CVE-2020-25238 (GCVE-0-2020-25238)
Vulnerability from cvelistv5 – Published: 2021-02-09 15:38 – Updated: 2024-08-04 15:33
VLAI?
Summary
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | PCS neo (Administration Console) |
Affected:
All versions < V3.1
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:33:05.412Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PCS neo (Administration Console)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1"
}
]
},
{
"product": "TIA Portal",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "V15, V15.1 and V16"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-14T10:47:11",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-25238",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PCS neo (Administration Console)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.1"
}
]
}
},
{
"product_name": "TIA Portal",
"version": {
"version_data": [
{
"version_value": "V15, V15.1 and V16"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf"
},
{
"name": "VU#466044",
"refsource": "CERT-VN",
"url": "https://www.kb.cert.org/vuls/id/466044"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-25238",
"datePublished": "2021-02-09T15:38:18",
"dateReserved": "2020-09-10T00:00:00",
"dateUpdated": "2024-08-04T15:33:05.412Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.1\", \"matchCriteriaId\": \"40B25C24-0170-4C7F-A226-88664D588501\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A5BC801E-9D78-4CD4-A457-00ABD5991515\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"11595F0A-45CA-4A06-A4E0-2F805B7514FE\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en PCS neo (Consola de administraci\\u00f3n) (Todas las versiones anteriores a la versi\\u00f3n V3.1), TIA Portal (V15, V15.1 y V16). La manipulaci\\u00f3n de determinados archivos en carpetas espec\\u00edficas podr\\u00eda permitir a un atacante local ejecutar c\\u00f3digo con privilegios SYSTEM. La vulnerabilidad de seguridad podr\\u00eda ser aprovechada por un atacante con una cuenta v\\u00e1lida y derechos de acceso limitados en el sistema\"}]",
"id": "CVE-2020-25238",
"lastModified": "2024-11-21T05:17:44.127",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-02-09T17:15:13.610",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\", \"VDB Entry\"]}, {\"url\": \"https://www.kb.cert.org/vuls/id/466044\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\", \"VDB Entry\"]}, {\"url\": \"https://www.kb.cert.org/vuls/id/466044\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-427\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-25238\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-02-09T17:15:13.610\",\"lastModified\":\"2024-11-21T05:17:44.127\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en PCS neo (Consola de administraci\u00f3n) (Todas las versiones anteriores a la versi\u00f3n V3.1), TIA Portal (V15, V15.1 y V16). La manipulaci\u00f3n de determinados archivos en carpetas espec\u00edficas podr\u00eda permitir a un atacante local ejecutar c\u00f3digo con privilegios SYSTEM. La vulnerabilidad de seguridad podr\u00eda ser aprovechada por un atacante con una cuenta v\u00e1lida y derechos de acceso limitados en el sistema\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.1\",\"matchCriteriaId\":\"40B25C24-0170-4C7F-A226-88664D588501\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5BC801E-9D78-4CD4-A457-00ABD5991515\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11595F0A-45CA-4A06-A4E0-2F805B7514FE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\",\"VDB Entry\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/466044\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\",\"VDB Entry\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/466044\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…