICAM 230 systems according to the procedure documented in chapter 9.2 of the COPA-DATA Security Vulnerability Announcement 2021_1: https://www.copadata.com/fileadmin/user_upload/faq/files/CD_SVA_2021_1.pdf.", "product_ids": [ "CSAFPID-0002" ] }, { "category": "no_fix_planned", "details": "Currently no remediation is planned", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-20094" } ] }
ghsa-fm8v-xp26-8h3q
Vulnerability from github
Published
2022-05-24 19:05
Modified
2022-05-24 19:05
Severity ?
Details
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.
{ "affected": [], "aliases": [ "CVE-2021-20094" ], "database_specific": { "cwe_ids": [ "CWE-125" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-06-16T12:15:00Z", "severity": "HIGH" }, "details": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.", "id": "GHSA-fm8v-xp26-8h3q", "modified": "2022-05-24T19:05:32Z", "published": "2022-05-24T19:05:32Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-20094" }, { "type": "WEB", "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "type": "WEB", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" }, { "type": "WEB", "url": "https://www.tenable.com/security/research/tra-2021-24" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "type": "CVSS_V3" } ] }
var-202106-0817
Vulnerability from variot
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server. Wibu-Systems CodeMeter Exists in an out-of-bounds read vulnerability.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202106-0817", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sicam 230", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "codemeter", "scope": "lt", "trust": 1.0, "vendor": "wibu", "version": "7.21a" }, { "model": "pss cape", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "codemeter", "scope": "eq", "trust": 0.8, "vendor": "wibu", "version": null }, { "model": "codemeter", "scope": "eq", "trust": 0.8, "vendor": "wibu", "version": "7.21a" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "NVD", "id": "CVE-2021-20094" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.21a", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:pss_cape:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sicam_230_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sicam_230:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-20094" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "reported these vulnerabilities to CISA., Inc.,Tenable", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-1303" } ], "trust": 0.6 }, "cve": "CVE-2021-20094", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-20094", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-20094", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-20094", "trust": 1.8, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202106-1303", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-20094", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-20094" }, { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "NVD", "id": "CVE-2021-20094" }, { "db": "CNNVD", "id": "CNNVD-202106-1303" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server. Wibu-Systems CodeMeter Exists in an out-of-bounds read vulnerability.Service operation interruption (DoS) It may be in a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-20094" }, { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-20094" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-20094", "trust": 3.3 }, { "db": "TENABLE", "id": "TRA-2021-24", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-21-210-02", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-675303", "trust": 1.7 }, { "db": "JVN", "id": "JVNVU92598492", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU99583134", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-320-03", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-002246", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021073002", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.2575", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202106-1303", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-20094", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-20094" }, { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "NVD", "id": "CVE-2021-20094" }, { "db": "CNNVD", "id": "CNNVD-202106-1303" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "id": "VAR-202106-0817", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.5009009 }, "last_update_date": "2023-12-18T11:41:04.961000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "WIBU-210423-02", "trust": 0.8, "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/advisory_wibu-210423-02.pdf" }, { "title": "Wibu-Systems CodeMeter Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=155295" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=a38962f28ac4b7e355a2146c756f2b6d" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-20094" }, { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "CNNVD", "id": "CNNVD-202106-1303" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-125", "trust": 1.0 }, { "problemtype": "Out-of-bounds read (CWE-125) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "NVD", "id": "CVE-2021-20094" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "trust": 2.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" }, { "trust": 1.7, "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/advisory_wibu-210423-02.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu99583134/index.html" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu92598492/index.html" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20094" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-320-03" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/wibu-systems-codemeter-denial-of-service-via-http-35869" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.2575" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021073002" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/125.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://cert-portal.siemens.com/productcert/txt/ssa-675303.txt" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-20094" }, { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "NVD", "id": "CVE-2021-20094" }, { "db": "CNNVD", "id": "CNNVD-202106-1303" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-20094" }, { "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "db": "NVD", "id": "CVE-2021-20094" }, { "db": "CNNVD", "id": "CNNVD-202106-1303" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-16T00:00:00", "db": "VULMON", "id": "CVE-2021-20094" }, { "date": "2021-08-03T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "date": "2021-06-16T12:15:12.073000", "db": "NVD", "id": "CVE-2021-20094" }, { "date": "2021-06-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-1303" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-13T00:00:00", "db": "VULMON", "id": "CVE-2021-20094" }, { "date": "2023-11-21T01:45:00", "db": "JVNDB", "id": "JVNDB-2021-002246" }, { "date": "2022-05-13T17:30:28.603000", "db": "NVD", "id": "CVE-2021-20094" }, { "date": "2021-08-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-1303" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-1303" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Wibu-Systems\u00a0CodeMeter\u00a0 Out-of-bounds read vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-002246" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-1303" } ], "trust": 0.6 } }
gsd-2021-20094
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
A denial of service vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-20094", "description": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.", "id": "GSD-2021-20094" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-20094" ], "details": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server.", "id": "GSD-2021-20094", "modified": "2023-12-13T01:23:12.190241Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20094", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Wibu-Systems CodeMeter", "version": { "version_data": [ { "version_value": "\u003c 7.21a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Uncaught Exception" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2021-24", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf", "refsource": "MISC", "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:wibu:codemeter:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.21a", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:pss_cape:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:sicam_230_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:sicam_230:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "vulnreport@tenable.com", "ID": "CVE-2021-20094" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A denial of service vulnerability exists in Wibu-Systems CodeMeter versions \u003c 7.21a. An unauthenticated remote attacker can exploit this issue to crash the CodeMeter Runtime Server." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-125" } ] } ] }, "references": { "reference_data": [ { "name": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf", "refsource": "MISC", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-02.pdf" }, { "name": "https://www.tenable.com/security/research/tra-2021-24", "refsource": "MISC", "tags": [ "Exploit", "Patch", "Third Party Advisory" ], "url": "https://www.tenable.com/security/research/tra-2021-24" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02", "refsource": "MISC", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2022-05-13T17:30Z", "publishedDate": "2021-06-16T12:15Z" } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.