Search criteria

15 vulnerabilities found for sel-451_firmware by selinc

FKIE_CVE-2023-34389

Vulnerability from fkie_nvd - Published: 2023-11-30 17:15 - Updated: 2024-11-21 08:07
Summary
An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time. See product Instruction Manual Appendix A dated 20230830 for more details.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "567CA071-8A2D-40DD-A3DF-0FD73739476F",
              "versionEndExcluding": "r315-v4",
              "versionStartIncluding": "r315-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE50B5EC-2A69-4EA9-A16D-5A0BF38D2861",
              "versionEndExcluding": "r316-v4",
              "versionStartIncluding": "r316-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9D6B6F3-8D35-46B5-879C-26F22ED4AA2D",
              "versionEndExcluding": "r317-v4",
              "versionStartIncluding": "r317-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DC6FE46-8B20-47D6-8A88-1708978C49D1",
              "versionEndExcluding": "r318-v5",
              "versionStartIncluding": "r318-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E3E5B0A-E01A-4A5B-894C-DF83E4E5B23F",
              "versionEndExcluding": "r320-v3",
              "versionStartIncluding": "r320-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7505AF51-82AF-4145-B794-CA0B5048DD7E",
              "versionEndExcluding": "r321-v3",
              "versionStartIncluding": "r321-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F092F10-4440-4FC4-8B0B-44B86F1742B8",
              "versionEndExcluding": "r322-v3",
              "versionStartIncluding": "r322-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B80DF635-298D-45B6-A5F7-71386587E6A8",
              "versionEndExcluding": "r323-v5",
              "versionStartIncluding": "r323-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E9473AE-F0E1-49A2-BD2E-CEAC21B5CF9C",
              "versionEndExcluding": "r324-v4",
              "versionStartIncluding": "r324-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77E42746-C95B-476B-8734-0DE9FA1C611C",
              "versionEndExcluding": "r325-v3",
              "versionStartIncluding": "r325-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r326-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF1EF31-FFF7-4A3B-8A9F-2BD4CC355CD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r327-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C7EDD0-52E2-45E7-975C-B194F2902F5D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:selinc:sel-451:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BBDB9B5-DAF0-4A78-88E3-1EB6486F8A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Una asignaci\u00f3n de recursos sin l\u00edmites o vulnerabilidad de limitaci\u00f3n en Schweitzer Engineering Laboratories SEL-451 podr\u00eda permitir que un atacante autenticado remoto haga que el sistema no est\u00e9 disponible por un per\u00edodo de tiempo indefinido. Consulte el Ap\u00e9ndice A del Manual de instrucciones del producto con fecha 20230830 para obtener m\u00e1s detalles."
    }
  ],
  "id": "CVE-2023-34389",
  "lastModified": "2024-11-21T08:07:09.403",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 4.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.6,
        "source": "security@selinc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T17:15:09.380",
  "references": [
    {
      "source": "security@selinc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "security@selinc.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    }
  ],
  "sourceIdentifier": "security@selinc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "security@selinc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-770"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-34388

Vulnerability from fkie_nvd - Published: 2023-11-30 17:15 - Updated: 2024-11-21 08:07
Summary
An Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "567CA071-8A2D-40DD-A3DF-0FD73739476F",
              "versionEndExcluding": "r315-v4",
              "versionStartIncluding": "r315-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE50B5EC-2A69-4EA9-A16D-5A0BF38D2861",
              "versionEndExcluding": "r316-v4",
              "versionStartIncluding": "r316-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9D6B6F3-8D35-46B5-879C-26F22ED4AA2D",
              "versionEndExcluding": "r317-v4",
              "versionStartIncluding": "r317-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DC6FE46-8B20-47D6-8A88-1708978C49D1",
              "versionEndExcluding": "r318-v5",
              "versionStartIncluding": "r318-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E3E5B0A-E01A-4A5B-894C-DF83E4E5B23F",
              "versionEndExcluding": "r320-v3",
              "versionStartIncluding": "r320-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7505AF51-82AF-4145-B794-CA0B5048DD7E",
              "versionEndExcluding": "r321-v3",
              "versionStartIncluding": "r321-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F092F10-4440-4FC4-8B0B-44B86F1742B8",
              "versionEndExcluding": "r322-v3",
              "versionStartIncluding": "r322-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B80DF635-298D-45B6-A5F7-71386587E6A8",
              "versionEndExcluding": "r323-v5",
              "versionStartIncluding": "r323-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E9473AE-F0E1-49A2-BD2E-CEAC21B5CF9C",
              "versionEndExcluding": "r324-v4",
              "versionStartIncluding": "r324-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77E42746-C95B-476B-8734-0DE9FA1C611C",
              "versionEndExcluding": "r325-v3",
              "versionStartIncluding": "r325-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r326-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF1EF31-FFF7-4A3B-8A9F-2BD4CC355CD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r327-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C7EDD0-52E2-45E7-975C-B194F2902F5D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:selinc:sel-451:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BBDB9B5-DAF0-4A78-88E3-1EB6486F8A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An\u00a0Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de autenticaci\u00f3n incorrecta en Schweitzer Engineering Laboratories SEL-451 podr\u00eda permitir que un atacante remoto no autenticado realice potencialmente un ataque de secuestro de sesi\u00f3n y omita la autenticaci\u00f3n. Consulte el Ap\u00e9ndice A del Manual de instrucciones del producto con fecha 20230830 para obtener m\u00e1s detalles."
    }
  ],
  "id": "CVE-2023-34388",
  "lastModified": "2024-11-21T08:07:09.263",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "security@selinc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T17:15:09.133",
  "references": [
    {
      "source": "security@selinc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "security@selinc.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    }
  ],
  "sourceIdentifier": "security@selinc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "security@selinc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-34390

Vulnerability from fkie_nvd - Published: 2023-11-30 17:15 - Updated: 2024-11-21 08:07
Summary
An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services. See product Instruction Manual Appendix A dated 20230830 for more details.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "567CA071-8A2D-40DD-A3DF-0FD73739476F",
              "versionEndExcluding": "r315-v4",
              "versionStartIncluding": "r315-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE50B5EC-2A69-4EA9-A16D-5A0BF38D2861",
              "versionEndExcluding": "r316-v4",
              "versionStartIncluding": "r316-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9D6B6F3-8D35-46B5-879C-26F22ED4AA2D",
              "versionEndExcluding": "r317-v4",
              "versionStartIncluding": "r317-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DC6FE46-8B20-47D6-8A88-1708978C49D1",
              "versionEndExcluding": "r318-v5",
              "versionStartIncluding": "r318-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E3E5B0A-E01A-4A5B-894C-DF83E4E5B23F",
              "versionEndExcluding": "r320-v3",
              "versionStartIncluding": "r320-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7505AF51-82AF-4145-B794-CA0B5048DD7E",
              "versionEndExcluding": "r321-v3",
              "versionStartIncluding": "r321-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F092F10-4440-4FC4-8B0B-44B86F1742B8",
              "versionEndExcluding": "r322-v3",
              "versionStartIncluding": "r322-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B80DF635-298D-45B6-A5F7-71386587E6A8",
              "versionEndExcluding": "r323-v5",
              "versionStartIncluding": "r323-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E9473AE-F0E1-49A2-BD2E-CEAC21B5CF9C",
              "versionEndExcluding": "r324-v4",
              "versionStartIncluding": "r324-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77E42746-C95B-476B-8734-0DE9FA1C611C",
              "versionEndExcluding": "r325-v3",
              "versionStartIncluding": "r325-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r326-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF1EF31-FFF7-4A3B-8A9F-2BD4CC355CD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r327-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C7EDD0-52E2-45E7-975C-B194F2902F5D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:selinc:sel-451:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BBDB9B5-DAF0-4A78-88E3-1EB6486F8A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de validaci\u00f3n de entrada en Schweitzer Engineering Laboratories SEL-451 podr\u00eda permitir que un atacante autenticado remoto cree una denegaci\u00f3n de servicio contra el sistema y bloquee los servicios. Consulte el Ap\u00e9ndice A del Manual de instrucciones del producto con fecha 20230830 para obtener m\u00e1s detalles."
    }
  ],
  "id": "CVE-2023-34390",
  "lastModified": "2024-11-21T08:07:09.550",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 4.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.6,
        "source": "security@selinc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T17:15:09.570",
  "references": [
    {
      "source": "security@selinc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "security@selinc.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    }
  ],
  "sourceIdentifier": "security@selinc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "security@selinc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-31176

Vulnerability from fkie_nvd - Published: 2023-11-30 17:15 - Updated: 2024-11-21 08:01
Summary
An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.  See product Instruction Manual Appendix A dated 20230830 for more details.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "567CA071-8A2D-40DD-A3DF-0FD73739476F",
              "versionEndExcluding": "r315-v4",
              "versionStartIncluding": "r315-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE50B5EC-2A69-4EA9-A16D-5A0BF38D2861",
              "versionEndExcluding": "r316-v4",
              "versionStartIncluding": "r316-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9D6B6F3-8D35-46B5-879C-26F22ED4AA2D",
              "versionEndExcluding": "r317-v4",
              "versionStartIncluding": "r317-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DC6FE46-8B20-47D6-8A88-1708978C49D1",
              "versionEndExcluding": "r318-v5",
              "versionStartIncluding": "r318-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E3E5B0A-E01A-4A5B-894C-DF83E4E5B23F",
              "versionEndExcluding": "r320-v3",
              "versionStartIncluding": "r320-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7505AF51-82AF-4145-B794-CA0B5048DD7E",
              "versionEndExcluding": "r321-v3",
              "versionStartIncluding": "r321-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F092F10-4440-4FC4-8B0B-44B86F1742B8",
              "versionEndExcluding": "r322-v3",
              "versionStartIncluding": "r322-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B80DF635-298D-45B6-A5F7-71386587E6A8",
              "versionEndExcluding": "r323-v5",
              "versionStartIncluding": "r323-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E9473AE-F0E1-49A2-BD2E-CEAC21B5CF9C",
              "versionEndExcluding": "r324-v4",
              "versionStartIncluding": "r324-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77E42746-C95B-476B-8734-0DE9FA1C611C",
              "versionEndExcluding": "r325-v3",
              "versionStartIncluding": "r325-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r326-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF1EF31-FFF7-4A3B-8A9F-2BD4CC355CD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r327-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C7EDD0-52E2-45E7-975C-B194F2902F5D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:selinc:sel-451:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BBDB9B5-DAF0-4A78-88E3-1EB6486F8A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.\u00a0\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n\n"
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de entrop\u00eda insuficiente en Schweitzer Engineering Laboratories SEL-451 podr\u00eda permitir que un atacante remoto no autenticado utilice tokens de sesi\u00f3n de fuerza bruta y eluda la autenticaci\u00f3n. Consulte el Ap\u00e9ndice A del Manual de instrucciones del producto con fecha 20230830 para obtener m\u00e1s detalles."
    }
  ],
  "id": "CVE-2023-31176",
  "lastModified": "2024-11-21T08:01:33.903",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "security@selinc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T17:15:08.520",
  "references": [
    {
      "source": "security@selinc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "security@selinc.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    }
  ],
  "sourceIdentifier": "security@selinc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-331"
        }
      ],
      "source": "security@selinc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-331"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-31177

Vulnerability from fkie_nvd - Published: 2023-11-30 17:15 - Updated: 2024-11-21 08:01
Summary
An Improper Neutralization of Input During Web Page Generation  ('Cross-site Scripting') in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for more details.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "567CA071-8A2D-40DD-A3DF-0FD73739476F",
              "versionEndExcluding": "r315-v4",
              "versionStartIncluding": "r315-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE50B5EC-2A69-4EA9-A16D-5A0BF38D2861",
              "versionEndExcluding": "r316-v4",
              "versionStartIncluding": "r316-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9D6B6F3-8D35-46B5-879C-26F22ED4AA2D",
              "versionEndExcluding": "r317-v4",
              "versionStartIncluding": "r317-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DC6FE46-8B20-47D6-8A88-1708978C49D1",
              "versionEndExcluding": "r318-v5",
              "versionStartIncluding": "r318-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E3E5B0A-E01A-4A5B-894C-DF83E4E5B23F",
              "versionEndExcluding": "r320-v3",
              "versionStartIncluding": "r320-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7505AF51-82AF-4145-B794-CA0B5048DD7E",
              "versionEndExcluding": "r321-v3",
              "versionStartIncluding": "r321-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F092F10-4440-4FC4-8B0B-44B86F1742B8",
              "versionEndExcluding": "r322-v3",
              "versionStartIncluding": "r322-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B80DF635-298D-45B6-A5F7-71386587E6A8",
              "versionEndExcluding": "r323-v5",
              "versionStartIncluding": "r323-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E9473AE-F0E1-49A2-BD2E-CEAC21B5CF9C",
              "versionEndExcluding": "r324-v4",
              "versionStartIncluding": "r324-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77E42746-C95B-476B-8734-0DE9FA1C611C",
              "versionEndExcluding": "r325-v3",
              "versionStartIncluding": "r325-v0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r326-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8EF1EF31-FFF7-4A3B-8A9F-2BD4CC355CD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:selinc:sel-451_firmware:r327-v0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9C7EDD0-52E2-45E7-975C-B194F2902F5D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:selinc:sel-451:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BBDB9B5-DAF0-4A78-88E3-1EB6486F8A13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Improper Neutralization of Input During Web Page Generation\u00a0 (\u0027Cross-site Scripting\u0027) in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim\u0027s system.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
    },
    {
      "lang": "es",
      "value": "Una neutralizaci\u00f3n inadecuada de la entrada durante la generaci\u00f3n de p\u00e1ginas web (\"Cross-site Scripting\") en Schweitzer Engineering Laboratories SEL-451 podr\u00eda permitir a un atacante crear un enlace que podr\u00eda ejecutar c\u00f3digo arbitrario en el sistema de una v\u00edctima. Consulte el Ap\u00e9ndice A del Manual de instrucciones del producto con fecha 20230830 para obtener m\u00e1s detalles."
    }
  ],
  "id": "CVE-2023-31177",
  "lastModified": "2024-11-21T08:01:34.057",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 4.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.9,
        "impactScore": 3.4,
        "source": "security@selinc.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-11-30T17:15:08.763",
  "references": [
    {
      "source": "security@selinc.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "security@selinc.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://selinc.com/support/security-notifications/external-reports/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.nozominetworks.com/blog/"
    }
  ],
  "sourceIdentifier": "security@selinc.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "security@selinc.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2023-34390 (GCVE-0-2023-34390)

Vulnerability from cvelistv5 – Published: 2023-11-30 16:54 – Updated: 2024-08-02 16:10
VLAI?
Title
Improper input validation could lead to denial of service
Summary
An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-20 - Improper Input Validation
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:06.673Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-25",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-25 Forced Deadlock"
            }
          ]
        },
        {
          "capecId": "CAPEC-469",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-469 HTTP DoS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:54:54.190Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": " Improper input validation could lead to denial of service",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-34390",
    "datePublished": "2023-11-30T16:54:54.190Z",
    "dateReserved": "2023-06-02T17:18:29.697Z",
    "dateUpdated": "2024-08-02T16:10:06.673Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-34389 (GCVE-0-2023-34389)

Vulnerability from cvelistv5 – Published: 2023-11-30 16:54 – Updated: 2024-12-02 17:53
VLAI?
Title
Allocation of resources without limits could lead to denial of service
Summary
An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:06.826Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-34389",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2023-12-05T15:22:53.970614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-02T17:53:15.070Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-469",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-469 HTTP DoS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:54:29.986Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Allocation of resources without limits could lead to denial of service",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-34389",
    "datePublished": "2023-11-30T16:54:29.986Z",
    "dateReserved": "2023-06-02T17:18:29.697Z",
    "dateUpdated": "2024-12-02T17:53:15.070Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-34388 (GCVE-0-2023-34388)

Vulnerability from cvelistv5 – Published: 2023-11-30 16:54 – Updated: 2025-06-03 13:46
VLAI?
Title
Improper authentication could lead to session hijacking
Summary
An Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-287 - Improper Authentication
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:07.027Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-34388",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-03T13:45:41.836921Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T13:46:12.767Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An\u0026nbsp;Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An\u00a0Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        },
        {
          "capecId": "CAPEC-593",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-593 Session Hijacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:54:08.503Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper authentication could lead to session hijacking",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-34388",
    "datePublished": "2023-11-30T16:54:08.503Z",
    "dateReserved": "2023-06-02T17:18:29.696Z",
    "dateUpdated": "2025-06-03T13:46:12.767Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31177 (GCVE-0-2023-31177)

Vulnerability from cvelistv5 – Published: 2023-11-30 16:53 – Updated: 2024-08-02 14:45
VLAI?
Title
Improper neutralizataion of input could lead to execution of arbitrary code
Summary
An Improper Neutralization of Input During Web Page Generation  ('Cross-site Scripting') in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.869Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Neutralization of Input During Web Page Generation\u0026nbsp; (\u0027Cross-site Scripting\u0027) in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim\u0027s system.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An Improper Neutralization of Input During Web Page Generation\u00a0 (\u0027Cross-site Scripting\u0027) in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim\u0027s system.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        },
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:53:34.046Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper neutralizataion of input could lead to execution of arbitrary code",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31177",
    "datePublished": "2023-11-30T16:53:34.046Z",
    "dateReserved": "2023-04-24T23:20:01.610Z",
    "dateUpdated": "2024-08-02T14:45:25.869Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31176 (GCVE-0-2023-31176)

Vulnerability from cvelistv5 – Published: 2023-11-30 16:53 – Updated: 2024-10-16 19:21
VLAI?
Title
Insufficient entropy vulnerability could lead to authentication bypass
Summary
An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.  See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.800Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sel-451_firmware",
            "vendor": "selinc",
            "versions": [
              {
                "lessThan": "R315-V4",
                "status": "affected",
                "version": "R315-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R316-V4",
                "status": "affected",
                "version": "R316-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R317-V4",
                "status": "affected",
                "version": "R317-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R318-V5",
                "status": "affected",
                "version": "R318-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R320-V3",
                "status": "affected",
                "version": "R320-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R321-V3",
                "status": "affected",
                "version": "R321-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R322-V3",
                "status": "affected",
                "version": "R322-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R323-V5",
                "status": "affected",
                "version": "R323-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R324-V4",
                "status": "affected",
                "version": "R324-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R325-V3",
                "status": "affected",
                "version": "R325-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R326-V1",
                "status": "affected",
                "version": "R326-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R327-V1",
                "status": "affected",
                "version": "R327-V0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31176",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T17:28:37.960490Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-16T19:21:05.142Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.\u0026nbsp;\u003cbr\u003e\u003cp\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\u003c/p\u003e\n\n"
            }
          ],
          "value": "An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.\u00a0\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-331",
              "description": "CWE-331 Insufficient Entropy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:53:11.383Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insufficient entropy vulnerability could lead to authentication bypass",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31176",
    "datePublished": "2023-11-30T16:53:11.383Z",
    "dateReserved": "2023-04-24T23:20:01.609Z",
    "dateUpdated": "2024-10-16T19:21:05.142Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-34390 (GCVE-0-2023-34390)

Vulnerability from nvd – Published: 2023-11-30 16:54 – Updated: 2024-08-02 16:10
VLAI?
Title
Improper input validation could lead to denial of service
Summary
An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-20 - Improper Input Validation
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:06.673Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-25",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-25 Forced Deadlock"
            }
          ]
        },
        {
          "capecId": "CAPEC-469",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-469 HTTP DoS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:54:54.190Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": " Improper input validation could lead to denial of service",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-34390",
    "datePublished": "2023-11-30T16:54:54.190Z",
    "dateReserved": "2023-06-02T17:18:29.697Z",
    "dateUpdated": "2024-08-02T16:10:06.673Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-34389 (GCVE-0-2023-34389)

Vulnerability from nvd – Published: 2023-11-30 16:54 – Updated: 2024-12-02 17:53
VLAI?
Title
Allocation of resources without limits could lead to denial of service
Summary
An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:06.826Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-34389",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2023-12-05T15:22:53.970614Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-02T17:53:15.070Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-469",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-469 HTTP DoS"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:54:29.986Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Allocation of resources without limits could lead to denial of service",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-34389",
    "datePublished": "2023-11-30T16:54:29.986Z",
    "dateReserved": "2023-06-02T17:18:29.697Z",
    "dateUpdated": "2024-12-02T17:53:15.070Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-34388 (GCVE-0-2023-34388)

Vulnerability from nvd – Published: 2023-11-30 16:54 – Updated: 2025-06-03 13:46
VLAI?
Title
Improper authentication could lead to session hijacking
Summary
An Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-287 - Improper Authentication
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:10:07.027Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-34388",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-06-03T13:45:41.836921Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-06-03T13:46:12.767Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An\u0026nbsp;Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An\u00a0Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        },
        {
          "capecId": "CAPEC-593",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-593 Session Hijacking"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:54:08.503Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper authentication could lead to session hijacking",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-34388",
    "datePublished": "2023-11-30T16:54:08.503Z",
    "dateReserved": "2023-06-02T17:18:29.696Z",
    "dateUpdated": "2025-06-03T13:46:12.767Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31177 (GCVE-0-2023-31177)

Vulnerability from nvd – Published: 2023-11-30 16:53 – Updated: 2024-08-02 14:45
VLAI?
Title
Improper neutralizataion of input could lead to execution of arbitrary code
Summary
An Improper Neutralization of Input During Web Page Generation  ('Cross-site Scripting') in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.869Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Improper Neutralization of Input During Web Page Generation\u0026nbsp; (\u0027Cross-site Scripting\u0027) in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim\u0027s system.\u003cbr\u003e\u003cbr\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\u003cbr\u003e"
            }
          ],
          "value": "An Improper Neutralization of Input During Web Page Generation\u00a0 (\u0027Cross-site Scripting\u0027) in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim\u0027s system.\n\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-63",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-63 Cross-Site Scripting (XSS)"
            }
          ]
        },
        {
          "capecId": "CAPEC-242",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-242 Code Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:53:34.046Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Improper neutralizataion of input could lead to execution of arbitrary code",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31177",
    "datePublished": "2023-11-30T16:53:34.046Z",
    "dateReserved": "2023-04-24T23:20:01.610Z",
    "dateUpdated": "2024-08-02T14:45:25.869Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-31176 (GCVE-0-2023-31176)

Vulnerability from nvd – Published: 2023-11-30 16:53 – Updated: 2024-10-16 19:21
VLAI?
Title
Insufficient entropy vulnerability could lead to authentication bypass
Summary
An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.  See product Instruction Manual Appendix A dated 20230830 for more details.
CWE
Assigner
SEL
Impacted products
Vendor Product Version
Schweitzer Engineering Laboratories SEL-451 Affected: R315-V0 , < R315-V4 (custom)
Affected: R316-V0 , < R316-V4 (custom)
Affected: R317-V0 , < R317-V4 (custom)
Affected: R318-V0 , < R318-V5 (custom)
Affected: R320-V0 , < R320-V3 (custom)
Affected: R321-V0 , < R321-V3 (custom)
Affected: R322-V0 , < R322-V3 (custom)
Affected: R323-V0 , < R323-V5 (custom)
Affected: R324-V0 , < R324-V4 (custom)
Affected: R325-V0 , < R325-V3 (custom)
Affected: R326-V0 , < R326-V1 (custom)
Affected: R327-V0 , < R327-V1 (custom)
Create a notification for this product.
Credits
Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T14:45:25.800Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.nozominetworks.com/blog/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:selinc:sel-451_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sel-451_firmware",
            "vendor": "selinc",
            "versions": [
              {
                "lessThan": "R315-V4",
                "status": "affected",
                "version": "R315-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R316-V4",
                "status": "affected",
                "version": "R316-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R317-V4",
                "status": "affected",
                "version": "R317-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R318-V5",
                "status": "affected",
                "version": "R318-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R320-V3",
                "status": "affected",
                "version": "R320-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R321-V3",
                "status": "affected",
                "version": "R321-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R322-V3",
                "status": "affected",
                "version": "R322-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R323-V5",
                "status": "affected",
                "version": "R323-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R324-V4",
                "status": "affected",
                "version": "R324-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R325-V3",
                "status": "affected",
                "version": "R325-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R326-V1",
                "status": "affected",
                "version": "R326-V0",
                "versionType": "custom"
              },
              {
                "lessThan": "R327-V1",
                "status": "affected",
                "version": "R327-V0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-31176",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-15T17:28:37.960490Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-16T19:21:05.142Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-451",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R315-V4",
              "status": "affected",
              "version": "R315-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R316-V4",
              "status": "affected",
              "version": "R316-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R317-V4",
              "status": "affected",
              "version": "R317-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R318-V5",
              "status": "affected",
              "version": "R318-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R320-V3",
              "status": "affected",
              "version": "R320-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R321-V3",
              "status": "affected",
              "version": "R321-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R322-V3",
              "status": "affected",
              "version": "R322-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R323-V5",
              "status": "affected",
              "version": "R323-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R324-V4",
              "status": "affected",
              "version": "R324-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R325-V3",
              "status": "affected",
              "version": "R325-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R326-V1",
              "status": "affected",
              "version": "R326-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R327-V1",
              "status": "affected",
              "version": "R327-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
        }
      ],
      "datePublic": "2023-11-30T09:56:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.\u0026nbsp;\u003cbr\u003e\u003cp\u003e\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\u003c/p\u003e\n\n"
            }
          ],
          "value": "An Insufficient Entropy vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow an unauthenticated remote attacker to brute-force session tokens and bypass authentication.\u00a0\n\n\nSee product Instruction Manual Appendix A dated 20230830 for more details.\n\n\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-115",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-115 Authentication Bypass"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-331",
              "description": "CWE-331 Insufficient Entropy",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-30T16:53:11.383Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        },
        {
          "url": "https://www.nozominetworks.com/blog/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insufficient entropy vulnerability could lead to authentication bypass",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2023-31176",
    "datePublished": "2023-11-30T16:53:11.383Z",
    "dateReserved": "2023-04-24T23:20:01.609Z",
    "dateUpdated": "2024-10-16T19:21:05.142Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}