FKIE_CVE-2020-25238
Vulnerability from fkie_nvd - Published: 2021-02-09 17:15 - Updated: 2024-11-21 05:17
Severity ?
Summary
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf | Vendor Advisory | |
| productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05 | Third Party Advisory, US Government Resource, VDB Entry | |
| productcert@siemens.com | https://www.kb.cert.org/vuls/id/466044 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05 | Third Party Advisory, US Government Resource, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.kb.cert.org/vuls/id/466044 | Third Party Advisory, US Government Resource |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_process_control_system_neo | * | |
| siemens | totally_integrated_automation_portal | 15 | |
| siemens | totally_integrated_automation_portal | 15.1 | |
| siemens | totally_integrated_automation_portal | 16 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*",
"matchCriteriaId": "40B25C24-0170-4C7F-A226-88664D588501",
"versionEndExcluding": "3.1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*",
"matchCriteriaId": "A5BC801E-9D78-4CD4-A457-00ABD5991515",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*",
"matchCriteriaId": "11595F0A-45CA-4A06-A4E0-2F805B7514FE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*",
"matchCriteriaId": "2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en PCS neo (Consola de administraci\u00f3n) (Todas las versiones anteriores a la versi\u00f3n V3.1), TIA Portal (V15, V15.1 y V16). La manipulaci\u00f3n de determinados archivos en carpetas espec\u00edficas podr\u00eda permitir a un atacante local ejecutar c\u00f3digo con privilegios SYSTEM. La vulnerabilidad de seguridad podr\u00eda ser aprovechada por un atacante con una cuenta v\u00e1lida y derechos de acceso limitados en el sistema"
}
],
"id": "CVE-2020-25238",
"lastModified": "2024-11-21T05:17:44.127",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-02-09T17:15:13.610",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource",
"VDB Entry"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource",
"VDB Entry"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-427"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-25238 (GCVE-0-2020-25238)
Vulnerability from cvelistv5 – Published: 2021-02-09 15:38 – Updated: 2024-08-04 15:33
VLAI?
Summary
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | PCS neo (Administration Console) |
Affected:
All versions < V3.1
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.412Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PCS neo (Administration Console)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1"
}
]
},
{
"product": "TIA Portal",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V15, V15.1 and V16"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:11",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-25238",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PCS neo (Administration Console)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.1"
}
]
}
},
{
"product_name": "TIA Portal",
"version": {
"version_data": [
{
"version_value": "V15, V15.1 and V16"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"refsource": "CERT-VN",
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-25238",
"datePublished": "2021-02-09T15:38:18",
"dateReserved": "2020-09-10T00:00:00",
"dateUpdated": "2024-08-04T15:33:05.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25238 (GCVE-0-2020-25238)
Vulnerability from nvd – Published: 2021-02-09 15:38 – Updated: 2024-08-04 15:33
VLAI?
Summary
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | PCS neo (Administration Console) |
Affected:
All versions < V3.1
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.412Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PCS neo (Administration Console)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1"
}
]
},
{
"product": "TIA Portal",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V15, V15.1 and V16"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:11",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-25238",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PCS neo (Administration Console)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.1"
}
]
}
},
{
"product_name": "TIA Portal",
"version": {
"version_data": [
{
"version_value": "V15, V15.1 and V16"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"refsource": "CERT-VN",
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-25238",
"datePublished": "2021-02-09T15:38:18",
"dateReserved": "2020-09-10T00:00:00",
"dateUpdated": "2024-08-04T15:33:05.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}