cve-2023-37195
Vulnerability from cvelistv5
Published
2023-10-10 10:21
Modified
2024-09-19 14:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf | Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:34.179Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-37195", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-19T14:23:19.334165Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-19T14:23:36.338Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1628", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:24.004Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-37195", "datePublished": "2023-10-10T10:21:24.004Z", "dateReserved": "2023-06-28T13:43:44.254Z", "dateUpdated": "2024-09-19T14:23:36.338Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-37195\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-10-10T11:15:11.983\",\"lastModified\":\"2023-10-16T18:31:17.237\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en: \\nSIMATIC CP 1604 (Todas las versiones), \\nSIMATIC CP 1616 (Todas las versiones), \\nSIMATIC CP 1623 (Todas las versiones), \\nSIMATIC CP 1626 (Todas las versiones), \\nSIMATIC CP 1628 (Todas las versiones). \\nLos dispositivos afectados controlan insuficientemente el mapeo continuo de las solicitudes de acceso directo a la memoria (DMA). Esto podr\u00eda permitir que atacantes locales con privilegios administrativos provoquen una situaci\u00f3n de denegaci\u00f3n de servicio en el host. Se requiere un ciclo de energ\u00eda f\u00edsico para que el sistema vuelva a funcionar.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"152B002C-C7B0-4891-9D78-0E2464D33B92\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6304FA24-F194-4EE2-95F5-35D086F82C01\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D249133-0B8A-4587-B453-44852E3EAFC6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA074FBE-1C3E-4441-8C51-52B555B85D9F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"23579942-1BD9-4D73-9AD7-0FA68E5FDFDA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B56820D-3842-4810-A9A9-F7F051C81374\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B55E584-06BA-4E1C-93B0-004B506FCBF3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"581EA284-EDD6-4EA5-96B2-67904D1D9DC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A397C5DD-6495-463D-8EEF-9F1325A0B6CF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"597593D3-BCFD-40DF-A83C-18F9D134863B\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.