Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2023-37194
Vulnerability from cvelistv5
Vendor | Product | Version | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CP 1604 |
Version: All versions |
||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T17:09:34.104Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1604_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1616_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1623_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1626_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cp_1628_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-37194", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-09-19T14:23:50.733459Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-19T14:27:20.089Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1623", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1628", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-10T10:21:22.914Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-37194", "datePublished": "2023-10-10T10:21:22.914Z", "dateReserved": "2023-06-28T13:43:44.254Z", "dateUpdated": "2024-09-19T14:27:20.089Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-37194\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2023-10-10T11:15:11.903\",\"lastModified\":\"2024-11-21T08:11:10.030\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en: \\nSIMATIC CP 1604 (Todas las versiones), \\nSIMATIC CP 1616 (Todas las versiones), \\nSIMATIC CP 1623 (Todas las versiones), \\nSIMATIC CP 1626 (Todas las versiones), \\nSIMATIC CP 1628 (Todas las versiones). \\nLa memoria del kernel de los dispositivos afectados est\u00e1 expuesta al modo de usuario a trav\u00e9s del acceso directo a la memoria (DMA), lo que podr\u00eda permitir a un atacante local con privilegios administrativos ejecutar c\u00f3digo arbitrario en el host system sin ninguna restricci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"152B002C-C7B0-4891-9D78-0E2464D33B92\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6304FA24-F194-4EE2-95F5-35D086F82C01\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D249133-0B8A-4587-B453-44852E3EAFC6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA074FBE-1C3E-4441-8C51-52B555B85D9F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"23579942-1BD9-4D73-9AD7-0FA68E5FDFDA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1B56820D-3842-4810-A9A9-F7F051C81374\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B55E584-06BA-4E1C-93B0-004B506FCBF3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"581EA284-EDD6-4EA5-96B2-67904D1D9DC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A397C5DD-6495-463D-8EEF-9F1325A0B6CF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"597593D3-BCFD-40DF-A83C-18F9D134863B\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
gsd-2023-37194
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2023-37194", "id": "GSD-2023-37194" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-37194" ], "details": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.", "id": "GSD-2023-37194", "modified": "2023-12-13T01:20:24.394933Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-37194", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC CP 1604", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIMATIC CP 1616", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIMATIC CP 1623", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIMATIC CP 1626", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } }, { "product_name": "SIMATIC CP 1628", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions." } ] }, "impact": { "cvss": [ { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-284", "lang": "eng", "value": "CWE-284: Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2023-37194" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-284" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-10-16T18:28Z", "publishedDate": "2023-10-10T11:15Z" } } }
ghsa-cjgq-qwc4-hf8h
Vulnerability from github
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.
{ "affected": [], "aliases": [ "CVE-2023-37194" ], "database_specific": { "cwe_ids": [ "CWE-284" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2023-10-10T11:15:11Z", "severity": "MODERATE" }, "details": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.", "id": "GHSA-cjgq-qwc4-hf8h", "modified": "2024-04-04T08:28:00Z", "published": "2023-10-10T12:32:12Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-37194" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
icsa-23-285-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Several SIMATIC CP devices contain direct memory access vulnerabilities that could allow an attacker to execute code, access the PROFINET network without restrictions or perform denial of service attacks.\n\nSiemens recommends specific countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-784849.json" }, { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-784849.html" }, { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" }, { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-784849.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-285-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-285-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-285-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC CP products", "tracking": { "current_release_date": "2023-10-10T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-285-01", "initial_release_date": "2023-10-10T00:00:00Z", "revision_history": [ { "date": "2023-10-10T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1604 (6GK1160-4AA01)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK1160-4AA01" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1604 (6GK1160-4AA01)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1616 (6GK1161-6AA02)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK1161-6AA02" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1616 (6GK1161-6AA02)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1623 (6GK1162-3AA00)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK1162-3AA00" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1623 (6GK1162-3AA00)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1626 (6GK1162-6AA01)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "6GK1162-6AA01" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1626 (6GK1162-6AA01)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1628 (6GK1162-8AA00)", "product_id": "5", "product_identification_helper": { "model_numbers": [ "6GK1162-8AA00" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1628 (6GK1162-8AA00)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-37194", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional accounts with admin rights.", "product_ids": [ "1", "2", "3", "4", "5" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5" ] } ], "title": "CVE-2023-37194" }, { "cve": "CVE-2023-37195", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional accounts with admin rights.", "product_ids": [ "1", "2", "3", "4", "5" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5" ] } ], "title": "CVE-2023-37195" } ] }
ICSA-23-285-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Several SIMATIC CP devices contain direct memory access vulnerabilities that could allow an attacker to execute code, access the PROFINET network without restrictions or perform denial of service attacks.\n\nSiemens recommends specific countermeasures for products where updates are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-784849.json" }, { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-784849.html" }, { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" }, { "category": "self", "summary": "SSA-784849: Direct Memory Access Vulnerabilities in SIMATIC CP Devices - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-784849.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-23-285-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2023/icsa-23-285-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-23-285-01 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens SIMATIC CP products", "tracking": { "current_release_date": "2023-10-10T00:00:00Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-23-285-01", "initial_release_date": "2023-10-10T00:00:00Z", "revision_history": [ { "date": "2023-10-10T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1604 (6GK1160-4AA01)", "product_id": "1", "product_identification_helper": { "model_numbers": [ "6GK1160-4AA01" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1604 (6GK1160-4AA01)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1616 (6GK1161-6AA02)", "product_id": "2", "product_identification_helper": { "model_numbers": [ "6GK1161-6AA02" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1616 (6GK1161-6AA02)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1623 (6GK1162-3AA00)", "product_id": "3", "product_identification_helper": { "model_numbers": [ "6GK1162-3AA00" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1623 (6GK1162-3AA00)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1626 (6GK1162-6AA01)", "product_id": "4", "product_identification_helper": { "model_numbers": [ "6GK1162-6AA01" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1626 (6GK1162-6AA01)" }, { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "SIMATIC CP 1628 (6GK1162-8AA00)", "product_id": "5", "product_identification_helper": { "model_numbers": [ "6GK1162-8AA00" ] } } } ], "category": "product_name", "name": "SIMATIC CP 1628 (6GK1162-8AA00)" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-37194", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional accounts with admin rights.", "product_ids": [ "1", "2", "3", "4", "5" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5" ] } ], "scores": [ { "cvss_v3": { "baseScore": 6.7, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5" ] } ], "title": "CVE-2023-37194" }, { "cve": "CVE-2023-37195", "cwe": { "id": "CWE-400", "name": "Uncontrolled Resource Consumption" }, "notes": [ { "category": "summary", "text": "Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.", "title": "Summary" } ], "product_status": { "known_affected": [ "1", "2", "3", "4", "5" ] }, "remediations": [ { "category": "mitigation", "details": "Ensure that only trusted persons have access to the system and avoid the configuration of additional accounts with admin rights.", "product_ids": [ "1", "2", "3", "4", "5" ] }, { "category": "no_fix_planned", "details": "Currently no fix is planned", "product_ids": [ "1", "2", "3", "4", "5" ] } ], "scores": [ { "cvss_v3": { "baseScore": 4.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1", "2", "3", "4", "5" ] } ], "title": "CVE-2023-37195" } ] }
WID-SEC-W-2023-2603
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Siemens SICAM ist eine Produktfamilie von SCADA-Systemen f\u00fcr den Betrieb von industriellen Prozessen.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SICAM ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren.", "title": "Angriff" }, { "category": "general", "text": "- BIOS/Firmware\n- Hardware Appliance", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-2603 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-2603.json" }, { "category": "self", "summary": "WID-SEC-2023-2603 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-2603" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-285795.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-784849.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-770890.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-134651.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-035466.html" } ], "source_lang": "en-US", "title": "Siemens SICAM: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-10-09T22:00:00.000+00:00", "generator": { "date": "2024-02-15T17:47:17.112+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2023-2603", "initial_release_date": "2023-10-09T22:00:00.000+00:00", "revision_history": [ { "date": "2023-10-09T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens SICAM A8000", "product": { "name": "Siemens SICAM A8000", "product_id": "T024199", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:a8000" } } }, { "category": "product_name", "name": "Siemens SICAM PAS", "product": { "name": "Siemens SICAM PAS", "product_id": "T030347", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:pas" } } }, { "category": "product_name", "name": "Siemens SICAM PQS", "product": { "name": "Siemens SICAM PQS", "product_id": "T030348", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:pqs" } } }, { "category": "product_name", "name": "Siemens SICAM CP", "product": { "name": "Siemens SICAM CP", "product_id": "T030349", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:cp" } } }, { "category": "product_name", "name": "Siemens SICAM HMI Comfort Outdoor Panels", "product": { "name": "Siemens SICAM HMI Comfort Outdoor Panels", "product_id": "T030350", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:hmi_comfort_outdoor_panels" } } }, { "category": "product_name", "name": "Siemens SICAM HMI KTP Mobile Panels", "product": { "name": "Siemens SICAM HMI KTP Mobile Panels", "product_id": "T030351", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:hmi_ktp_mobile_panels" } } }, { "category": "product_name", "name": "Siemens SICAM NET PC Software", "product": { "name": "Siemens SICAM NET PC Software", "product_id": "T030352", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:net_pc_software" } } } ], "category": "product_name", "name": "SICAM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-45205", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-45205" }, { "cve": "CVE-2023-42796", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-42796" }, { "cve": "CVE-2023-38640", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-38640" }, { "cve": "CVE-2023-37195", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-37195" }, { "cve": "CVE-2023-37194", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-37194" }, { "cve": "CVE-2023-36380", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-36380" }, { "cve": "CVE-2021-45117", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2021-45117" } ] }
wid-sec-w-2023-2603
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Siemens SICAM ist eine Produktfamilie von SCADA-Systemen f\u00fcr den Betrieb von industriellen Prozessen.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer oder lokaler Angreifer kann mehrere Schwachstellen in Siemens SICAM ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren.", "title": "Angriff" }, { "category": "general", "text": "- BIOS/Firmware\n- Hardware Appliance", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2023-2603 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2023/wid-sec-w-2023-2603.json" }, { "category": "self", "summary": "WID-SEC-2023-2603 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2023-2603" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-285795.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-784849.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-770890.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-134651.html" }, { "category": "external", "summary": "Siemens Security Advisory vom 2023-10-09", "url": "https://cert-portal.siemens.com/productcert/html/ssa-035466.html" } ], "source_lang": "en-US", "title": "Siemens SICAM: Mehrere Schwachstellen", "tracking": { "current_release_date": "2023-10-09T22:00:00.000+00:00", "generator": { "date": "2024-02-15T17:47:17.112+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2023-2603", "initial_release_date": "2023-10-09T22:00:00.000+00:00", "revision_history": [ { "date": "2023-10-09T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_name", "name": "Siemens SICAM A8000", "product": { "name": "Siemens SICAM A8000", "product_id": "T024199", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:a8000" } } }, { "category": "product_name", "name": "Siemens SICAM PAS", "product": { "name": "Siemens SICAM PAS", "product_id": "T030347", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:pas" } } }, { "category": "product_name", "name": "Siemens SICAM PQS", "product": { "name": "Siemens SICAM PQS", "product_id": "T030348", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:pqs" } } }, { "category": "product_name", "name": "Siemens SICAM CP", "product": { "name": "Siemens SICAM CP", "product_id": "T030349", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:cp" } } }, { "category": "product_name", "name": "Siemens SICAM HMI Comfort Outdoor Panels", "product": { "name": "Siemens SICAM HMI Comfort Outdoor Panels", "product_id": "T030350", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:hmi_comfort_outdoor_panels" } } }, { "category": "product_name", "name": "Siemens SICAM HMI KTP Mobile Panels", "product": { "name": "Siemens SICAM HMI KTP Mobile Panels", "product_id": "T030351", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:hmi_ktp_mobile_panels" } } }, { "category": "product_name", "name": "Siemens SICAM NET PC Software", "product": { "name": "Siemens SICAM NET PC Software", "product_id": "T030352", "product_identification_helper": { "cpe": "cpe:/h:siemens:sicam:net_pc_software" } } } ], "category": "product_name", "name": "SICAM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-45205", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-45205" }, { "cve": "CVE-2023-42796", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-42796" }, { "cve": "CVE-2023-38640", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-38640" }, { "cve": "CVE-2023-37195", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-37195" }, { "cve": "CVE-2023-37194", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-37194" }, { "cve": "CVE-2023-36380", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2023-36380" }, { "cve": "CVE-2021-45117", "notes": [ { "category": "description", "text": "Es existieren mehrere Schwachstellen in verschiedenen Siemens SICAM Ger\u00e4ten. Die Fehler bestehen unter anderem aufgrund von unsicheren Berechtigungen, einer hartkodierten ID, einem Directory Traversal und einem unzureichenden Control Mapping. Ein Angreifer kann diese Schwachstellen ausnutzen, um beliebigen Code auszuf\u00fchren, Sicherheitsma\u00dfnahmen zu umgehen, vertrauliche Informationen offenzulegen, einen Denial-of-Service-Zustand auszul\u00f6sen, seine Privilegien zu erweitern und Daten zu manipulieren. Die erfolgreiche Ausnutzung einiger dieser Schwachstellen erfordert eine Benutzerinteraktion oder erh\u00f6hte Privilegien." } ], "product_status": { "known_affected": [ "T030347", "T030349", "T030348", "T030350", "T024199", "T030352", "T030351" ] }, "release_date": "2023-10-09T22:00:00Z", "title": "CVE-2021-45117" } ] }
var-202310-0249
Vulnerability from variot
A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions. SIMATIC CP 1604 firmware, SIMATIC CP 1616 firmware, simatic cp 1623 Multiple Siemens products, including firmware, contain vulnerabilities related to access control.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC CP 1623, CP 1626 and CP 1628 are PCI express cards for connecting Industrial Ethernet. SIMATIC CP 1604 and CP 1616 are PCI/PCI-104 cards for connecting field devices to PROFINET Industrial Ethernet.
Siemens SIMATIC CP devices have an improper access control vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202310-0249", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic cp 1604", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1626", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1628", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1616", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1623", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": null }, { "model": "simatic cp 1626", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1616", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1623", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1604", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp 1628", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1604" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1616" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1623" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1626" }, { "model": "simatic cp", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "1628" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1623_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1623:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_cp_1628_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_cp_1628:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-37194" } ] }, "cve": "CVE-2023-37194", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "MULTIPLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 6.5, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 2.5, "id": "CNVD-2023-75576", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:M/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "productcert@siemens.com", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "OTHER", "availabilityImpact": "High", "baseScore": 6.7, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2023-014725", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "productcert@siemens.com", "id": "CVE-2023-37194", "trust": 1.0, "value": "MEDIUM" }, { "author": "OTHER", "id": "JVNDB-2023-014725", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2023-75576", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). The kernel memory of affected devices is exposed to user-mode via direct memory access (DMA) which could allow a local attacker with administrative privileges to execute arbitrary code on the host system without any restrictions. SIMATIC CP 1604 firmware, SIMATIC CP 1616 firmware, simatic cp 1623 Multiple Siemens products, including firmware, contain vulnerabilities related to access control.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC CP 1623, CP 1626 and CP 1628 are PCI express cards for connecting Industrial Ethernet. SIMATIC CP 1604 and CP 1616 are PCI/PCI-104 cards for connecting field devices to PROFINET Industrial Ethernet. \n\r\n\r\nSiemens SIMATIC CP devices have an improper access control vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2023-37194" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "CNVD", "id": "CNVD-2023-75576" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-37194", "trust": 3.2 }, { "db": "SIEMENS", "id": "SSA-784849", "trust": 2.4 }, { "db": "JVN", "id": "JVNVU98753493", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-23-285-01", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-014725", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-75576", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "id": "VAR-202310-0249", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" } ], "trust": 1.4846153599999998 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" } ] }, "last_update_date": "2023-12-26T22:42:00.103000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Improper Access Control Vulnerability of Siemens SIMATIC CP Devices", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/466711" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-284", "trust": 1.0 }, { "problemtype": "Inappropriate access control (CWE-284) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu98753493/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-37194" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-285-01" }, { "trust": 0.6, "url": "https://cert-portal.siemens.com/productcert/html/ssa-784849.html" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-75576" }, { "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "db": "NVD", "id": "CVE-2023-37194" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-13T00:00:00", "db": "CNVD", "id": "CNVD-2023-75576" }, { "date": "2023-12-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "date": "2023-10-10T11:15:11.903000", "db": "NVD", "id": "CVE-2023-37194" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-10-11T00:00:00", "db": "CNVD", "id": "CNVD-2023-75576" }, { "date": "2023-12-25T06:04:00", "db": "JVNDB", "id": "JVNDB-2023-014725" }, { "date": "2023-10-16T18:28:22.733000", "db": "NVD", "id": "CVE-2023-37194" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Access control vulnerabilities in multiple Siemens products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-014725" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.