var-202102-0296
Vulnerability from variot
A vulnerability has been identified in PCS neo (Administration Console) (All versions < V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. Siemens Totally Integrated Administrator (TIA) fails to properly set the module search path to be used by a privileged Node.js component, which can allow an unprivileged Windows user to run arbitrary code with SYSTEM privileges. The PCS neo administration console is reported to be affected as well.CVE-2020-25238 AffectedCVE-2020-25238 Affected. TIA Administrator is a web-based framework that can contain different functional modules for management tasks, as well as functions for managing SIMATIC software and licenses.
Siemens TIA Administrator has a privilege escalation vulnerability
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0296", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic process control system neo", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "simatic pcs neo", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "totally integrated automation \u30dd\u30fc\u30bf\u30eb", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "tia portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v16" }, { "model": "pcs neo", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "tia portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v15" }, { "model": "tia portal", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "v15.1" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-11833" }, { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "NVD", "id": "CVE-2020-25238" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_process_control_system_neo:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.1", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-25238" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "This document was written by Will Dormann.Statement Date:\u00a0\u00a0 February 09, 2021", "sources": [ { "db": "CERT/CC", "id": "VU#466044" } ], "trust": 0.8 }, "cve": "CVE-2020-25238", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.2, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-25238", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CNVD-2021-11833", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-25238", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-25238", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2021-11833", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202102-891", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-11833" }, { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "NVD", "id": "CVE-2020-25238" }, { "db": "CNNVD", "id": "CNNVD-202102-891" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in PCS neo (Administration Console) (All versions \u003c V3.1), TIA Portal (V15, V15.1 and V16). Manipulating certain files in specific folders could allow a local attacker to execute code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. Siemens Totally Integrated Administrator (TIA) fails to properly set the module search path to be used by a privileged Node.js component, which can allow an unprivileged Windows user to run arbitrary code with SYSTEM privileges. The PCS neo administration console is reported to be affected as well.CVE-2020-25238 AffectedCVE-2020-25238 Affected. TIA Administrator is a web-based framework that can contain different functional modules for management tasks, as well as functions for managing SIMATIC software and licenses. \n\r\n\r\nSiemens TIA Administrator has a privilege escalation vulnerability", "sources": [ { "db": "NVD", "id": "CVE-2020-25238" }, { "db": "CERT/CC", "id": "VU#466044" }, { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "CNVD", "id": "CNVD-2021-11833" } ], "trust": 2.88 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-25238", "trust": 3.8 }, { "db": "CERT/CC", "id": "VU#466044", "trust": 3.2 }, { "db": "ICS CERT", "id": "ICSA-21-040-05", "trust": 2.4 }, { "db": "SIEMENS", "id": "SSA-428051", "trust": 2.2 }, { "db": "JVN", "id": "JVNVU91083521", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2020-015981", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-11833", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202102-891", "trust": 0.6 } ], "sources": [ { "db": "CERT/CC", "id": "VU#466044" }, { "db": "CNVD", "id": "CNVD-2021-11833" }, { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "NVD", "id": "CVE-2020-25238" }, { "db": "CNNVD", "id": "CNNVD-202102-891" } ] }, "id": "VAR-202102-0296", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-11833" } ], "trust": 1.4692307666666666 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-11833" } ] }, "last_update_date": "2023-12-18T10:51:01.180000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-428051", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf" }, { "title": "Patch for Siemens TIA Administrator privilege escalation vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/248781" }, { "title": "Multiple Siemens product Fixes for access control error vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=141312" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-11833" }, { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "CNNVD", "id": "CNNVD-202102-891" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-427", "trust": 1.0 }, { "problemtype": "Inappropriate access control (CWE-284) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "NVD", "id": "CVE-2020-25238" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.0, "url": "https://www.kb.cert.org/vuls/id/466044" }, { "trust": 3.0, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-05" }, { "trust": 2.2, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-428051.pdf" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu91083521" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-25238" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-11833" }, { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "NVD", "id": "CVE-2020-25238" }, { "db": "CNNVD", "id": "CNNVD-202102-891" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CERT/CC", "id": "VU#466044" }, { "db": "CNVD", "id": "CNVD-2021-11833" }, { "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "db": "NVD", "id": "CVE-2020-25238" }, { "db": "CNNVD", "id": "CNNVD-202102-891" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-02-09T00:00:00", "db": "CERT/CC", "id": "VU#466044" }, { "date": "2021-02-22T00:00:00", "db": "CNVD", "id": "CNVD-2021-11833" }, { "date": "2021-10-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "date": "2021-02-09T17:15:13.610000", "db": "NVD", "id": "CVE-2020-25238" }, { "date": "2021-02-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202102-891" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-02-09T00:00:00", "db": "CERT/CC", "id": "VU#466044" }, { "date": "2021-04-12T00:00:00", "db": "CNVD", "id": "CNVD-2021-11833" }, { "date": "2021-10-29T08:04:00", "db": "JVNDB", "id": "JVNDB-2020-015981" }, { "date": "2022-10-21T18:21:51.103000", "db": "NVD", "id": "CVE-2020-25238" }, { "date": "2022-10-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202102-891" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202102-891" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens Totally Integrated Automation Portal vulnerable to privilege escalation due to Node.js paths", "sources": [ { "db": "CERT/CC", "id": "VU#466044" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202102-891" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.