Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    40 vulnerabilities by selinc

    VAR-201807-0337

    Vulnerability from variot - Updated: 2023-12-18 12:50

    SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the Compass installation folder, resulting in escalation of privilege and/or malicious code execution. SEL Compass Contains a permission vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SEL Compass is an application for managing and updating SEL products from Schweitzer Engineering Laboratories (SEL), USA. A privilege elevation vulnerability exists in SEL Compass 3.0.5.1 and earlier. The vulnerability stems from a program failing to properly set access rights

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201807-0337",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "sel compass",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "selinc",
            "version": "3.0.5.1"
          },
          {
            "model": "compass",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "3.0.5.1"
          },
          {
            "model": "compass",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "schweitzer engineering laboratories",
            "version": "\u003c=3.0.5.1"
          },
          {
            "model": "sel compass",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "selinc",
            "version": "3.0.5.1"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "sel compass",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:selinc:sel_compass:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "3.0.5.1",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          }
        ]
      },
      "cve": "CVE-2018-10604",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "Single",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 6.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2018-10604",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "CNVD-2018-18610",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 3.9,
                "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.9 [IVD]"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-10604",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-10604",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2018-18610",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201807-1816",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1",
                "trust": 0.2,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the Compass installation folder, resulting in escalation of privilege and/or malicious code execution. SEL Compass Contains a permission vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SEL Compass is an application for managing and updating SEL products from Schweitzer Engineering Laboratories (SEL), USA. A privilege elevation vulnerability exists in SEL Compass 3.0.5.1 and earlier. The vulnerability stems from a program failing to properly set access rights",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-10604",
            "trust": 3.2
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-18-191-02",
            "trust": 3.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "E2F998B1-39AB-11E9-A7BE-000C29342CB1",
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "id": "VAR-201807-0337",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          }
        ],
        "trust": 1.55
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:50:38.428000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEL Compass",
            "trust": 0.8,
            "url": "https://selinc.com/products/compass/"
          },
          {
            "title": "Patch for SEL Compass Privilege Escalation Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/139987"
          },
          {
            "title": "SEL Compass Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=82597"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-276",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-275",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-191-02"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10604"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10604"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-09-12T00:00:00",
            "db": "IVD",
            "id": "e2f998b1-39ab-11e9-a7be-000c29342cb1"
          },
          {
            "date": "2018-09-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "date": "2018-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "date": "2018-07-24T13:29:00.353000",
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "date": "2018-07-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-09-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-18610"
          },
          {
            "date": "2018-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          },
          {
            "date": "2020-08-31T16:09:22.273000",
            "db": "NVD",
            "id": "CVE-2018-10604"
          },
          {
            "date": "2020-10-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SEL Compass Permissions vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008486"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1816"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201807-0335

    Vulnerability from variot - Updated: 2023-12-18 12:50

    SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks. SEL AcSELerator Architect In XML An external entity vulnerability exists.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. SEL AcSELerator Architect is a system used by Schweitzer Engineering Laboratories (SEL) to communicate with, configure and manage substations. An injection injection vulnerability exists in SEL AcSELerator Architect 2.2.24.0 and earlier. In some cases on a particular platform) and cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201807-0335",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "acselerator architect",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "selinc",
            "version": "2.2.24.0"
          },
          {
            "model": "acselerator architect",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "2.2.24.0"
          },
          {
            "model": "acselerator architect",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "schweitzer engineering laboratories",
            "version": "\u003c=2.2.24.0"
          },
          {
            "model": "acselerator architect",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "selinc",
            "version": "2.2.24.0"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "acselerator architect",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:selinc:acselerator_architect:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.2.24.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          }
        ]
      },
      "cve": "CVE-2018-10600",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 7.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2018-10600",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 8.5,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2018-18602",
                "impactScore": 7.8,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 8.5,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1",
                "impactScore": 7.8,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:P",
                "version": "2.9 [IVD]"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-10600",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-10600",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2018-18602",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201807-1818",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "IVD",
                "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1",
                "trust": 0.2,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks. SEL AcSELerator Architect In XML An external entity vulnerability exists.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. SEL AcSELerator Architect is a system used by Schweitzer Engineering Laboratories (SEL) to communicate with, configure and manage substations. An injection injection vulnerability exists in SEL AcSELerator Architect 2.2.24.0 and earlier. In some cases on a particular platform) and cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-10600",
            "trust": 3.2
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-18-191-02",
            "trust": 3.0
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "E2F9BFC0-39AB-11E9-B0D8-000C29342CB1",
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "id": "VAR-201807-0335",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          }
        ],
        "trust": 1.55
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:50:38.399000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEL-5032 ACSELERATOR Architect Software",
            "trust": 0.8,
            "url": "https://selinc.com/products/5032/#tab-downloads"
          },
          {
            "title": "Patch for SEL AcSELerator Architect XML Injection Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/139997"
          },
          {
            "title": "SEL AcSELerator Architect Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=82599"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-611",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-191-02"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10600"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10600"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-09-12T00:00:00",
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "date": "2018-09-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "date": "2018-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "date": "2018-07-24T13:29:00.307000",
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "date": "2018-07-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-09-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-18602"
          },
          {
            "date": "2018-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          },
          {
            "date": "2019-10-09T23:32:53.290000",
            "db": "NVD",
            "id": "CVE-2018-10600"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SEL AcSELerator Architect In  XML External entity vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008485"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Code problem",
        "sources": [
          {
            "db": "IVD",
            "id": "e2f9bfc0-39ab-11e9-b0d8-000c29342cb1"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1818"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201807-0339

    Vulnerability from variot - Updated: 2023-12-18 12:50

    SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required. SEL AcSELerator Architect Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. SEL AcSELerator Architect is a system used by Schweitzer Engineering Laboratories (SEL) to communicate with, configure and manage substations

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201807-0339",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "acselerator architect",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "selinc",
            "version": "2.2.24.0"
          },
          {
            "model": "acselerator architect",
            "scope": "lte",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "2.2.24.0"
          },
          {
            "model": "acselerator architect",
            "scope": "lte",
            "trust": 0.6,
            "vendor": "schweitzer engineering laboratories",
            "version": "\u003c=2.2.24.0"
          },
          {
            "model": "acselerator architect",
            "scope": "eq",
            "trust": 0.6,
            "vendor": "selinc",
            "version": "2.2.24.0"
          },
          {
            "model": null,
            "scope": "eq",
            "trust": 0.2,
            "vendor": "acselerator architect",
            "version": "*"
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:a:selinc:acselerator_architect:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndIncluding": "2.2.24.0",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "LiquidWorm",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ],
        "trust": 0.6
      },
      "cve": "CVE-2018-10608",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 7.8,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2018-10608",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2018-18609",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.9 [IVD]"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2018-10608",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-10608",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2018-18609",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201807-1815",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1",
                "trust": 0.2,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required. SEL AcSELerator Architect Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. SEL AcSELerator Architect is a system used by Schweitzer Engineering Laboratories (SEL) to communicate with, configure and manage substations",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-10608",
            "trust": 3.2
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-18-191-02",
            "trust": 3.0
          },
          {
            "db": "PACKETSTORM",
            "id": "152951",
            "trust": 1.6
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487",
            "trust": 0.8
          },
          {
            "db": "EXPLOIT-DB",
            "id": "46859",
            "trust": 0.6
          },
          {
            "db": "IVD",
            "id": "E2F971A3-39AB-11E9-81CE-000C29342CB1",
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "id": "VAR-201807-0339",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          }
        ],
        "trust": 1.55
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:50:38.369000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "ACSELERATOR Architect Software",
            "trust": 0.8,
            "url": "https://selinc.com/products/5032/"
          },
          {
            "title": "SEL AcSELerator Architect Denial of Service Vulnerability Patch",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/139983"
          },
          {
            "title": "SEL AcSELerator Architect Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=82596"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-400",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-191-02"
          },
          {
            "trust": 2.2,
            "url": "http://packetstormsecurity.com/files/152951/sel-acselerator-architect-2.2.24-denial-of-service.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-10608"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-10608"
          },
          {
            "trust": 0.6,
            "url": "https://www.exploit-db.com/exploits/46859"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-09-12T00:00:00",
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "date": "2018-09-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "date": "2018-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "date": "2018-07-24T13:29:00.400000",
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "date": "2018-07-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-09-12T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          },
          {
            "date": "2018-10-19T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-008487"
          },
          {
            "date": "2019-05-17T01:29:00.273000",
            "db": "NVD",
            "id": "CVE-2018-10608"
          },
          {
            "date": "2019-05-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "SEL AcSELerator Architect Denial of service vulnerability",
        "sources": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-18609"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Resource management error",
        "sources": [
          {
            "db": "IVD",
            "id": "e2f971a3-39ab-11e9-81ce-000c29342cb1"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201807-1815"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201708-1389

    Vulnerability from variot - Updated: 2023-12-18 12:37

    An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may allow for unauthorized communications to downstream devices. An attacker could exploit the vulnerability to communicate with downstream devices. Attackers can exploit this issue to gain unauthorized access to the affected device. This may aid in further attacks. The following versions are vulnerable: SEL-3620 R202, R203, R203-V1, R203-V2, R204, and R204-V1 SEL-3622 R202, R203, R203-V1, R203-V2, R204, and R204-V1

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201708-1389",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "sel-3620",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r202"
          },
          {
            "model": "sel-3620",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r203-v"
          },
          {
            "model": "sel-3622",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r204-v1"
          },
          {
            "model": "sel-3622",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r204"
          },
          {
            "model": "sel-3620",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r203-v1"
          },
          {
            "model": "sel-3620",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r204"
          },
          {
            "model": "sel-3620",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r204-v1"
          },
          {
            "model": "sel-3622",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r203"
          },
          {
            "model": "sel-3620",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r203"
          },
          {
            "model": "sel-3622",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r202"
          },
          {
            "model": "sel-3622",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "selinc",
            "version": "r203-v"
          },
          {
            "model": "sel-3622",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "selinc",
            "version": "r203-v1"
          },
          {
            "model": "engineering laboratories sel-3620 r202",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3620 r203",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3620 r203-v1",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3620 r203-v2",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3620 r204",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3620 r204-v1",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3622 r202",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3622 r203",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3622 r203-v1",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3622 r203-v2",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3622 r204",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3622 r204-v1",
            "scope": null,
            "trust": 0.9,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "sel-3620",
            "scope": null,
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": null
          },
          {
            "model": "sel-3622",
            "scope": null,
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": null
          },
          {
            "model": "r202",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3620",
            "version": null
          },
          {
            "model": "r203",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3620",
            "version": null
          },
          {
            "model": "r203-v",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3620",
            "version": null
          },
          {
            "model": "r203-v1",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3620",
            "version": null
          },
          {
            "model": "r204",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3620",
            "version": null
          },
          {
            "model": "r204-v1",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3620",
            "version": null
          },
          {
            "model": "r202",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3622",
            "version": null
          },
          {
            "model": "r203",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3622",
            "version": null
          },
          {
            "model": "r203-v",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3622",
            "version": null
          },
          {
            "model": "r203-v1",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3622",
            "version": null
          },
          {
            "model": "r204",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3622",
            "version": null
          },
          {
            "model": "r204-v1",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3622",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "BID",
            "id": "99536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3620_firmware:r203:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3620_firmware:r203-v:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3620_firmware:r204-v1:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3620_firmware:r202:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3620_firmware:r203-v1:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3620_firmware:r204:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:selinc:sel-3620:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3622_firmware:r203-v1:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3622_firmware:r204:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3622_firmware:r202:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3622_firmware:r203:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3622_firmware:r203-v:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      },
                      {
                        "cpe23Uri": "cpe:2.3:o:selinc:sel-3622_firmware:r204-v1:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:selinc:sel-3622:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Jason Holcomb",
        "sources": [
          {
            "db": "BID",
            "id": "99536"
          }
        ],
        "trust": 0.3
      },
      "cve": "CVE-2017-7928",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 7.5,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2017-7928",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2017-22833",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.9 [IVD]"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-116131",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 10.0,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 10.0,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2017-7928",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2017-7928",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2017-22833",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201704-932",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "IVD",
                "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5",
                "trust": 0.2,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-116131",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2017-7928",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7928"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may allow for unauthorized communications to downstream devices. An attacker could exploit the vulnerability to communicate with downstream devices. \nAttackers can exploit this issue to gain unauthorized access to the affected device. This may aid in further attacks. \nThe following versions are vulnerable:\nSEL-3620 R202, R203, R203-V1, R203-V2, R204, and R204-V1\nSEL-3622 R202, R203, R203-V1, R203-V2, R204, and R204-V1",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "BID",
            "id": "99536"
          },
          {
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7928"
          }
        ],
        "trust": 2.79
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2017-7928",
            "trust": 3.7
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-17-192-06",
            "trust": 3.5
          },
          {
            "db": "BID",
            "id": "99536",
            "trust": 2.7
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932",
            "trust": 0.9
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "E5C3576C-4D56-4689-AF8A-7DC7F07200B5",
            "trust": 0.2
          },
          {
            "db": "VULHUB",
            "id": "VHN-116131",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7928",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7928"
          },
          {
            "db": "BID",
            "id": "99536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "id": "VAR-201708-1389",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116131"
          }
        ],
        "trust": 1.65
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:37:14.481000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "SEL-3620",
            "trust": 0.8,
            "url": "https://selinc.com/products/3620/"
          },
          {
            "title": "SEL-3622",
            "trust": 0.8,
            "url": "https://selinc.com/products/3622/"
          },
          {
            "title": "Schweitzer Engineering Laboratories SEL-3620 and SEL-3622 Security Gateway are not authorized to access vulnerable patches",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/100855"
          },
          {
            "title": "Schweitzer Engineering Laboratories SEL-3620  and SEL-3622 Security Gateway Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=99747"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-264",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.6,
            "url": "https://ics-cert.us-cert.gov/advisories/icsa-17-192-06"
          },
          {
            "trust": 2.4,
            "url": "http://www.securityfocus.com/bid/99536"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-7928"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2017-7928"
          },
          {
            "trust": 0.3,
            "url": "https://selinc.com/"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7928"
          },
          {
            "db": "BID",
            "id": "99536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "db": "VULMON",
            "id": "CVE-2017-7928"
          },
          {
            "db": "BID",
            "id": "99536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-25T00:00:00",
            "db": "IVD",
            "id": "e5c3576c-4d56-4689-af8a-7dc7f07200b5"
          },
          {
            "date": "2017-08-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "date": "2017-08-07T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "date": "2017-08-07T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-7928"
          },
          {
            "date": "2017-07-11T00:00:00",
            "db": "BID",
            "id": "99536"
          },
          {
            "date": "2017-09-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "date": "2017-08-07T08:29:00.290000",
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "date": "2017-04-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2017-08-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2017-22833"
          },
          {
            "date": "2019-10-09T00:00:00",
            "db": "VULHUB",
            "id": "VHN-116131"
          },
          {
            "date": "2019-10-09T00:00:00",
            "db": "VULMON",
            "id": "CVE-2017-7928"
          },
          {
            "date": "2017-07-11T00:00:00",
            "db": "BID",
            "id": "99536"
          },
          {
            "date": "2017-09-12T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          },
          {
            "date": "2019-10-09T23:29:59.627000",
            "db": "NVD",
            "id": "CVE-2017-7928"
          },
          {
            "date": "2019-10-17T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schweitzer Engineering Laboratories SEL-3620 and  SEL-3622 Security Gateway Vulnerabilities related to authorization, permissions, and access control",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2017-007168"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "permissions and access control issues",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201704-932"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201308-0166

    Vulnerability from variot - Updated: 2023-12-18 12:21

    Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. Schweitzer Engineering Laboratories is a leading manufacturer in Washington State, USA, and is a leader in power system relay protection, control, monitoring, metering and SCADA. Under certain conditions, the DNP3 driver will automatically restart and resume communication, but in severe cases, the device ALARM contact will trigger an assertion and need to reload the device driver settings. The affected products are as follows: SEL-3530-R100 -V0-Z001001-D20090915 - SEL-3530- SEL-3530-R123-V0-Z002001SEL-3530-4-R107-V0-Z001001-D20100818 - SEL-3530-4-R123 -V0-Z002001-D20130117SEL-3505-R119-V0-Z001001-D20120720 - SEL-3505-R123-V0-Z002001-D20130117SEL-2241-R113-V0-Z001001-D20110721 - SEL-2241-R123-V0-Z002001-D20130117. Multiple Schweitzer Engineering Laboratories devices are prone to a remote denial-of-service vulnerability. An attacker can exploit this issue to crash the affected device, denying service to legitimate users. Note: This issue affects the IP connected devices

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201308-0166",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "sel-3530-4",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r107-v0-z001001-d20100818"
          },
          {
            "model": "sel-2241",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r113-v0-z001001-d20110721"
          },
          {
            "model": "sel-3530",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r100_-v0-z001001-d20090915"
          },
          {
            "model": "sel-3530",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001"
          },
          {
            "model": "sel-3505",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3530-4",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3505",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r119-v0-z001001-d20120720"
          },
          {
            "model": "sel-2241",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-2241",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r113-v0-z001001-d20110721 to  sel-2241-r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3505",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r119-v0-z001001-d20120720 to  sel-3505-r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3530",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r100 -v0-z001001-d20090915 to  sel-3530- sel-3530-r123-v0-z002001"
          },
          {
            "model": "sel-3530-4",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r107-v0-z001001-d20100818 to  sel-3530-4-r123-v0-z002001-d20130117"
          },
          {
            "model": "engineering laboratories sel-3530 rtac",
            "scope": null,
            "trust": 0.6,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3505 rtac",
            "scope": null,
            "trust": 0.6,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-2241 rtac",
            "scope": null,
            "trust": 0.6,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "r113-v0-z001001-d20110721",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 2241",
            "version": null
          },
          {
            "model": "r123-v0-z002001-d20130117",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 2241",
            "version": null
          },
          {
            "model": "r119-v0-z001001-d20120720",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3505",
            "version": null
          },
          {
            "model": "r123-v0-z002001-d20130117",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3505",
            "version": null
          },
          {
            "model": "r100 -v0-z001001-d20090915",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530",
            "version": null
          },
          {
            "model": "r123-v0-z002001",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530",
            "version": null
          },
          {
            "model": "r107-v0-z001001-d20100818",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530 4",
            "version": null
          },
          {
            "model": "r123-v0-z002001-d20130117",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530 4",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-2241:r113-v0-z001001-d20110721:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530:r123-v0-z002001:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3505:r119-v0-z001001-d20120720:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3505:r123-v0-z002001-d20130117:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530-4:r107-v0-z001001-d20100818:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530-4:r123-v0-z002001-d20130117:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-2241:r123-v0-z002001-d20130117:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530:r100_-v0-z001001-d20090915:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Adam Crain of Automatak and Chris Sistrunk",
        "sources": [
          {
            "db": "BID",
            "id": "61665"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ],
        "trust": 0.9
      },
      "cve": "CVE-2013-2792",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 7.1,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2013-2792",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "id": "CNVD-2013-12158",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.1,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 8.6,
                "id": "c9668f1a-2352-11e6-abef-000c29c66e3d",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.2,
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.9 [IVD]"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2013-2792",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2013-12158",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201308-130",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "IVD",
                "id": "c9668f1a-2352-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. Schweitzer Engineering Laboratories is a leading manufacturer in Washington State, USA, and is a leader in power system relay protection, control, monitoring, metering and SCADA. Under certain conditions, the DNP3 driver will automatically restart and resume communication, but in severe cases, the device ALARM contact will trigger an assertion and need to reload the device driver settings. The affected products are as follows: SEL-3530-R100 -V0-Z001001-D20090915 - SEL-3530- SEL-3530-R123-V0-Z002001SEL-3530-4-R107-V0-Z001001-D20100818 - SEL-3530-4-R123 -V0-Z002001-D20130117SEL-3505-R119-V0-Z001001-D20120720 - SEL-3505-R123-V0-Z002001-D20130117SEL-2241-R113-V0-Z001001-D20110721 - SEL-2241-R123-V0-Z002001-D20130117. Multiple Schweitzer Engineering Laboratories devices are prone to a remote denial-of-service vulnerability. \nAn attacker can exploit this issue to crash the affected device, denying service to legitimate users. \nNote: This issue affects the IP connected devices",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "db": "BID",
            "id": "61665"
          },
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          }
        ],
        "trust": 2.61
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2013-2792",
            "trust": 3.5
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-13-219-01",
            "trust": 3.0
          },
          {
            "db": "BID",
            "id": "61665",
            "trust": 1.5
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "C9668F1A-2352-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "db": "BID",
            "id": "61665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ]
      },
      "id": "VAR-201308-0166",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          }
        ],
        "trust": 1.8
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:21:39.849000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.selinc.com/default.aspx"
          },
          {
            "title": "SEL-3505 Automation Controller",
            "trust": 0.8,
            "url": "https://www.selinc.com/sel-3505"
          },
          {
            "title": "Real-Time Automation Controller (RTAC)",
            "trust": 0.8,
            "url": "https://www.selinc.com/sel-3530"
          },
          {
            "title": "SEL-2240 Axion Distributed Control and Integration Platform",
            "trust": 0.8,
            "url": "https://www.selinc.com/sel-2240/"
          },
          {
            "title": "Schweitzer Engineering Laboratories Patch for Multiple Device Remote Denial of Service Vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/38161"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-20",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.0,
            "url": "http://ics-cert.us-cert.gov/advisories/icsa-13-219-01"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-2792"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-2792"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/bid/61665"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "db": "BID",
            "id": "61665"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2013-08-13T00:00:00",
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2013-08-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "date": "2013-08-07T00:00:00",
            "db": "BID",
            "id": "61665"
          },
          {
            "date": "2013-08-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "date": "2013-08-09T23:55:02.513000",
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "date": "2013-08-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2013-08-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2013-12158"
          },
          {
            "date": "2013-10-21T00:18:00",
            "db": "BID",
            "id": "61665"
          },
          {
            "date": "2013-08-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          },
          {
            "date": "2013-08-12T20:00:00.960000",
            "db": "NVD",
            "id": "CVE-2013-2792"
          },
          {
            "date": "2013-08-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  Schweitzer Engineering Laboratories Service disruption in products  (DoS) Vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003714"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Input validation",
        "sources": [
          {
            "db": "IVD",
            "id": "c9668f1a-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-130"
          }
        ],
        "trust": 0.8
      }
    }

    VAR-201308-0168

    Vulnerability from variot - Updated: 2023-12-18 12:21

    Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. Schweitzer Engineering Laboratories is a leading manufacturer in Washington State, USA, and is a leader in power system relay protection, control, monitoring, metering and SCADA. Under certain conditions, the DNP3 driver will automatically restart and resume communication, but in severe cases, the device ALARM contact will trigger an assertion and need to reload the device driver settings. The affected products are as follows: SEL-3530-R100 -V0-Z001001-D20090915 - SEL-3530- SEL-3530-R123-V0-Z002001SEL-3530-4-R107-V0-Z001001-D20100818 - SEL-3530-4-R123 -V0-Z002001-D20130117SEL-3505-R119-V0-Z001001-D20120720 - SEL-3505-R123-V0-Z002001-D20130117SEL-2241-R113-V0-Z001001-D20110721 - SEL-2241-R123-V0-Z002001-D20130117. Schweitzer Engineering Laboratories multiple devices are prone to a local denial-of-service vulnerability. An attacker can exploit this issue to crash the affected device, denying service to legitimate users. NOTE: To exploit this issue, local access to the serial-based outstation is required

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201308-0168",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "sel-3530-4",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r107-v0-z001001-d20100818"
          },
          {
            "model": "sel-2241",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r113-v0-z001001-d20110721"
          },
          {
            "model": "sel-3530",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r100_-v0-z001001-d20090915"
          },
          {
            "model": "sel-3530",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001"
          },
          {
            "model": "sel-3505",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3530-4",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3505",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r119-v0-z001001-d20120720"
          },
          {
            "model": "sel-2241",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "selinc",
            "version": "r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-2241",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r113-v0-z001001-d20110721 to  sel-2241-r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3505",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r119-v0-z001001-d20120720 to  sel-3505-r123-v0-z002001-d20130117"
          },
          {
            "model": "sel-3530",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r100 -v0-z001001-d20090915 to  sel-3530- sel-3530-r123-v0-z002001"
          },
          {
            "model": "sel-3530-4",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "schweitzer engineering laboratories",
            "version": "r107-v0-z001001-d20100818 to  sel-3530-4-r123-v0-z002001-d20130117"
          },
          {
            "model": "engineering laboratories sel-3530 rtac",
            "scope": null,
            "trust": 0.6,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-3505 rtac",
            "scope": null,
            "trust": 0.6,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "engineering laboratories sel-2241 rtac",
            "scope": null,
            "trust": 0.6,
            "vendor": "schweitzer",
            "version": null
          },
          {
            "model": "sel-3530-se-3530-r123-v0-z002001",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "sel-3530-r100 -v0-z001001-d20090915",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "sel-3530-4-r123-v0-z002001-d20130117",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "sel-3530-4-r107-v0-z001001-d20100818",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "sel-3505-r123-v0-z002001-d20130117",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "sel-3505-r119-v0-z001001-d20120720",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "sel-2241-r123-v0-z002001-d20130117",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "sel-2241-r113-v0-z001001-d20110721",
            "scope": "eq",
            "trust": 0.3,
            "vendor": "schweitzer engineering laboratories",
            "version": "0"
          },
          {
            "model": "r113-v0-z001001-d20110721",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 2241",
            "version": null
          },
          {
            "model": "r123-v0-z002001-d20130117",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 2241",
            "version": null
          },
          {
            "model": "r119-v0-z001001-d20120720",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3505",
            "version": null
          },
          {
            "model": "r123-v0-z002001-d20130117",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3505",
            "version": null
          },
          {
            "model": "r100 -v0-z001001-d20090915",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530",
            "version": null
          },
          {
            "model": "r123-v0-z002001",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530",
            "version": null
          },
          {
            "model": "r107-v0-z001001-d20100818",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530 4",
            "version": null
          },
          {
            "model": "r123-v0-z002001-d20130117",
            "scope": null,
            "trust": 0.2,
            "vendor": "sel 3530 4",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "BID",
            "id": "61667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-2241:r113-v0-z001001-d20110721:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530:r123-v0-z002001:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3505:r119-v0-z001001-d20120720:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3505:r123-v0-z002001-d20130117:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530-4:r107-v0-z001001-d20100818:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530-4:r123-v0-z002001-d20130117:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-3530:r100_-v0-z001001-d20090915:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:h:selinc:sel-2241:r123-v0-z002001-d20130117:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          }
        ]
      },
      "credits": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/credits#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Adam Crain of Automatak and Chris Sistrunk",
        "sources": [
          {
            "db": "BID",
            "id": "61667"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ],
        "trust": 0.9
      },
      "cve": "CVE-2013-2798",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 4.7,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.4,
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:L/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Medium",
                "accessVector": "Local",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 4.7,
                "confidentialityImpact": "None",
                "exploitabilityScore": null,
                "id": "CVE-2013-2798",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:L/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 4.7,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.4,
                "id": "CNVD-2013-12159",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:L/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "author": "IVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 4.7,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.4,
                "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.2,
                "vectorString": "AV:L/AC:M/Au:N/C:N/I:N/A:C",
                "version": "2.9 [IVD]"
              }
            ],
            "cvssV3": [],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2013-2798",
                "trust": 1.8,
                "value": "MEDIUM"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2013-12159",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201308-131",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "IVD",
                "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d",
                "trust": 0.2,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. Schweitzer Engineering Laboratories is a leading manufacturer in Washington State, USA, and is a leader in power system relay protection, control, monitoring, metering and SCADA. Under certain conditions, the DNP3 driver will automatically restart and resume communication, but in severe cases, the device ALARM contact will trigger an assertion and need to reload the device driver settings. The affected products are as follows: SEL-3530-R100 -V0-Z001001-D20090915 - SEL-3530- SEL-3530-R123-V0-Z002001SEL-3530-4-R107-V0-Z001001-D20100818 - SEL-3530-4-R123 -V0-Z002001-D20130117SEL-3505-R119-V0-Z001001-D20120720 - SEL-3505-R123-V0-Z002001-D20130117SEL-2241-R113-V0-Z001001-D20110721 - SEL-2241-R123-V0-Z002001-D20130117. Schweitzer Engineering Laboratories multiple devices are prone to a local denial-of-service vulnerability. \nAn attacker can exploit this issue to crash the affected device, denying service to legitimate users. \nNOTE: To exploit this issue, local access to the serial-based outstation is required",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "BID",
            "id": "61667"
          },
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          }
        ],
        "trust": 2.61
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2013-2798",
            "trust": 3.5
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-13-219-01",
            "trust": 3.3
          },
          {
            "db": "BID",
            "id": "61667",
            "trust": 1.5
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716",
            "trust": 0.8
          },
          {
            "db": "IVD",
            "id": "C94D5DC4-2352-11E6-ABEF-000C29C66E3D",
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "BID",
            "id": "61667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ]
      },
      "id": "VAR-201308-0168",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          }
        ],
        "trust": 1.8
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          },
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.2
          }
        ],
        "sources": [
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          }
        ]
      },
      "last_update_date": "2023-12-18T12:21:39.815000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "https://www.selinc.com/default.aspx"
          },
          {
            "title": "SEL-2241 RTAC",
            "trust": 0.8,
            "url": "https://www.selinc.com/workarea/downloadasset.aspx?id=97914"
          },
          {
            "title": "SEL-3505 Automation Controller",
            "trust": 0.8,
            "url": "https://www.selinc.com/sel-3505/"
          },
          {
            "title": "Real-Time Automation Controller (RTAC)",
            "trust": 0.8,
            "url": "https://www.selinc.com/sel-3530/"
          },
          {
            "title": "Patch for multiple device local denial of service vulnerabilities in Schweitzer Engineering Laboratories",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchinfo/show/38162"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-20",
            "trust": 1.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 3.3,
            "url": "http://ics-cert.us-cert.gov/advisories/icsa-13-219-01"
          },
          {
            "trust": 0.8,
            "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2013-2798"
          },
          {
            "trust": 0.8,
            "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2013-2798"
          },
          {
            "trust": 0.6,
            "url": "http://www.securityfocus.com/bid/61667"
          },
          {
            "trust": 0.3,
            "url": "https://www.selinc.com/sel-3530/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "BID",
            "id": "61667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "BID",
            "id": "61667"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2013-08-13T00:00:00",
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "date": "2013-08-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "date": "2013-08-07T00:00:00",
            "db": "BID",
            "id": "61667"
          },
          {
            "date": "2013-08-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "date": "2013-08-09T23:55:02.560000",
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "date": "2013-08-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2013-08-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "date": "2013-08-07T00:00:00",
            "db": "BID",
            "id": "61667"
          },
          {
            "date": "2013-08-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2013-003716"
          },
          {
            "date": "2013-08-12T20:23:44.803000",
            "db": "NVD",
            "id": "CVE-2013-2798"
          },
          {
            "date": "2013-08-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "local",
        "sources": [
          {
            "db": "BID",
            "id": "61667"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ],
        "trust": 0.9
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Schweitzer Engineering Laboratories Multiple Device Local Denial of Service Vulnerabilities",
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2013-12159"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ],
        "trust": 1.2
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Input validation",
        "sources": [
          {
            "db": "IVD",
            "id": "c94d5dc4-2352-11e6-abef-000c29c66e3d"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201308-131"
          }
        ],
        "trust": 0.8
      }
    }

    CVE-2023-34392 (GCVE-0-2023-34392)

    Vulnerability from nvd – Published: 2023-08-31 15:31 – Updated: 2024-10-01 16:59
    VLAI
    Title
    Missing Authentication for Critical Function
    Summary
    A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:10:06.984Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-34392",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T16:59:13.785566Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T16:59:22.498Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-180",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:57.140Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-34392",
        "datePublished": "2023-08-31T15:31:57.140Z",
        "dateReserved": "2023-06-02T17:18:29.697Z",
        "dateUpdated": "2024-10-01T16:59:22.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-34391 (GCVE-0-2023-34391)

    Vulnerability from nvd – Published: 2023-08-31 15:31 – Updated: 2024-10-01 17:02
    VLAI
    Title
    Insecure Inherited Permissions
    Summary
    Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-277 - Insecure Inherited Permissions
    Assigner
    SEL
    Impacted products
    Vendor Product Version
    Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software Affected: 0 , < 1.35.151.21000 (custom)
    Create a notification for this product.
    schweitzer_engineering_laboratories sel-5033_acselerator_rtac_software Affected: 0 , < 1.35.151.21000 (custom)
        cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-08-31 16:00
    Credits
    Reid Wightman of Dragos
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:10:07.006Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dragos.com"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sel-5033_acselerator_rtac_software",
                "vendor": "schweitzer_engineering_laboratories",
                "versions": [
                  {
                    "lessThan": "1.35.151.21000",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-34391",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T16:59:56.064084Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T17:02:03.948Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5033 AcSELerator RTAC Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "1.35.151.21000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths.\u003cbr\u003e\u003cbr\u003eSee Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details.\u003cbr\u003e \u003cbr\u003eThis issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000.\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths.\n\nSee Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details.\n \nThis issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-38",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-38 Leveraging/Manipulating Configuration File Search Paths"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-277",
                  "description": "CWE-277: Insecure Inherited Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:45.454Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://dragos.com"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Insecure Inherited Permissions",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-34391",
        "datePublished": "2023-08-31T15:31:45.454Z",
        "dateReserved": "2023-06-02T17:18:29.697Z",
        "dateUpdated": "2024-10-01T17:02:03.948Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31175 (GCVE-0-2023-31175)

    Vulnerability from nvd – Published: 2023-08-31 15:31 – Updated: 2024-10-01 17:03
    VLAI
    Title
    Execution with Unnecessary Privileges
    Summary
    An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-250 - Execution with Unnecesary Privileges
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Andrea Palanca of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.726Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31175",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T17:03:22.630108Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T17:03:31.524Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Andrea Palanca of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250 Execution with Unnecesary Privileges",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:33.536Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Execution with Unnecessary Privileges",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31175",
        "datePublished": "2023-08-31T15:31:33.536Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-10-01T17:03:31.524Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31174 (GCVE-0-2023-31174)

    Vulnerability from nvd – Published: 2023-08-31 15:31 – Updated: 2024-09-30 15:47
    VLAI
    Title
    Cross-Site Request Forgery (CSRF)
    Summary
    A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-352 - Cross-Site Request Forgery (CSRF)
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Andrea Palanca of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.824Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31174",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-30T15:44:33.294603Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-30T15:47:25.305Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Andrea Palanca of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "\nA Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-62",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-62 Cross Site Request Forgery"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "CWE-352 Cross-Site Request Forgery (CSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:26.657Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Cross-Site Request Forgery (CSRF)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31174",
        "datePublished": "2023-08-31T15:31:26.657Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-09-30T15:47:25.305Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31173 (GCVE-0-2023-31173)

    Vulnerability from nvd – Published: 2023-08-31 15:30 – Updated: 2024-10-01 17:21
    VLAI
    Title
    Use of Hard-coded Credentials
    Summary
    Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    SEL
    Impacted products
    Vendor Product Version
    Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator Affected: 0 , < 4.5.0.20 (custom)
    Create a notification for this product.
    schweitzer_engineering_laboratories sel-5033_acselerator_rtac_software Affected: 0 , < 4.5.0.20 (custom)
        cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.747Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sel-5033_acselerator_rtac_software",
                "vendor": "schweitzer_engineering_laboratories",
                "versions": [
                  {
                    "lessThan": "4.5.0.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31173",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T17:20:11.993761Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T17:21:39.818Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass.\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass.\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:58.262Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Use of Hard-coded Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31173",
        "datePublished": "2023-08-31T15:30:58.262Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-10-01T17:21:39.818Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31172 (GCVE-0-2023-31172)

    Vulnerability from nvd – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:42
    VLAI
    Title
    Incomplete Filtering of Special Elements
    Summary
    An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-791 - Incomplete Filtering of Special Elements
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.755Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31172",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:05:16.595821Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:42:58.512Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-791",
                  "description": "CWE-791: Incomplete Filtering of Special Elements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:49.213Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Incomplete Filtering of Special Elements",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31172",
        "datePublished": "2023-08-31T15:30:49.213Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-09-27T18:42:58.512Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31171 (GCVE-0-2023-31171)

    Vulnerability from nvd – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:48
    VLAI
    Title
    Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Summary
    An Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.875Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31171",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:06:44.809247Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:48:28.691Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:41.030Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31171",
        "datePublished": "2023-08-31T15:30:41.030Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-09-27T18:48:28.691Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31170 (GCVE-0-2023-31170)

    Vulnerability from nvd – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:49
    VLAI
    Title
    Inclusion of Functionality from Untrusted Control Sphere
    Summary
    An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.823Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31170",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:07:23.936703Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:49:02.329Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\n\n\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-829",
                  "description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:32.665Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": " Inclusion of Functionality from Untrusted Control Sphere",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31170",
        "datePublished": "2023-08-31T15:30:32.665Z",
        "dateReserved": "2023-04-24T23:20:01.608Z",
        "dateUpdated": "2024-09-27T18:49:02.329Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31169 (GCVE-0-2023-31169)

    Vulnerability from nvd – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:49
    VLAI
    Title
    Improper Handling of Unicode Encoding
    Summary
    An Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-176 - Improper Handling of Unicode Encoding
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.771Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31169",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:07:42.711772Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:49:59.858Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-176",
                  "description": "CWE-176 Improper Handling of Unicode Encoding",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:23.541Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Improper Handling of Unicode Encoding",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31169",
        "datePublished": "2023-08-31T15:30:23.541Z",
        "dateReserved": "2023-04-24T23:20:01.608Z",
        "dateUpdated": "2024-09-27T18:49:59.858Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31168 (GCVE-0-2023-31168)

    Vulnerability from nvd – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:52
    VLAI
    Title
    Inclusion of Functionality from Untrusted Control Sphere
    Summary
    An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:26.170Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31168",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:07:54.773013Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:52:57.616Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003eAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\u003cbr\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\n\n\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-829",
                  "description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:14.809Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": " Inclusion of Functionality from Untrusted Control Sphere",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31168",
        "datePublished": "2023-08-31T15:30:14.809Z",
        "dateReserved": "2023-04-24T23:20:01.608Z",
        "dateUpdated": "2024-09-27T18:52:57.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31167 (GCVE-0-2023-31167)

    Vulnerability from nvd – Published: 2023-08-31 15:29 – Updated: 2024-09-27 18:55
    VLAI
    Title
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details. This issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Reid Wightman of Dragos
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:26.042Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dragos.com"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31167",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:09:16.861600Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:55:28.386Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5036 acSELerator Bay Screen Builder Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "1.0.49152.778",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal.\u003cbr\u003e\u003cbr\u003e\n\nSEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal.\n\n\n\nSEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details.\n\n\nThis issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-139",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-139 Relative Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:29:11.745Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://dragos.com"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31167",
        "datePublished": "2023-08-31T15:29:11.745Z",
        "dateReserved": "2023-04-24T23:19:33.137Z",
        "dateUpdated": "2024-09-27T18:55:28.386Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-10608 (GCVE-0-2018-10608)

    Vulnerability from nvd – Published: 2018-07-24 13:00 – Updated: 2024-09-16 16:42
    VLAI
    Summary
    SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - UNCONTROLLED RESOURCE CONSUMPTION ('RESOURCE EXHAUSTION') CWE-400
    Assigner
    Impacted products
    Date Public
    2018-07-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.150Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AcSELerator Architect",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.2.24.0 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-07-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-17T00:06:04.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-07-10T00:00:00",
              "ID": "CVE-2018-10608",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "AcSELerator Architect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "2.2.24.0 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schweitzer Engineering Laboratories, Inc."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02"
                },
                {
                  "name": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10608",
        "datePublished": "2018-07-24T13:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:42:59.382Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-34392 (GCVE-0-2023-34392)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:31 – Updated: 2024-10-01 16:59
    VLAI
    Title
    Missing Authentication for Critical Function
    Summary
    A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Andrea Palanca and Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:10:06.984Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-34392",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T16:59:13.785566Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T16:59:22.498Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-180",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-180 Exploiting Incorrectly Configured Access Control Security Levels"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:57.140Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-34392",
        "datePublished": "2023-08-31T15:31:57.140Z",
        "dateReserved": "2023-06-02T17:18:29.697Z",
        "dateUpdated": "2024-10-01T16:59:22.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-34391 (GCVE-0-2023-34391)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:31 – Updated: 2024-10-01 17:02
    VLAI
    Title
    Insecure Inherited Permissions
    Summary
    Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-277 - Insecure Inherited Permissions
    Assigner
    SEL
    Impacted products
    Vendor Product Version
    Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software Affected: 0 , < 1.35.151.21000 (custom)
    Create a notification for this product.
    schweitzer_engineering_laboratories sel-5033_acselerator_rtac_software Affected: 0 , < 1.35.151.21000 (custom)
        cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-08-31 16:00
    Credits
    Reid Wightman of Dragos
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T16:10:07.006Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dragos.com"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "sel-5033_acselerator_rtac_software",
                "vendor": "schweitzer_engineering_laboratories",
                "versions": [
                  {
                    "lessThan": "1.35.151.21000",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-34391",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T16:59:56.064084Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T17:02:03.948Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5033 AcSELerator RTAC Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "1.35.151.21000",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths.\u003cbr\u003e\u003cbr\u003eSee Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details.\u003cbr\u003e \u003cbr\u003eThis issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000.\u003cp\u003e\u003c/p\u003e"
                }
              ],
              "value": "Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths.\n\nSee Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details.\n \nThis issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-38",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-38 Leveraging/Manipulating Configuration File Search Paths"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-277",
                  "description": "CWE-277: Insecure Inherited Permissions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:45.454Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://dragos.com"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Insecure Inherited Permissions",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-34391",
        "datePublished": "2023-08-31T15:31:45.454Z",
        "dateReserved": "2023-06-02T17:18:29.697Z",
        "dateUpdated": "2024-10-01T17:02:03.948Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31175 (GCVE-0-2023-31175)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:31 – Updated: 2024-10-01 17:03
    VLAI
    Title
    Execution with Unnecessary Privileges
    Summary
    An Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-250 - Execution with Unnecesary Privileges
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Andrea Palanca of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.726Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31175",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T17:03:22.630108Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T17:03:31.524Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Andrea Palanca of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Execution with Unnecessary Privileges vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run system commands with the highest level privilege on the system.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-122",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-122 Privilege Abuse"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-250",
                  "description": "CWE-250 Execution with Unnecesary Privileges",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:33.536Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Execution with Unnecessary Privileges",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31175",
        "datePublished": "2023-08-31T15:31:33.536Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-10-01T17:03:31.524Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31174 (GCVE-0-2023-31174)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:31 – Updated: 2024-09-30 15:47
    VLAI
    Title
    Cross-Site Request Forgery (CSRF)
    Summary
    A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-352 - Cross-Site Request Forgery (CSRF)
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Andrea Palanca of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.824Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31174",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-30T15:44:33.294603Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-30T15:47:25.305Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Andrea Palanca of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nA Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "\nA Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-62",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-62 Cross Site Request Forgery"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-352",
                  "description": "CWE-352 Cross-Site Request Forgery (CSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:31:26.657Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Cross-Site Request Forgery (CSRF)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31174",
        "datePublished": "2023-08-31T15:31:26.657Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-09-30T15:47:25.305Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31173 (GCVE-0-2023-31173)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:30 – Updated: 2024-10-01 17:21
    VLAI
    Title
    Use of Hard-coded Credentials
    Summary
    Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-798 - Use of Hard-coded Credentials
    Assigner
    SEL
    Impacted products
    Vendor Product Version
    Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator Affected: 0 , < 4.5.0.20 (custom)
    Create a notification for this product.
    schweitzer_engineering_laboratories sel-5033_acselerator_rtac_software Affected: 0 , < 4.5.0.20 (custom)
        cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.747Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:schweitzer_engineering_laboratories:sel-5033_acselerator_rtac_software:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "sel-5033_acselerator_rtac_software",
                "vendor": "schweitzer_engineering_laboratories",
                "versions": [
                  {
                    "lessThan": "4.5.0.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31173",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T17:20:11.993761Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T17:21:39.818Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5037 SEL Grid Configurator",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "4.5.0.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass.\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\u003c/p\u003e"
                }
              ],
              "value": "Use of Hard-coded Credentials vulnerability in Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator on Windows allows Authentication Bypass.\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-798",
                  "description": "CWE-798 Use of Hard-coded Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:58.262Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Use of Hard-coded Credentials",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31173",
        "datePublished": "2023-08-31T15:30:58.262Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-10-01T17:21:39.818Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31172 (GCVE-0-2023-31172)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:42
    VLAI
    Title
    Incomplete Filtering of Special Elements
    Summary
    An Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-791 - Incomplete Filtering of Special Elements
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.755Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31172",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:05:16.595821Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:42:58.512Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Incomplete Filtering of Special Elements vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-791",
                  "description": "CWE-791: Incomplete Filtering of Special Elements",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:49.213Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Incomplete Filtering of Special Elements",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31172",
        "datePublished": "2023-08-31T15:30:49.213Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-09-27T18:42:58.512Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31171 (GCVE-0-2023-31171)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:48
    VLAI
    Title
    Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Summary
    An Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.875Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31171",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:06:44.809247Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:48:28.691Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:41.030Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31171",
        "datePublished": "2023-08-31T15:30:41.030Z",
        "dateReserved": "2023-04-24T23:20:01.609Z",
        "dateUpdated": "2024-09-27T18:48:28.691Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31170 (GCVE-0-2023-31170)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:49
    VLAI
    Title
    Inclusion of Functionality from Untrusted Control Sphere
    Summary
    An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.823Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31170",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:07:23.936703Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:49:02.329Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\u003cbr\u003e\n\n\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-829",
                  "description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:32.665Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": " Inclusion of Functionality from Untrusted Control Sphere",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31170",
        "datePublished": "2023-08-31T15:30:32.665Z",
        "dateReserved": "2023-04-24T23:20:01.608Z",
        "dateUpdated": "2024-09-27T18:49:02.329Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31169 (GCVE-0-2023-31169)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:49
    VLAI
    Title
    Improper Handling of Unicode Encoding
    Summary
    An Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-176 - Improper Handling of Unicode Encoding
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:25.771Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31169",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:07:42.711772Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:49:59.858Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\nAn Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-176",
                  "description": "CWE-176 Improper Handling of Unicode Encoding",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:23.541Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Improper Handling of Unicode Encoding",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31169",
        "datePublished": "2023-08-31T15:30:23.541Z",
        "dateReserved": "2023-04-24T23:20:01.608Z",
        "dateUpdated": "2024-09-27T18:49:59.858Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31168 (GCVE-0-2023-31168)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:30 – Updated: 2024-09-27 18:52
    VLAI
    Title
    Inclusion of Functionality from Untrusted Control Sphere
    Summary
    An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Gabriele Quagliarella of Nozomi Networks
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:26.170Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.nozominetworks.com/blog/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31168",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:07:54.773013Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:52:57.616Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5030 acSELerator QuickSet Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThanOrEqual": "7.1.3.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Gabriele Quagliarella of Nozomi Networks"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cp\u003eAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\u003cbr\u003e\u003cbr\u003e\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\u003cbr\u003e\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\n\n\u003cp\u003eThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\u003c/p\u003e"
                }
              ],
              "value": "\nAn Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\n\n\n\n\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-549",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-549 Local Execution of Code"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-829",
                  "description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:30:14.809Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://www.nozominetworks.com/blog/"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": " Inclusion of Functionality from Untrusted Control Sphere",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31168",
        "datePublished": "2023-08-31T15:30:14.809Z",
        "dateReserved": "2023-04-24T23:20:01.608Z",
        "dateUpdated": "2024-09-27T18:52:57.616Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-31167 (GCVE-0-2023-31167)

    Vulnerability from cvelistv5 – Published: 2023-08-31 15:29 – Updated: 2024-09-27 18:55
    VLAI
    Title
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Summary
    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details. This issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    SEL
    Impacted products
    Date Public
    2023-08-31 16:00
    Credits
    Reid Wightman of Dragos
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T14:45:26.042Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://selinc.com/support/security-notifications/external-reports/"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://dragos.com"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-31167",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-09-27T18:09:16.861600Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-09-27T18:55:28.386Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "SEL-5036 acSELerator Bay Screen Builder Software",
              "vendor": "Schweitzer Engineering Laboratories",
              "versions": [
                {
                  "lessThan": "1.0.49152.778",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Reid Wightman of Dragos"
            }
          ],
          "datePublic": "2023-08-31T16:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal.\u003cbr\u003e\u003cbr\u003e\n\nSEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778.\u003c/p\u003e"
                }
              ],
              "value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal.\n\n\n\nSEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details.\n\n\nThis issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-139",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-139 Relative Path Traversal"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-08-31T15:29:11.745Z",
            "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
            "shortName": "SEL"
          },
          "references": [
            {
              "url": "https://selinc.com/support/security-notifications/external-reports/"
            },
            {
              "url": "https://dragos.com"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "assignerShortName": "SEL",
        "cveId": "CVE-2023-31167",
        "datePublished": "2023-08-31T15:29:11.745Z",
        "dateReserved": "2023-04-24T23:19:33.137Z",
        "dateUpdated": "2024-09-27T18:55:28.386Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-10608 (GCVE-0-2018-10608)

    Vulnerability from cvelistv5 – Published: 2018-07-24 13:00 – Updated: 2024-09-16 16:42
    VLAI
    Summary
    SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required.
    Severity
    No CVSS data available.
    CWE
    • CWE-400 - UNCONTROLLED RESOURCE CONSUMPTION ('RESOURCE EXHAUSTION') CWE-400
    Assigner
    Impacted products
    Date Public
    2018-07-10 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T07:46:46.150Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "AcSELerator Architect",
              "vendor": "Schweitzer Engineering Laboratories, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.2.24.0 and prior"
                }
              ]
            }
          ],
          "datePublic": "2018-07-10T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-17T00:06:04.000Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "ics-cert@hq.dhs.gov",
              "DATE_PUBLIC": "2018-07-10T00:00:00",
              "ID": "CVE-2018-10608",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "AcSELerator Architect",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "2.2.24.0 and prior"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Schweitzer Engineering Laboratories, Inc."
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "UNCONTROLLED RESOURCE CONSUMPTION (\u0027RESOURCE EXHAUSTION\u0027) CWE-400"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02",
                  "refsource": "MISC",
                  "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-191-02"
                },
                {
                  "name": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html",
                  "refsource": "MISC",
                  "url": "http://packetstormsecurity.com/files/152951/SEL-AcSELerator-Architect-2.2.24-Denial-Of-Service.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2018-10608",
        "datePublished": "2018-07-24T13:00:00.000Z",
        "dateReserved": "2018-05-01T00:00:00.000Z",
        "dateUpdated": "2024-09-16T16:42:59.382Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",