FKIE_CVE-2022-24287
Vulnerability from fkie_nvd - Published: 2022-05-20 13:15 - Updated: 2024-11-21 06:50
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_pcs_7 | * | |
| siemens | simatic_pcs_7 | 9.1 | |
| siemens | simatic_wincc | * | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc | 7.5 | |
| siemens | simatic_wincc_runtime_professional | * | |
| siemens | simatic_wincc_runtime_professional | 17 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DFA18372-7E7D-4C51-8FA0-EE193DECB88D",
"versionEndIncluding": "9.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.1:*:*:*:*:*:*:*",
"matchCriteriaId": "8852CFC7-FE90-4654-9F85-9181884F948E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CA2E9785-246F-496B-9139-02E2F4003352",
"versionEndIncluding": "7.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
"matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
"matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
"matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
"matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2:*:*:*:*:*:*",
"matchCriteriaId": "3422B714-DB0F-4EE3-A7D4-9A0165214563",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update1:*:*:*:*:*:*",
"matchCriteriaId": "70B79B00-F61D-4F10-AD7B-74718F061D9E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update2:*:*:*:*:*:*",
"matchCriteriaId": "A8766442-CC8D-4221-89B8-F75D195F71E8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update3:*:*:*:*:*:*",
"matchCriteriaId": "26C08FB9-AFEB-4A53-AAB3-37C9717B30C5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update4:*:*:*:*:*:*",
"matchCriteriaId": "68896900-7FCC-4BFB-B787-8992B459F00D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update5:*:*:*:*:*:*",
"matchCriteriaId": "1059B529-02F0-4C85-A35E-2282546FA990",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update6:*:*:*:*:*:*",
"matchCriteriaId": "938D44C5-7B26-4400-970D-B3AA50DDD055",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp2_update7:*:*:*:*:*:*",
"matchCriteriaId": "E9E28D92-0643-4967-94C5-8B8F414158A3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EC34D005-A65F-4AFE-BF1F-53A5AC950A22",
"versionEndIncluding": "16",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:17:*:*:*:*:*:*:*",
"matchCriteriaId": "9B76C5CC-652F-4117-8214-E219C12AA082",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3 UC06), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 and earlier (All versions), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Upd4), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 21), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 8). A missing printer configuration on the host could allow an authenticated attacker to escape the WinCC Kiosk Mode."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V9.0 y anteriores (Todas las versiones), SIMATIC PCS 7 V9.1 (Todas las versiones anteriores V9.1 SP1 UC01), SIMATIC WinCC Runtime Professional V16 y anteriores (Todas las versiones), SIMATIC WinCC Runtime Professional V17 (Todas las versiones anteriores V17 Upd4), SIMATIC WinCC V7.4 y anteriores (Todas las versiones), SIMATIC WinCC V7.5 (Todas las versiones anteriores V7.5 SP2 Update 8). Un atacante autenticado podr\u00eda escapar del modo quiosco de WinCC abriendo el cuadro de di\u00e1logo de la impresora en la aplicaci\u00f3n afectada en caso de que no haya ninguna impresora instalada"
}
],
"id": "CVE-2022-24287",
"lastModified": "2024-11-21T06:50:05.667",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
},
"published": "2022-05-20T13:15:14.680",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-363107.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-1188"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-1188"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.