Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F045C4-8DC2-4FA8-833D-B430EA26F2A0",
              "versionEndIncluding": "8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A75F15-8F47-4348-A85C-D94BBA8F9992",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F27A96F-58B7-492F-8CF7-DE04D4EDAAD8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23B89914-E5BA-4670-B692-092AE9FFE148",
              "versionEndIncluding": "7.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3D1A823-CE50-441F-B060-DA678DFE24FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "28A1BA01-7A92-4368-8A73-8FA47A08BC53",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):15.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "0256663E-3A97-4E99-995D-7446804DB496",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E07DBA91-379C-40F5-8C45-6EC302F5CA7D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.0 y versiones anteriores (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones anteriores a la versi\u00f3n V8.1 con WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (Todas las versiones anteriores a la versi\u00f3n V8.2 SP1 con WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a la versi\u00f3n V9.0 SP2 con WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (Todas las versiones), SIMATIC WinCC Runtime Professional V14 ( Todas las versiones anteriores a la versi\u00f3n V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Upd 3), SIMATIC WinCC V7.2 y anteriores (Todas las versiones), SIMATIC WinCC V7.3 (Todas las versiones anterior a la versi\u00f3n V7.3 Upd 19), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 Upd 3). Un atacante con acceso al archivo del proyecto podr\u00eda ejecutar comandos arbitrarios del sistema con los privilegios del servidor de base de datos local. La vulnerabilidad podr\u00eda ser explotada por un atacante con acceso al archivo del proyecto. La vulnerabilidad s\u00ed afecta la confidencialidad, integridad y disponibilidad del sistema afectado. En el momento de la publicaci\u00f3n del aviso, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad."
    }
  ],
  "id": "CVE-2019-10916",
  "lastModified": "2024-11-21T04:20:08.653",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-05-14T20:29:02.293",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2010-07-22 05:43
Modified
2024-11-21 01:17
Summary
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
References
cve@mitre.orghttp://ics-cert.us-cert.gov/advisories/ICSA-12-205-01Third Party Advisory, US Government Resource
cve@mitre.orghttp://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725Press/Media Coverage
cve@mitre.orghttp://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssrPress/Media Coverage
cve@mitre.orghttp://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/Press/Media Coverage
cve@mitre.orghttp://secunia.com/advisories/40682Broken Link
cve@mitre.orghttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&cNot Applicable
cve@mitre.orghttp://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1Broken Link
cve@mitre.orghttp://www.f-secure.com/weblog/archives/00001987.htmlThird Party Advisory
cve@mitre.orghttp://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspxBroken Link, Vendor Advisory
cve@mitre.orghttp://www.securityfocus.com/bid/41753Broken Link, Third Party Advisory, VDB Entry
cve@mitre.orghttp://www.vupen.com/english/advisories/2010/1893Broken Link
cve@mitre.orghttp://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22Exploit, Issue Tracking
cve@mitre.orghttp://www.wired.com/threatlevel/2010/07/siemens-scada/Press/Media Coverage, Third Party Advisory
cve@mitre.orghttps://exchange.xforce.ibmcloud.com/vulnerabilities/60587Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725Press/Media Coverage
af854a3a-2127-422b-91ae-364da2661108http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssrPress/Media Coverage
af854a3a-2127-422b-91ae-364da2661108http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/Press/Media Coverage
af854a3a-2127-422b-91ae-364da2661108http://secunia.com/advisories/40682Broken Link
af854a3a-2127-422b-91ae-364da2661108http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=en&objid=43876783&cNot Applicable
af854a3a-2127-422b-91ae-364da2661108http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127&16127&Language=en&PageIndex=1Broken Link
af854a3a-2127-422b-91ae-364da2661108http://www.f-secure.com/weblog/archives/00001987.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspxBroken Link, Vendor Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/41753Broken Link, Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://www.vupen.com/english/advisories/2010/1893Broken Link
af854a3a-2127-422b-91ae-364da2661108http://www.wilderssecurity.com/showpost.php?p=1712134&postcount=22Exploit, Issue Tracking
af854a3a-2127-422b-91ae-364da2661108http://www.wired.com/threatlevel/2010/07/siemens-scada/Press/Media Coverage, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://exchange.xforce.ibmcloud.com/vulnerabilities/60587Third Party Advisory, VDB Entry



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:6.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "9BD0EB37-CFA4-49AE-A952-1A4E2E2EE998",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "963E0E16-2A77-45C8-8708-46B4158C40D0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:6.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C026414-5F0C-48E7-A93D-12E2E33AB6CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "BD419DE7-CB43-42E7-ACCC-82EA4913E8D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "036B082A-1B48-4BA0-A915-4344C70E430D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7885AE5-023B-45BC-8E4A-CF796B5757C2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."
    },
    {
      "lang": "es",
      "value": "Siemens Simatic WinCC y sistemas PCS 7 SCADA utiliza una contrase\u00f1a no modificable en el c\u00f3digo, lo cual permite a usuarios locales acceder a una base de datos interna (back-end) y obtener privilegios, como se demuestra en julio de 2010 por el gusano Stuxnet, una vulnerabilidad diferente de CVE-2010-2568."
    }
  ],
  "id": "CVE-2010-2772",
  "lastModified": "2024-11-21T01:17:21.660",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.9,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 10.0,
        "obtainAllPrivilege": true,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2010-07-22T05:43:58.250",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Press/Media Coverage"
      ],
      "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Press/Media Coverage"
      ],
      "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Press/Media Coverage"
      ],
      "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "http://secunia.com/advisories/40682"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Not Applicable"
      ],
      "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://www.f-secure.com/weblog/archives/00001987.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/41753"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Broken Link"
      ],
      "url": "http://www.vupen.com/english/advisories/2010/1893"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Issue Tracking"
      ],
      "url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Press/Media Coverage",
        "Third Party Advisory"
      ],
      "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Press/Media Coverage"
      ],
      "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Press/Media Coverage"
      ],
      "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Press/Media Coverage"
      ],
      "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "http://secunia.com/advisories/40682"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Not Applicable"
      ],
      "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://www.f-secure.com/weblog/archives/00001987.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/41753"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "http://www.vupen.com/english/advisories/2010/1893"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Issue Tracking"
      ],
      "url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Press/Media Coverage",
        "Third Party Advisory"
      ],
      "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-05-14 20:29
Modified
2024-11-21 04:20
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F045C4-8DC2-4FA8-833D-B430EA26F2A0",
              "versionEndIncluding": "8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A75F15-8F47-4348-A85C-D94BBA8F9992",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F27A96F-58B7-492F-8CF7-DE04D4EDAAD8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23B89914-E5BA-4670-B692-092AE9FFE148",
              "versionEndIncluding": "7.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3D1A823-CE50-441F-B060-DA678DFE24FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "28A1BA01-7A92-4368-8A73-8FA47A08BC53",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):15.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "0256663E-3A97-4E99-995D-7446804DB496",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E07DBA91-379C-40F5-8C45-6EC302F5CA7D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.0 y anteriores (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones anteriores a la versi\u00f3n V8.1 con WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (Todas las versiones anteriores V8.2 SP1 con WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (Todas las versiones  anteriores a la versi\u00f3n V9.0 SP2 con WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones "
    }
  ],
  "id": "CVE-2019-10917",
  "lastModified": "2024-11-21T04:20:08.790",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 2.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-05-14T20:29:02.387",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-248"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-755"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2016-07-22 15:59
Modified
2024-11-21 02:54
Severity ?
Summary
Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "640FFC01-A0B7-466F-AE23-4BAEAADA4D7C",
              "versionEndIncluding": "7.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "441E574D-1A66-4D8B-A0C5-4CC03E1D89D1",
              "versionEndIncluding": "7.3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA2E9785-246F-496B-9139-02E2F4003352",
              "versionEndIncluding": "7.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "9B434F8E-7E14-4D76-AC55-A15EF8EC10FB",
              "versionEndIncluding": "8.1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_openpcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E38B1737-F40A-4278-8687-6928AE03B0C0",
              "versionEndIncluding": "8.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "9B434F8E-7E14-4D76-AC55-A15EF8EC10FB",
              "versionEndIncluding": "8.1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_openpcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A18AA81-7FC3-4977-AFC9-77920845C8B8",
              "versionEndIncluding": "8.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B62697B-2F75-44EA-A1F8-14BF9D1F99CC",
              "versionEndIncluding": "8.2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "7F133189-C3AB-4FFD-9B5C-F181CFE50671",
              "versionEndIncluding": "13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets."
    },
    {
      "lang": "es",
      "value": "Siemens SIMATIC WinCC en versiones anteriores a 7.3 Update 10 y 7.4 en versiones anteriores a Update 1, SIMATIC BATCH en versiones anteriores a 8.1 SP1 Update 9 seg\u00fan se distribuye en SIMATIC PCS 7 hasta la versi\u00f3n 8.1 SP1, SIMATIC OpenPCS 7 en versiones anteriores a 8.1 Update 3 seg\u00fan se distribuye en SIMATIC PCS 7 hasta la versi\u00f3n 8.1 SP1, SIMATIC OpenPCS 7 en versiones anteriores a 8.2 Update 1 seg\u00fan se distribuye en SIMATIC PCS 7 8.2 y SIMATIC WinCC Runtime Professional en versiones anteriores a 13 SP1 Update 9 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de paquetes manipulados."
    }
  ],
  "id": "CVE-2016-5743",
  "lastModified": "2024-11-21T02:54:56.297",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": true,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-07-22T15:59:00.147",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/92112"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1036441"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-208-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/92112"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securitytracker.com/id/1036441"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-208-01"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-05-14 20:29
Modified
2024-11-21 04:20
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F045C4-8DC2-4FA8-833D-B430EA26F2A0",
              "versionEndIncluding": "8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CDFAB4E-8D98-4484-A1E8-381E6BFBF9AD",
              "versionStartIncluding": "8.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23B89914-E5BA-4670-B692-092AE9FFE148",
              "versionEndIncluding": "7.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBFF6F62-695B-4AD3-8CD9-0923CBF6A95D",
              "versionStartIncluding": "7.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without \"Encrypted Communication\", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Ha sido identificada una vulnerabilidad en SIMATIC PCS 7 V8.0 y anteriores (Todas las versiones), SIMATIC PCS 7 V8.1 y m\u00e1s recientes (Todas las versiones), SIMATIC WinCC V7.2 y anteriores (Todas las versiones), SIMATIC WinCC V7.3 y m\u00e1s nuevos (todas las versiones). Un atacante con acceso de red a las instalaciones afectadas, que est\u00e1n configuradas sin la \"Comunicaci\u00f3n cifrada\", puede ejecutar c\u00f3digo arbitrario. La vulnerabilidad de la seguridad podr\u00eda ser explotada por un atacante no autenticado con acceso de red a la instalaci\u00f3n afectada. No se requiere la interacci\u00f3n del usuario para explotar esta vulnerabilidad de seguridad. La vulnerabilidad afecta la confidencialidad, la integridad y la disponibilidad del dispositivo. En el momento de la publicaci\u00f3n de asesoramiento, no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad."
    }
  ],
  "id": "CVE-2019-10922",
  "lastModified": "2024-11-21T04:20:09.473",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-05-14T20:29:02.763",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/108398"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/108398"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-306"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-03-10 20:15
Modified
2024-11-21 04:34
Summary
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "1CBF717A-B2D4-459C-894A-65622570645D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:9.0_update_1:*:*:*:*:*:*:*",
              "matchCriteriaId": "957DDF70-1837-4E92-A707-944AD6ED4304",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "E54F6E83-C353-44FB-9F37-C03DA344A5DC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "3E19D98B-B40A-4589-8C26-7722C25EEC63",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_1:*:*:*:*:*:*",
              "matchCriteriaId": "85CDD274-B2B4-4DB0-9917-C16B5D900006",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_2:*:*:*:*:*:*",
              "matchCriteriaId": "0B435D51-FFA2-4F19-9B51-404BB37D7F0D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_3:*:*:*:*:*:*",
              "matchCriteriaId": "AFBBC7D6-D1D4-452E-A744-B490CF002354",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_4:*:*:*:*:*:*",
              "matchCriteriaId": "98BC62E3-4C0B-481A-9274-B9C785F8FDC5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A75F15-8F47-4348-A85C-D94BBA8F9992",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "7AA0E077-AB19-473B-9454-8FED7188A2C4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "19EA3CAD-E7CB-412F-A2EA-86A81EC25425",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "885BA05F-BD8F-4DE9-BDD3-6C2C76418B05",
              "versionEndExcluding": "9.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "57073CE8-174E-429D-A721-AB14C7D16D4F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_1:*:*:*:*:*:*",
              "matchCriteriaId": "9589FF11-4F9B-40F6-A6C6-55405B9EE351",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_10:*:*:*:*:*:*",
              "matchCriteriaId": "1DB57B3A-C3B6-4E61-9DAE-B12CEA8CD093",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_11:*:*:*:*:*:*",
              "matchCriteriaId": "EA6B2933-9C44-480C-96DC-6DF8C88950AF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_12:*:*:*:*:*:*",
              "matchCriteriaId": "45097864-DD87-4587-997B-792F0175472B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_13:*:*:*:*:*:*",
              "matchCriteriaId": "2FB24A30-0F93-430D-817E-05E4594C8823",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_2:*:*:*:*:*:*",
              "matchCriteriaId": "25237B9A-2E51-4F17-BD75-04D245CCC51D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_3:*:*:*:*:*:*",
              "matchCriteriaId": "90643D49-9EFC-4B9A-99C8-266135DF2E00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_4:*:*:*:*:*:*",
              "matchCriteriaId": "AC4D7B24-91FF-4891-ABC3-683A6C72ADDA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_5:*:*:*:*:*:*",
              "matchCriteriaId": "D1DD77A4-1716-4793-AD73-79D04E3D2AEE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_6:*:*:*:*:*:*",
              "matchCriteriaId": "5E667123-6909-4DF2-8CEB-6E87E9FC48BC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_7:*:*:*:*:*:*",
              "matchCriteriaId": "04A5C76A-5D6D-47F8-BEF7-503F9A89AD18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_8:*:*:*:*:*:*",
              "matchCriteriaId": "E776629C-904C-49D6-BF3F-8520FA7D5DFA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_9:*:*:*:*:*:*",
              "matchCriteriaId": "805DAA15-03A3-4F63-90F7-EA130E5136F2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:-:*:*:*:*:*",
              "matchCriteriaId": "00A48A8E-C112-4778-8A7B-2386E88A0177",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "D3D10C7E-5FD5-4B37-884B-B450DE5F800B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D9FE447-2090-47D2-8667-5DC7605089BB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BB4FFADC-51F0-439F-9F80-D2B2614FFC39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:14.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE5A7162-F1B5-4E74-99D6-4108AC4C49FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "50B77C2A-4D66-4407-8CA4-99C43ED72DDB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "9794ED7E-EB17-4C95-B900-840A48758F03",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:*",
              "matchCriteriaId": "57E82CFE-4191-4055-A0BA-EAB7BE96D947",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:*",
              "matchCriteriaId": "C4DBBDAA-BCAE-4B63-BDFC-3DD70DAD9B7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:*",
              "matchCriteriaId": "B5AF87C6-F8D6-4462-9DF5-B9D301002B1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "A4316924-9EF8-4835-A2E4-0C81F4DE473D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd12), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions \u003c V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions \u003c V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en OpenPCS 7 V8.1 (Todas las versiones), OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a V9.0 Upd3), SIMATIC BATCH V8.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones anteriores a V9. 0 SP1 Upd5), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC PCS 7 V8.1 (Todas las versiones), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9. 0 SP3), SIMATIC Route Control V8.1 (Todas las versiones), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones anteriores a V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones anteriores a V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15. 1 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC WinCC V7.3 (Todas las versiones), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP1 Update 1). A trav\u00e9s de mensajes especialmente dise\u00f1ados, cuando la comunicaci\u00f3n cifrada est\u00e1 habilitada, un atacante con acceso a la red podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del sistema causando una condici\u00f3n de denegaci\u00f3n de servicio. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario"
    }
  ],
  "id": "CVE-2019-19282",
  "lastModified": "2024-11-21T04:34:29.480",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2020-03-10T20:15:18.960",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-131"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-05-20 13:15
Modified
2024-11-21 06:50
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA18372-7E7D-4C51-8FA0-EE193DECB88D",
              "versionEndIncluding": "9.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "8852CFC7-FE90-4654-9F85-9181884F948E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA2E9785-246F-496B-9139-02E2F4003352",
              "versionEndIncluding": "7.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "3422B714-DB0F-4EE3-A7D4-9A0165214563",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*",
              "matchCriteriaId": "70B79B00-F61D-4F10-AD7B-74718F061D9E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*",
              "matchCriteriaId": "A8766442-CC8D-4221-89B8-F75D195F71E8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*",
              "matchCriteriaId": "26C08FB9-AFEB-4A53-AAB3-37C9717B30C5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*",
              "matchCriteriaId": "68896900-7FCC-4BFB-B787-8992B459F00D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update5:*:*:*:*:*:*",
              "matchCriteriaId": "1059B529-02F0-4C85-A35E-2282546FA990",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update6:*:*:*:*:*:*",
              "matchCriteriaId": "938D44C5-7B26-4400-970D-B3AA50DDD055",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update7:*:*:*:*:*:*",
              "matchCriteriaId": "E9E28D92-0643-4967-94C5-8B8F414158A3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC34D005-A65F-4AFE-BF1F-53A5AC950A22",
              "versionEndIncluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:17:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B76C5CC-652F-4117-8214-E219C12AA082",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V9.0 y anteriores (Todas las versiones), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 y anteriores (Todas las versiones), SIMATIC WinCC Runtime Professional V17 (Todas las versiones anteriores V17 Upd4), SIMATIC WinCC V7.4 y anteriores (Todas las versiones), SIMATIC WinCC V7.5 (Todas las versiones anteriores V7.5 SP2 Update 8). Un atacante autenticado podr\u00eda escapar del modo quiosco de WinCC abriendo el cuadro de di\u00e1logo de la impresora en la aplicaci\u00f3n afectada en caso de que no haya ninguna impresora instalada"
    }
  ],
  "id": "CVE-2022-24287",
  "lastModified": "2024-11-21T06:50:05.667",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-05-20T13:15:14.680",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1188"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1188"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-02-13 09:15
Modified
2024-11-21 08:31
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1350C78-30BE-4FA0-BE95-7A897C0D1927",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA5C1EC7-2F78-400D-9F85-FCEF71C4F1D5",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDA0756E-97B0-4896-BED4-44E86D6C76DE",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0AF2A6B-2A46-4147-AB1C-6E4DD71CD8C2",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E57C7724-EEDA-4F6E-8634-65B10C3319A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "872A881A-22F6-47E0-99ED-A83D9F77DB02",
              "versionEndIncluding": "18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*",
              "matchCriteriaId": "18D1C8AC-6A32-4ABB-A52D-58B774A5C9BE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en: \nOpenPCS 7 V9.1 (todas las versiones), \nSIMATIC BATCH V9.1 (todas las versiones), \nSIMATIC PCS 7 V9.1 (todas las versiones), \nSIMATIC Route Control V9.1 (todas las versiones), \nSIMATIC WinCC Runtime Professional V18 (todas las versiones), \nSIMATIC WinCC Runtime Professional V19 (todas las versiones), \nSIMATIC WinCC V7.4 (todas las versiones), \nSIMATIC WinCC V7.5 (todas las versiones \u0026lt; V7.5 SP2 Update 15), \nSIMATIC WinCC V8.0 (Todas las versiones "
    }
  ],
  "id": "CVE-2023-48364",
  "lastModified": "2024-11-21T08:31:34.503",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "NONE",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-13T09:15:45.980",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-06-13 09:15
Modified
2024-11-21 07:50
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-pm:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF831319-8E52-4A2A-9862-797DA0CB9952",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "482AD17F-916A-4DCC-8FAC-9D1716D04DD3",
              "versionEndExcluding": "5.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions \u003c V9.1 SP2 UC04), SIMATIC S7-PM (All versions \u003c V5.7 SP1 HF1), SIMATIC S7-PM (All versions \u003c V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions \u003c V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.\r\n\r\nAn attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system\u0027s server."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 (todas las versiones \u0026lt; V9.1 SP2 UC04), SIMATIC S7-PM (todas las versiones), SIMATIC STEP 7 V5 (todas las versiones \u0026lt; V5.7). El producto afectado contiene un sistema de gesti\u00f3n de bases de datos que podr\u00eda permitir a usuarios remotos con pocos privilegios utilizar funciones integradas de la base de datos (local o en un recurso compartido de red) que tienen impacto en el servidor. Un atacante con acceso a la red del servidor podr\u00eda aprovechar estas funciones integradas para ejecutar c\u00f3digo con privilegios elevados en el servidor del sistema de administraci\u00f3n de bases de datos."
    }
  ],
  "id": "CVE-2023-25910",
  "lastModified": "2024-11-21T07:50:24.710",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 10.0,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-06-13T09:15:16.280",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-09 16:15
Modified
2024-11-21 06:23
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B62697B-2F75-44EA-A1F8-14BF9D1F99CC",
              "versionEndIncluding": "8.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D25510C-F677-4A98-806C-FF644F11EEC6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F39B396-140B-4005-9A61-F984C9FAF742",
              "versionEndExcluding": "7.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*",
              "matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*",
              "matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*",
              "matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*",
              "matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update14:*:*:*:*:*:*",
              "matchCriteriaId": "3C5F5AD3-878D-42B0-B30E-8B0B6174486B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update15:*:*:*:*:*:*",
              "matchCriteriaId": "57F59EE1-46FC-4B94-AB30-F1D3235C5A1D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update16:*:*:*:*:*:*",
              "matchCriteriaId": "BA774F51-885C-4579-982E-431A8AB027B7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update17:*:*:*:*:*:*",
              "matchCriteriaId": "110DF98C-BE75-43B6-B63D-1D7D99AFFA73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update18:*:*:*:*:*:*",
              "matchCriteriaId": "11F812DE-BF33-4CB0-8E21-81682E3B88CA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*",
              "matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*",
              "matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*",
              "matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*",
              "matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*",
              "matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*",
              "matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*",
              "matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "3422B714-DB0F-4EE3-A7D4-9A0165214563",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*",
              "matchCriteriaId": "70B79B00-F61D-4F10-AD7B-74718F061D9E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*",
              "matchCriteriaId": "A8766442-CC8D-4221-89B8-F75D195F71E8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*",
              "matchCriteriaId": "26C08FB9-AFEB-4A53-AAB3-37C9717B30C5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*",
              "matchCriteriaId": "68896900-7FCC-4BFB-B787-8992B459F00D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update5:*:*:*:*:*:*",
              "matchCriteriaId": "1059B529-02F0-4C85-A35E-2282546FA990",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D9FE447-2090-47D2-8667-5DC7605089BB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BB4FFADC-51F0-439F-9F80-D2B2614FFC39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "4C117FFB-A3FF-4E82-9CE9-B2DFFAF7D799",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:14.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE5A7162-F1B5-4E74-99D6-4108AC4C49FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:*:*:*:*",
              "matchCriteriaId": "A961C560-0288-4BC7-B3EB-11610765A34A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "50B77C2A-4D66-4407-8CA4-99C43ED72DDB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "9794ED7E-EB17-4C95-B900-840A48758F03",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:*",
              "matchCriteriaId": "57E82CFE-4191-4055-A0BA-EAB7BE96D947",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:*",
              "matchCriteriaId": "C4DBBDAA-BCAE-4B63-BDFC-3DD70DAD9B7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:*",
              "matchCriteriaId": "B5AF87C6-F8D6-4462-9DF5-B9D301002B1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_5:*:*:*:*:*:*",
              "matchCriteriaId": "E4D610DA-D1EF-487E-94CB-FC6E6BE4BE4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_6:*:*:*:*:*:*",
              "matchCriteriaId": "6BB49DC6-B8AB-4320-B5CB-8EB803D41194",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "A4316924-9EF8-4835-A2E4-0C81F4DE473D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "A1011EBE-A08D-4066-A2B8-45736AE6999B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "37284D6C-ADB9-43A9-817D-7879FDF8BF7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "1DAD73CB-A027-4CEA-A439-A271717BBEDD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*",
              "matchCriteriaId": "150B957C-545F-4BD8-8AB9-E64ACC59C865",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:-:*:*:*:*:*:*",
              "matchCriteriaId": "C665E91E-DC56-41E0-99B4-ACFAA70B3103",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*",
              "matchCriteriaId": "BB46C8BD-942A-45DC-AA8A-C0D9418CA302",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 6). El hash de la contrase\u00f1a de una cuenta de usuario local en el servidor remoto podr\u00eda concederse a trav\u00e9s de la API p\u00fablica a un usuario del sistema afectado. Un atacante autenticado podr\u00eda forzar el hash de la contrase\u00f1a y utilizarlo para iniciar sesi\u00f3n en el servidor"
    }
  ],
  "id": "CVE-2021-40360",
  "lastModified": "2024-11-21T06:23:57.097",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 4.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-09T16:15:13.813",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-11-09 12:15
Modified
2024-11-21 06:23
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A75F15-8F47-4348-A85C-D94BBA8F9992",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D25510C-F677-4A98-806C-FF644F11EEC6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*",
              "matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*",
              "matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*",
              "matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*",
              "matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update14:*:*:*:*:*:*",
              "matchCriteriaId": "3C5F5AD3-878D-42B0-B30E-8B0B6174486B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update15:*:*:*:*:*:*",
              "matchCriteriaId": "57F59EE1-46FC-4B94-AB30-F1D3235C5A1D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update16:*:*:*:*:*:*",
              "matchCriteriaId": "BA774F51-885C-4579-982E-431A8AB027B7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update17:*:*:*:*:*:*",
              "matchCriteriaId": "110DF98C-BE75-43B6-B63D-1D7D99AFFA73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update18:*:*:*:*:*:*",
              "matchCriteriaId": "11F812DE-BF33-4CB0-8E21-81682E3B88CA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*",
              "matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*",
              "matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*",
              "matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*",
              "matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*",
              "matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*",
              "matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*",
              "matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "D0A0534C-8EDE-46FF-82A0-812CF069ABC9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "3422B714-DB0F-4EE3-A7D4-9A0165214563",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*",
              "matchCriteriaId": "70B79B00-F61D-4F10-AD7B-74718F061D9E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*",
              "matchCriteriaId": "A8766442-CC8D-4221-89B8-F75D195F71E8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*",
              "matchCriteriaId": "26C08FB9-AFEB-4A53-AAB3-37C9717B30C5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*",
              "matchCriteriaId": "68896900-7FCC-4BFB-B787-8992B459F00D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:*:*:*:*",
              "matchCriteriaId": "A961C560-0288-4BC7-B3EB-11610765A34A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "50B77C2A-4D66-4407-8CA4-99C43ED72DDB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "9794ED7E-EB17-4C95-B900-840A48758F03",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:*",
              "matchCriteriaId": "57E82CFE-4191-4055-A0BA-EAB7BE96D947",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:*",
              "matchCriteriaId": "C4DBBDAA-BCAE-4B63-BDFC-3DD70DAD9B7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:*",
              "matchCriteriaId": "B5AF87C6-F8D6-4462-9DF5-B9D301002B1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_5:*:*:*:*:*:*",
              "matchCriteriaId": "E4D610DA-D1EF-487E-94CB-FC6E6BE4BE4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_6:*:*:*:*:*:*",
              "matchCriteriaId": "6BB49DC6-B8AB-4320-B5CB-8EB803D41194",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "A1011EBE-A08D-4066-A2B8-45736AE6999B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "37284D6C-ADB9-43A9-817D-7879FDF8BF7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "1DAD73CB-A027-4CEA-A439-A271717BBEDD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*",
              "matchCriteriaId": "150B957C-545F-4BD8-8AB9-E64ACC59C865",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E848185-A7C7-4FD3-94DC-8D4092395752",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*",
              "matchCriteriaId": "BB46C8BD-942A-45DC-AA8A-C0D9418CA302",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 5). Las operaciones de archivo leg\u00edtimas en el servidor web de los sistemas afectados no neutralizan correctamente los elementos especiales dentro de la ruta de acceso. Un atacante podr\u00eda entonces hacer que el nombre de ruta se resuelva en una ubicaci\u00f3n fuera del directorio restringido en el servidor y leer, escribir o eliminar archivos cr\u00edticos inesperados"
    }
  ],
  "id": "CVE-2021-40358",
  "lastModified": "2024-11-21T06:23:56.737",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.9,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.1,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2021-11-09T12:15:09.930",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-06-10 17:15
Modified
2024-11-21 05:37
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_process_device_manager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50C02E17-87F5-47DB-B4F3-EFC44B0DFC88",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF09D6E-3375-4731-B16D-30B7592EA5FB",
              "versionEndExcluding": "5.6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:-:*:*:*:*:*:*",
              "matchCriteriaId": "851F8474-4568-487D-98FB-47DF7EAEAC3B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81EADA2F-884C-4D72-8489-71025B3EBAEE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "78366D2F-B728-47F6-B539-5FB2D1B0419D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2_hotfix1:*:*:*:*:*:*",
              "matchCriteriaId": "06A86DA0-BC1F-4306-B02E-ED2FA36BE273",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_starter:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23020179-5112-48A8-BA76-EB6C073867BF",
              "versionEndExcluding": "5.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_starter:5.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "E04348B3-6DAC-49E2-A612-FE0A3166776B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 y anteriores (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP3), SIMATIC PDM (Todas las versiones anteriores a V9.2), SIMATIC STEP 7 V5.X (Todas las versiones anteriores a V5.6 SP2 HF3), SINAMICS STARTER (que contiene la versi\u00f3n OEM de STEP 7) (Todas las versiones anteriores a V5.4 HF2). Una vulnerabilidad de Secuestro de DLL podr\u00eda permitir a un atacante local ejecutar c\u00f3digo con privilegios elevados. La vulnerabilidad de seguridad podr\u00eda ser explotada por parte de un atacante con acceso local a los sistemas afectados. Una explotaci\u00f3n con \u00e9xito requiere privilegios de usuario pero no interacci\u00f3n del usuario. La vulnerabilidad podr\u00eda permitir a un atacante comprometer la disponibilidad del sistema, as\u00ed como tener acceso a informaci\u00f3n confidencial"
    }
  ],
  "id": "CVE-2020-7585",
  "lastModified": "2024-11-21T05:37:25.310",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-06-10T17:15:12.457",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-427"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2024-02-13 09:15
Modified
2024-11-21 08:31
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1350C78-30BE-4FA0-BE95-7A897C0D1927",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA5C1EC7-2F78-400D-9F85-FCEF71C4F1D5",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDA0756E-97B0-4896-BED4-44E86D6C76DE",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0AF2A6B-2A46-4147-AB1C-6E4DD71CD8C2",
              "versionEndIncluding": "9.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E57C7724-EEDA-4F6E-8634-65B10C3319A2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "872A881A-22F6-47E0-99ED-A83D9F77DB02",
              "versionEndIncluding": "18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*",
              "matchCriteriaId": "18D1C8AC-6A32-4ABB-A52D-58B774A5C9BE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en: \nOpenPCS 7 V9.1 (todas las versiones), \nSIMATIC BATCH V9.1 (todas las versiones), \nSIMATIC PCS 7 V9.1 (todas las versiones), \nSIMATIC Route Control V9.1 (todas las versiones), \nSIMATIC WinCC Runtime Professional V18 (todas las versiones), \nSIMATIC WinCC Runtime Professional V19 (todas las versiones), \nSIMATIC WinCC V7.4 (todas las versiones), \nSIMATIC WinCC V7.5 (todas las versiones \u0026lt; V7.5 SP2 Update 15), \nSIMATIC WinCC V8.0 (Todas las versiones "
    }
  ],
  "id": "CVE-2023-48363",
  "lastModified": "2024-11-21T08:31:34.337",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "ADJACENT",
          "automatable": "NOT_DEFINED",
          "availabilityRequirements": "NOT_DEFINED",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityRequirements": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirements": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubsequentSystemAvailability": "NOT_DEFINED",
          "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED",
          "modifiedSubsequentSystemIntegrity": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnerableSystemAvailability": "NOT_DEFINED",
          "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED",
          "modifiedVulnerableSystemIntegrity": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "recovery": "NOT_DEFINED",
          "safety": "NOT_DEFINED",
          "subsequentSystemAvailability": "NONE",
          "subsequentSystemConfidentiality": "NONE",
          "subsequentSystemIntegrity": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnerabilityResponseEffort": "NOT_DEFINED",
          "vulnerableSystemAvailability": "HIGH",
          "vulnerableSystemConfidentiality": "NONE",
          "vulnerableSystemIntegrity": "NONE"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-02-13T09:15:45.763",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2016-12-17 03:59
Modified
2024-11-21 03:00
Summary
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions.
Impacted products
Vendor Product Version
siemens simatic_pcs_7 *
siemens simatic_wincc *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F045C4-8DC2-4FA8-833D-B430EA26F2A0",
              "versionEndIncluding": "8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "71370ADD-85DC-407A-99F3-8F5386EBFBCE",
              "versionEndIncluding": "7.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en SIEMENS SIMATIC WinCC (Todas las versions \u003c SIMATIC WinCC V7.2) y SIEMENS SIMATIC PCS 7 (Todas las versiones \u003c SIMATIC PCS 7 V8.0 SP1) podr\u00eda permitir a un atacante remoto bloquear un componente ActiveX o filtrar partes de la memoria de aplicaci\u00f3n si un usuario es enga\u00f1ado para hacer clic en un enlace malicioso bajo ciertas condiciones."
    }
  ],
  "id": "CVE-2016-9160",
  "lastModified": "2024-11-21T03:00:43.387",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-12-17T03:59:00.263",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "http://www.securityfocus.com/bid/94825"
    },
    {
      "source": "productcert@siemens.com",
      "url": "http://www.securitytracker.com/id/1037435"
    },
    {
      "source": "productcert@siemens.com",
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/94825"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securitytracker.com/id/1037435"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-111"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-254"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-02-09 17:15
Modified
2024-11-21 04:54
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C32103C4-3706-47F0-B626-FA9EFB0643D1",
              "versionEndExcluding": "7.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 (todas las versiones), SIMATIC WinCC (todas las versiones anteriores a V7.5 SP2).\u0026#xa0;Debido a un proceso de verificaci\u00f3n de contrase\u00f1a no seguro, un atacante podr\u00eda omitir la protecci\u00f3n con contrase\u00f1a establecida en los archivos protegidos, obteniendo as\u00ed acceso al contenido protegido, evitando la autenticaci\u00f3n"
    }
  ],
  "id": "CVE-2020-10048",
  "lastModified": "2024-11-21T04:54:42.183",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-02-09T17:15:13.360",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-288"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2023-06-13 09:15
Modified
2024-11-21 07:56
Summary
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:14.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "34A1F08A-1269-44F0-8B10-70A41F9306B2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:15.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "79A56438-47FC-4184-9401-0B859037D0F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "3EEF9BE1-F6E2-4C05-8020-4D7540882464",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D25510C-F677-4A98-806C-FF644F11EEC6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7E53AD8-C669-4E1F-9519-4DED57668766",
              "versionEndExcluding": "8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinaut_st7sc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3C162C7-AC9A-44E3-BAE5-1C0D434F264B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions \u003c V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms \u0026 Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents."
    }
  ],
  "id": "CVE-2023-28829",
  "lastModified": "2024-11-21T07:56:06.343",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 3.9,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 3.4,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-06-13T09:15:16.707",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-477"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-06-10 17:15
Modified
2024-11-21 05:37
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_automatic_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A659B687-1038-42F5-B8AC-A394E41D22A8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "17BCC3CD-61D0-416D-A241-D35AF8EE5BF8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_prosave:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB7752CF-D754-4A78-999B-45FE379E03DE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "658E1A3F-29D6-48D2-BCCE-0BCC41AC49F6",
              "versionEndExcluding": "21.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF09D6E-3375-4731-B16D-30B7592EA5FB",
              "versionEndExcluding": "5.6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A3CA33C-AFAB-418F-870F-0236B8E55943",
              "versionEndIncluding": "16",
              "versionStartIncluding": "13",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:-:*:*:*:*:*:*",
              "matchCriteriaId": "851F8474-4568-487D-98FB-47DF7EAEAC3B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81EADA2F-884C-4D72-8489-71025B3EBAEE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "78366D2F-B728-47F6-B539-5FB2D1B0419D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2_hotfix1:*:*:*:*:*:*",
              "matchCriteriaId": "06A86DA0-BC1F-4306-B02E-ED2FA36BE273",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F39B396-140B-4005-9A61-F984C9FAF742",
              "versionEndExcluding": "7.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*",
              "matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*",
              "matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*",
              "matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*",
              "matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*",
              "matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*",
              "matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*",
              "matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*",
              "matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*",
              "matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*",
              "matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*",
              "matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9ED7EF-EF58-400F-92C9-3D52D8E39783",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.17:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C3F9210-7A1E-4B10-B384-119FD5733A86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C9253AD-BD82-4BB2-84AD-EB1892B60358",
              "versionEndIncluding": "16",
              "versionStartIncluding": "13",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_startdrive:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C11DB09A-74E1-45EF-A162-9C1E91F54C04",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_starter_commissioning_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1976CDDA-F2AF-4C47-804E-2C1DF44FBF41",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_network_management_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "52F7076E-12F7-4F62-9804-18598C39D3FF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_one_virtual:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A607E4B7-2F58-4F68-91EB-16874986E92F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_operate:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BAFC5C25-EC3C-4EB6-B5B2-478AE9CEF10F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versi\u00f3n V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versi\u00f3n V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versi\u00f3n V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versi\u00f3n V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versi\u00f3n V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versi\u00f3n V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versi\u00f3n V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versi\u00f3n V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versi\u00f3n V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versi\u00f3n V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versi\u00f3n V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versi\u00f3n V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versi\u00f3n V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versi\u00f3n V6.14). Un componente dentro de la aplicaci\u00f3n afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no est\u00e1 citada"
    }
  ],
  "id": "CVE-2020-7580",
  "lastModified": "2024-11-21T05:37:24.840",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-06-10T17:15:12.347",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-428"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-428"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2016-11-15 19:30
Modified
2024-11-21 02:57
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:primary_setup_tool:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8046A64D-4C80-4199-B1A7-F77D02428ACD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:security_configuration_tool:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C33765E4-619E-4566-BF96-4A7C8776A0CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBCAF7A5-CA65-4D88-8473-67947726CA2D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87DF85DE-B86C-459A-A9A9-096AF7A661E6",
              "versionEndIncluding": "14.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DFBFF6B-DBC8-451D-A235-4C7E1F0883D5",
              "versionEndIncluding": "7.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8B894F4-9635-4436-BC0A-E43280426017",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C6E8BBF-C5FF-4F13-AC70-2FF41CF3CC8E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "C60C6533-1875-4E5B-A367-F6C1C1345CCF",
              "versionEndIncluding": "5.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7_\\(tia_portal\\):*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4053231-D271-4A23-B0A0-374F6EAE2EF8",
              "versionEndIncluding": "14.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD93D757-C2DE-444C-9FF4-A7A700EFF7F0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "042D7AB5-8DB7-478E-8CB8-31942D360B34",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "B9D3442E-E362-49BA-8699-629A611A6E2E",
              "versionEndIncluding": "7.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C4BFBED-E818-453C-B787-22D67B4A5A29",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "882F53D9-7AAA-4647-B071-A45CA2618AA1",
              "versionEndIncluding": "14.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:basic:*:*:*",
              "matchCriteriaId": "F4524CA7-833B-4577-A5E5-DB47704F49AF",
              "versionEndIncluding": "14.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:comfort:*:*:*",
              "matchCriteriaId": "58782A2B-6A27-475A-9FAB-0272DED5DB40",
              "versionEndIncluding": "14.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):-:*:*:*:professional:*:*:*",
              "matchCriteriaId": "D9BA6A34-593E-466A-B11B-1E2DC890ECF6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:professional:*:*:*",
              "matchCriteriaId": "E6BFBAED-EE2B-4DE4-A76C-824DD15F4608",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simit:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "939DE56D-D8D7-42B8-BC0C-D6727E99AFA3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9646F056-080A-4F45-AABD-4D6E8AF05148",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:*:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "3F8B6E52-C339-41B9-A2C1-A6D161251648",
              "versionEndIncluding": "13.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:softnet_security_client:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18BFF869-4E4E-4410-91F7-56A7E959C0FE",
              "versionEndIncluding": "5.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_basic:*:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "A9386816-33A5-4DA7-931B-841AAE40E3BE",
              "versionEndIncluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versi\u00f3n V7.1 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.0 (Todas las versiones), SIMATIC PCS 7 versi\u00f3n V8.1 (Todas las versiones),SIMATIC PCS 7 versi\u00f3n V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versi\u00f3n V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versi\u00f3n V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versi\u00f3n V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versi\u00f3n V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versi\u00f3n V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versi\u00f3n V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versi\u00f3n V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versi\u00f3n V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versi\u00f3n V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podr\u00edan permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no est\u00e1n instalados en su ruta (path) de acceso predeterminada (\"C:\\Program Files\\*\" o el equivalente localizado)."
    }
  ],
  "id": "CVE-2016-7165",
  "lastModified": "2024-11-21T02:57:37.740",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.9,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 0.5,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-11-15T19:30:02.797",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/94158"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/94158"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-254"
        },
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-07-13 11:15
Modified
2024-11-21 06:06
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "943D8B33-182B-4E6F-9318-D7AEC1CB09C5",
              "versionEndIncluding": "8.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_firmware:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF59BB59-530E-41D7-8D5B-090C0FDBDDB1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pcs_7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EEFB170-B4B0-4A0E-8828-9491446033A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "311060D9-5691-4C4C-9CB6-14F25CBA4DB0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_step_7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CE4FB98-0276-4573-BAD7-04CE7F7E025E",
              "versionEndExcluding": "5.7",
              "versionStartIncluding": "5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_step_7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB1FE00B-0613-4819-8D50-A5A0B6A190D1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_starter_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ACF25F6B-8DC4-4835-AE2F-2E03D3FA4C8C",
              "versionEndExcluding": "5.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_starter_firmware:5.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "4D01AB88-A23C-4105-9D5C-DEAA8C2AAFE9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_starter_firmware:5.4:hf1:*:*:*:*:*:*",
              "matchCriteriaId": "F5953F96-3995-4974-9D73-EA32BF4DE53B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_starter_firmware:5.4:hf2:*:*:*:*:*:*",
              "matchCriteriaId": "D8793ACD-F4C9-4954-856A-ECB57A2BE990",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_starter_firmware:5.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "FABF5C1B-F79B-4CB4-9340-A0D61EF151A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_starter_firmware:5.4:sp1_hf1:*:*:*:*:*:*",
              "matchCriteriaId": "104FAEB7-9C81-49B2-8F06-7E5FDA87BD98",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_starter_firmware:5.4:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "5973C248-327A-44C4-B913-1327270E64D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_starter:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3E8B354-CB0D-40F1-BC2B-C2355974C2A9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions \u003c V9.1 SP2), SIMATIC PDM (All versions \u003c V9.2 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 SP2 HF1). A directory containing metafiles relevant to devices\u0027 configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 y anteriores (Todas las versiones), SIMATIC PCS 7 V9.X (Todas las versiones anteriores a V9.1 SP2), SIMATIC PDM (Todas las versiones anteriores a V9.2 SP2), SIMATIC STEP 7 V5.X (Todas las versiones anteriores a V5.7), SINAMICS STARTER (que contiene la versi\u00f3n OEM de STEP 7) (Todas las versiones anteriores a V5.4 SP2 HF1). Un directorio que contiene metafichas relevantes para las configuraciones de los dispositivos tiene permisos de escritura. Un atacante podr\u00eda aprovechar esta vulnerabilidad cambiando el contenido de ciertos metaficheros y posteriormente manipular los par\u00e1metros o el comportamiento de los dispositivos que posteriormente ser\u00edan configurados por el software afectado"
    }
  ],
  "id": "CVE-2021-31894",
  "lastModified": "2024-11-21T06:06:27.113",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.0,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-07-13T11:15:09.603",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-07-11 22:15
Modified
2024-11-21 04:20
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3566C20F-A4A7-494F-AAD2-A11B0AD783D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A75F15-8F47-4348-A85C-D94BBA8F9992",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F27A96F-58B7-492F-8CF7-DE04D4EDAAD8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23B89914-E5BA-4670-B692-092AE9FFE148",
              "versionEndIncluding": "7.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:-:*:*:*:*:*:*",
              "matchCriteriaId": "AE3690D0-60A7-4E52-A36A-ADBA01F8D99F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "AEFFC1F1-4376-4D6F-960C-9B692756EC45",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_10:*:*:*:*:*:*",
              "matchCriteriaId": "C53072DB-8097-44B6-A77B-C461AF96E527",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_11:*:*:*:*:*:*",
              "matchCriteriaId": "E8DFE502-A987-4DC3-93B5-4ED947CE4152",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_13:*:*:*:*:*:*",
              "matchCriteriaId": "7C7C1506-7E85-47A9-B940-FE77F64D3A64",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:update_4:*:*:*:*:*:*",
              "matchCriteriaId": "179AC2DA-AB33-4841-9F8A-54C823C98C6A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "D0A0534C-8EDE-46FF-82A0-812CF069ABC9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:professional:*:*:*",
              "matchCriteriaId": "D5946B53-3E14-449C-80CB-5AD7EFFBCF71",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:sp2:*:*:professional:*:*:*",
              "matchCriteriaId": "06F87184-5F08-4090-BC7A-4C07723C7E56",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:14:*:*:*:professional:*:*:*",
              "matchCriteriaId": "8A60440F-56D2-4D34-AF8D-3F134CE9B916",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:14:-:*:*:professional:*:*:*",
              "matchCriteriaId": "34CB9530-26A9-41F8-AAEA-4C7DCA9B6309",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:14:sp1:*:*:professional:*:*:*",
              "matchCriteriaId": "742222BD-66B1-432A-ABA3-5C3BDE476D6E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:professional:*:*:*",
              "matchCriteriaId": "993FC3FD-2887-4717-91FF-E587FFFD79F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:*:*:*:professional:*:*:*",
              "matchCriteriaId": "44F192C1-B73C-4E00-B643-0FF4D8F62806",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:-:*:*:professional:*:*:*",
              "matchCriteriaId": "43A405ED-4D3B-4B1E-A109-C89299CEBC44",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_2:*:professional:*:*:*",
              "matchCriteriaId": "27ABF4C7-C9DC-4BA7-AFE3-85CF24073706",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp1:update_9:*:professional:*:*:*",
              "matchCriteriaId": "0B2B152A-110E-4113-A736-817D55E6730A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:13:sp2:*:*:professional:*:*:*",
              "matchCriteriaId": "EAFE68A5-0469-45E4-A349-19027F375828",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:-:*:*:professional:*:*:*",
              "matchCriteriaId": "960A60ED-AEB3-4133-A876-A2BAD47C9D14",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:14:sp1:*:*:professional:*:*:*",
              "matchCriteriaId": "A804911F-3924-48A2-BE17-1E4E23403708",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:15:-:*:*:professional:*:*:*",
              "matchCriteriaId": "E150ECFA-B1E8-4462-BCF0-F213EBDD8AB5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:15:update_4:*:*:professional:*:*:*",
              "matchCriteriaId": "0797F07E-BDED-47E1-92DD-E9135157E78D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:15.1:-:*:*:professional:*:*:*",
              "matchCriteriaId": "0D9C7067-7D2D-4D96-9E54-F97ED1DE7A9C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:15.1:update_1:*:*:professional:*:*:*",
              "matchCriteriaId": "96C960B3-424B-46D9-90E2-69A9CD1D4724",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.0 y versiones  anteriores (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones anteriores a la  versi\u00f3n V8.1 con WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (Todas las versiones anteriores a la versi\u00f3n V8.2 SP1 con WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a la versi\u00f3n V9.0 SP2 con WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (Todas las versiones) , SIMATIC WinCC Professional (TIA Portal V14) (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (Todas las versiones anteriores a la versi\u00f3nV15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (Todas las versiones), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versi\u00f3n V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Upd 3), SIMATIC WinCC V7.2 y anteriores (Todas las versiones), SIMATIC WinCC V7.3 (Todas las versiones anteriores a la versi\u00f3n V7.3 Upd 19), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 Upd 3). La aplicaci\u00f3n web SIMATIC WinCC DataMonitor de los productos afectados permite cargar c\u00f3digo ASPX arbitrario. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante autenticado con acceso de red a la aplicaci\u00f3n WinCC DataMonitor. No se requiere interacci\u00f3n del usuario para explotar esta vulnerabilidad. La vulnerabilidad afecta la confidencialidad, integridad y disponibilidad del dispositivo afectado. En la etapa de publicaci\u00f3n de este aviso de seguridad no se conoce explotaci\u00f3n p\u00fablica."
    }
  ],
  "id": "CVE-2019-10935",
  "lastModified": "2024-11-21T04:20:11.120",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-11T22:15:11.797",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-434"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2020-06-10 17:15
Modified
2024-11-21 05:37
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_process_device_manager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "50C02E17-87F5-47DB-B4F3-EFC44B0DFC88",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF09D6E-3375-4731-B16D-30B7592EA5FB",
              "versionEndExcluding": "5.6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:-:*:*:*:*:*:*",
              "matchCriteriaId": "851F8474-4568-487D-98FB-47DF7EAEAC3B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81EADA2F-884C-4D72-8489-71025B3EBAEE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "78366D2F-B728-47F6-B539-5FB2D1B0419D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2_hotfix1:*:*:*:*:*:*",
              "matchCriteriaId": "06A86DA0-BC1F-4306-B02E-ED2FA36BE273",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_starter:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23020179-5112-48A8-BA76-EB6C073867BF",
              "versionEndExcluding": "5.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_starter:5.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "E04348B3-6DAC-49E2-A612-FE0A3166776B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 versi\u00f3n V8.2 y anteriores (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP3), SIMATIC PDM (Todas las versiones anteriores a V9.2), SIMATIC STEP 7 V5.X (Todas las versiones anteriores a V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (Todas las versiones anteriores a V5.4 HF2). Una vulnerabilidad de desbordamiento del b\u00fafer podr\u00eda permitir a un atacante local causar una situaci\u00f3n de Denegaci\u00f3n de Servicio. La vulnerabilidad de seguridad podr\u00eda ser explotada por parte de un atacante con acceso local a los sistemas afectados. Una explotaci\u00f3n con \u00e9xito podr\u00eda requerir privilegios de usuario pero no una interacci\u00f3n del usuario. La vulnerabilidad podr\u00eda permitir a un atacante comprometer la disponibilidad del sistema, as\u00ed como tener acceso a informaci\u00f3n confidencial"
    }
  ],
  "id": "CVE-2020-7586",
  "lastModified": "2024-11-21T05:37:25.427",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-06-10T17:15:12.520",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-122"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-11-09 12:15
Modified
2024-11-21 06:23
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B62697B-2F75-44EA-A1F8-14BF9D1F99CC",
              "versionEndIncluding": "8.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62431198-DA5D-4E7A-A938-162FF374E3FA",
              "versionEndExcluding": "9.1",
              "versionStartIncluding": "9.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D25510C-F677-4A98-806C-FF644F11EEC6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA2E9785-246F-496B-9139-02E2F4003352",
              "versionEndIncluding": "7.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "3422B714-DB0F-4EE3-A7D4-9A0165214563",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*",
              "matchCriteriaId": "70B79B00-F61D-4F10-AD7B-74718F061D9E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*",
              "matchCriteriaId": "A8766442-CC8D-4221-89B8-F75D195F71E8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*",
              "matchCriteriaId": "26C08FB9-AFEB-4A53-AAB3-37C9717B30C5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*",
              "matchCriteriaId": "68896900-7FCC-4BFB-B787-8992B459F00D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:*:*:*:*",
              "matchCriteriaId": "A961C560-0288-4BC7-B3EB-11610765A34A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "A4316924-9EF8-4835-A2E4-0C81F4DE473D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "A1011EBE-A08D-4066-A2B8-45736AE6999B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "37284D6C-ADB9-43A9-817D-7879FDF8BF7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "1DAD73CB-A027-4CEA-A439-A271717BBEDD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*",
              "matchCriteriaId": "150B957C-545F-4BD8-8AB9-E64ACC59C865",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:-:*:*:*:*:*:*",
              "matchCriteriaId": "C665E91E-DC56-41E0-99B4-ACFAA70B3103",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*",
              "matchCriteriaId": "BB46C8BD-942A-45DC-AA8A-C0D9418CA302",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 5). Los sistemas afectados almacenan informaci\u00f3n sensible en archivos de registro. Un atacante con acceso a los archivos de registro podr\u00eda exponer p\u00fablicamente la informaci\u00f3n o reutilizarla para desarrollar otros ataques al sistema"
    }
  ],
  "id": "CVE-2021-40364",
  "lastModified": "2024-11-21T06:23:57.400",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "NONE",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2021-11-09T12:15:10.070",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-532"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-05-14 20:29
Modified
2024-11-21 04:20
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "78F045C4-8DC2-4FA8-833D-B430EA26F2A0",
              "versionEndIncluding": "8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4A75F15-8F47-4348-A85C-D94BBA8F9992",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F27A96F-58B7-492F-8CF7-DE04D4EDAAD8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23B89914-E5BA-4670-B692-092AE9FFE148",
              "versionEndIncluding": "7.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "8D6229A2-9B8E-4F76-8425-589D2CE58B16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3D1A823-CE50-441F-B060-DA678DFE24FD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "28A1BA01-7A92-4368-8A73-8FA47A08BC53",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):15.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "0256663E-3A97-4E99-995D-7446804DB496",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E07DBA91-379C-40F5-8C45-6EC302F5CA7D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.0 y anteriores (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones anteriores a la versi\u00f3n V8.1 con WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (Todas las versiones anteriores a la versi\u00f3n V8.2 SP1 con WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a la versi\u00f3n V9.0 SP2 con WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (Todas las versiones) , SIMATIC WinCC Professional (TIA Portal V14) (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (Todas las versiones anteriores a la versi\u00f3n V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (Todas las versiones), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versi\u00f3n V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Upd 3), SIMATIC WinCC V7.2 y anteriores (Todas las versiones), SIMATIC WinCC V7.3 (Todas las versiones anteriores a la versi\u00f3n V7.3 Upd 19), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 Upd 3). La aplicaci\u00f3n web SIMATIC WinCC DataMonitor de los productos afectados permite cargar c\u00f3digo ASPX arbitrario. La vulnerbilidad de seguridad podr\u00eda ser explotada por un atacante autenticado con acceso de red a la aplicaci\u00f3n WinCC DataMonitor. No se requiere interacci\u00f3n del usuario para explotar esta vulnerabilidad. La vulnerabilidad afecta la confidencialidad, integridad y disponibilidad del dispositivo afectado. En la etapa de publicaci\u00f3n de este aviso de seguridad no se conoce explotaci\u00f3n p\u00fablica."
    }
  ],
  "id": "CVE-2019-10918",
  "lastModified": "2024-11-21T04:20:08.927",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-05-14T20:29:02.483",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-749"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2018-04-24 17:29
Modified
2024-11-21 04:07
Summary
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2CDCCD5-E4C7-4E52-8316-07F93E820842",
              "versionEndIncluding": "7.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F01837-6121-48E3-A18C-691AAC2800BD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "781DC7D3-D470-465E-8E0A-9978CB2A6454",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "726E5A2D-97EA-415A-A251-66A975B3F98C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "ED9B2A87-0C1E-476E-AF7E-71EAB0CECEF0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "20D3788F-FD9E-4A0F-A7C7-843B1ED67D34",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_4:*:*:*:*:*:*",
              "matchCriteriaId": "F8186041-B1D6-4460-ACA7-23494D1F0E7C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:8.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF8FF2D9-B31F-46DC-AF37-E0314F3D0B32",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:openpcs_7:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3890EC18-2B5D-4B5A-8B21-6A0D1211EA98",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:7.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E94E0B9-2950-42CA-837E-7900F820A9F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:8.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "2C782AC7-6EAB-4F35-A646-52A4AC77E1D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:8.0:sp1_upd20:*:*:*:*:*:*",
              "matchCriteriaId": "3C509A97-9DD2-413A-A7ED-B30FD9E5C98F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:8.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "EE12DBC8-CD75-4517-BD3B-709E98B4D280",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:8.1:sp1_upd14:*:*:*:*:*:*",
              "matchCriteriaId": "38894CBB-44DA-4690-B762-4AA497C95037",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:8.1:sp1_upd15:*:*:*:*:*:*",
              "matchCriteriaId": "59178885-4A50-4AC6-A3BE-B288A1F6B5F9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:8.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "4CAFD7F2-BB23-4E3A-A30E-78290D5EAB47",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:8.2:upd_9:*:*:*:*:*:*",
              "matchCriteriaId": "F043FAC3-661C-4226-AA70-7EF836DDBA55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E1EFC3E-F29B-48C5-869C-F356414C8088",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C06726E-497A-4FEF-8B4B-AF3F7B0EEFA4",
              "versionEndExcluding": "15",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*",
              "matchCriteriaId": "7DF90C44-4AC2-4B2B-8712-30CD3DE96B22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4DFBFF6B-DBC8-451D-A235-4C7E1F0883D5",
              "versionEndIncluding": "7.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3566C20F-A4A7-494F-AAD2-A11B0AD783D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "3EEF9BE1-F6E2-4C05-8020-4D7540882464",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20927394-2126-48C5-B0D5-88E16B6491DA",
              "versionEndIncluding": "7.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:8.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "ACF395C1-AA95-4064-BDEF-9B3C30FF6B29",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF693D1E-091C-4CBE-957C-58C47B4E44D4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_route_control:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "57073CE8-174E-429D-A721-AB14C7D16D4F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AAE5EBD-1B43-447D-8C19-9D3296F137F9",
              "versionEndExcluding": "13",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:13:-:*:*:*:*:*:*",
              "matchCriteriaId": "00B0EEF6-E1F9-4AEB-82AA-445D161639D3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:13:sp2_upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "DB8D7040-0223-413F-B87F-3417CFA50BB8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:14:-:*:*:*:*:*:*",
              "matchCriteriaId": "17F622A5-75AE-4E5C-80CB-53C39EAE356D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:14:sp1_upd_4:*:*:*:*:*:*",
              "matchCriteriaId": "8D2F5FA7-6B23-413C-AF6D-CA95EDA59212",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9C72CD2-86C8-4E79-AF98-A3D58E882DED",
              "versionEndExcluding": "7.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "EF42322A-1E6E-44F6-B943-DC56E87F80D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:upd_14:*:*:*:*:*:*",
              "matchCriteriaId": "A54099D6-1E2E-4DC5-98FD-6004758C581A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:-:*:*:*:*:*:*",
              "matchCriteriaId": "AE3690D0-60A7-4E52-A36A-ADBA01F8D99F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:upd_15:*:*:*:*:*:*",
              "matchCriteriaId": "98174EBE-EC43-431C-B943-11B21A167A79",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "9A699260-A239-46BE-BF64-A767D4F267FC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sppa-t3000_application_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5CE233B0-3F20-4FA8-8E26-CCC3E21E49E1",
              "versionEndExcluding": "r8.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "4EBA7673-3A24-4DF7-9D9C-4B863863083C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "D0975E8C-C34F-4BD2-B4CF-41E5FBFD8A12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C06726E-497A-4FEF-8B4B-AF3F7B0EEFA4",
              "versionEndExcluding": "15",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*",
              "matchCriteriaId": "7DF90C44-4AC2-4B2B-8712-30CD3DE96B22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A28DF82-4863-47FA-82FF-C3D63CFB1782",
              "versionEndExcluding": "14.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en OpenPCS 7 V7.1 y anteriores (Todas las versiones), OpenPCS 7 V8.0 (Todas las versiones), OpenPCS 7 V8.1 (Todas las versiones anteriores a V8.1 Upd5), OpenPCS 7 V8. 2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a V9.0 Upd1), SIMATIC BATCH V7.1 y anteriores (Todas las versiones), SIMATIC BATCH V8.0 (Todas las versiones anteriores a V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (Todas las versiones anteriores a V8. 1 SP1 Upd16), SIMATIC BATCH V8.2 (Todas las versiones anteriores a V8.2 Upd10), SIMATIC BATCH V9.0 (Todas las versiones anteriores a V9.0 SP1), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones anteriores a 15 SP1), SIMATIC PCS 7 V7. 1 y anteriores (Todas las versiones), SIMATIC PCS 7 V8.0 (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones), SIMATIC PCS 7 V8. 2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP1), SIMATIC Route Control V7.1 y anteriores (Todas las versiones), SIMATIC Route Control V8.0 (Todas las versiones), SIMATIC Route Control V8.1 (Todas las versiones), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones anteriores a V9. 0 Upd1), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a V14 SP1 Upd5), SIMATIC WinCC V7.2 y anteriores (Todas las versiones anteriores a WinCC 7. 2 Upd 15), SIMATIC WinCC V7.3 (Todas las versiones anteriores a WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Upd 4), SPPA-T3000 Application Server (Todas las versiones anteriores a Service Pack R8.2 SP2). Los mensajes especialmente dise\u00f1ados enviados al servicio RPC de los productos afectados podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio en la funcionalidad de comunicaci\u00f3n remota y local de los productos afectados. Es necesario reiniciar el sistema para recuperar la funcionalidad de comunicaci\u00f3n remota y local. Tenga en cuenta que un atacante necesita tener acceso a la red del servidor de aplicaciones para poder explotar esta vulnerabilidad. En el momento de la publicaci\u00f3n del aviso no se conoc\u00eda ninguna explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad"
    }
  ],
  "id": "CVE-2018-4832",
  "lastModified": "2024-11-21T04:07:32.557",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2018-04-24T17:29:00.227",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-09 16:15
Modified
2024-11-21 06:23
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B62697B-2F75-44EA-A1F8-14BF9D1F99CC",
              "versionEndIncluding": "8.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D25510C-F677-4A98-806C-FF644F11EEC6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F39B396-140B-4005-9A61-F984C9FAF742",
              "versionEndExcluding": "7.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*",
              "matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*",
              "matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*",
              "matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*",
              "matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update14:*:*:*:*:*:*",
              "matchCriteriaId": "3C5F5AD3-878D-42B0-B30E-8B0B6174486B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update15:*:*:*:*:*:*",
              "matchCriteriaId": "57F59EE1-46FC-4B94-AB30-F1D3235C5A1D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update16:*:*:*:*:*:*",
              "matchCriteriaId": "BA774F51-885C-4579-982E-431A8AB027B7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update17:*:*:*:*:*:*",
              "matchCriteriaId": "110DF98C-BE75-43B6-B63D-1D7D99AFFA73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update18:*:*:*:*:*:*",
              "matchCriteriaId": "11F812DE-BF33-4CB0-8E21-81682E3B88CA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*",
              "matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*",
              "matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*",
              "matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*",
              "matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*",
              "matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*",
              "matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*",
              "matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "D0A0534C-8EDE-46FF-82A0-812CF069ABC9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "3422B714-DB0F-4EE3-A7D4-9A0165214563",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*",
              "matchCriteriaId": "70B79B00-F61D-4F10-AD7B-74718F061D9E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*",
              "matchCriteriaId": "A8766442-CC8D-4221-89B8-F75D195F71E8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*",
              "matchCriteriaId": "26C08FB9-AFEB-4A53-AAB3-37C9717B30C5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*",
              "matchCriteriaId": "68896900-7FCC-4BFB-B787-8992B459F00D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update5:*:*:*:*:*:*",
              "matchCriteriaId": "1059B529-02F0-4C85-A35E-2282546FA990",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:*:*:*:*",
              "matchCriteriaId": "0D9FE447-2090-47D2-8667-5DC7605089BB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BB4FFADC-51F0-439F-9F80-D2B2614FFC39",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "4C117FFB-A3FF-4E82-9CE9-B2DFFAF7D799",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:14.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE5A7162-F1B5-4E74-99D6-4108AC4C49FC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15:*:*:*:*:*:*:*",
              "matchCriteriaId": "A961C560-0288-4BC7-B3EB-11610765A34A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "50B77C2A-4D66-4407-8CA4-99C43ED72DDB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:*",
              "matchCriteriaId": "9794ED7E-EB17-4C95-B900-840A48758F03",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:*",
              "matchCriteriaId": "57E82CFE-4191-4055-A0BA-EAB7BE96D947",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:*",
              "matchCriteriaId": "C4DBBDAA-BCAE-4B63-BDFC-3DD70DAD9B7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:*",
              "matchCriteriaId": "B5AF87C6-F8D6-4462-9DF5-B9D301002B1C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_5:*:*:*:*:*:*",
              "matchCriteriaId": "E4D610DA-D1EF-487E-94CB-FC6E6BE4BE4C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_6:*:*:*:*:*:*",
              "matchCriteriaId": "6BB49DC6-B8AB-4320-B5CB-8EB803D41194",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "A4316924-9EF8-4835-A2E4-0C81F4DE473D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "A1011EBE-A08D-4066-A2B8-45736AE6999B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "37284D6C-ADB9-43A9-817D-7879FDF8BF7F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "1DAD73CB-A027-4CEA-A439-A271717BBEDD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:update4:*:*:*:*:*:*",
              "matchCriteriaId": "150B957C-545F-4BD8-8AB9-E64ACC59C865",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:-:*:*:*:*:*:*",
              "matchCriteriaId": "C665E91E-DC56-41E0-99B4-ACFAA70B3103",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:17:update1:*:*:*:*:*:*",
              "matchCriteriaId": "BB46C8BD-942A-45DC-AA8A-C0D9418CA302",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores a V9. 1 SP1), SIMATIC WinCC V15 y anteriores (Todas las versiones anteriores a V15 SP1 Update 7), SIMATIC WinCC V16 (Todas las versiones anteriores a V16 Update 5), SIMATIC WinCC V17 (Todas las versiones anteriores a V17 Update 2), SIMATIC WinCC V17 (Todas las versiones anteriores a= V17 Update 4), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP2 Update 6). El componente afectado almacena las credenciales de una cuenta del sistema local en un archivo de proyecto potencialmente accesible al p\u00fablico utilizando un algoritmo de cifrado obsoleto. Un atacante puede usar esto para forzar las credenciales y tomar el control del sistema"
    }
  ],
  "id": "CVE-2021-40363",
  "lastModified": "2024-11-21T06:23:57.250",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-02-09T16:15:13.877",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-538"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-312"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2014-11-26 11:59
Modified
2024-11-21 02:19
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "33FA164B-E269-4140-AC85-2623356AF636",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "D62C7959-87D9-42EC-A224-2EE6EF23C1CF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "428F68D2-8C1D-4ADE-A6FB-65EC4C426F99",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "14193511-1B9B-4319-92AE-BB26F398550C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "19C3A00B-A47E-4723-B652-B64FDC5F2601",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*",
              "matchCriteriaId": "144DE778-4439-489F-830D-B4742BB11FEB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*",
              "matchCriteriaId": "39B75B5E-7979-4E3B-BE94-AE04F17A6F3C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "E8274939-833E-40E1-8D2E-1B28CEA91036",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "61F46206-F232-4F62-AF4F-E2DCF462AE60",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*",
              "matchCriteriaId": "2D6E154F-F8A0-4E9D-BC37-E95B1820D2BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*",
              "matchCriteriaId": "D6745F96-FA72-457B-AD14-07C4B353310F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*",
              "matchCriteriaId": "E555D458-59C4-4CBC-95F4-CBA503BCCB24",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*",
              "matchCriteriaId": "3BEE67FC-D188-4B0C-A837-FC91B406982E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*",
              "matchCriteriaId": "75121F46-303D-4416-8FBD-1938BDD60AAB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*",
              "matchCriteriaId": "FF8B251F-399E-4165-B3A6-801775212C5D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*",
              "matchCriteriaId": "FBE45DD1-630F-448F-90FE-D3CC00266EF1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:8:*:*:*:*:*:*",
              "matchCriteriaId": "CFC7DC1F-B4C5-4116-9B53-706F2B3227DD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:1:*:*:*:*:*:*",
              "matchCriteriaId": "B8F27E75-90CD-4C3B-AF0E-90EF338A2D91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets."
    },
    {
      "lang": "es",
      "value": "El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualizaci\u00f3n 9, y 7.3 anterior a la actualizaci\u00f3n 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2, y 8.1; y TIA Portal 13 anterior a la actualizaci\u00f3n 6 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de paquetes manipulados."
    }
  ],
  "id": "CVE-2014-8551",
  "lastModified": "2024-11-21T02:19:19.247",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2014-11-26T11:59:00.093",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-94"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2014-11-26 11:59
Modified
2024-11-21 02:19
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:7.1:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BE258BF2-AD82-401C-B020-08A22A549A25",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "33FA164B-E269-4140-AC85-2623356AF636",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:7.1:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "D62C7959-87D9-42EC-A224-2EE6EF23C1CF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "428F68D2-8C1D-4ADE-A6FB-65EC4C426F99",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "14193511-1B9B-4319-92AE-BB26F398550C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs7:8.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "172A6A81-C32E-4ACC-AB8C-2014BF3A6901",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "19C3A00B-A47E-4723-B652-B64FDC5F2601",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:3:*:*:*:*:*:*",
              "matchCriteriaId": "144DE778-4439-489F-830D-B4742BB11FEB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_tiaportal:13.0:5:*:*:*:*:*:*",
              "matchCriteriaId": "39B75B5E-7979-4E3B-BE94-AE04F17A6F3C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CF84FC5-9450-47B7-A4F0-99361C528C00",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "E8274939-833E-40E1-8D2E-1B28CEA91036",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "61F46206-F232-4F62-AF4F-E2DCF462AE60",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.0:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "0D0BB2E6-1444-499A-943E-8D19C402F1BD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:1:*:*:*:*:*:*",
              "matchCriteriaId": "2D6E154F-F8A0-4E9D-BC37-E95B1820D2BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:2:*:*:*:*:*:*",
              "matchCriteriaId": "D6745F96-FA72-457B-AD14-07C4B353310F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:3:*:*:*:*:*:*",
              "matchCriteriaId": "E555D458-59C4-4CBC-95F4-CBA503BCCB24",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:4:*:*:*:*:*:*",
              "matchCriteriaId": "3BEE67FC-D188-4B0C-A837-FC91B406982E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:5:*:*:*:*:*:*",
              "matchCriteriaId": "75121F46-303D-4416-8FBD-1938BDD60AAB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:6:*:*:*:*:*:*",
              "matchCriteriaId": "FF8B251F-399E-4165-B3A6-801775212C5D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:7:*:*:*:*:*:*",
              "matchCriteriaId": "FBE45DD1-630F-448F-90FE-D3CC00266EF1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:8:*:*:*:*:*:*",
              "matchCriteriaId": "CFC7DC1F-B4C5-4116-9B53-706F2B3227DD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:1:*:*:*:*:*:*",
              "matchCriteriaId": "B8F27E75-90CD-4C3B-AF0E-90EF338A2D91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets."
    },
    {
      "lang": "es",
      "value": "El servidor WinCC en Siemens SIMATIC WinCC 7.0 hasta SP3, 7.2 anterior a la actualizaci\u00f3n 9, y 7.3 anterior a la actualizaci\u00f3n 2; SIMATIC PCS 7 7.1 hasta SP4, 8.0 hasta SP2; y 8.1; y TIA Portal 13 anterior a la actualizaci\u00f3n 6 permite a atacantes remotos leer ficheros arbitrarios a trav\u00e9s de paquetes manipulados."
    }
  ],
  "id": "CVE-2014-8552",
  "lastModified": "2024-11-21T02:19:19.387",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2014-11-26T11:59:01.373",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2016-7165
Vulnerability from cvelistv5
Published
2016-11-15 19:00
Modified
2024-08-06 01:50
Severity ?
Summary
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:50:47.526Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
          },
          {
            "name": "94158",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/94158"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2016-11-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-14T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
        },
        {
          "name": "94158",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/94158"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2016-7165",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Primary Setup Tool (PST) (All versions \u003c V4.2 HF1), SIMATIC IT Production Suite (All versions \u003c V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions \u003c V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions \u003c V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions \u003c V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions \u003c V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions \u003c V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1), SIMIT V9.0 (All versions \u003c V9.0 SP1), SINEMA Remote Connect Client (All versions \u003c V1.0 SP3), SINEMA Server (All versions \u003c V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions \u003c V4.3 HF1), TeleControl Server Basic (All versions \u003c V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path (\"C:\\Program Files\\*\" or the localized equivalent)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02"
            },
            {
              "name": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html",
              "refsource": "MISC",
              "url": "http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html"
            },
            {
              "name": "94158",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/94158"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-7165",
    "datePublished": "2016-11-15T19:00:00",
    "dateReserved": "2016-09-08T00:00:00",
    "dateUpdated": "2024-08-06T01:50:47.526Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-7580
Vulnerability from cvelistv5
Published
2020-06-10 00:00
Modified
2024-08-04 09:33
Severity ?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Impacted products
Vendor Product Version
Siemens SIMATIC NET PC Software V14 Version: All versions < V14 SP1 Update 14
Siemens SIMATIC NET PC Software V15 Version: All versions
Siemens SIMATIC NET PC Software V16 Version: All versions < V16 Upd3
Siemens SIMATIC PCS neo Version: All versions < V3.0 SP1
Siemens SIMATIC ProSave Version: All versions < V17
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V21.8
Siemens SIMATIC STEP 7 (TIA Portal) V13 Version: All versions < V13 SP2 Update 4
Siemens SIMATIC STEP 7 (TIA Portal) V14 Version: All versions < V14 SP1 Update 10
Siemens SIMATIC STEP 7 (TIA Portal) V15 Version: All versions < V15.1 Update 5
Siemens SIMATIC STEP 7 (TIA Portal) V16 Version: All versions < V16 Update 2
Siemens SIMATIC STEP 7 V5 Version: All versions < V5.6 SP2 HF3
Siemens SIMATIC WinCC OA V3.16 Version: All versions < V3.16 P018
Siemens SIMATIC WinCC OA V3.17 Version: All versions < V3.17 P003
Siemens SIMATIC WinCC Runtime Advanced Version: All versions < V16 Update 2
Siemens SIMATIC WinCC Runtime Professional V13 Version: All versions < V13 SP2 Update 4
Siemens SIMATIC WinCC Runtime Professional V14 Version: All versions < V14 SP1 Update 10
Siemens SIMATIC WinCC Runtime Professional V15 Version: All versions < V15.1 Update 5
Siemens SIMATIC WinCC Runtime Professional V16 Version: All versions < V16 Update 2
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 14
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP1 Update 3
Siemens SINAMICS STARTER Version: All Versions < V5.4 HF2
Siemens SINAMICS Startdrive Version: All Versions < V16 Update 3
Siemens SINEC NMS Version: All versions < V1.0 SP2
Siemens SINEMA Server Version: All versions < V14 SP3
Siemens SINUMERIK ONE virtual Version: All Versions < V6.14
Siemens SINUMERIK Operate Version: All Versions < V6.14
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.492Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Upd3"
            }
          ]
        },
        {
          "product": "SIMATIC PCS neo",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC ProSave",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.8"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.16 P018"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.17 P003"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP1 Update 3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.4 HF2"
            }
          ]
        },
        {
          "product": "SINAMICS Startdrive",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V16 Update 3"
            }
          ]
        },
        {
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0 SP2"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP3"
            }
          ]
        },
        {
          "product": "SINUMERIK ONE virtual",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        },
        {
          "product": "SINUMERIK Operate",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428: Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-7580",
    "datePublished": "2020-06-10T00:00:00",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2010-2772
Vulnerability from cvelistv5
Published
2010-07-22 10:00
Modified
2024-08-07 02:46
Severity ?
Summary
Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T02:46:48.161Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "simatic-wincc-default-password(60587)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.f-secure.com/weblog/archives/00001987.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1"
          },
          {
            "name": "ADV-2010-1893",
            "tags": [
              "vdb-entry",
              "x_refsource_VUPEN",
              "x_transferred"
            ],
            "url": "http://www.vupen.com/english/advisories/2010/1893"
          },
          {
            "name": "40682",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/40682"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"
          },
          {
            "name": "41753",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/41753"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2010-07-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-16T14:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "simatic-wincc-default-password(60587)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.f-secure.com/weblog/archives/00001987.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1"
        },
        {
          "name": "ADV-2010-1893",
          "tags": [
            "vdb-entry",
            "x_refsource_VUPEN"
          ],
          "url": "http://www.vupen.com/english/advisories/2010/1893"
        },
        {
          "name": "40682",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/40682"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"
        },
        {
          "name": "41753",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/41753"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2010-2772",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "simatic-wincc-default-password(60587)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/60587"
            },
            {
              "name": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr",
              "refsource": "MISC",
              "url": "http://infoworld.com/d/security-central/siemens-warns-users-dont-change-passwords-after-worm-attack-915?sourcefssr"
            },
            {
              "name": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c",
              "refsource": "CONFIRM",
              "url": "http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026caller=viewhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=43876783\u0026c"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-12-205-01"
            },
            {
              "name": "http://www.f-secure.com/weblog/archives/00001987.html",
              "refsource": "MISC",
              "url": "http://www.f-secure.com/weblog/archives/00001987.html"
            },
            {
              "name": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1",
              "refsource": "MISC",
              "url": "http://www.automation.siemens.com/forum/guests/PostShow.aspx?PostID=16127\u002616127\u0026Language=en\u0026PageIndex=1"
            },
            {
              "name": "ADV-2010-1893",
              "refsource": "VUPEN",
              "url": "http://www.vupen.com/english/advisories/2010/1893"
            },
            {
              "name": "40682",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/40682"
            },
            {
              "name": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/",
              "refsource": "MISC",
              "url": "http://krebsonsecurity.com/2010/07/experts-warn-of-new-windows-shortcut-flaw/"
            },
            {
              "name": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx",
              "refsource": "CONFIRM",
              "url": "http://www.sea.siemens.com/us/News/Industrial/Pages/WinCC_Update.aspx"
            },
            {
              "name": "41753",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/41753"
            },
            {
              "name": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725",
              "refsource": "MISC",
              "url": "http://infoworld.com/d/security-central/new-weaponized-virus-targets-industrial-secrets-725"
            },
            {
              "name": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22",
              "refsource": "MISC",
              "url": "http://www.wilderssecurity.com/showpost.php?p=1712134\u0026postcount=22"
            },
            {
              "name": "http://www.wired.com/threatlevel/2010/07/siemens-scada/",
              "refsource": "MISC",
              "url": "http://www.wired.com/threatlevel/2010/07/siemens-scada/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2010-2772",
    "datePublished": "2010-07-22T10:00:00",
    "dateReserved": "2010-07-21T00:00:00",
    "dateUpdated": "2024-08-07T02:46:48.161Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10918
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Vendor Product Version
Siemens AG SIMATIC PCS 7 V8.1 Version: All versions < V8.1 with WinCC V7.3 Upd 19
Siemens AG SIMATIC PCS 7 V8.2 Version: All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11
Siemens AG SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11
Siemens AG SIMATIC WinCC (TIA Portal) V13 Version: All versions
Siemens AG SIMATIC WinCC (TIA Portal) V14 Version: All versions < V14 SP1 Upd 9
Siemens AG SIMATIC WinCC (TIA Portal) V15 Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC Runtime Professional V13 Version: All versions
Siemens AG SIMATIC WinCC Runtime Professional V14 Version: All versions < V14.1 Upd 8
Siemens AG SIMATIC WinCC Runtime Professional V15 Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC V7.2 and earlier Version: All versions
Siemens AG SIMATIC WinCC V7.3 Version: All versions < V7.3 Upd 19
Siemens AG SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Upd 11
Siemens AG SIMATIC WinCC V7.5 Version: All versions < V7.5 Upd 3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.144Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-749",
              "description": "CWE-749: Exposed Dangerous Method or Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:28:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10918",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-749: Exposed Dangerous Method or Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10918",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.144Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-7586
Vulnerability from cvelistv5
Published
2020-06-10 16:23
Modified
2024-08-04 09:33
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP3
Siemens SIMATIC PDM Version: All versions < V9.2
Siemens SIMATIC STEP 7 V5.X Version: All versions < V5.6 SP2 HF3
Siemens SINAMICS STARTER (containing STEP 7 OEM version) Version: All versions < V5.4 HF2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.798Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3"
            }
          ]
        },
        {
          "product": "SIMATIC PDM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER (containing STEP 7 OEM version)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4 HF2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T20:42:20",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-7586",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PDM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.6 SP2 HF3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.4 HF2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A buffer overflow vulnerability could allow a local attacker to cause a Denial-of-Service situation. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-122: Heap-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05",
              "refsource": "CONFIRM",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-7586",
    "datePublished": "2020-06-10T16:23:52",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.798Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-25910
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2024-08-02 11:32
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server. An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server.
Impacted products
Vendor Product Version
Siemens SIMATIC S7-PM Version: 0   < V5.7 SP1 HF1
Siemens SIMATIC S7-PM Version: 0   < V5.7 SP2 HF1
Siemens SIMATIC STEP 7 V5 Version: 0   < V5.7
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T11:32:12.730Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 UC04",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7 SP1 HF1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PM",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7 SP2 HF1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 V5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions \u003c V9.1 SP2 UC04), SIMATIC S7-PM (All versions \u003c V5.7 SP1 HF1), SIMATIC S7-PM (All versions \u003c V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions \u003c V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.\r\n\r\nAn attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system\u0027s server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:T/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-15T07:23:34.211Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-968170.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-25910",
    "datePublished": "2023-06-13T08:17:04.612Z",
    "dateReserved": "2023-02-16T11:12:33.500Z",
    "dateUpdated": "2024-08-02T11:32:12.730Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-10048
Vulnerability from cvelistv5
Published
2021-02-09 15:38
Modified
2024-08-04 10:50
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication.
Impacted products
Vendor Product Version
Siemens SIMATIC WinCC Version: All versions < V7.5 SP2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:50:57.903Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-288",
              "description": "CWE-288: Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-09T15:38:17",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-10048",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 SP2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-288: Authentication Bypass Using an Alternate Path or Channel"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-10048",
    "datePublished": "2021-02-09T15:38:17",
    "dateReserved": "2020-03-04T00:00:00",
    "dateUpdated": "2024-08-04T10:50:57.903Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-31894
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-08-03 23:10
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.X Version: All versions < V9.1 SP2
Siemens SIMATIC PDM Version: All versions < V9.2 SP2
Siemens SIMATIC STEP 7 V5.X Version: All versions < V5.7
Siemens SINAMICS STARTER (containing STEP 7 OEM version) Version: All versions < V5.4 SP2 HF1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:10:30.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC PDM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.2 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.7"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER (containing STEP 7 OEM version)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c  V5.4 SP2 HF1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions \u003c V9.1 SP2), SIMATIC PDM (All versions \u003c V9.2 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 SP2 HF1). A directory containing metafiles relevant to devices\u0027 configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-732",
              "description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:17:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-31894",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.1 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PDM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.2 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c  V5.4 SP2 HF1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions \u003c V9.1 SP2), SIMATIC PDM (All versions \u003c V9.2 SP2), SIMATIC STEP 7 V5.X (All versions \u003c V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 SP2 HF1). A directory containing metafiles relevant to devices\u0027 configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-661034.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-31894",
    "datePublished": "2021-07-13T11:02:58",
    "dateReserved": "2021-04-29T00:00:00",
    "dateUpdated": "2024-08-03T23:10:30.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2016-9160
Vulnerability from cvelistv5
Published
2016-12-17 03:34
Modified
2024-08-06 02:42
Severity ?
Summary
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T02:42:11.100Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf"
          },
          {
            "name": "1037435",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1037435"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04"
          },
          {
            "name": "94825",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/94825"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1)"
            }
          ]
        }
      ],
      "datePublic": "2016-12-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-111",
              "description": "CWE-111: Direct Use of Unsafe JNI",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-26T09:57:01",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf"
        },
        {
          "name": "1037435",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1037435"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04"
        },
        {
          "name": "94825",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/94825"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2016-9160",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in SIEMENS SIMATIC WinCC (All versions \u003c SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions \u003c SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-111: Direct Use of Unsafe JNI"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf"
            },
            {
              "name": "1037435",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1037435"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04"
            },
            {
              "name": "94825",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/94825"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2016-9160",
    "datePublished": "2016-12-17T03:34:00",
    "dateReserved": "2016-11-03T00:00:00",
    "dateUpdated": "2024-08-06T02:42:11.100Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10917
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Vendor Product Version
Siemens AG SIMATIC PCS 7 V8.1 Version: All versions < V8.1 with WinCC V7.3 Upd 19
Siemens AG SIMATIC PCS 7 V8.2 Version: All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11
Siemens AG SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11
Siemens AG SIMATIC WinCC (TIA Portal) V13 Version: All versions
Siemens AG SIMATIC WinCC (TIA Portal) V14 Version: All versions < V14 SP1 Upd 9
Siemens AG SIMATIC WinCC (TIA Portal) V15 Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC Runtime Professional V13 Version: All versions
Siemens AG SIMATIC WinCC Runtime Professional V14 Version: All versions < V14.1 Upd 8
Siemens AG SIMATIC WinCC Runtime Professional V15 Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC V7.2 and earlier Version: All versions
Siemens AG SIMATIC WinCC V7.3 Version: All versions < V7.3 Upd 19
Siemens AG SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Upd 11
Siemens AG SIMATIC WinCC V7.5 Version: All versions < V7.5 Upd 3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:28:02",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10917",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10917",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.224Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2014-8552
Vulnerability from cvelistv5
Published
2014-11-26 11:00
Modified
2024-08-06 13:18
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.641Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-11-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-11-26T06:57:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8552",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to read arbitrary files via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8552",
    "datePublished": "2014-11-26T11:00:00",
    "dateReserved": "2014-10-30T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.641Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-40358
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 02:44
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP3 UC04
Siemens SIMATIC PCS 7 V9.1 Version: All versions < V9.1 SP1
Siemens SIMATIC WinCC V15 and earlier Version: All versions < V15 SP1 Update 7
Siemens SIMATIC WinCC V16 Version: All versions < V16 Update 5
Siemens SIMATIC WinCC V17 Version: All versions < V17 Update 2
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 19
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP2 Update 5
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:09.554Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3 UC04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V15 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15 SP1 Update 7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP2 Update 5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:58.251Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-40358",
    "datePublished": "2021-11-09T11:32:04",
    "dateReserved": "2021-09-01T00:00:00",
    "dateUpdated": "2024-08-04T02:44:09.554Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-40360
Vulnerability from cvelistv5
Published
2022-02-09 15:17
Modified
2024-08-04 02:44
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.0 Version: All versions
Siemens SIMATIC PCS 7 V9.1 Version: All versions < V9.1 SP1
Siemens SIMATIC WinCC V15 and earlier Version: All versions < V15 SP1 Update 7
Siemens SIMATIC WinCC V16 Version: All versions < V16 Update 5
Siemens SIMATIC WinCC V17 Version: All versions < V17 Update 2
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 19
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP2 Update 6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:09.157Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V15 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15 SP1 Update 7"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP2 Update 6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-10T09:46:42",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-40360",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.1 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V15 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15 SP1 Update 7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V16",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16 Update 5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V17",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V17 Update 2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Update 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 SP2 Update 6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-40360",
    "datePublished": "2022-02-09T15:17:03",
    "dateReserved": "2021-09-01T00:00:00",
    "dateUpdated": "2024-08-04T02:44:09.157Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-28829
Vulnerability from cvelistv5
Published
2023-06-13 08:17
Modified
2025-01-03 01:52
Summary
A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions < V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms & Events)) were used per default. These services were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents.
Impacted products
Vendor Product Version
Siemens SIMATIC NET PC Software V15 Version: All versions
Siemens SIMATIC PCS 7 V8.2 Version: All versions
Siemens SIMATIC PCS 7 V9.0 Version: All versions
Siemens SIMATIC PCS 7 V9.1 Version: All versions
Siemens SIMATIC WinCC Version: All versions < V8.0
Siemens SINAUT Software ST7sc Version: All versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:51:38.624Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28829",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-03T01:45:58.400145Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-03T01:52:55.603Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAUT Software ST7sc",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC WinCC (All versions \u003c V8.0), SINAUT Software ST7sc (All versions). Before SIMATIC WinCC V8, legacy OPC services (OPC DA (Data Access), OPC HDA (Historical Data Access), and OPC AE (Alarms \u0026 Events)) were used per default. These\r\nservices were designed on top of the Windows ActiveX and DCOM mechanisms and do not implement state-of-the-art security mechanisms for authentication and encryption of contents."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.9,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-477",
              "description": "CWE-477: Use of Obsolete Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-06-13T08:17:07.989Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-508677.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-28829",
    "datePublished": "2023-06-13T08:17:07.989Z",
    "dateReserved": "2023-03-24T15:17:29.558Z",
    "dateUpdated": "2025-01-03T01:52:55.603Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-24287
Vulnerability from cvelistv5
Published
2022-05-10 09:46
Modified
2024-08-03 04:07
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP3 UC06
Siemens SIMATIC PCS 7 V9.1 Version: All versions < V9.1 SP1 UC01
Siemens SIMATIC WinCC Runtime Professional V16 and earlier Version: All versions
Siemens SIMATIC WinCC Runtime Professional V17 Version: All versions < V17 Upd4
Siemens SIMATIC WinCC V7.3 Version: All versions
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 21
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP2 Update 8
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:07:02.492Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3 UC06"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP1 UC01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V16 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 21"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP2 Update 8"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188: Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-11-14T11:03:11.010Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-24287",
    "datePublished": "2022-05-10T09:46:57",
    "dateReserved": "2022-02-01T00:00:00",
    "dateUpdated": "2024-08-03T04:07:02.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2016-5743
Vulnerability from cvelistv5
Published
2016-07-22 15:00
Modified
2024-08-06 01:08
Severity ?
Summary
Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T01:08:00.812Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1036441",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1036441"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-208-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
          },
          {
            "name": "92112",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/92112"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2016-07-22T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2016-11-25T20:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "1036441",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1036441"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-208-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
        },
        {
          "name": "92112",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/92112"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2016-5743",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1 as distributed in SIMATIC PCS 7 8.2, and SIMATIC WinCC Runtime Professional before 13 SP1 Update 9 allow remote attackers to execute arbitrary code via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1036441",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1036441"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-208-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-208-01"
            },
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf"
            },
            {
              "name": "92112",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/92112"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-5743",
    "datePublished": "2016-07-22T15:00:00",
    "dateReserved": "2016-06-22T00:00:00",
    "dateUpdated": "2024-08-06T01:08:00.812Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10922
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Vendor Product Version
Siemens AG SIMATIC PCS 7 V8.1 and newer Version: All versions
Siemens AG SIMATIC WinCC V7.2 and earlier Version: All versions
Siemens AG SIMATIC WinCC V7.3 and newer Version: All versions
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.230Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
          },
          {
            "name": "108398",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108398"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1 and newer",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3 and newer",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without \"Encrypted Communication\", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-21T17:06:03",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
        },
        {
          "name": "108398",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108398"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10922",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1 and newer",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3 and newer",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without \"Encrypted Communication\", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
            },
            {
              "name": "108398",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108398"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10922",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.230Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2018-4832
Vulnerability from cvelistv5
Published
2018-04-24 17:00
Modified
2024-08-05 05:18
Severity ?
Summary
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Vendor Product Version
Siemens OpenPCS 7 V8.0 Version: All versions
Siemens OpenPCS 7 V8.1 Version: All versions < V8.1 Upd5
Siemens OpenPCS 7 V8.2 Version: All versions
Siemens OpenPCS 7 V9.0 Version: All versions < V9.0 Upd1
Siemens SIMATIC BATCH V7.1 and earlier Version: All versions
Siemens SIMATIC BATCH V8.0 Version: All versions < V8.0 SP1 Upd21
Siemens SIMATIC BATCH V8.1 Version: All versions < V8.1 SP1 Upd16
Siemens SIMATIC BATCH V8.2 Version: All versions < V8.2 Upd10
Siemens SIMATIC BATCH V9.0 Version: All versions < V9.0 SP1
Siemens SIMATIC NET PC Software V14 Version: All versions < V14 SP1 Update 14
Siemens SIMATIC NET PC Software V15 Version: All versions < 15 SP1
Siemens SIMATIC PCS 7 V7.1 and earlier Version: All versions
Siemens SIMATIC PCS 7 V8.0 Version: All versions
Siemens SIMATIC PCS 7 V8.1 Version: All versions
Siemens SIMATIC PCS 7 V8.2 Version: All versions < V8.2 SP1
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP1
Siemens SIMATIC Route Control V7.1 and earlier Version: All versions
Siemens SIMATIC Route Control V8.0 Version: All versions
Siemens SIMATIC Route Control V8.1 Version: All versions
Siemens SIMATIC Route Control V8.2 Version: All versions
Siemens SIMATIC Route Control V9.0 Version: All versions < V9.0 Upd1
Siemens SIMATIC WinCC Runtime Professional V13 Version: All versions < V13 SP2 Upd2
Siemens SIMATIC WinCC Runtime Professional V14 Version: All versions < V14 SP1 Upd5
Siemens SIMATIC WinCC V7.2 and earlier Version: All versions < WinCC 7.2 Upd 15
Siemens SIMATIC WinCC V7.3 Version: All versions < WinCC 7.3 Upd 16
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Upd 4
Siemens SPPA-T3000 Application Server Version: All versions < Service Pack R8.2 SP2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.633Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OpenPCS 7 V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 Upd5"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "OpenPCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 Upd1"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.0 SP1 Upd21"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 SP1 Upd16"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 Upd10"
            }
          ]
        },
        {
          "product": "SIMATIC BATCH V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 15 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V7.1 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC Route Control V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 Upd1"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Upd2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c WinCC 7.2 Upd 15"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c WinCC 7.3 Upd 16"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 4"
            }
          ]
        },
        {
          "product": "SPPA-T3000 Application Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c Service Pack R8.2 SP2"
            }
          ]
        }
      ],
      "datePublic": "2018-03-27T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:06:48",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-4832",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OpenPCS 7 V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 Upd5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "OpenPCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 Upd1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.0 SP1 Upd21"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 SP1 Upd16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 Upd10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC BATCH V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Update 14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c 15 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V7.1 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V8.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC Route Control V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 Upd1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V13 SP2 Upd2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c WinCC 7.2 Upd 15"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c WinCC 7.3 Upd 16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SPPA-T3000 Application Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c Service Pack R8.2 SP2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20: Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf"
            },
            {
              "name": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4832",
    "datePublished": "2018-04-24T17:00:00",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-08-05T05:18:26.633Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2014-8551
Vulnerability from cvelistv5
Published
2014-11-26 11:00
Modified
2024-08-06 13:18
Severity ?
Summary
The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.431Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-11-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-11-26T06:57:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8551",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The WinCC server in Siemens SIMATIC WinCC 7.0 through SP3, 7.2 before Update 9, and 7.3 before Update 2; SIMATIC PCS 7 7.1 through SP4, 8.0 through SP2, and 8.1; and TIA Portal 13 before Update 6 allows remote attackers to execute arbitrary code via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-134508.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8551",
    "datePublished": "2014-11-26T11:00:00",
    "dateReserved": "2014-10-30T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.431Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-7585
Vulnerability from cvelistv5
Published
2020-06-10 16:23
Modified
2024-08-04 09:33
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC PDM (All versions < V9.2), SIMATIC STEP 7 V5.X (All versions < V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP3
Siemens SIMATIC PDM Version: All versions < V9.2
Siemens SIMATIC STEP 7 V5.X Version: All versions < V5.6 SP2 HF3
Siemens SINAMICS STARTER (containing STEP 7 OEM version) Version: All versions < V5.4 HF2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.945Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3"
            }
          ]
        },
        {
          "product": "SIMATIC PDM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER (containing STEP 7 OEM version)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4 HF2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427: Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T20:42:20",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-7585",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PDM",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 V5.X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.6 SP2 HF3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINAMICS STARTER (containing STEP 7 OEM version)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.4 HF2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC PDM (All versions \u003c V9.2), SIMATIC STEP 7 V5.X (All versions \u003c V5.6 SP2 HF3), SINAMICS STARTER (containing STEP 7 OEM version) (All versions \u003c V5.4 HF2). A DLL Hijacking vulnerability could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise the availability of the system as well as to have access to confidential information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-427: Uncontrolled Search Path Element"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-05"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05",
              "refsource": "CONFIRM",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-05"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-7585",
    "datePublished": "2020-06-10T16:23:39",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.945Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10916
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Impacted products
Vendor Product Version
Siemens AG SIMATIC PCS 7 V8.1 Version: All versions < V8.1 with WinCC V7.3 Upd 19
Siemens AG SIMATIC PCS 7 V8.2 Version: All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11
Siemens AG SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11
Siemens AG SIMATIC WinCC (TIA Portal) V13 Version: All versions
Siemens AG SIMATIC WinCC (TIA Portal) V14 Version: All versions < V14 SP1 Upd 9
Siemens AG SIMATIC WinCC (TIA Portal) V15 Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC Runtime Professional V13 Version: All versions
Siemens AG SIMATIC WinCC Runtime Professional V14 Version: All versions < V14.1 Upd 8
Siemens AG SIMATIC WinCC Runtime Professional V15 Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC V7.2 and earlier Version: All versions
Siemens AG SIMATIC WinCC V7.3 Version: All versions < V7.3 Upd 19
Siemens AG SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Upd 11
Siemens AG SIMATIC WinCC V7.5 Version: All versions < V7.5 Upd 3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.179Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:27:04",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10916",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10916",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10935
Vulnerability from cvelistv5
Published
2019-07-11 21:17
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known.
References
Impacted products
Vendor Product Version
Siemens AG SIMATIC PCS 7 V8.1 Version: All versions < V8.1 with WinCC V7.3 Upd 19
Siemens AG SIMATIC PCS 7 V8.2 Version: All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11
Siemens AG SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11
Siemens AG SIMATIC WinCC Professional (TIA Portal V13) Version: All versions
Siemens AG SIMATIC WinCC Professional (TIA Portal V14) Version: All versions < V14 SP1 Upd 9
Siemens AG SIMATIC WinCC Professional (TIA Portal V15) Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC Runtime Professional V13 Version: All versions
Siemens AG SIMATIC WinCC Runtime Professional V14 Version: All versions < V14.1 Upd 8
Siemens AG SIMATIC WinCC Runtime Professional V15 Version: All versions < V15.1 Upd 3
Siemens AG SIMATIC WinCC V7.2 and earlier Version: All versions
Siemens AG SIMATIC WinCC V7.3 Version: All versions < V7.3 Upd 19
Siemens AG SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Upd 11
Siemens AG SIMATIC WinCC V7.5 Version: All versions < V7.5 Upd 3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.303Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Professional (TIA Portal V13)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Professional (TIA Portal V14)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Professional (TIA Portal V15)",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434: Unrestricted Upload of File with Dangerous Type",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-10T13:49:24",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10935",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Professional (TIA Portal V13)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Professional (TIA Portal V14)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Professional (TIA Portal V15)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). The SIMATIC WinCC DataMonitor web application of the affected products allows to upload arbitrary ASPX code. The security vulnerability could be exploited by an authenticated attacker with network access to the WinCC DataMonitor application. No user interaction is required to exploit this vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the affected device. At the stage of publishing this security advisory no public exploitation is known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434: Unrestricted Upload of File with Dangerous Type"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-121293.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10935",
    "datePublished": "2019-07-11T21:17:47",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.303Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-19282
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Summary
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition. Successful exploitation requires no system privileges and no user interaction.
Impacted products
Vendor Product Version
Siemens OpenPCS 7 V8.2 Version: All versions
Siemens OpenPCS 7 V9.0 Version: All versions < V9.0 Upd3
Siemens SIMATIC BATCH V8.1 Version: All versions
Siemens SIMATIC BATCH V8.2 Version: All versions < V8.2 Upd12
Siemens SIMATIC BATCH V9.0 Version: All versions < V9.0 SP1 Upd5
Siemens SIMATIC NET PC Software V14 Version: All versions < V14 SP1 Update 14
Siemens SIMATIC NET PC Software V15 Version: All versions
Siemens SIMATIC NET PC Software V16 Version: All versions < V16 Update 1
Siemens SIMATIC PCS 7 V8.1 Version: All versions
Siemens SIMATIC PCS 7 V8.2 Version: All versions
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP3
Siemens SIMATIC Route Control V8.1 Version: All versions
Siemens SIMATIC Route Control V8.2 Version: All versions
Siemens SIMATIC Route Control V9.0 Version: All versions < V9.0 Upd4
Siemens SIMATIC WinCC (TIA Portal) V13 Version: All versions < V13 SP2
Siemens SIMATIC WinCC (TIA Portal) V14 Version: All versions < V14 SP1 Update 10
Siemens SIMATIC WinCC (TIA Portal) V15.1 Version: All versions < V15.1 Update 5
Siemens SIMATIC WinCC (TIA Portal) V16 Version: All versions < V16 Update 1
Siemens SIMATIC WinCC V7.3 Version: All versions
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 14
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP1 Update 1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:09:39.657Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 Upd3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 Upd12"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP1 Upd5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC (TIA Portal) V15.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 14"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP1 Update 1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd12), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions \u003c V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions \u003c V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-131",
              "description": "CWE-131: Incorrect Calculation of Buffer Size",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:49.748Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-19282",
    "datePublished": "2020-03-10T19:16:17",
    "dateReserved": "2019-11-26T00:00:00",
    "dateUpdated": "2024-08-05T02:09:39.657Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-48363
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-09-10 09:36
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain unorganized RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
Impacted products
Vendor Product Version
Siemens SIMATIC BATCH V9.1 Version: All versions < V9.1 SP2 UC05
Siemens SIMATIC PCS 7 V9.1 Version: 0   < V9.1 SP2 UC05
Siemens SIMATIC Route Control V9.1 Version: All versions < V9.1 SP2 UC05
Siemens SIMATIC WinCC Runtime Professional V18 Version: 0   < V18 Update 4
Siemens SIMATIC WinCC Runtime Professional V19 Version: 0   < V19 Update 2
Siemens SIMATIC WinCC V7.4 Version: 0   < *
Siemens SIMATIC WinCC V7.5 Version: 0   < V7.5 SP2 Update 15
Siemens SIMATIC WinCC V8.0 Version: 0   < V8.0 Update 4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-48363",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-13T16:37:22.994141Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:21:43.194Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T21:30:34.556Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2 UC05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2 UC05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 UC05",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2 UC05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V18 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.5 SP2 Update 15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:36:22.958Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-48363",
    "datePublished": "2024-02-13T08:59:55.432Z",
    "dateReserved": "2023-11-15T17:20:32.751Z",
    "dateUpdated": "2024-09-10T09:36:22.958Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-40364
Vulnerability from cvelistv5
Published
2021-11-09 11:32
Modified
2024-08-04 02:44
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.0 Version: All versions < V9.0 SP3 UC04
Siemens SIMATIC PCS 7 V9.1 Version: All versions < V9.1 SP1
Siemens SIMATIC WinCC V15 and earlier Version: All versions < V15 SP1 Update 7
Siemens SIMATIC WinCC V16 Version: All versions < V16 Update 5
Siemens SIMATIC WinCC V17 Version: All versions < V17 Update 2
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 19
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP2 Update 5
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:09.470Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP3 UC04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V15 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15 SP1 Update 7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP2 Update 5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532: Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:02:00.354Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-40364",
    "datePublished": "2021-11-09T11:32:06",
    "dateReserved": "2021-09-01T00:00:00",
    "dateUpdated": "2024-08-04T02:44:09.470Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2023-48364
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-09-10 09:36
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
Impacted products
Vendor Product Version
Siemens SIMATIC BATCH V9.1 Version: All versions < V9.1 SP2 UC05
Siemens SIMATIC PCS 7 V9.1 Version: 0   < V9.1 SP2 UC05
Siemens SIMATIC Route Control V9.1 Version: All versions < V9.1 SP2 UC05
Siemens SIMATIC WinCC Runtime Professional V18 Version: 0   < V18 Update 4
Siemens SIMATIC WinCC Runtime Professional V19 Version: 0   < V19 Update 2
Siemens SIMATIC WinCC V7.4 Version: 0   < *
Siemens SIMATIC WinCC V7.5 Version: 0   < V7.5 SP2 Update 15
Siemens SIMATIC WinCC V8.0 Version: 0   < V8.0 Update 4
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-48364",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-13T16:04:15.175349Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T17:21:43.053Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T21:30:34.447Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2 UC05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2 UC05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 UC05",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP2 UC05"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V18 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.5 SP2 Update 15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.0 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-476",
              "description": "CWE-476: NULL Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:36:24.190Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2023-48364",
    "datePublished": "2024-02-13T08:59:56.648Z",
    "dateReserved": "2023-11-15T17:20:32.751Z",
    "dateUpdated": "2024-09-10T09:36:24.190Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-40363
Vulnerability from cvelistv5
Published
2022-02-09 15:17
Modified
2024-08-04 02:44
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
Impacted products
Vendor Product Version
Siemens SIMATIC PCS 7 V9.0 Version: All versions
Siemens SIMATIC PCS 7 V9.1 Version: All versions < V9.1 SP1
Siemens SIMATIC WinCC V15 and earlier Version: All versions < V15 SP1 Update 7
Siemens SIMATIC WinCC V16 Version: All versions < V16 Update 5
Siemens SIMATIC WinCC V17 Version: All versions < V17 Update 2
Siemens SIMATIC WinCC V17 Version: All versions <= V17 Update 4
Siemens SIMATIC WinCC V7.4 Version: All versions < V7.4 SP1 Update 19
Siemens SIMATIC WinCC V7.5 Version: All versions < V7.5 SP2 Update 6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:09.640Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.1 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V15 and earlier",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15 SP1 Update 7"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c= V17 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP2 Update 6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-538",
              "description": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:17:13",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-40363",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.1 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V15 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15 SP1 Update 7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V16",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16 Update 5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V17",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V17 Update 2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V17",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c= V17 Update 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Update 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 SP2 Update 6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions \u003c V15 SP1 Update 7), SIMATIC WinCC V16 (All versions \u003c V16 Update 5), SIMATIC WinCC V17 (All versions \u003c V17 Update 2), SIMATIC WinCC V17 (All versions \u003c= V17 Update 4), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-538: Insertion of Sensitive Information into Externally-Accessible File or Directory"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-914168.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-40363",
    "datePublished": "2022-02-09T15:17:04",
    "dateReserved": "2021-09-01T00:00:00",
    "dateUpdated": "2024-08-04T02:44:09.640Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",