cve-2020-25238
Vulnerability from cvelistv5
Published
2021-02-09 15:38
Modified
2024-08-04 15:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05 | Third Party Advisory, US Government Resource, VDB Entry | |
productcert@siemens.com | https://www.kb.cert.org/vuls/id/466044 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05 | Third Party Advisory, US Government Resource, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.kb.cert.org/vuls/id/466044 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |||||
---|---|---|---|---|---|---|---|
▼ | Siemens | PCS neo (Administration Console) |
Version: All versions < V3.1 |
||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T15:33:05.412Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf" }, { "name": "VU#466044", "tags": [ "third-party-advisory", "x_refsource_CERT-VN", "x_transferred" ], "url": "https://www.kb.cert.org/vuls/id/466044" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "PCS neo (Administration Console)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1" } ] }, { "product": "TIA Portal", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V15, V15.1 and V16" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-09-14T10:47:11", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf" }, { "name": "VU#466044", "tags": [ "third-party-advisory", "x_refsource_CERT-VN" ], "url": "https://www.kb.cert.org/vuls/id/466044" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-25238", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "PCS neo (Administration Console)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.1" } ] } }, { "product_name": "TIA Portal", "version": { "version_data": [ { "version_value": "V15, V15.1 and V16" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-284: Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf" }, { "name": "VU#466044", "refsource": "CERT-VN", "url": "https://www.kb.cert.org/vuls/id/466044" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-25238", "datePublished": "2021-02-09T15:38:18", "dateReserved": "2020-09-10T00:00:00", "dateUpdated": "2024-08-04T15:33:05.412Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.1\", \"matchCriteriaId\": \"40B25C24-0170-4C7F-A226-88664D588501\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A5BC801E-9D78-4CD4-A457-00ABD5991515\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"11595F0A-45CA-4A06-A4E0-2F805B7514FE\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en PCS neo (Consola de administraci\\u00f3n) (Todas las versiones anteriores a la versi\\u00f3n V3.1), TIA Portal (V15, V15.1 y V16). La manipulaci\\u00f3n de determinados archivos en carpetas espec\\u00edficas podr\\u00eda permitir a un atacante local ejecutar c\\u00f3digo con privilegios SYSTEM. La vulnerabilidad de seguridad podr\\u00eda ser aprovechada por un atacante con una cuenta v\\u00e1lida y derechos de acceso limitados en el sistema\"}]", "id": "CVE-2020-25238", "lastModified": "2024-11-21T05:17:44.127", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 7.2, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 3.9, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2021-02-09T17:15:13.610", "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\", \"VDB Entry\"]}, {\"url\": \"https://www.kb.cert.org/vuls/id/466044\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\", \"VDB Entry\"]}, {\"url\": \"https://www.kb.cert.org/vuls/id/466044\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]", "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-427\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-25238\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-02-09T17:15:13.610\",\"lastModified\":\"2024-11-21T05:17:44.127\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en PCS neo (Consola de administraci\u00f3n) (Todas las versiones anteriores a la versi\u00f3n V3.1), TIA Portal (V15, V15.1 y V16). La manipulaci\u00f3n de determinados archivos en carpetas espec\u00edficas podr\u00eda permitir a un atacante local ejecutar c\u00f3digo con privilegios SYSTEM. La vulnerabilidad de seguridad podr\u00eda ser aprovechada por un atacante con una cuenta v\u00e1lida y derechos de acceso limitados en el sistema\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":7.2,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-427\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.1\",\"matchCriteriaId\":\"40B25C24-0170-4C7F-A226-88664D588501\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5BC801E-9D78-4CD4-A457-00ABD5991515\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11595F0A-45CA-4A06-A4E0-2F805B7514FE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E1E7FB1-03AF-4AF0-B1A6-3AF65C818596\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\",\"VDB Entry\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/466044\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\",\"VDB Entry\"]},{\"url\":\"https://www.kb.cert.org/vuls/id/466044\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.