All the vulnerabilites related to siemens - simatic_cp_1628_firmware
Vulnerability from fkie_nvd
Published
2023-10-10 11:15
Modified
2024-11-21 08:11
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "152B002C-C7B0-4891-9D78-0E2464D33B92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4D249133-0B8A-4587-B453-44852E3EAFC6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "23579942-1BD9-4D73-9AD7-0FA68E5FDFDA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B56820D-3842-4810-A9A9-F7F051C81374", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3B55E584-06BA-4E1C-93B0-004B506FCBF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*", "matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A397C5DD-6495-463D-8EEF-9F1325A0B6CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*", "matchCriteriaId": "597593D3-BCFD-40DF-A83C-18F9D134863B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en: \nSIMATIC CP 1604 (Todas las versiones), \nSIMATIC CP 1616 (Todas las versiones), \nSIMATIC CP 1623 (Todas las versiones), \nSIMATIC CP 1626 (Todas las versiones), \nSIMATIC CP 1628 (Todas las versiones). \nLa memoria del kernel de los dispositivos afectados est\u00e1 expuesta al modo de usuario a trav\u00e9s del acceso directo a la memoria (DMA), lo que podr\u00eda permitir a un atacante local con privilegios administrativos ejecutar c\u00f3digo arbitrario en el host system sin ninguna restricci\u00f3n." } ], "id": "CVE-2023-37194", "lastModified": "2024-11-21T08:11:10.030", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-10-10T11:15:11.903", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-284" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-10-10 11:15
Modified
2024-11-21 08:11
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "152B002C-C7B0-4891-9D78-0E2464D33B92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4D249133-0B8A-4587-B453-44852E3EAFC6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "23579942-1BD9-4D73-9AD7-0FA68E5FDFDA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B56820D-3842-4810-A9A9-F7F051C81374", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "3B55E584-06BA-4E1C-93B0-004B506FCBF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*", "matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "A397C5DD-6495-463D-8EEF-9F1325A0B6CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*", "matchCriteriaId": "597593D3-BCFD-40DF-A83C-18F9D134863B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en: \nSIMATIC CP 1604 (Todas las versiones), \nSIMATIC CP 1616 (Todas las versiones), \nSIMATIC CP 1623 (Todas las versiones), \nSIMATIC CP 1626 (Todas las versiones), \nSIMATIC CP 1628 (Todas las versiones). \nLos dispositivos afectados controlan insuficientemente el mapeo continuo de las solicitudes de acceso directo a la memoria (DMA). Esto podr\u00eda permitir que atacantes locales con privilegios administrativos provoquen una situaci\u00f3n de denegaci\u00f3n de servicio en el host. Se requiere un ciclo de energ\u00eda f\u00edsico para que el sistema vuelva a funcionar." } ], "id": "CVE-2023-37195", "lastModified": "2024-11-21T08:11:10.173", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 4.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2023-10-10T11:15:11.983", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
cve-2023-37194
Vulnerability from cvelistv5
Published
2023-10-10 10:21
Modified
2024-09-19 14:27
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:34.104Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1604_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1616_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1623_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1626_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1628_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37194", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-19T14:23:50.733459Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-19T14:27:20.089Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1628", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:22.914Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-37194", "datePublished": "2023-10-10T10:21:22.914Z", "dateReserved": "2023-06-28T13:43:44.254Z", "dateUpdated": "2024-09-19T14:27:20.089Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-37195
Vulnerability from cvelistv5
Published
2023-10-10 10:21
Modified
2024-09-19 14:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:34.179Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-37195", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-19T14:23:19.334165Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-19T14:23:36.338Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1628", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:24.004Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-37195", "datePublished": "2023-10-10T10:21:24.004Z", "dateReserved": "2023-06-28T13:43:44.254Z", "dateUpdated": "2024-09-19T14:23:36.338Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }