Search criteria

15 vulnerabilities found for r189_one-net_eas by monroe_electronics

FKIE_CVE-2013-4735

Vulnerability from fkie_nvd - Published: 2013-06-30 19:28 - Updated: 2025-04-11 00:51

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5A9D54-20F6-4791-A830-3E6635A18933",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "308B32AD-1091-4528-964B-7394D54B1D4E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC044FA-0BC2-43D4-BF32-9B6FD67B8E77",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "90C5BDD8-C91B-44EB-870E-FABEFCFA5F7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
    },
    {
      "lang": "es",
      "value": "El dispositivo Digital Alert Systems DASDEC EAS anterior a v2.0-2 y el dispositivo Monroe Electronics R189 One-Net EAS anterior a v2.0-2 tener una contrase\u00f1a por defecto para una cuenta administrativa, lo que hace que sea m\u00e1s f\u00e1cil para un atacante remoto para obtener acceso a trav\u00e9s de una red IP."
    }
  ],
  "id": "CVE-2013-4735",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-06-30T19:28:11.277",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-264"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-4732

Vulnerability from fkie_nvd - Published: 2013-06-30 19:28 - Updated: 2025-04-11 00:51
Severity ?
Summary
The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A6190CC-FD4E-4CF2-81CE-9E108EF4B7B4",
              "versionEndIncluding": "2.0-2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "308B32AD-1091-4528-964B-7394D54B1D4E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:2.0-1:*:*:*:*:*:*:*",
              "matchCriteriaId": "0F56C2F8-B2EC-4A96-898A-EAD3D02B7A6C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03F1A7BA-78B3-4ED0-947D-2CADF4A981D9",
              "versionEndIncluding": "2.0-2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "90C5BDD8-C91B-44EB-870E-FABEFCFA5F7B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:2.0-1:*:*:*:*:*:*:*",
              "matchCriteriaId": "72D48CEF-FD5C-4547-A1A6-7FBF509AA12A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [
    {
      "sourceIdentifier": "cve@mitre.org",
      "tags": [
        "disputed"
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
    },
    {
      "lang": "es",
      "value": "** EN DISPUTA ** El servidor Web de administraci\u00f3n del dispositivo Digital Alert Systems DASDEC EAS hasta v2.0-2 y el dispositivo Monroe Electronics R189 One-Net hasta v2.0-2 use un ID de sesi\u00f3n predecible, lo que permite a los atacantes remotos secuestrar la sesi\u00f3n de los usuarios mediante  EAS utiliza valores de ID de sesi\u00f3n predecibles, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes remotos secuestrar sesiones mediante la captura de datos de red (\"sniffing\"). NOTA: VU#662676 dice que. Monroe Electronics no puede reproducir este hallazgo\""
    }
  ],
  "id": "CVE-2013-4732",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-06-30T19:28:10.173",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-255"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-4734

Vulnerability from fkie_nvd - Published: 2013-06-30 19:28 - Updated: 2025-04-11 00:51
Severity ?
Summary
dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5A9D54-20F6-4791-A830-3E6635A18933",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "308B32AD-1091-4528-964B-7394D54B1D4E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC044FA-0BC2-43D4-BF32-9B6FD67B8E77",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "90C5BDD8-C91B-44EB-870E-FABEFCFA5F7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
    },
    {
      "lang": "es",
      "value": "dasdec_mkuser en el dispositivo Digital Alert Systems DASDEC EAS anterior a v2.0-2 y el dispositivo Monroe Electronics R189 One-Net EAS anterior a v2.0-2 genera contrase\u00f1as previsibles, lo que podr\u00eda hacer m\u00e1s f\u00e1cil para los atacantes obtengan acceso no administrativo a trav\u00e9s de vectores no especificados."
    }
  ],
  "id": "CVE-2013-4734",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-06-30T19:28:10.923",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-4733

Vulnerability from fkie_nvd - Published: 2013-06-30 19:28 - Updated: 2025-04-11 00:51

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5A9D54-20F6-4791-A830-3E6635A18933",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "308B32AD-1091-4528-964B-7394D54B1D4E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC044FA-0BC2-43D4-BF32-9B6FD67B8E77",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "90C5BDD8-C91B-44EB-870E-FABEFCFA5F7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
    },
    {
      "lang": "es",
      "value": "El servidor web en el dispositivo Digital Alert Systems DASDEC EAS anterior a v2.0-2 y el dispositivo Monroe Electronics R189 One-Net EAS anterior a v2.0-2 permite a atacantes remotos obtener informaci\u00f3n sensible e informaci\u00f3n sobre el estado mediante la lectura de ficheros de log."
    }
  ],
  "id": "CVE-2013-4733",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 7.8,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-06-30T19:28:10.550",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-264"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-0137

Vulnerability from fkie_nvd - Published: 2013-06-30 19:28 - Updated: 2025-04-11 00:51
Severity ?
Summary
The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5A9D54-20F6-4791-A830-3E6635A18933",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:digital_alert_systems:dasdec_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "308B32AD-1091-4528-964B-7394D54B1D4E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC044FA-0BC2-43D4-BF32-9B6FD67B8E77",
              "versionEndIncluding": "2.0-1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:monroe_electronics:r189_one-net_eas:2.0-0:*:*:*:*:*:*:*",
              "matchCriteriaId": "90C5BDD8-C91B-44EB-870E-FABEFCFA5F7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
    },
    {
      "lang": "es",
      "value": "La configuraci\u00f3n por defecto del dispositivo  Digital Alert Systems DASDEC EAS hasta v2.0-2 y el dispositivo Monroe Electronics R189 One-Net hasta v2.0-2 contiene un clave SSH privada conocida, lo que hace que sea m\u00e1s f\u00e1cil para un atacante remoto obtener acceso como root y  falsificar alertas, a trav\u00e9s de una sesi\u00f3n SSH."
    }
  ],
  "id": "CVE-2013-0137",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-06-30T19:28:09.593",
  "references": [
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "cret@cert.org",
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "cret@cert.org",
      "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/662676"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-310"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2013-4732 (GCVE-0-2013-4732)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-16 17:54
VLAI?
Summary
The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.001Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        }
      ],
      "tags": [
        "disputed"
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4732",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "** DISPUTED ** The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding.\""
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "MISC",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "MISC",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "MISC",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "MISC",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4732",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-16T17:54:12.663Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-0137 (GCVE-0-2013-0137)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-08-06 14:18
VLAI?
Summary
The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:18:09.572Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-06-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-29T17:01:40",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2013-0137",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/",
              "refsource": "MISC",
              "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2013-0137",
    "datePublished": "2013-06-29T21:00:00",
    "dateReserved": "2012-12-06T00:00:00",
    "dateUpdated": "2024-08-06T14:18:09.572Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4735 (GCVE-0-2013-4735)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 02:57
VLAI?
Summary
The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.034Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4735",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4735",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T02:57:08.864Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4733 (GCVE-0-2013-4733)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 04:04
VLAI?
Summary
The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:26.967Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4733",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4733",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T04:04:17.436Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4734 (GCVE-0-2013-4734)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 01:31
VLAI?
Summary
dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.167Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4734",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4734",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T01:31:37.062Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4732 (GCVE-0-2013-4732)

Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-16 17:54
VLAI?
Summary
The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.001Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        }
      ],
      "tags": [
        "disputed"
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4732",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "** DISPUTED ** The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding.\""
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "MISC",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "MISC",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "MISC",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "MISC",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4732",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-16T17:54:12.663Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-0137 (GCVE-0-2013-0137)

Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-08-06 14:18
VLAI?
Summary
The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:18:09.572Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-06-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-29T17:01:40",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2013-0137",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/",
              "refsource": "MISC",
              "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2013-0137",
    "datePublished": "2013-06-29T21:00:00",
    "dateReserved": "2012-12-06T00:00:00",
    "dateUpdated": "2024-08-06T14:18:09.572Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4735 (GCVE-0-2013-4735)

Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-17 02:57
VLAI?
Summary
The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.034Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4735",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4735",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T02:57:08.864Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4733 (GCVE-0-2013-4733)

Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-17 04:04
VLAI?
Summary
The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:26.967Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4733",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4733",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T04:04:17.436Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4734 (GCVE-0-2013-4734)

Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-17 01:31
VLAI?
Summary
dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.167Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4734",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4734",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T01:31:37.062Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}