Search criteria

33 vulnerabilities found for simatic_s7-1500_software_controller by siemens

FKIE_CVE-2022-30694

Vulnerability from fkie_nvd - Published: 2022-11-08 11:15 - Updated: 2024-11-21 07:03
Summary
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
Impacted products
Vendor Product Version
siemens simatic_s7-1500_software_controller -
siemens simatic_s7-plcsim_advanced -
siemens simatic_wincc_runtime -
siemens 6es7154-8fb01-0ab0_firmware *
siemens 6es7154-8fb01-0ab0 -
siemens 6es7154-8ab01-0ab0_firmware *
siemens 6es7154-8ab01-0ab0 -
siemens 6es7154-8fx00-0ab0_firmware *
siemens 6es7154-8fx00-0ab0 -
siemens 6es7151-8ab01-0ab0_firmware *
siemens 6es7151-8ab01-0ab0 -
siemens 6es7151-8fb01-0ab0_firmware *
siemens 6es7151-8fb01-0ab0 -
siemens 6es7314-6eh04-0ab0_firmware *
siemens 6es7314-6eh04-0ab0 -
siemens 6es7315-2eh14-0ab0_firmware *
siemens 6es7315-2eh14-0ab0 -
siemens 6es7315-2fj14-0ab0_firmware *
siemens 6es7315-2fj14-0ab0 -
siemens 6es7315-7tj10-0ab0_firmware *
siemens 6es7315-7tj10-0ab0 -
siemens 6es7317-2ek14-0ab0_firmware *
siemens 6es7317-2ek14-0ab0 -
siemens 6es7317-2fk14-0ab0_firmware *
siemens 6es7317-2fk14-0ab0 -
siemens 6es7317-7tk10-0ab0_firmware *
siemens 6es7317-7tk10-0ab0 -
siemens 6es7317-7ul10-0ab0_firmware *
siemens 6es7317-7ul10-0ab0 -
siemens 6es7318-3el01-0ab0_firmware *
siemens 6es7318-3el01-0ab0 -
siemens 6es7318-3fl01-0ab0_firmware *
siemens 6es7318-3fl01-0ab0 -
siemens 6ag1151-8ab01-7ab0_firmware *
siemens 6ag1151-8ab01-7ab0 -
siemens 6ag1151-8fb01-2ab0_firmware *
siemens 6ag1151-8fb01-2ab0 -
siemens 6ag1314-6eh04-7ab0_firmware *
siemens 6ag1314-6eh04-7ab0 -
siemens 6ag1315-2eh14-7ab0_firmware *
siemens 6ag1315-2eh14-7ab0 -
siemens 6ag1315-2fj14-2ab0_firmware *
siemens 6ag1315-2fj14-2ab0 -
siemens 6ag1317-2ek14-7ab0_firmware *
siemens 6ag1317-2ek14-7ab0 -
siemens 6ag1317-2fk14-2ab0_firmware *
siemens 6ag1317-2fk14-2ab0 -
siemens sinumerik_one_firmware -
siemens sinumerik_one -
siemens simatic_pcs_firmware *
siemens simatic_pcs -
siemens simatic_drive_controller_cpu_1504d_tf_firmware -
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware -
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_s7-400_pn\/dp_v7_firmware -
siemens simatic_s7-400_pn\/dp_v7 -
siemens simatic_s7-400_pn\/dp_v6_firmware -
siemens simatic_s7-400_pn\/dp_v6 -
siemens simatic_s7-1500_cpu_1507s_firmware -
siemens simatic_s7-1500_cpu_1507s -
siemens simatic_s7-1500_cpu_1507s_f_firmware -
siemens simatic_s7-1500_cpu_1507s_f -
siemens simatic_s7-1500_cpu_1508s_firmware -
siemens simatic_s7-1500_cpu_1508s -
siemens simatic_s7-1500_cpu_1508s_f_firmware -
siemens simatic_s7-1500_cpu_1508s_f -
siemens simatic_s7-1500_cpu_1510sp_firmware -
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1510sp-1_firmware -
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1511-1_firmware -
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511-1_pn_firmware -
siemens simatic_s7-1500_cpu_1511-1_pn -
siemens simatic_s7-1500_cpu_1511c_firmware -
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1511c-1_firmware -
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware -
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511f-1_pn_firmware -
siemens simatic_s7-1500_cpu_1511f-1_pn -
siemens simatic_s7-1500_cpu_1511t-1_firmware -
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware -
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c_firmware -
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-1500_cpu_1512c-1_firmware -
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware -
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware -
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware -
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513-1_pn_firmware -
siemens simatic_s7-1500_cpu_1513-1_pn -
siemens simatic_s7-1500_cpu_1513f-1_firmware -
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513f-1_pn_firmware -
siemens simatic_s7-1500_cpu_1513f-1_pn -
siemens simatic_s7-1500_cpu_1513r-1_firmware -
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_151511c-1_firmware -
siemens simatic_s7-1500_cpu_151511c-1 -
siemens simatic_s7-1500_cpu_151511f-1_firmware -
siemens simatic_s7-1500_cpu_151511f-1 -
siemens simatic_s7-1500_cpu_1515-2_firmware -
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515-2_pn_firmware -
siemens simatic_s7-1500_cpu_1515-2_pn -
siemens simatic_s7-1500_cpu_1515f-2_firmware -
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515f-2_pn_firmware -
siemens simatic_s7-1500_cpu_1515f-2_pn -
siemens simatic_s7-1500_cpu_1515r-2_firmware -
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware -
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware -
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware -
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516-3_dp_firmware -
siemens simatic_s7-1500_cpu_1516-3_dp -
siemens simatic_s7-1500_cpu_1516-3_pn_firmware -
siemens simatic_s7-1500_cpu_1516-3_pn -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516f-3_firmware -
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516pro_f_firmware -
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware -
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516t-3_firmware -
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware -
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware -
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517-3_dp_firmware -
siemens simatic_s7-1500_cpu_1517-3_dp -
siemens simatic_s7-1500_cpu_1517-3_pn_firmware -
siemens simatic_s7-1500_cpu_1517-3_pn -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517f-3_firmware -
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517tf-3_firmware -
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518_firmware -
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1518-4_firmware -
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518-4_dp_firmware -
siemens simatic_s7-1500_cpu_1518-4_dp -
siemens simatic_s7-1500_cpu_1518-4_pn_firmware -
siemens simatic_s7-1500_cpu_1518-4_pn -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens simatic_s7-1500_cpu_1518f-4_firmware -
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518hf-4_firmware -
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware -
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware -
siemens simatic_s7-1500_cpu_1518tf-4 -
siemens simatic_s7-1500_cpu_15pro-2_firmware -
siemens simatic_s7-1500_cpu_15pro-2 -
siemens simatic_s7-1500_cpu_15prof-2_firmware -
siemens simatic_s7-1500_cpu_15prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware -
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware -
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1200_cpu_12_1211c_firmware -
siemens simatic_s7-1200_cpu_12_1211c -
siemens simatic_s7-1200_cpu_12_1212c_firmware -
siemens simatic_s7-1200_cpu_12_1212c -
siemens simatic_s7-1200_cpu_12_1212fc_firmware -
siemens simatic_s7-1200_cpu_12_1212fc -
siemens simatic_s7-1200_cpu_12_1214c_firmware -
siemens simatic_s7-1200_cpu_12_1214c -
siemens simatic_s7-1200_cpu_12_1214fc_firmware -
siemens simatic_s7-1200_cpu_12_1214fc -
siemens simatic_s7-1200_cpu_12_1215c_firmware -
siemens simatic_s7-1200_cpu_12_1215c -
siemens simatic_s7-1200_cpu_12_1215fc_firmware -
siemens simatic_s7-1200_cpu_12_1215fc -
siemens simatic_s7-1200_cpu_12_1217c_firmware -
siemens simatic_s7-1200_cpu_12_1217c -
siemens simatic_s7-1200_cpu_1211c_firmware -
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware -
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware -
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware -
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware -
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214fc_firmware -
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware -
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware -
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1215fc_firmware -
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1217c_firmware -
siemens simatic_s7-1200_cpu_1217c -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D089914D-13D3-4346-82C3-303C1D1023F5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6584B524-B508-4B21-B0B3-40F41B4A6EAA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "1116304B-6CD9-4D44-BC95-B945D82873A4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7154-8fb01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA0474B6-F38C-4B1E-9ADA-3F0270C47E7C",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7154-8fb01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A0248D0-EF8E-4AD1-ABBF-8D1B7ED5F08C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7154-8ab01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24ACA600-CC4E-4252-BC75-1F1D44D30417",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7154-8ab01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C2DC1DE-A7FC-42F2-B5A7-6BB98A94E6EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7154-8fx00-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0919DB8-4142-46E4-81AB-AF945441F9CE",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7154-8fx00-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8252730-0DD4-4F77-95CC-92907244F4E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7151-8ab01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "435258BB-C910-4ED3-81A5-91B8F5CC6B8D",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7151-8ab01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4992DF18-3BD8-47B4-A36F-8557C33948D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7151-8fb01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCE82634-A022-4F94-85A5-AF2BD98E31CD",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7151-8fb01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE90BEC1-198E-4134-A14D-2D8D1673168C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7314-6eh04-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2404CD50-DA2D-4FB0-8387-3BD1AEE77719",
              "versionEndExcluding": "3.3.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7314-6eh04-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "577E4267-C1E8-4DBD-BADF-ABCD7234665A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7315-2eh14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8683C7D7-BEE8-4DA5-9F45-D15BD9E48C13",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7315-2eh14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36FD5746-7B92-4931-8581-2421BAEB4A88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7315-2fj14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EF9DC4C-441D-4685-8996-C1155458DC01",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7315-2fj14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94FE624E-CB3E-4ADE-AEB0-21BDA4FC64D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7315-7tj10-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8E36044-A4DA-4F93-AE32-32152C88B4B2",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7315-7tj10-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFA14E2D-A82F-4D52-9F25-1A4AA1957075",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-2ek14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2955CED-04B2-4C6B-9FF0-2AFD4F6AFC49",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-2ek14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1AC60B6-6D26-42A5-A6C0-EFD5467D1F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-2fk14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E384CF1-4153-41E7-A87C-97F68EEB10E2",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-2fk14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "372CDCD9-1F1A-428B-9515-EC81A8A9AC9C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-7tk10-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEF1C2CA-067A-4C66-853F-67643E7AECB6",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-7tk10-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23184657-CB41-4CE2-BD72-54AD4CD63ECE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-7ul10-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54BAA07B-EC8F-466A-8E75-860A775299ED",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-7ul10-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA8D0755-4E3A-4D43-98A0-E1CCE615B3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7318-3el01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A738D3BB-BF24-46D4-BC92-ED40FAF68EE0",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7318-3el01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2529D87B-E231-4405-8148-5E176B5D4F5F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7318-3fl01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3439CE01-CB66-4D43-8452-07F972B7A7C6",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7318-3fl01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "20AA01A1-14BF-4235-BDD4-597CA5233CE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1151-8ab01-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "48C207AB-B37C-4E9C-87EE-54358EFE7FC3",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1151-8ab01-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C1563C8-40FB-4FF7-B55B-F49CBF7D59D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1151-8fb01-2ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B929316E-5032-458F-A823-913D6D2EC392",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1151-8fb01-2ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "56A96DA1-9C0D-4075-89BD-BA0C107A6DBD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1314-6eh04-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C4EADDE-7879-4189-8469-0085422D8318",
              "versionEndExcluding": "3.3.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1314-6eh04-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F94C405-65D0-41E1-9A49-1BA424D26C2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1315-2eh14-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE92915A-271A-4B25-B5AA-BFD19DF3802A",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1315-2eh14-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB350474-986A-4829-81AB-139AE1D41731",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1315-2fj14-2ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEAEC33F-6CA0-4D96-9DA7-52F113ED9422",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1315-2fj14-2ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C9973D1-F914-4970-9584-DBA849B5A374",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1317-2ek14-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64F7BBCD-B399-4E4C-9841-B52279F368C3",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1317-2ek14-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9835211F-F261-43F2-8EE2-C09E0BA64A7F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1317-2fk14-2ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6BA0546-F5A4-4440-9C3F-FA2A5F3581C5",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1317-2fk14-2ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C2EF3C6-D468-4664-A4D9-F1B342746825",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FADF6B2-FFE7-4C4E-BF93-61CAA9368285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE30FFDF-5494-400D-8F88-954A6B1503B9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "00961925-0D80-48C3-BD84-7D4ECF30BCE8",
              "versionEndIncluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pcs:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BEAC421-FE31-4F16-8DB1-B816FDD66D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE44BAF7-B9D7-460E-BA76-9405CBC775A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65963CEF-7071-4D1C-B6BB-EB56909C55E3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A1E779F-1A56-4552-9E82-F881D3B044C0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C48D93F2-FB6B-4D4D-84FB-3A7CDE89B727",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "915E168D-2DF4-4D25-85AC-3684C30985BC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C27A6138-1536-4BCD-B072-B64767140F1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDBDA792-481E-4728-8089-E0E3CF78FCDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39C1392C-38E2-4AF9-AF17-91B93BC6B9B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_f_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6999D835-F9A7-46BA-BF40-39F11F50DBDA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1ED29DF-8AC0-4BB6-ACE2-EBC0A2B87F96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F946597D-56D1-4F84-B49A-031D2B6C6A75",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CBD063-6CF0-45E6-A9D1-C7F8709806AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_f_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B78A081-E63E-4712-B3D1-D077CC2ADA39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2079B95-E885-4490-BCEA-62BBEAF9CB51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F419FF16-E351-4881-939C-1FAE5783F18C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306030D2-62E7-4E2C-BABB-9BEA2902F859",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D65CD4C-49ED-4BE6-A166-E30B107B508D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEAB4D7D-BBA9-462F-9801-43B968FED148",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5007FF6-07A4-4C39-A96A-FBA4E64E6C5B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C8D3003-82C6-4D59-A1ED-6897239C62E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA23E9EB-5344-4DBE-81DB-076F310C25C8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3456E2BC-7BF0-4B5B-A8D8-D51E5CED2EA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEEF32EA-F142-42AE-AF7D-CCF026247D67",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D4BD169-6330-44CE-86F2-05F625A805F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE580163-01B8-45EF-8374-7F18131DE91D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C548EAC7-F5FC-40DA-8A5B-4701848036C5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDA4B714-930D-48C8-B8F5-AEDBD32ED70F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C65CBECB-B847-4CDB-B5EE-C5CA9650D233",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B284524-2483-479E-8DB0-2F867C2D94D8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE709858-D53C-4130-BC22-93859394BBDC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E05B43-EB9C-4CDA-A166-21D6A3BF9CA6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE2E6369-80E6-435B-81EE-2CA619DB2792",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ACD393E-404B-441C-A86D-138116A3D235",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8C752CB-BBB9-4B3E-A0D2-7BEDBF1E1CAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA60D4EE-EB60-4B06-B48A-0859999F9F83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CA67D2-620A-4C1A-9D03-3D8D632E6054",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "448DD8BF-6DE3-4B05-A396-6EB1C4FE7968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B921D252-AD63-4CA0-BBF7-EB825BFB6F8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4899D5A4-2FDD-4594-8BEC-40B1C06F7912",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3F212F8-899F-4A6B-A5E7-448EF6B0FF9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "59B6BB2D-602C-4C21-9CF7-E458CB16A85A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2BABE44-5947-4B73-B7F9-CDBFEF75D48E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C482E94F-DCB8-4C5F-9C02-329168201FEB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75108BD0-208A-4D6C-9725-024E8B473DF7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "59AB9211-C748-4519-A10E-2BDD86E9DB3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1F9332E-41DC-491E-A4EE-7F19EB868B8D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5FD1F20-E507-4422-814D-19614CDB49B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7B89339-2A37-48A1-BD48-1D0A9606B633",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "439E1B3E-7174-4BAC-A11A-F4F37ABB7291",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "941EA204-0ACC-4530-8DD7-8EE13B838E43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "394B61E8-68E5-4E18-BCD8-5CF0A03F5562",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0D14325-65B6-4E52-9CF1-9747718E6999",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE7B8BBC-0424-4819-BCB2-F7AA151342F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B73DC49-C581-49C1-9B97-E63B976A2B2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49A379BF-8C3B-4C53-ADD4-D718F54FBE8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48747971-E3B6-4777-AE36-3868CCE063FC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADC9BBE9-49EC-495D-A77C-621D162B601E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97CF55DA-622C-4449-BF4B-CA2943E931B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE53C35-490A-498B-8CAB-B874C0E17AF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8360B6F2-8A2C-4D01-B041-DF8447515B98",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C44E126-E4D9-44D8-B8B9-10F060D63A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31B6D71B-05F8-47D6-9E98-11BA5C118322",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "163D5E50-9D3D-4823-86D8-AB20750FF98D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF0659BF-0AAB-4689-8B66-C934E32882CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B7D515C-3885-48DB-879C-B963A95482F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A7986DD-B46E-46E3-AC4A-A2E6AF062451",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A16F6A0-ED34-4207-AD95-C3F08B8ABFF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0E73EBA-AE4E-4263-B221-3F30056C0589",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6772D5F3-35EE-4C94-B6D5-31500F440CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A90C920C-B31C-48E6-A01A-A28DFF5B5AFD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4245AED2-3F58-40D0-BF8A-8E930E1730B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "105DF0A7-88CD-4145-97D1-37301C98FCD6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "79DE73E2-10CF-4E36-B78A-87C9846B4EEC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4F5BF77-21E0-4F5D-A22C-FCD8D3FD33C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F610BF59-5390-4D3C-B082-387CEDF3C75D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8FD1F65-2581-465F-A0F1-FDD792A00300",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "728DE10E-6915-4015-B899-DA21AE885525",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A55BEA90-A2CD-4E13-BCE2-202BF9CB0630",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CB4F9CD-DABF-41B1-9A33-8E2F38AFD171",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E41F61DB-1A84-45AC-8A81-5D986065F45B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C58021F0-40C6-4066-834A-C6F5679CC2BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEBA7381-0C6B-4A47-94D7-0255EEF0CFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7A0687E-BD56-472F-8AC4-A8C8846F2E9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E7578C6-9149-4742-99FF-CB13CEAE8214",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDA87A40-D438-4ABF-9021-AE5672AC25FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3984C91-A38D-4498-9505-4C7894502617",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16E49567-1928-42C1-B8AC-CE283E0276E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6708491-A3CD-4100-BF43-74FB421E7B03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91914E86-2313-46DD-B462-E9C0221B0573",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E75190A-198B-4A8D-9E16-27665A4168D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA5A765-6D88-4DBB-8171-4BEFD52EF346",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAD6D800-87DE-4C8A-B60B-C5AD196D5F54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14993EB3-1896-4040-A05D-CAA3B4CC1466",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D89586C8-CD63-457B-8685-5C50D0592D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD85CC9A-F8F0-436E-B2D4-DD719C482C04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38719F3-6D7A-4200-9146-5C4AFABEB787",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1453CB1-C229-4998-BC19-98CA1146B5D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0155A47-734B-4C2C-8A8A-D6B88507DFB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5477E1A-E37D-483D-B285-7C69538406B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DE62DBA-6865-4D1B-8651-90056C089909",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F179B6C7-9F46-49A2-A5E5-E60A49632981",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D43A3548-B4B4-4D05-BBD6-59A4FA43CFF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47046130-C64B-40D5-B661-19E031B83529",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27A07E24-A6CB-4B74-B35A-EFB3D7E91FB3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE9D91E3-7696-49F9-812D-F4816BD9F655",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBD3361A-95E0-4F8C-B1F8-DDA2DA03805B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C91C60D-1770-4972-A476-EE8BAF31EFFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78B5E474-2B55-491F-9BBD-5341614E2A5F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5679CB0-7C93-4260-BF17-11C4CF56A723",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5220CCF-F39B-45C5-8C60-584412A38583",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack."
    },
    {
      "lang": "es",
      "value": "El endpoint de inicio de sesi\u00f3n /FormLogin en los servicios web afectados no aplica la verificaci\u00f3n de origen adecuada. Esto podr\u00eda permitir a atacantes remotos autenticados rastrear las actividades de otros usuarios mediante un ataque de Cross-Site Request Forgery (CSRF)."
    }
  ],
  "id": "CVE-2022-30694",
  "lastModified": "2024-11-21T07:03:11.067",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-08T11:15:10.413",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2022-38465

Vulnerability from fkie_nvd - Published: 2022-10-11 11:15 - Updated: 2024-11-21 07:16
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.
Impacted products
Vendor Product Version
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200_open_controller_cpu_1515sp_pc2 -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware *
siemens simatic_et_200_open_controller_cpu_1515sp_pc -
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_s7-1200_cpu_12_1211c_firmware *
siemens simatic_s7-1200_cpu_12_1211c -
siemens simatic_s7-1200_cpu_12_1212c_firmware *
siemens simatic_s7-1200_cpu_12_1212c -
siemens simatic_s7-1200_cpu_12_1212fc_firmware *
siemens simatic_s7-1200_cpu_12_1212fc -
siemens simatic_s7-1200_cpu_12_1214fc_firmware *
siemens simatic_s7-1200_cpu_12_1214fc -
siemens simatic_s7-1200_cpu_12_1214c_firmware *
siemens simatic_s7-1200_cpu_12_1214c -
siemens simatic_s7-1200_cpu_12_1215fc_firmware *
siemens simatic_s7-1200_cpu_12_1215fc -
siemens simatic_s7-1200_cpu_12_1215c_firmware *
siemens simatic_s7-1200_cpu_12_1215c -
siemens simatic_s7-1200_cpu_12_1217c_firmware *
siemens simatic_s7-1200_cpu_12_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_151511c-1_firmware *
siemens simatic_s7-1500_cpu_151511c-1 -
siemens simatic_s7-1500_cpu_151511f-1_firmware *
siemens simatic_s7-1500_cpu_151511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_15prof-2_firmware *
siemens simatic_s7-1500_cpu_15prof-2 -
siemens simatic_s7-1500_cpu_15pro-2_firmware *
siemens simatic_s7-1500_cpu_15pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CD32994-47A3-4850-ABC7-FD80353E6063",
              "versionEndExcluding": "21.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF0944C4-8FD7-4B00-85B7-6DB430EAA884",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B96409C7-3198-406D-9BC6-E8B729757A72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E9BE617-A91C-401C-A5CE-88FB06133AF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "604B7AFC-6242-4273-A228-8F158F955058",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D95A4823-1E5E-44A5-9EED-3CB108B711BE",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F090EF99-203C-4411-B64F-B14EF05F7824",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3984C91-A38D-4498-9505-4C7894502617",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CAE3892-EFC5-467F-9A37-70AF97998BDD",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6708491-A3CD-4100-BF43-74FB421E7B03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8C8B48B-652A-40D0-8D88-CB91E5E85DA4",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E75190A-198B-4A8D-9E16-27665A4168D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EFD145F-F918-4C0D-B3F1-D9583229ED7E",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D89586C8-CD63-457B-8685-5C50D0592D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5008384-75BB-4A46-ACE0-7FA260E72C73",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAD6D800-87DE-4C8A-B60B-C5AD196D5F54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42D361D1-8B59-4003-9033-4C1425CC4104",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0155A47-734B-4C2C-8A8A-D6B88507DFB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84C133CD-6944-4B80-B2A9-F5F2B6BA9E79",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38719F3-6D7A-4200-9146-5C4AFABEB787",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97E9A661-7AC3-43B9-A2A1-8508DAF15D6D",
              "versionEndExcluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DE62DBA-6865-4D1B-8651-90056C089909",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A19F329-2F5C-4A4B-83DB-C12020378F6D",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBEAAD76-4CB4-4A05-A2B1-C489AD32E30A",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "553CB199-D592-4B87-A61C-9E903BE21250",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34623019-4E1E-40F9-BC43-0008758BE35C",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA60D4EE-EB60-4B06-B48A-0859999F9F83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "153B1C68-9B90-4E76-B814-3307E57D86AF",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "448DD8BF-6DE3-4B05-A396-6EB1C4FE7968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35ED6E18-CF9D-4CF7-A73F-A7B29147028E",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2262D53-B539-45EA-98E0-1E2B1C4B1A20",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E32A61C-3119-4703-9BC4-8AFAF2DE2767",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA59BA8F-BC5B-4BE8-AF1F-D48E066E300B",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "029BDD36-31A2-4CCE-9CB1-1DB17987112F",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E6874DE-A6D8-47E1-8F1A-C1BA59464F04",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "469219FC-3F67-4AED-8EF1-5C3E46344173",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2DB7B4-963D-40F6-A7CD-21B13365AAEC",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "332600B8-0F6E-4DC2-B0EB-BBC48E3581A9",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEBA7381-0C6B-4A47-94D7-0255EEF0CFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EACD9C79-4F9F-443B-933D-BBC4CE035C74",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E41F61DB-1A84-45AC-8A81-5D986065F45B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87A3783E-DFCB-4C97-90F4-7C1CA93F65F4",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "846D5EB8-2FFD-4E42-B6EB-FEB8E34F2250",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01CDF5DD-7232-469E-9D1D-D3AA789CAAC7",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0283BA76-C739-401B-AF67-2851B8DA4566",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2405AD13-B1B0-4111-B160-5A6B5DF9538B",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F20C4A59-E173-4DCF-AD53-377957FFE3E2",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7A24ABD-347F-49F4-A2A5-0C2D97B55497",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46DDF83F-ED5A-4954-BFCF-DC3CA792386B",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9597869E-13BE-4245-8AAD-20DD83D583A2",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7871C856-52DC-485C-95F4-9AD1BAB6B8AB",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "728919F4-7BEF-4248-B402-0533C724B35A",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CECCEBBE-7A46-452D-B97C-3043218F0D9D",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "807BE9DA-18AC-4965-99C5-6185C99D2AD7",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "36B077A2-CAC7-4E0C-B035-B1A1C0C3FFA5",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F9FE195-4057-4615-8A03-B07899505B50",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDEFE3B3-1F50-4EBC-8CED-A8F8B3EB2E14",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "957DEE17-0D31-4948-862D-153D33A770E9",
              "versionEndExcluding": "21.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINUMERIK MC (All versions \u003c V6.21), SINUMERIK ONE (All versions \u003c V6.21). Affected products  protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.\r\n\r\nThis could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (todas las versiones anteriores a V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS) (todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (todas las versiones anteriores a V21. 9), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a V4.5.0), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a V2.9.2), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a V21.9), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a V4.0). Los productos afectados protegen la clave privada global incorporada de un modo que ya no puede considerarse suficiente. La clave es usada para la protecci\u00f3n heredada de los datos de configuraci\u00f3n confidenciales y la comunicaci\u00f3n heredada PG/PC y HMI. Esto podr\u00eda permitir a atacantes detectar la clave privada de una familia de productos de CPU mediante un ataque fuera de l\u00ednea contra una sola CPU de la familia. Los atacantes podr\u00edan entonces usar este conocimiento para extraer datos de configuraci\u00f3n confidenciales de los proyectos que est\u00e1n protegidos por esa clave o para llevar a cabo ataques contra la comunicaci\u00f3n PG/PC y HMI heredada"
    }
  ],
  "id": "CVE-2022-38465",
  "lastModified": "2024-11-21T07:16:31.843",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 9.3,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.5,
        "impactScore": 6.0,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-10-11T11:15:10.357",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-37204

Vulnerability from fkie_nvd - Published: 2022-02-09 16:15 - Updated: 2024-11-21 06:14
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced_firmware 4.0
siemens simatic_s7-plcsim_advanced -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D04FDFA5-E309-400F-B6BD-009D0540CC58",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC0350F-C61E-46B0-B8D2-278DBFF5FE07",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7606D9B-40D9-4FC1-BFC1-2102D7D0E216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34AEEAA6-3D7E-4A57-99C7-CA51C65DE6AB",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A484657A-315A-420D-B871-690A812A25D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "619B6E3D-04CF-488C-B683-DD41E8FA5A49",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F56E7C9-0CDD-4C38-940E-C1F868972477",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B040DCD8-5290-4D0F-811F-C66B23251A1C",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4B4D0E9-7D6D-429B-954D-BED796A48EE8",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC90834-F984-40D4-AD4A-1AFC0B8CFEE0",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC58EB9-EE55-4A93-B0C0-9D8080A7272D",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13513190-F039-44CC-9314-CD92A31CD913",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06796C2-880A-4B24-A3F5-45765395954E",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BBB092-E84B-400A-8C23-6ACACE2166DA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC2B179-74D4-4501-87DC-9453668B0380",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC67852-31C7-4AD8-BFAE-21185A9032B1",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DA4FA4-4A3D-485E-B7AF-A99D200FEB95",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9EBF937-C08A-481E-A78F-5F1867E8CA72",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "479FD9DE-11AD-4E0D-A156-7AEAAB413340",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B8442FF-5CC9-4375-8CA0-4C40AC9BF3D6",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41110BB6-35DE-474B-9737-F52D3DFEFE74",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850183B0-B28F-4DE4-B946-1A8CEAC8405E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643F8228-B027-4142-96AE-D0634214B558",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE79E08-3046-463B-A435-5E9CDEA1D065",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC37C005-A9C2-4C41-A588-4C55D4B98E2E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AFEF4C-943F-4B28-8ADC-56471309D7EA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84A8E248-282C-4B42-82C2-54C6FE3F5193",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414FDF2-8988-4DAD-AA26-2E6263DE55FB",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D97466FA-5887-401B-8BAA-7B12E13E8670",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46C7835E-2D0F-42FF-AF4F-D1BEB7CFC75D",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B8659AE-88B8-4318-AA52-893C72388CF9",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D97556-8B12-46AD-BCF7-42FD9DAB8F3F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407FC394-6B95-455D-B80D-2B5025684C08",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FBA4611-1221-4BEF-821B-29549044F8C0",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "687833D7-43E0-48CD-BC55-D33BD4654E2A",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C255DAA6-F418-40F1-B47C-FAA18152D648",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47825870-52BD-4EDC-81D0-79DAAA39A9D7",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69C5BA5B-C58A-496C-88E5-496CCD55DF5B",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "398DC87E-ED2D-44BC-A5F0-A6FA6E560A88",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C746F486-CCAB-4D23-8770-8D68659DB5B5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9A5802D-E81B-41D9-85D1-E704DBD84EBE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4730FD89-CBE6-46AF-ACDA-6F987264BDA5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35C381B9-8DD5-400B-8E06-DA7ACCC67C52",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8E98F-AF8D-490E-98A3-00036CF83407",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85594ACB-69DF-4D28-BB19-9F024D5D0D55",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A140FAD2-0FC5-4695-8A13-D6C57777F93F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4426EBD2-DB73-4811-9550-68E77F479DDE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (Todas las versiones anteriores a la versi\u00f3n V2.9.2), la familia SIMATIC Drive Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS) (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (Todas las versiones), Familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V4.5. 0), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V4.5.0 anteriores a la versi\u00f3n V4.5.2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V2.9.2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9. 4), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21.9), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a la versi\u00f3n V4.0), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales a la versi\u00f3n V4.0 anteriores a la versi\u00f3n V4.0 SP1), TIM 1531 IRC (incl. variantes SIPLUS NET) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.2). Un atacante no autenticado podr\u00eda causar una condici\u00f3n de denegaci\u00f3n de servicio en un PLC al enviar un paquete especialmente preparado sobre el puerto 102/tcp. Es necesario reiniciar el dispositivo afectado para restablecer el funcionamiento normal"
    }
  ],
  "id": "CVE-2021-37204",
  "lastModified": "2024-11-21T06:14:51.340",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-02-09T16:15:13.333",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-672"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-37205

Vulnerability from fkie_nvd - Published: 2022-02-09 16:15 - Updated: 2024-11-21 06:14
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced_firmware 4.0
siemens simatic_s7-plcsim_advanced -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D04FDFA5-E309-400F-B6BD-009D0540CC58",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC0350F-C61E-46B0-B8D2-278DBFF5FE07",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7606D9B-40D9-4FC1-BFC1-2102D7D0E216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34AEEAA6-3D7E-4A57-99C7-CA51C65DE6AB",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A484657A-315A-420D-B871-690A812A25D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "619B6E3D-04CF-488C-B683-DD41E8FA5A49",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F56E7C9-0CDD-4C38-940E-C1F868972477",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B040DCD8-5290-4D0F-811F-C66B23251A1C",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4B4D0E9-7D6D-429B-954D-BED796A48EE8",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC90834-F984-40D4-AD4A-1AFC0B8CFEE0",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC58EB9-EE55-4A93-B0C0-9D8080A7272D",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13513190-F039-44CC-9314-CD92A31CD913",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06796C2-880A-4B24-A3F5-45765395954E",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BBB092-E84B-400A-8C23-6ACACE2166DA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC2B179-74D4-4501-87DC-9453668B0380",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC67852-31C7-4AD8-BFAE-21185A9032B1",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DA4FA4-4A3D-485E-B7AF-A99D200FEB95",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9EBF937-C08A-481E-A78F-5F1867E8CA72",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "479FD9DE-11AD-4E0D-A156-7AEAAB413340",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B8442FF-5CC9-4375-8CA0-4C40AC9BF3D6",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41110BB6-35DE-474B-9737-F52D3DFEFE74",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850183B0-B28F-4DE4-B946-1A8CEAC8405E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643F8228-B027-4142-96AE-D0634214B558",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE79E08-3046-463B-A435-5E9CDEA1D065",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC37C005-A9C2-4C41-A588-4C55D4B98E2E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AFEF4C-943F-4B28-8ADC-56471309D7EA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84A8E248-282C-4B42-82C2-54C6FE3F5193",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414FDF2-8988-4DAD-AA26-2E6263DE55FB",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D97466FA-5887-401B-8BAA-7B12E13E8670",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46C7835E-2D0F-42FF-AF4F-D1BEB7CFC75D",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B8659AE-88B8-4318-AA52-893C72388CF9",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D97556-8B12-46AD-BCF7-42FD9DAB8F3F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407FC394-6B95-455D-B80D-2B5025684C08",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FBA4611-1221-4BEF-821B-29549044F8C0",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "687833D7-43E0-48CD-BC55-D33BD4654E2A",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C255DAA6-F418-40F1-B47C-FAA18152D648",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47825870-52BD-4EDC-81D0-79DAAA39A9D7",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69C5BA5B-C58A-496C-88E5-496CCD55DF5B",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "398DC87E-ED2D-44BC-A5F0-A6FA6E560A88",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C746F486-CCAB-4D23-8770-8D68659DB5B5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9A5802D-E81B-41D9-85D1-E704DBD84EBE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4730FD89-CBE6-46AF-ACDA-6F987264BDA5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35C381B9-8DD5-400B-8E06-DA7ACCC67C52",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8E98F-AF8D-490E-98A3-00036CF83407",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85594ACB-69DF-4D28-BB19-9F024D5D0D55",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A140FAD2-0FC5-4695-8A13-D6C57777F93F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4426EBD2-DB73-4811-9550-68E77F479DDE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), la familia de CPU SIMATIC S7-1200 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V4.5.0 anteriores a la versi\u00f3n V4.5. 2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales a la versi\u00f3n V4.0 anteriores a la versi\u00f3n V4.0 SP1), TIM 1531 IRC (incl. variantes SIPLUS NET) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.2). Un atacante no autenticado podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio en un PLC al enviar paquetes especialmente preparados a trav\u00e9s del puerto 102/tcp. Es necesario reiniciar el dispositivo afectado para restablecer el funcionamiento normal anteriores a la versi\u00f3n"
    }
  ],
  "id": "CVE-2021-37205",
  "lastModified": "2024-11-21T06:14:51.527",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-02-09T16:15:13.393",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-401"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-401"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2021-37185

Vulnerability from fkie_nvd - Published: 2022-02-09 16:15 - Updated: 2024-11-21 06:14
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced_firmware 4.0
siemens simatic_s7-plcsim_advanced -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D04FDFA5-E309-400F-B6BD-009D0540CC58",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC0350F-C61E-46B0-B8D2-278DBFF5FE07",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7606D9B-40D9-4FC1-BFC1-2102D7D0E216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34AEEAA6-3D7E-4A57-99C7-CA51C65DE6AB",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A484657A-315A-420D-B871-690A812A25D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "619B6E3D-04CF-488C-B683-DD41E8FA5A49",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F56E7C9-0CDD-4C38-940E-C1F868972477",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B040DCD8-5290-4D0F-811F-C66B23251A1C",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4B4D0E9-7D6D-429B-954D-BED796A48EE8",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC90834-F984-40D4-AD4A-1AFC0B8CFEE0",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC58EB9-EE55-4A93-B0C0-9D8080A7272D",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13513190-F039-44CC-9314-CD92A31CD913",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06796C2-880A-4B24-A3F5-45765395954E",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BBB092-E84B-400A-8C23-6ACACE2166DA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC2B179-74D4-4501-87DC-9453668B0380",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC67852-31C7-4AD8-BFAE-21185A9032B1",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DA4FA4-4A3D-485E-B7AF-A99D200FEB95",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9EBF937-C08A-481E-A78F-5F1867E8CA72",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "479FD9DE-11AD-4E0D-A156-7AEAAB413340",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B8442FF-5CC9-4375-8CA0-4C40AC9BF3D6",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41110BB6-35DE-474B-9737-F52D3DFEFE74",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850183B0-B28F-4DE4-B946-1A8CEAC8405E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643F8228-B027-4142-96AE-D0634214B558",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE79E08-3046-463B-A435-5E9CDEA1D065",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC37C005-A9C2-4C41-A588-4C55D4B98E2E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AFEF4C-943F-4B28-8ADC-56471309D7EA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84A8E248-282C-4B42-82C2-54C6FE3F5193",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414FDF2-8988-4DAD-AA26-2E6263DE55FB",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D97466FA-5887-401B-8BAA-7B12E13E8670",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46C7835E-2D0F-42FF-AF4F-D1BEB7CFC75D",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B8659AE-88B8-4318-AA52-893C72388CF9",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D97556-8B12-46AD-BCF7-42FD9DAB8F3F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407FC394-6B95-455D-B80D-2B5025684C08",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FBA4611-1221-4BEF-821B-29549044F8C0",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "687833D7-43E0-48CD-BC55-D33BD4654E2A",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C255DAA6-F418-40F1-B47C-FAA18152D648",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47825870-52BD-4EDC-81D0-79DAAA39A9D7",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69C5BA5B-C58A-496C-88E5-496CCD55DF5B",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "398DC87E-ED2D-44BC-A5F0-A6FA6E560A88",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C746F486-CCAB-4D23-8770-8D68659DB5B5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9A5802D-E81B-41D9-85D1-E704DBD84EBE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4730FD89-CBE6-46AF-ACDA-6F987264BDA5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35C381B9-8DD5-400B-8E06-DA7ACCC67C52",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8E98F-AF8D-490E-98A3-00036CF83407",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85594ACB-69DF-4D28-BB19-9F024D5D0D55",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A140FAD2-0FC5-4695-8A13-D6C57777F93F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4426EBD2-DB73-4811-9550-68E77F479DDE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), la familia de CPU SIMATIC S7-1200 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V4.5.0 anteriores a la versi\u00f3n V4.5. 2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales a la versi\u00f3n V4.0 anteriores a la versi\u00f3n V4.0 SP1), TIM 1531 IRC (incl. variantes SIPLUS NET) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.2). Un atacante no autenticado podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio en un PLC al enviar paquetes especialmente preparados a trav\u00e9s del puerto 102/tcp. Es necesario reiniciar el dispositivo afectado para restablecer el funcionamiento normal"
    }
  ],
  "id": "CVE-2021-37185",
  "lastModified": "2024-11-21T06:14:48.977",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-02-09T16:15:12.823",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-672"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2020-28397

Vulnerability from fkie_nvd - Published: 2021-08-10 11:15 - Updated: 2024-11-21 05:22
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
Impacted products
Vendor Product Version
siemens cpu_1504d_tf_firmware *
siemens cpu_1504d_tf -
siemens cpu_1507d_tf_firmware *
siemens cpu_1507d_tf -
siemens cpu_1515sp_pc2_tf_firmware *
siemens cpu_1515sp_pc2_tf -
siemens simatic_s7_plcsim_advanced_firmware *
siemens simatic_s7_plcsim_advanced -
siemens simatic_s7-1500_software_controller *
siemens tim_1531_irc_firmware 2.1
siemens tim_1531_irc -
siemens cpu_1211c_firmware 4.4
siemens cpu_1211c -
siemens cpu_1212c_firmware 4.4
siemens cpu_1212c -
siemens cpu_1212fc_firmware 4.4
siemens cpu_1212fc -
siemens cpu_1214fc_firmware 4.4
siemens cpu_1214fc -
siemens cpu_1214c_firmware 4.4
siemens cpu_1214c -
siemens cpu_1215fc_firmware 4.4
siemens cpu_1215fc -
siemens cpu_1215c_firmware 4.4
siemens cpu_1215c -
siemens cpu_1217c_firmware 4.4
siemens cpu_1217c -
siemens siplus_cpu_1510sp_f-1pn_firmware *
siemens siplus_cpu_1510sp_f-1pn -
siemens siplus_cpu_1511-1_pn_firmware *
siemens siplus_cpu_1511-1_pn -
siemens siplus_cpu_1511-1_pn_firmware *
siemens siplus_cpu_1511-1_pn -
siemens siplus_cpu_1511f-1_pn_firmware *
siemens siplus_cpu_1511f-1_pn -
siemens siplus_cpu_1512sp-1_pn_firmware *
siemens siplus_cpu_1512sp-1_pn -
siemens siplus_cpu_1512sp_f-1pn_firmware *
siemens siplus_cpu_1512sp_f-1pn -
siemens siplus_cpu_1513-1_pn_firmware *
siemens siplus_cpu_1513-1_pn -
siemens siplus_cpu_1513-1_pn_firmware *
siemens siplus_cpu_1513-1_pn -
siemens siplus_cpu_1513f-1_pn_firmware *
siemens siplus_cpu_1513f-1_pn -
siemens siplus_cpu_1516-3_pn\/dp_firmware *
siemens siplus_cpu_1516-3_pn\/dp -
siemens siplus_cpu_1516-3_pn\/dp_firmware *
siemens siplus_cpu_1516-3_pn\/dp -
siemens siplus_cpu-1516f-3_pn\/dp_firmware *
siemens siplus_cpu-1516f-3_pn\/dp -
siemens siplus_cpu_1518-4_pn\/dp_firmware *
siemens siplus_cpu_1518-4_pn\/dp -
siemens siplus_cpu_1518f-4_pn\/dp_firmware *
siemens siplus_cpu_1518f-4_pn\/dp -
siemens cpu_1510sp-1pn_firmware *
siemens cpu_1510sp-1pn -
siemens cpu1510sp_f-1_firmware *
siemens cpu1510sp_f-1 -
siemens cpu_1511-1pn_firmware *
siemens cpu_1511-1pn -
siemens cpu_1511-1pn_firmware *
siemens cpu_1511-1pn -
siemens cpu_1511c-1_pn_firmware *
siemens cpu_1511c-1_pn -
siemens cpu_1511f-1pn_firmware *
siemens cpu_1511f-1pn -
siemens cpu_1511t-1pn_firmware *
siemens cpu_1511t-1pn -
siemens cpu_1511tf-1pn_firmware *
siemens cpu_1511tf-1pn -
siemens cpu_1512c-1_pn_firmware *
siemens cpu_1512c-1_pn -
siemens cpu_1512sp-1_pn_firmware *
siemens cpu_1512sp-1_pn -
siemens cpu_1512sp_f-1_pn_firmware *
siemens cpu_1512sp_f-1_pn -
siemens cpu_1513-1_pn_firmware *
siemens cpu_1513-1_pn -
siemens cpu_1513f-1_pn_firmware *
siemens cpu_1513f-1_pn -
siemens cpu_1513r-1_pn_firmware *
siemens cpu_1513r-1_pn -
siemens cpu_1513pro_f-2_pn_firmware *
siemens cpu_1513pro_f-2_pn -
siemens cpu_1515-2_firmware *
siemens cpu_1515-2 -
siemens cpu_1515f-2_firmware *
siemens cpu_1515f-2 -
siemens cpu_1515r-2_pn_firmware *
siemens cpu_1515r-2_pn -
siemens cpu_1515t-2_pn_firmware *
siemens cpu_1515t-2_pn -
siemens cpu_1515tf-2_pn_firmware *
siemens cpu_1515tf-2_pn -
siemens cpu_1516pro_f-2_pn_firmware *
siemens cpu_1516pro_f-2_pn -
siemens cpu_1516pro-2_pn_firmware *
siemens cpu_1516pro-2_pn -
siemens cpu_1516-3_firmware *
siemens cpu_1516-3 -
siemens cpu_1516f-3_firmware *
siemens cpu_1516f-3 -
siemens cpu_1516t-3_pn\/dp_firmware *
siemens cpu_1516t-3_pn\/dp -
siemens cpu_1516tf-3_pn\/dp_firmware *
siemens cpu_1516tf-3_pn\/dp -
siemens cpu_1517-3_pn\/dp_firmware *
siemens cpu_1517-3_pn\/dp -
siemens cpu_1517f-3_pn\/dp_firmware *
siemens cpu_1517f-3_pn\/dp -
siemens cpu_1517t-3_pn\/dp_firmware *
siemens cpu_1517t-3_pn\/dp -
siemens cpu_1517tf-3_pn\/dp_firmware *
siemens cpu_1517tf-3_pn\/dp -
siemens cpu_1518-4_pn\/dp_firmware *
siemens cpu_1518-4_pn\/dp -
siemens cpu_1518f-4_pn\/dp_firmware *
siemens cpu_1518f-4_pn\/dp -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0CA891A-C3C9-4F61-9A8C-B3EF6B6ACCDD",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6150A06A-0EB8-46CC-A118-2E70BF183CFE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7608E053-65DC-443C-BB69-13CC4788CBEA",
              "versionEndExcluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F33CBC2-330D-4791-9BAB-ECEF3720BBC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1515sp_pc2_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "25352E66-1B7E-4FA3-B56D-FED1E5AC1B1A",
              "versionEndExcluding": "21.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1515sp_pc2_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE1F1B14-C5F6-463C-9DD8-70401123683B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7_plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A8F8195-DFED-4F42-B7DB-85F0F9A53719",
              "versionEndExcluding": "4.0",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7_plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "442B86FA-A38B-47B4-BAE3-AB413A8DC99C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2766CB-A0CE-4552-8ED0-4C4C0732054A",
              "versionEndExcluding": "21.9",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "49EC5FC9-5802-48B6-BDE7-150D80F19A0F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1211c_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "E64F90D8-87A8-4CF5-85E7-771C3A299B7C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "172D341B-D863-4C24-9B6E-633EBE87C8C9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1212c_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D2D5DF-1817-474C-A700-03F17465A4A3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B475E4F-EE4F-4435-9F0B-8E4FA35377BE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1212fc_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6A4E372-E01C-4D0C-AB6F-4BEF2DEB847C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1402D624-5AF3-4E25-A2B0-9D9F214EE8FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1214fc_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FA5E2C9-7A1D-49DE-A749-C77D56CD3D5A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A988C9F-60DF-4BC5-A890-F03F445DD9BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1214c_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "46A01D94-2FE7-4A2D-8827-EC419C0C90C1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F714315-8BEB-4BD3-BE59-C6649A0A105E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1215fc_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "7716828B-440F-4BE4-8DD6-28513E89F1E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BAF22AB6-6DAA-4983-99DB-4F2A2E76856F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1215c_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F05CEC7-E004-4261-A553-7FB3BFF5A8A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C90820D3-3F3E-4DC4-9DCE-A498CC26268D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1217c_firmware:4.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "5893F8F5-24A7-4EBD-85B5-B98443883CEB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C95F12D-563A-4915-9F26-A461EB4F8FA1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1510sp_f-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "10E2C1FE-309C-43EE-B7B7-BD757D9EF688",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1510sp_f-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "17D47104-34D6-4901-BB41-015F393F33E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D89E66-BC93-4BD4-9B93-135600F8D7F6",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6469A423-1EAF-4B51-9083-FB6BF76131C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D89E66-BC93-4BD4-9B93-135600F8D7F6",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6469A423-1EAF-4B51-9083-FB6BF76131C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "236392E7-D009-46FD-99B4-BDEFE6CEACAA",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3231D8E3-D367-4224-BF9E-D547B99C349D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1512sp-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F1EE812-5343-47DC-8C23-C3CFA38D7D8F",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1512sp-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B7D3CDB-E783-4B0A-B326-26BB06DD51F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1512sp_f-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8296B4FE-4394-4A83-9BC9-EC28B06B7991",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1512sp_f-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C37C7DE-C0F9-4CAB-B129-489E720F12A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CBE2EBD-72DD-40D1-BFA8-AAF578E512F9",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1ADE6CA7-7F84-419F-B942-20857402A131",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CBE2EBD-72DD-40D1-BFA8-AAF578E512F9",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1ADE6CA7-7F84-419F-B942-20857402A131",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3175E6AF-D2A6-406B-99CA-10937EAD1BFD",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3985C16-08DE-463D-B352-454673613BEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "949C355A-52AC-4E0B-B721-C4F3FEE1CBBB",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D41186C9-E730-435C-B9A5-F90ADE4C5CAE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "949C355A-52AC-4E0B-B721-C4F3FEE1CBBB",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D41186C9-E730-435C-B9A5-F90ADE4C5CAE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu-1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0544DDE-6523-4ED1-BC54-D88D31BB141F",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu-1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E37DBA8-0842-4271-B3AE-FE884E38938A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "340AA4FB-2EB5-4E4C-BCAA-DB17F47C2B3E",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E71D86D1-F007-4B89-BBCA-246C387BE6A0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9CB34E2-B41A-48AC-B97F-C9F9999CE0FB",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DDF7F78-E67A-4D26-8E98-93F0F759D4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1510sp-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDB385BA-6824-4B6A-AD06-BE1720D878D0",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1510sp-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF05811C-36D7-4C68-8CAD-79A8A370E49B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu1510sp_f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0F759CF-4B0E-44E2-9FED-62EACD40FA7C",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu1510sp_f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F93E2391-2433-4D42-B320-38F3EC211514",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1511-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "98A393E7-C39B-4ABF-B1F1-4811AF861214",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1511-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "562DBC23-9FFD-4427-90A5-D8747E3FE9CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1511-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "98A393E7-C39B-4ABF-B1F1-4811AF861214",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1511-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "562DBC23-9FFD-4427-90A5-D8747E3FE9CE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1511c-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDAC86E1-2DE7-441D-805A-65401BEFD9BA",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1511c-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3895DBD-B615-449D-9339-D52848B5B416",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1511f-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7271B3C5-5D82-4164-8974-56BE34929752",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1511f-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A70BDF8-5FDB-4AFE-B598-CB11B11A5839",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1511t-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A69A3171-3CB9-4C25-B6D2-D6B9B0884243",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1511t-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "935B4436-0896-433F-8D4B-AEAF65055D24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1511tf-1pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BB5F138-14D8-41A3-AAD2-C2327CD044F9",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1511tf-1pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C8E0FD8-5FB7-4230-A7B9-B3B716BB190D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1512c-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D58B1C7-F35C-441D-B287-72D86F496977",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1512c-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35912967-78E4-46FF-AB85-B4F3B230A149",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1512sp-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "018750E9-D640-4799-84E8-F4E8F672B92A",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1512sp-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93570D33-912F-4865-961D-0D33FBFC0A8E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1512sp_f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3F670D4-A18A-4CB8-8115-D827225F9336",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1512sp_f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8852B2E6-DC4D-4E77-95CC-9EFDBCD5F699",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BE09034-2A3D-4518-95E7-4EC1F6F147FF",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41D428E7-26E3-4E14-853A-7768F0319C73",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14F03B2-2C86-4353-ABF5-18F1AA699128",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D82ABDB8-835A-4F5E-92D9-9C3665D28D35",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1513r-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4649855B-5021-432C-8909-623F703F486D",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1513r-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF327DAF-1FF8-4152-840A-1C49FFA30221",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1513pro_f-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B4A4FE9-94F8-49BB-AA72-CAC160BF1B8F",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1513pro_f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAF54AEA-EA6B-4C04-99F4-8BE928E53DD7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B184D76-82FA-41AB-BD95-01B8CA36BDCB",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A94CE47C-C9CC-4B40-8898-D13BE7711C17",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D30764F4-40F1-4515-9183-AA5DC4BF8986",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A69CEB7D-A021-4F03-BDB6-1E43B96E64DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1515r-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1106CDD9-B67A-47E0-A646-A266E1D4DCB7",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1515r-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "696176E2-37C7-4B45-9A0D-4E7789C00D76",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1515t-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D77B4D47-CBFE-46D6-B616-D84CB59F89E6",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1515t-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BF7505A-A791-4E71-AFFD-41522E829847",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1515tf-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D016E20-8320-4137-972D-0E24A2A7BC2E",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1515tf-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "04E6BAF1-FE0B-4A74-ACC1-0FE1A7B385AD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1516pro_f-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5F39B94-7130-4ACF-AF2B-151618F0A342",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1516pro_f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73A9B384-9953-48DE-A694-DA7846F1F1DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1516pro-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B3129DE-7633-4CB1-A183-C9722EFFE2AD",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1516pro-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB0E08E7-384D-43C4-9416-492B529BFFFB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1EC60B9-FAE8-4C62-9688-6DA0340D964E",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EE183F6-A7FD-4EE4-958A-7E25E6088443",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C73FA056-3900-4B80-8090-881205932E7E",
              "versionEndExcluding": "2.9.2.",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F42FF47-E56D-4CD9-A989-E78D001A13E9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1516t-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C83EBB3-5E82-476B-B171-B0816C748A08",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1516t-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03014438-9CD3-4A98-A831-22E393165159",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1516tf-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19BD6ECC-0DB0-4E08-9F52-ED1E04CFBDDE",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1516tf-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A817E11-95D6-42FD-ADA3-CB0422796B5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1517-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C444654E-A635-4D59-A449-7A81380E5D60",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90E06813-3A20-4EE5-92D9-72B1AA966CFF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1517f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "208F9BBB-F06E-4DF5-83D2-87CC52864AF5",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4CC39EA-FF0E-412B-B120-04321CFE873D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1517t-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7425D60D-8DAA-4C7C-AA66-0B7D62ACFAAE",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1517t-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "41BC7FD0-6AB2-4E93-A021-46C7359BE528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1517tf-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9077FD36-23E0-42BD-98ED-2C9DA009F57D",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1517tf-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3EBEB34-9B3E-4423-82D5-1A412CC84B9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4F9D353-9061-496D-BE78-A56E6FFF76C0",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AE8D939-8B71-443A-A060-597C1BF9BB30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "23BB64D2-93ED-4E31-A10C-B427FC4658BD",
              "versionEndExcluding": "2.9.2",
              "versionStartIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D524AE8-F24C-4A18-AA45-0B6820290211",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (Todas las versiones anteriores a la versi\u00f3n V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V21.9), SIMATIC S7 PLCSIM Advanced (Todas las versiones posteriores a V2 y anteriores a V4), familia SIMATIC S7-1200 CPU (incluyendo las variantes SIPLUS) (Version V4.4), familia SIMATIC S7-1500 CPU (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores a V2.5 y anteriores a V2.9.2), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores a V2.5 y anteriores a V21.9), TIM 1531 IRC (incluyendo las variantes SIPLUS NET) (Version V2.1). Debido a una comprobaci\u00f3n de autorizaci\u00f3n incorrecta en el componente afectado, un atacante podr\u00eda extraer informaci\u00f3n sobre el acceso a las variables del programa del PLC protegidas a trav\u00e9s del puerto 102/tcp de un dispositivo afectado cuando lee varios atributos a la vez"
    }
  ],
  "id": "CVE-2020-28397",
  "lastModified": "2024-11-21T05:22:43.247",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-08-10T11:15:07.423",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-863"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-863"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2020-7580

Vulnerability from fkie_nvd - Published: 2020-06-10 17:15 - Updated: 2024-11-21 05:37
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_automatic_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A659B687-1038-42F5-B8AC-A394E41D22A8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "17BCC3CD-61D0-416D-A241-D35AF8EE5BF8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13E3BDF0-B691-4A97-A74A-A65EC910480E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_prosave:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB7752CF-D754-4A78-999B-45FE379E03DE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "658E1A3F-29D6-48D2-BCCE-0BCC41AC49F6",
              "versionEndExcluding": "21.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF09D6E-3375-4731-B16D-30B7592EA5FB",
              "versionEndExcluding": "5.6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A3CA33C-AFAB-418F-870F-0236B8E55943",
              "versionEndIncluding": "16",
              "versionStartIncluding": "13",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:-:*:*:*:*:*:*",
              "matchCriteriaId": "851F8474-4568-487D-98FB-47DF7EAEAC3B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81EADA2F-884C-4D72-8489-71025B3EBAEE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "78366D2F-B728-47F6-B539-5FB2D1B0419D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:5.6:sp2_hotfix1:*:*:*:*:*:*",
              "matchCriteriaId": "06A86DA0-BC1F-4306-B02E-ED2FA36BE273",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F39B396-140B-4005-9A61-F984C9FAF742",
              "versionEndExcluding": "7.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*",
              "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "BF8404AB-579E-4C6B-BCA7-E95F2CE24F7D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update10:*:*:*:*:*:*",
              "matchCriteriaId": "88F6B3BF-727F-432E-89D8-37FB7C76FE2B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update11:*:*:*:*:*:*",
              "matchCriteriaId": "62EB588C-CBB4-4B17-9BB5-B14B1FC6BB21",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update12:*:*:*:*:*:*",
              "matchCriteriaId": "AF3F613C-6707-4517-B4B8-530C912B79E6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update13:*:*:*:*:*:*",
              "matchCriteriaId": "590F62CE-9245-4AC9-9FBC-35136E217B0E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "241D5A28-FB22-4C5B-A067-733168E847BF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update3:*:*:*:*:*:*",
              "matchCriteriaId": "A5418F92-84A9-439C-B86C-ED5820697603",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update4:*:*:*:*:*:*",
              "matchCriteriaId": "40631FBD-116B-4589-B77A-6C5A69990F73",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update5:*:*:*:*:*:*",
              "matchCriteriaId": "64B14972-6163-4D44-A9C6-16328E02AC69",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update6:*:*:*:*:*:*",
              "matchCriteriaId": "8929E926-740F-4F17-B52C-4C73914B1818",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update7:*:*:*:*:*:*",
              "matchCriteriaId": "D4F72666-D10A-4EB2-80D3-18B04C101256",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update8:*:*:*:*:*:*",
              "matchCriteriaId": "0E343221-1E1A-4EE7-80AE-AB24E2244BA0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update9:*:*:*:*:*:*",
              "matchCriteriaId": "1BF716D7-0A77-400F-9B43-64FBE3E65735",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "81F9C13C-065C-4E40-BB46-687D791348A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
              "matchCriteriaId": "5CF06E69-0A23-418D-B0EC-574DACBB4DD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
              "matchCriteriaId": "9164EAC1-C416-4F1F-A910-CE84A167A6D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B9ED7EF-EF58-400F-92C9-3D52D8E39783",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.17:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C3F9210-7A1E-4B10-B384-119FD5733A86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C9253AD-BD82-4BB2-84AD-EB1892B60358",
              "versionEndIncluding": "16",
              "versionStartIncluding": "13",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_startdrive:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C11DB09A-74E1-45EF-A162-9C1E91F54C04",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinamics_starter_commissioning_tool:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1976CDDA-F2AF-4C47-804E-2C1DF44FBF41",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_network_management_system:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "52F7076E-12F7-4F62-9804-18598C39D3FF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_one_virtual:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A607E4B7-2F58-4F68-91EB-16874986E92F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_operate:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BAFC5C25-EC3C-4EB6-B5B2-478AE9CEF10F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versi\u00f3n V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versi\u00f3n V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versi\u00f3n V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versi\u00f3n V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versi\u00f3n V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versi\u00f3n V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versi\u00f3n V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versi\u00f3n V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versi\u00f3n V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versi\u00f3n V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versi\u00f3n V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versi\u00f3n V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versi\u00f3n V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versi\u00f3n V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versi\u00f3n V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versi\u00f3n V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versi\u00f3n V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versi\u00f3n V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versi\u00f3n V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versi\u00f3n V6.14). Un componente dentro de la aplicaci\u00f3n afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no est\u00e1 citada"
    }
  ],
  "id": "CVE-2020-7580",
  "lastModified": "2024-11-21T05:37:24.840",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-06-10T17:15:12.347",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-428"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-428"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2019-10943

Vulnerability from fkie_nvd - Published: 2019-08-13 19:15 - Updated: 2024-11-21 04:20
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFA8109D-F938-4FE3-9885-831D2D0FE058",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8AED132-C4CF-4C2E-B826-DFAE745256FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B4A8C4A-8AED-42A4-BF49-C1F9E9A48EBD",
              "versionEndExcluding": "20.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0812843-6B21-4622-8C97-D87162987434",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEBF07D2-1CFB-4769-8F4D-59737D782B9B",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "99C1E616-6A34-4C85-927B-29C53A0BA873",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB22A001-A28B-48D2-93BE-95C3EBD39A8D",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CFDEA0C-BE3D-425B-B5FD-299C93C70CD8",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85BF9FC3-FF9D-4E14-8D3F-A7AA9CC84A48",
              "versionEndExcluding": "2.8.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E18897A5-B757-412B-A28A-E8BD9CA73520",
              "versionEndExcluding": "2.8.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87628F0C-73A3-4169-A58E-18538AD88C8C",
              "versionEndExcluding": "2.8.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D31E1129-2A71-4130-A32B-0E5A437D4C07",
              "versionEndExcluding": "20.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7_plcsim_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB3DDD9-64F2-4A38-A9E8-2D8AA09F403D",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
    },
    {
      "lang": "es",
      "value": "SIPLUS) (Todas las versiones anteriores a V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones posteriores o iguales V20.8), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a V4.4.0), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones variantes SIPLUS) (Todas las versiones posteriores o iguales V4.4.0), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a V2.8.1), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales V2. 8.1), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a V20.8), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales V20.8), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a V3.0), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales V3.0). Un atacante con acceso de red al puerto 102/tcp podr\u00eda modificar potencialmente el programa de usuario en el PLC de manera que el c\u00f3digo en ejecuci\u00f3n sea diferente del c\u00f3digo fuente que est\u00e1 almacenado en el dispositivo. Un atacante debe tener acceso de red a los dispositivos afectados y debe ser capaz de realizar cambios en el programa de usuario. La vulnerabilidad podr\u00eda afectar a la integridad percibida del programa de usuario almacenado en la CPU. Un ingeniero que intente obtener el c\u00f3digo del programa de usuario que se ejecuta en el dispositivo, puede recibir un c\u00f3digo fuente diferente que no se est\u00e1 ejecutando realmente en el dispositivo"
    }
  ],
  "id": "CVE-2019-10943",
  "lastModified": "2024-11-21T04:20:12.313",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-08-13T19:15:15.530",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-353"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-345"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2019-6568

Vulnerability from fkie_nvd - Published: 2019-04-17 14:29 - Updated: 2024-11-21 04:46
Summary
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
Impacted products
Vendor Product Version
siemens cp1604_firmware *
siemens cp1604 -
siemens cp1616_firmware *
siemens cp1616 -
siemens simatic_rf185c_firmware *
siemens simatic_rf185c -
siemens simatic_cp343-1_advanced_firmware *
siemens simatic_cp343-1_advanced -
siemens simatic_cp443-1_firmware *
siemens simatic_cp443-1 -
siemens simatic_cp443-1_advanced_firmware *
siemens simatic_cp443-1_advanced -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware *
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_hmi_comfort_outdoor_panels_firmware *
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels -
siemens simatic_hmi_comfort_panels_firmware *
siemens simatic_hmi_comfort_panels_firmware 15.1
siemens simatic_hmi_comfort_panels -
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f -
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700 -
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f -
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900 -
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f -
siemens simatic_cp443-1_opc_ua *
siemens simatic_ipc_diagmonitor *
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-plcsim_advanced *
siemens simatic_s7-plcsim_advanced 2.0
siemens simatic_s7-plcsim_advanced 2.0
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens simatic_wincc_runtime_advanced 15.1
siemens sitop_manager *
siemens simatic_rf600r_firmware *
siemens simatic_rf600r -
siemens simatic_rf188c_firmware *
siemens simatic_rf188c -
siemens simatic_rf186c_firmware *
siemens simatic_rf186c -
siemens simatic_rf182c_firmware *
siemens simatic_rf182c -
siemens simatic_rf181-eip_firmware *
siemens simatic_rf181-eip -
siemens simatic_s7-1500_firmware *
siemens simatic_s7-1500 -
siemens simatic_s7-300_firmware *
siemens simatic_s7-300 -
siemens simatic_s7-400_pn_firmware *
siemens simatic_s7-400_pn -
siemens simatic_s7-400_pn\/dp_firmware *
siemens simatic_s7-400_pn\/dp -
siemens simatic_teleservice_adapter_ie_advanced_firmware *
siemens simatic_teleservice_adapter_ie_advanced -
siemens simatic_teleservice_adapter_ie_basic_firmware *
siemens simatic_teleservice_adapter_ie_basic -
siemens simatic_teleservice_adapter_ie_standard_firmware *
siemens simatic_teleservice_adapter_ie_standard -
siemens simatic_winac_rtx_firmware *
siemens simatic_winac_rtx_firmware 2010
siemens simatic_winac_rtx -
siemens simocode_pro_v_eip_firmware *
siemens simocode_pro_v_eip -
siemens simocode_pro_v_pn_firmware *
siemens simocode_pro_v_pn -
siemens sinamics_g130_firmware *
siemens sinamics_g130 -
siemens sinamics_g150_firmware *
siemens sinamics_g150 -
siemens sinamics_s120_firmware *
siemens sinamics_s120 -
siemens sinamics_s150_firmware *
siemens sinamics_s150_firmware 5.1
siemens sinamics_s150_firmware 5.1
siemens sinamics_s150_firmware 5.1
siemens sinamics_s150 -
siemens sinamics_s210_firmware *
siemens sinamics_s210_firmware 5.1
siemens sinamics_s210_firmware 5.1
siemens sinamics_s210 -
siemens sitop_psu8600_firmware *
siemens sitop_psu8600 -
siemens sitop_ups1600_firmware *
siemens sitop_ups1600 -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500f_firmware *
siemens simatic_s7-1500f -
siemens simatic_s7-1500s_firmware *
siemens simatic_s7-1500s -
siemens simatic_s7-1500t_firmware *
siemens simatic_s7-1500t -
siemens sinamics_gh150_firmware *
siemens sinamics_gh150_firmware 4.8
siemens sinamics_gh150 -
siemens sinamics_gl150_firmware *
siemens sinamics_gl150_firmware 4.8
siemens sinamics_gl150 -
siemens sinamics_gm150_firmware *
siemens sinamics_gm150_firmware 4.8
siemens sinamics_gm150 -
siemens sinamics_sl150_firmware *
siemens sinamics_sl150_firmware 4.8
siemens sinamics_sl150 -
siemens sinamics_sm120_firmware *
siemens sinamics_sm120_firmware 4.8
siemens sinamics_sm120 -
siemens sinamics_sm150_firmware *
siemens sinamics_sm150_firmware 5.1
siemens sinamics_sm150 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp1604_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E737620D-9D00-4151-B232-7DFB7FD768B3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp1604:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6222006F-09D7-49F7-B8C7-4D94298A8F6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:cp1616_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65FE6F54-1457-4EB6-9273-1D93B3B97386",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:cp1616:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "184365A2-BAD2-4926-ACEE-F71E018D3CE5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69EE2BF6-3846-478F-9AC6-BEF34617F3B5",
              "versionEndExcluding": "1.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp343-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E6601B8-E032-4B39-BF65-F25CF047EB99",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp343-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ACCC0229-E454-4BEF-931A-3CD820500822",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2035A020-F41E-4FC7-A290-9923574D4921",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp443-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB8636E9-A3DA-4DDC-A3FC-B3EAAD07952E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AD15638-8B84-4DA2-9DDC-9A1CA3548E91",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp443-1_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFE94F56-71DB-4837-9818-6827C80DE2BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1873751-81F4-4732-B30F-9F2DEECBC110",
              "versionEndExcluding": "2.1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F36AC571-C958-4CB8-91D9-5417C1812C02",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00361A3C-60E9-4365-BB51-09D7792C441D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7299F88D-8885-4871-93E1-CBEFD3156B15",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "F18EA7BD-47D0-4367-8F18-C89239B201E3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "865FD012-F390-4BB8-B14F-533840B95512",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "5418D916-49A6-4B79-A653-E2C5221DEBE8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_cp443-1_opc_ua:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56396833-12BF-4AE5-8D3E-695652A99DBF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_ipc_diagmonitor:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FD49A39-47D7-473C-9E46-6D9246BC6D04",
              "versionEndExcluding": "5.1.3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "11C0A94D-5506-4A75-99E1-CA9769AF057C",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B66A2A4-5062-45F8-A615-2DA716650909",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "AED3A3AF-EF77-4E58-91AD-BBE01E1DA4A6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:2.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "23039930-E45C-4B0E-883A-E2F9A7502984",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*",
              "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*",
              "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*",
              "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sitop_manager:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2662688E-6975-46C7-939B-25FF4790518D",
              "versionEndExcluding": "1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "16CBED3D-892A-4EC0-BE2E-358040C34304",
              "versionEndExcluding": "3.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFA55275-691D-4269-93E4-C559C89E3FA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "25F96DAA-696D-4EB4-97DF-986C7681700B",
              "versionEndExcluding": "1.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF8FFD1C-8E33-48E9-A884-B80311F8BA4C",
              "versionEndExcluding": "1.1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf182c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0FC4F972-3A3B-421C-8D62-9C5C4D1992CF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf182c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7540DAD9-2AAC-46A9-B1C5-BB1AC4FCE710",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf181-eip_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFA94867-4367-4186-8A4B-44C3CBCCEF7F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf181-eip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E10A0D57-8805-44DB-95E3-1B240ED5ED09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AE766CD-695B-4A12-8BC5-3743D8E3D73E",
              "versionEndExcluding": "2.6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9461CADE-1624-4D1B-8CF2-CF65F75071C0",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A2219FE-2C3F-4948-85D6-3C53AC08722B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "795D0FF9-1D0B-4C74-BEF3-58EAE74DFA0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC917346-94F6-44FD-AC00-AED0CF3CBBD1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F60D816D-85A5-4971-AF2D-666AE0B74E9E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "71DA3D1A-E435-418F-9A13-945B4BA15FC7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80D166A8-1EEC-42F4-8EAB-1747247A7A05",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFA520B6-5177-43E4-87C0-C215F79FE9B4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C887573-8BE8-42CF-B35A-22F9311AC627",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8",
              "versionEndExcluding": "2010",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*",
              "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_pro_v_eip_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A001968-C7FD-4C11-8439-11532B234CC2",
              "versionEndExcluding": "1.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_pro_v_eip:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "50BDA360-0D33-42DC-ADB9-2F69503C2CD8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simocode_pro_v_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "15CB26DA-7CA0-4BD6-A219-01F6E8A6F03F",
              "versionEndExcluding": "2.1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simocode_pro_v_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1779AE78-AC90-48BE-8FF2-CC11E7CA3CB4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "856768D2-C096-4CA7-B26F-E94B005C0D79",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C579C2C7-0402-46B2-A770-C3B7F71D1096",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "126AC93E-A39F-4754-9707-207C9F2F64F4",
              "versionEndExcluding": "5.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "3E8BCCED-BDC6-4785-8705-799836E5024E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "098262CC-4D3B-4E55-83C3-2816403C553B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.1:sp1_hotfix2:*:*:*:*:*:*",
              "matchCriteriaId": "6092F899-9A89-4FA4-BD80-97511DF7CF8F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7269713-6505-41DF-B85B-F729E24A3F5B",
              "versionEndExcluding": "5.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "BEBF14B3-65A0-41E9-B99C-D88548F307CD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s210_firmware:5.1:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "F151297C-3097-483F-98B5-0261BD547421",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s210:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7BFA8FB3-12A9-4D2E-BCFD-C66313521C80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F389808-001E-4650-86B2-00A72D25BCD0",
              "versionEndExcluding": "1.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sitop_ups1600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD39CC96-ABE3-4854-A102-36AFE1F6CB14",
              "versionEndExcluding": "2.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sitop_ups1600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FC1A64E-6A27-4F91-8A13-829E0F7D8E80",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B023E75A-B76D-4FD8-9660-1F233092160F",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9C47A4A-BE81-499A-AB36-491661B88693",
              "versionEndExcluding": "2.6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A255BC06-2776-4111-A525-76B17371B295",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66A446D2-39ED-4635-AAA0-85D977F600FE",
              "versionEndExcluding": "2.6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1752A2A-0034-4E00-AAC6-FA15345D7A41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5238622A-BCAD-4A06-9920-49BECFDDC2A6",
              "versionEndExcluding": "2.6.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "741B2C38-174C-49DF-98D8-F7D6F49D1CE5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E231DE7-8B8D-41A3-A163-CE8EF50AF9D0",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "6D076504-AFE3-4C51-80E5-C5992CA7D511",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FD67D30A-8681-41AE-B248-7E50BA1B9FC8",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "31393A1B-4DBC-476D-875E-463B4B887E1B",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0206F9F2-27C7-4D2F-817B-13F8FA31E547",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC70D596-AA1E-4196-87B0-BECEE6568AA7",
              "versionEndExcluding": "5.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:5.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "1E81CDB5-122F-48D1-B9F1-4C401D46D978",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
    },
    {
      "lang": "es",
      "value": "SIPLUS), paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" - 22\" (incl. variantes SIPLUS), paneles SIMATIC ET 200SP Open Controller CPU 1515SP PC SIPLUS), paneles m\u00f3viles SIMATIC HMI KTP KTP400F, KTP700, KTP700F, KTP900 y KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, familia SIMATIC RF600R, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 y variantes SIPLUS), controlador de software SIMATIC S7-1500, familia de CPUs SIMATIC S7-300 (incluidas las CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incluidas las variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incluidas las variantes SIPLUS) SIPLUS), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP (incl. SIPLUS), SIMOCODE pro V PN (incl. variantes SIPLUS), SINAMICS G130 V4.6 Control Unit, SINAMICS G130 V4.7 Control Unit, SINAMICS G130 V4.7 SP1 Control Unit, SINAMICS G130 V4.8 Control Unit, SINAMICS G130 V5.1 Control Unit, SINAMICS G130 V5. 1 SP1 Unidad de control, SINAMICS G150 V4.6 Unidad de control, SINAMICS G150 V4.7 Unidad de control, SINAMICS G150 V4.7 SP1 Unidad de control, SINAMICS G150 V4.8 Unidad de control, SINAMICS G150 V5. 1 Unidad de control, SINAMICS G150 V5.1 SP1 Unidad de control, SINAMICS GH150 V4.7 (Unidad de control), SINAMICS GH150 V4.8 (Unidad de control), SINAMICS GL150 V4.7 (Unidad de control), SINAMICS GL150 V4. 8 (Unidad de control), SINAMICS GM150 V4.7 (Unidad de control), SINAMICS GM150 V4.8 (Unidad de control), SINAMICS S120 V4.6 Unidad de control (incl. variantes SIPLUS), SINAMICS S120 V4.7 Unidad de control (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V4.7 SP1 (incl. variantes SIPLUS), SINAMICS S120 V4.8 (incl. variantes SIPLUS), SINAMICS S120 V5.1 (incl. variantes SIPLUS) SIPLUS), SINAMICS S120 V5.1 SP1 Unidad de Control (incl. variantes SIPLUS), SINAMICS S150 V4.6 Unidad de Control, SINAMICS S150 V4.7 Unidad de Control, SINAMICS S150 V4.7 SP1 Unidad de Control, SINAMICS S150 V4. 8 Unidad de control, SINAMICS S150 V5.1 Unidad de control, SINAMICS S150 V5.1 SP1 Unidad de control, SINAMICS S210 V5.1 Unidad de control, SINAMICS S210 V5.1 SP1 Unidad de control, SINAMICS SL150 V4. 7 (Unidad de Control), SINAMICS SL150 V4.8 (Unidad de Control), SINAMICS SM120 V4.7 (Unidad de Control), SINAMICS SM120 V4.8 (Unidad de Control), SINAMICS SM150 V4. 8 (unidad de control), SIPLUS NET CP 343-1 Advanced, SIPLUS NET CP 443-1, SIPLUS NET CP 443-1 Advanced, SITOP Manager, SITOP PSU8600, SITOP UPS1600 (incl. variantes SIPLUS), TIM 1531 IRC (incl. variantes SIPLUS NET). El servidor web de los dispositivos afectados contiene una vulnerabilidad que puede conducir a una condici\u00f3n de denegaci\u00f3n de servicio. Un atacante puede provocar una situaci\u00f3n de denegaci\u00f3n de servicio que lleve a reiniciar el servidor web del dispositivo afectado. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo"
    }
  ],
  "id": "CVE-2019-6568",
  "lastModified": "2024-11-21T04:46:42.773",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2019-04-17T14:29:03.683",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2019-6575

Vulnerability from fkie_nvd - Published: 2019-04-17 14:29 - Updated: 2024-11-21 04:46
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
Impacted products
Vendor Product Version
siemens simatic_cp443-1_opc_ua_firmware *
siemens simatic_cp443-1_opc_ua -
siemens simatic_et_200_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200_open_controller_cpu_1515sp_pc2 -
siemens simatic_ipc_diagmonitor_firmware *
siemens simatic_ipc_diagmonitor -
siemens simatic_net_pc_software_firmware *
siemens simatic_net_pc_software -
siemens simatic_rf188c_firmware *
siemens simatic_rf188c -
siemens simatic_rf600r_firmware *
siemens simatic_rf600r -
siemens simatic_s7-1500_firmware *
siemens simatic_s7-1500 -
siemens opc_unified_architecture *
siemens simatic_s7-1500_software_controller *
siemens simatic_wincc_oa *
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_runtime_comfort *
siemens simatic_wincc_runtime_hsp_comfort *
siemens simatic_wincc_runtime_mobile *
siemens sinec-nms *
siemens sinec-nms 1.0
siemens sinema_server *
siemens sinumerik_opc_ua_server *
siemens telecontrol_server_basic *
siemens simatic_s7-1500f_firmware *
siemens simatic_s7-1500f -
siemens simatic_s7-1500s_firmware *
siemens simatic_s7-1500s -
siemens simatic_s7-1500t_firmware *
siemens simatic_s7-1500t -
siemens simatic_hmi_comfort_outdoor_panels_firmware *
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels_firmware 15.1
siemens simatic_hmi_comfort_outdoor_panels -
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp400f -
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900 -
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700f -
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp700 -
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware *
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f_firmware 15.1
siemens simatic_hmi_ktp_mobile_panels_ktp900f -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp443-1_opc_ua_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D0780D2-8892-490E-9C38-6D1516EBCA76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp443-1_opc_ua:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47272AD2-1D05-419E-A6BE-8836DF69FF82",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB5AE88-04E5-467E-85E5-D3C0DDA2B21F",
              "versionEndExcluding": "2.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF0944C4-8FD7-4B00-85B7-6DB430EAA884",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc_diagmonitor_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "91371CD0-EBDF-43C5-A262-A46E1C343716",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc_diagmonitor:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5E06833-4C26-40AC-B6CF-F7D1322462D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_pc_software_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "77022802-113F-42E7-8FBF-C47BB50E8DA7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_pc_software:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7A00F5A-9B28-45FF-8549-290302939DFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf600r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9523EC09-36C9-41E1-A485-C75819A2DB72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf600r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFA55275-691D-4269-93E4-C559C89E3FA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "065D2218-EA10-410E-A49A-C9A259469421",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:opc_unified_architecture:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6230C5B0-2F36-4C94-BA28-D36170952423",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "054D17CD-74AF-473E-A3BC-7B69DFB1C04B",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_oa:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B74D88E-E8D7-4AA9-8B54-CC833E26CEB4",
              "versionEndExcluding": "3.15-p018",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_comfort:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9AE946B-D532-4CEB-B109-C8B951B61E49",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_hsp_comfort:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49D722B2-948B-4F11-AD36-E1378BB40403",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_mobile:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "455411C4-037C-47BF-9BD6-AC7F9C2D30F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec-nms:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED63145-9082-4346-871B-DF0A6F91E7F0",
              "versionEndExcluding": "1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec-nms:1.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "1F6F05DC-0FBA-4D25-A2E6-06D873B3DFAA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C55DA617-6333-40DA-AB7D-EE49A453E143",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E31B88B-E743-4DFD-996B-154F7F48C510",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2ECBEF2-9B1A-49F8-9850-0AF09BF71ED7",
              "versionEndExcluding": "3.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58CCDA0F-F657-4AF8-BE53-A3993C0280B3",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A255BC06-2776-4111-A525-76B17371B295",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3F162D0-998E-4EC9-BA59-D9B47B07EF69",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1752A2A-0034-4E00-AAC6-FA15345D7A41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C47ADAD6-2DDE-49EF-864B-CC9448399E7B",
              "versionEndIncluding": "2.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "741B2C38-174C-49DF-98D8-F7D6F49D1CE5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7299F88D-8885-4871-93E1-CBEFD3156B15",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "F18EA7BD-47D0-4367-8F18-C89239B201E3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "DE71784C-012F-40EC-82E2-3BE8589F00DC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "C5A35FDE-C76F-430E-BD15-373F9F30FED5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "37A6344F-CB58-4CFA-A971-395BFB3FF02B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "E949961E-320A-4E25-A0CA-5EBC7DA0AD9D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "A390DCB7-4511-4931-A34B-BF6A9B84370D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "FF5136A8-130C-4121-A250-B4DE5883239E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "862B1996-202B-42DF-A7DA-D01CD43C4AB3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "7AFD3E4C-7125-4FB5-991F-76A31AD61BD9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "71172F82-C9B6-4DEC-ADCC-F455E72936CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "A8CA985F-3678-46F4-BE2E-BDBCCD1BC0FE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "1A28CC05-0CEA-4221-83CE-4029726F60E0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "5D612CB7-45A0-44AC-BB96-12AFE2B14CE8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "7B0FAB4F-7D95-4FC0-AF59-CCEDC6E22DC3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "5C925AE3-7262-4DDD-803D-D871A66CD2B2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "E64DEED6-7E6F-4E79-BA4D-2B2E43B2B97D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594",
              "versionEndExcluding": "15.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*",
              "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_1:*:*:*:*:*:*",
              "matchCriteriaId": "9429BA23-CB76-4574-B7F8-530882CF704A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_2:*:*:*:*:*:*",
              "matchCriteriaId": "3794C871-098D-428F-89EA-ADDEFD4E4A86",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:upd_3:*:*:*:*:*:*",
              "matchCriteriaId": "386F501D-5C7D-4336-A39D-31B12C5BCB56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 443-1 OPC UA (todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones anteriores a V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026amp; 15\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incluidas las variantes SIPLUS) (todas las versiones anteriores a V15. 1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a V15.1 Upd 4), SIMATIC IPC DiagMonitor (Todas las versiones anteriores a V5.1. 3), SIMATIC NET PC Software V13 (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC RF188C (Todas las versiones anteriores a V1. 1.0), familia SIMATIC RF600R (Todas las versiones anteriores a V3.2.1), familia de CPUs SIMATIC S7-1500 (incluidas las CPUs ET200 relacionadas y las variantes SIPLUS) (Todas las versiones posteriores o iguales a V2.5 anteriores a V2.6.1), SIMATIC S7-1500 Software Controller (Todas las versiones entre V2.5 (incluida) y V2.7 (excluida)), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 15 P018), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V15.1 Upd 4), SINEC NMS (Todas las versiones anteriores a V1.0 SP1), SINEMA Server (Todas las versiones anteriores a V14 SP2), SINUMERIK OPC UA Server (Todas las versiones anteriores a V2.1), TeleControl Server Basic (Todas las versiones anteriores a V3.1.1). Los paquetes de red especialmente dise\u00f1ados que se env\u00edan a los dispositivos afectados en el puerto 4840/tcp podr\u00edan permitir a un atacante remoto no autenticado provocar una condici\u00f3n de denegaci\u00f3n de servicio de la comunicaci\u00f3n OPC o bloquear el dispositivo. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad de la comunicaci\u00f3n OPC"
    }
  ],
  "id": "CVE-2019-6575",
  "lastModified": "2024-11-21T04:46:43.960",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-04-17T14:29:03.760",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-248"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-755"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

CVE-2022-30694 (GCVE-0-2022-30694)

Vulnerability from cvelistv5 – Published: 2022-11-08 00:00 – Updated: 2025-04-21 13:47
VLAI?
Summary
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
CWE
  • CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller CPU 1504D TF Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC Drive Controller CPU 1507D TF Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V21.9.7
Create a notification for this product.
    Siemens SIMATIC PC Station Affected: All versions >= V2.1
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions < V4.6.0
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511T-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511TF-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513R-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515-2 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515F-2 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515R-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515T-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515TF-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517H-3 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518HF-4 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller V2 Affected: All versions < V21.9.7
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V5.0
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V17 Update 5
Create a notification for this product.
    Siemens SINUMERIK ONE Affected: All versions < V6.22
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515R-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1517H-3 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518HF-4 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:56:13.567Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-30694",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:15:21.439962Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:47:33.635Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1504D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1507D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PC Station",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK ONE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352: Cross-Site Request Forgery (CSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:31:58.151Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-30694",
    "datePublished": "2022-11-08T00:00:00.000Z",
    "dateReserved": "2022-05-13T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:47:33.635Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38465 (GCVE-0-2022-38465)

Vulnerability from cvelistv5 – Published: 2022-10-11 00:00 – Updated: 2025-04-21 13:48
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.
CWE
  • CWE-522 - Insufficiently Protected Credentials
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.739Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38465",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:22:47.312699Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:48:21.222Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK MC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.21"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK ONE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.21"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINUMERIK MC (All versions \u003c V6.21), SINUMERIK ONE (All versions \u003c V6.21). Affected products  protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.\r\n\r\nThis could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522: Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-15T09:24:47.442Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-38465",
    "datePublished": "2022-10-11T00:00:00.000Z",
    "dateReserved": "2022-08-19T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:48:21.222Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-37205 (GCVE-0-2021-37205)

Vulnerability from cvelistv5 – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:29
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CWE
  • CWE-401 - Missing Release of Memory after Effective Lifetime
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.897Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-37205",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:12:33.320440Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T18:29:47.038Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-401",
              "description": "CWE-401: Missing Release of Memory after Effective Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:55.468Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37205",
    "datePublished": "2022-02-09T15:16:57.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-04-18T18:29:47.038Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-37204 (GCVE-0-2021-37204)

Vulnerability from cvelistv5 – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CWE
  • CWE-672 - Operation on a Resource after Expiration or Release
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller family Affected: All versions < V2.9.2
Create a notification for this product.
    Siemens SIMATIC Drive Controller family Affected: All versions >= V2.9.2 < V2.9.4
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V21.9
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions >= V21.9 < V21.9.4
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions < V4.5.0
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions >= V4.5.0 < V4.5.2
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.9.2
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions >= V2.9.2 < V2.9.4
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V21.9
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions >= V21.9 < V21.9.4
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V4.0
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions >= V4.0 < V4.0 SP1
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: All versions < V2.3.6
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: All versions < V2.3.6
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.812Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-37204",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:12:37.070496Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T18:33:01.575Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-672",
              "description": "CWE-672: Operation on a Resource after Expiration or Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:54.435Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37204",
    "datePublished": "2022-02-09T15:16:56.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-04-18T18:33:01.575Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-37185 (GCVE-0-2021-37185)

Vulnerability from cvelistv5 – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CWE
  • CWE-672 - Operation on a Resource after Expiration or Release
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.183Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-37185",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:12:41.029825Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T18:33:19.110Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-672",
              "description": "CWE-672: Operation on a Resource after Expiration or Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:53.394Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37185",
    "datePublished": "2022-02-09T15:16:44.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-04-18T18:33:19.110Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-28397 (GCVE-0-2020-28397)

Vulnerability from cvelistv5 – Published: 2021-08-10 10:35 – Updated: 2024-08-04 16:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
Severity ?
No CVSS data available.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.119Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "product": "SIMATIC S7 PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e V2 \u003c V4"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Version V4.4"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e V2.5 \u003c V2.9.2"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e V2.5 \u003c V21.9"
            }
          ]
        },
        {
          "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Version V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-14T10:47:15",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-28397",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Drive Controller family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V21.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7 PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e V2 \u003c V4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version V4.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e V2.5 \u003c V2.9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e V2.5 \u003c V21.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version V2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863: Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28397",
    "datePublished": "2021-08-10T10:35:23",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:59.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7580 (GCVE-0-2020-7580)

Vulnerability from cvelistv5 – Published: 2020-06-10 00:00 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Severity ?
No CVSS data available.
CWE
  • CWE-428 - Unquoted Search Path or Element
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC Automation Tool Affected: All versions < V4 SP2
Create a notification for this product.
    Siemens SIMATIC NET PC Software V14 Affected: All versions < V14 SP1 Update 14
Create a notification for this product.
    Siemens SIMATIC NET PC Software V15 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC NET PC Software V16 Affected: All versions < V16 Upd3
Create a notification for this product.
    Siemens SIMATIC PCS neo Affected: All versions < V3.0 SP1
Create a notification for this product.
    Siemens SIMATIC ProSave Affected: All versions < V17
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V21.8
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V13 Affected: All versions < V13 SP2 Update 4
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V14 Affected: All versions < V14 SP1 Update 10
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V15 Affected: All versions < V15.1 Update 5
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V16 Affected: All versions < V16 Update 2
Create a notification for this product.
    Siemens SIMATIC STEP 7 V5 Affected: All versions < V5.6 SP2 HF3
Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.16 Affected: All versions < V3.16 P018
Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.17 Affected: All versions < V3.17 P003
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V16 Update 2
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V13 Affected: All versions < V13 SP2 Update 4
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V14 Affected: All versions < V14 SP1 Update 10
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V15 Affected: All versions < V15.1 Update 5
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V16 Affected: All versions < V16 Update 2
Create a notification for this product.
    Siemens SIMATIC WinCC V7.4 Affected: All versions < V7.4 SP1 Update 14
Create a notification for this product.
    Siemens SIMATIC WinCC V7.5 Affected: All versions < V7.5 SP1 Update 3
Create a notification for this product.
    Siemens SINAMICS STARTER Affected: All Versions < V5.4 HF2
Create a notification for this product.
    Siemens SINAMICS Startdrive Affected: All Versions < V16 Update 3
Create a notification for this product.
    Siemens SINEC NMS Affected: All versions < V1.0 SP2
Create a notification for this product.
    Siemens SINEMA Server Affected: All versions < V14 SP3
Create a notification for this product.
    Siemens SINUMERIK ONE virtual Affected: All Versions < V6.14
Create a notification for this product.
    Siemens SINUMERIK Operate Affected: All Versions < V6.14
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.492Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Upd3"
            }
          ]
        },
        {
          "product": "SIMATIC PCS neo",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC ProSave",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.8"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.16 P018"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.17 P003"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP1 Update 3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.4 HF2"
            }
          ]
        },
        {
          "product": "SINAMICS Startdrive",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V16 Update 3"
            }
          ]
        },
        {
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0 SP2"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP3"
            }
          ]
        },
        {
          "product": "SINUMERIK ONE virtual",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        },
        {
          "product": "SINUMERIK Operate",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428: Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-7580",
    "datePublished": "2020-06-10T00:00:00",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10943 (GCVE-0-2019-10943)

Vulnerability from cvelistv5 – Published: 2019-08-13 18:55 – Updated: 2024-08-04 22:40
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
Severity ?
No CVSS data available.
CWE
  • CWE-353 - Missing Support for Integrity Check
Assigner
References
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller family Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V20.8
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions >= V20.8
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions < V4.4.0
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions >= V4.4.0
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.8.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions >= V2.8.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V20.8
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions >= V20.8
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V3.0
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions >= V3.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.602Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.4.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.8.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353: Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:16:23",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10943",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Drive Controller family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V4.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.8.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-353: Missing Support for Integrity Check"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10943",
    "datePublished": "2019-08-13T18:55:57",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.602Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6568 (GCVE-0-2019-6568)

Vulnerability from cvelistv5 – Published: 2019-04-17 13:40 – Updated: 2024-08-04 20:23
VLAI?
Summary
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1604 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC CP 1616 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC CP 343-1 Advanced Affected: All versions
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIMATIC CP 443-1 OPC UA Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Affected: All versions < V2.1.6
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V2.7
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMATIC IPC DiagMonitor Affected: All versions < V5.1.3
Create a notification for this product.
    Siemens SIMATIC RF182C Affected: All versions
Create a notification for this product.
    Siemens SIMATIC RF185C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF186C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF188C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF600R family Affected: All versions < V3.2.1
Create a notification for this product.
    Siemens SIMATIC RFID 181EIP Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.6.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V2.7
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V2.0 SP1 UPD1
Create a notification for this product.
    Siemens SIMATIC Teleservice Adapter IE Advanced Affected: All versions
Create a notification for this product.
    Siemens SIMATIC Teleservice Adapter IE Basic Affected: All versions
Create a notification for this product.
    Siemens SIMATIC Teleservice Adapter IE Standard Affected: All versions
Create a notification for this product.
    Siemens SIMATIC WinAC RTX 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
    Siemens SIMATIC WinAC RTX F 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) Affected: All versions < V1.1.3
Create a notification for this product.
    Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Affected: All versions < V2.1.3
Create a notification for this product.
    Siemens SINAMICS G130 V4.6 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V4.7 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V4.7 SP1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V4.8 Control Unit Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS G130 V5.1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V5.1 SP1 Control Unit Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS G150 V4.6 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V4.7 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V4.7 SP1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V4.8 Control Unit Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS G150 V5.1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V5.1 SP1 Control Unit Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS GH150 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS GH150 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF9
Create a notification for this product.
    Siemens SINAMICS GL150 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS GL150 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF9
Create a notification for this product.
    Siemens SINAMICS GM150 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS GM150 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF9
Create a notification for this product.
    Siemens SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants) Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants) Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS S150 V4.6 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V4.7 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V4.7 SP1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V4.8 Control Unit Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS S150 V5.1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V5.1 SP1 Control Unit Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS S210 Affected: All versions < V5.1 SP1 HF8
Create a notification for this product.
    Siemens SINAMICS SL150 V4.7 (Control Unit) Affected: All versions < V4.7 HF33
Create a notification for this product.
    Siemens SINAMICS SL150 V4.8 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS SM120 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS SM120 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF10
Create a notification for this product.
    Siemens SINAMICS SM150 V4.8 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS NET CP 343-1 Advanced Affected: All versions
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SITOP Manager Affected: All versions < V1.1
Create a notification for this product.
    Siemens SITOP PSU8600 Affected: All versions < V1.5
Create a notification for this product.
    Siemens SITOP UPS1600 (incl. SIPLUS variants) Affected: All versions < V2.3
Create a notification for this product.
    Siemens TIM 1531 IRC (incl. SIPLUS NET variants) Affected: All versions < V2.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.207Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF182C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF185C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF186C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF188C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RFID 181EIP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0 SP1 UPD1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S210",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF33"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP Manager",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:03.049Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6568",
    "datePublished": "2019-04-17T13:40:24",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6575 (GCVE-0-2019-6575)

Vulnerability from cvelistv5 – Published: 2019-04-17 13:40 – Updated: 2024-08-04 20:23
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
Siemens SIMATIC CP 443-1 OPC UA Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V2.7
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SIMATIC IPC DiagMonitor Affected: All versions < V5.1.3
Create a notification for this product.
    Siemens SIMATIC NET PC Software V13 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC NET PC Software V14 Affected: All versions < V14 SP1 Update 14
Create a notification for this product.
    Siemens SIMATIC NET PC Software V15 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC RF188C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF600R family Affected: All versions < V3.2.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions >= V2.5 < V2.6.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions between V2.5 (including) and V2.7 (excluding)
Create a notification for this product.
    Siemens SIMATIC WinCC OA Affected: All versions < V3.15 P018
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SINEC NMS Affected: All versions < V1.0 SP1
Create a notification for this product.
    Siemens SINEMA Server Affected: All versions < V14 SP2
Create a notification for this product.
    Siemens SINUMERIK OPC UA Server Affected: All versions < V2.1
Create a notification for this product.
    Siemens TeleControl Server Basic Affected: All versions < V3.1.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.041Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1.3"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC RF188C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.5 \u003c V2.6.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions between V2.5 (including) and V2.7 (excluding)"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.15 P018"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0 SP1"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP2"
            }
          ]
        },
        {
          "product": "SINUMERIK OPC UA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:16:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-6575",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC CP 443-1 OPC UA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC IPC DiagMonitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Update 14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RF188C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RF600R family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.2.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.5 \u003c V2.6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions between V2.5 (including) and V2.7 (excluding)"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC OA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.15 P018"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINEC NMS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.0 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINEMA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINUMERIK OPC UA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TeleControl Server Basic",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6575",
    "datePublished": "2019-04-17T13:40:24",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-30694 (GCVE-0-2022-30694)

Vulnerability from nvd – Published: 2022-11-08 00:00 – Updated: 2025-04-21 13:47
VLAI?
Summary
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
CWE
  • CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller CPU 1504D TF Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC Drive Controller CPU 1507D TF Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V21.9.7
Create a notification for this product.
    Siemens SIMATIC PC Station Affected: All versions >= V2.1
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions < V4.6.0
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511T-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1511TF-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512C-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1513R-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515-2 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515F-2 PN Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515R-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515T-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1515TF-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517H-3 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518HF-4 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller V2 Affected: All versions < V21.9.7
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V5.0
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V17 Update 5
Create a notification for this product.
    Siemens SINUMERIK ONE Affected: All versions < V6.22
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1511F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513F-1 PN Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1513F-1 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515R-2 PN Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Affected: All versions
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Affected: All versions < V2.9.7
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1517H-3 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-1500 CPU 1518HF-4 PN Affected: All versions < V3.0.1
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.19
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:56:13.567Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-30694",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:15:21.439962Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:47:33.635Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1504D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1507D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PC Station",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK ONE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352: Cross-Site Request Forgery (CSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:31:58.151Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-30694",
    "datePublished": "2022-11-08T00:00:00.000Z",
    "dateReserved": "2022-05-13T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:47:33.635Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-38465 (GCVE-0-2022-38465)

Vulnerability from nvd – Published: 2022-10-11 00:00 – Updated: 2025-04-21 13:48
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication.
CWE
  • CWE-522 - Insufficiently Protected Credentials
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:54:03.739Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-38465",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:22:47.312699Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:48:21.222Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK MC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.21"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK ONE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.21"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SINUMERIK MC (All versions \u003c V6.21), SINUMERIK ONE (All versions \u003c V6.21). Affected products  protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.\r\n\r\nThis could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522: Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-02-15T09:24:47.442Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568427.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-568428.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-38465",
    "datePublished": "2022-10-11T00:00:00.000Z",
    "dateReserved": "2022-08-19T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:48:21.222Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-37205 (GCVE-0-2021-37205)

Vulnerability from nvd – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:29
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CWE
  • CWE-401 - Missing Release of Memory after Effective Lifetime
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.897Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-37205",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:12:33.320440Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T18:29:47.038Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-401",
              "description": "CWE-401: Missing Release of Memory after Effective Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:55.468Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37205",
    "datePublished": "2022-02-09T15:16:57.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-04-18T18:29:47.038Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-37204 (GCVE-0-2021-37204)

Vulnerability from nvd – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CWE
  • CWE-672 - Operation on a Resource after Expiration or Release
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller family Affected: All versions < V2.9.2
Create a notification for this product.
    Siemens SIMATIC Drive Controller family Affected: All versions >= V2.9.2 < V2.9.4
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V21.9
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions >= V21.9 < V21.9.4
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions < V4.5.0
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions >= V4.5.0 < V4.5.2
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.9.2
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions >= V2.9.2 < V2.9.4
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V21.9
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions >= V21.9 < V21.9.4
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V4.0
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions >= V4.0 < V4.0 SP1
Create a notification for this product.
    Siemens SIPLUS TIM 1531 IRC Affected: All versions < V2.3.6
Create a notification for this product.
    Siemens TIM 1531 IRC Affected: All versions < V2.3.6
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.812Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-37204",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:12:37.070496Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T18:33:01.575Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-672",
              "description": "CWE-672: Operation on a Resource after Expiration or Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:54.435Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37204",
    "datePublished": "2022-02-09T15:16:56.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-04-18T18:33:01.575Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-37185 (GCVE-0-2021-37185)

Vulnerability from nvd – Published: 2022-02-09 15:16 – Updated: 2025-04-18 18:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
CWE
  • CWE-672 - Operation on a Resource after Expiration or Release
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.183Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-37185",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:12:41.029825Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-18T18:33:19.110Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-672",
              "description": "CWE-672: Operation on a Resource after Expiration or Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:53.394Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37185",
    "datePublished": "2022-02-09T15:16:44.000Z",
    "dateReserved": "2021-07-21T00:00:00.000Z",
    "dateUpdated": "2025-04-18T18:33:19.110Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-28397 (GCVE-0-2020-28397)

Vulnerability from nvd – Published: 2021-08-10 10:35 – Updated: 2024-08-04 16:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.
Severity ?
No CVSS data available.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.119Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "product": "SIMATIC S7 PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e V2 \u003c V4"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Version V4.4"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e V2.5 \u003c V2.9.2"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e V2.5 \u003c V21.9"
            }
          ]
        },
        {
          "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "Version V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863: Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-14T10:47:15",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-28397",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Drive Controller family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V21.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7 PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e V2 \u003c V4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version V4.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e V2.5 \u003c V2.9.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e V2.5 \u003c V21.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version V2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC S7 PLCSIM Advanced (All versions \u003e V2 \u003c V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e V2.5 \u003c V2.9.2), SIMATIC S7-1500 Software Controller (All versions \u003e V2.5 \u003c V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-863: Incorrect Authorization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865327.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28397",
    "datePublished": "2021-08-10T10:35:23",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:59.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7580 (GCVE-0-2020-7580)

Vulnerability from nvd – Published: 2020-06-10 00:00 – Updated: 2024-08-04 09:33
VLAI?
Summary
A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges.
Severity ?
No CVSS data available.
CWE
  • CWE-428 - Unquoted Search Path or Element
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC Automation Tool Affected: All versions < V4 SP2
Create a notification for this product.
    Siemens SIMATIC NET PC Software V14 Affected: All versions < V14 SP1 Update 14
Create a notification for this product.
    Siemens SIMATIC NET PC Software V15 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC NET PC Software V16 Affected: All versions < V16 Upd3
Create a notification for this product.
    Siemens SIMATIC PCS neo Affected: All versions < V3.0 SP1
Create a notification for this product.
    Siemens SIMATIC ProSave Affected: All versions < V17
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V21.8
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V13 Affected: All versions < V13 SP2 Update 4
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V14 Affected: All versions < V14 SP1 Update 10
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V15 Affected: All versions < V15.1 Update 5
Create a notification for this product.
    Siemens SIMATIC STEP 7 (TIA Portal) V16 Affected: All versions < V16 Update 2
Create a notification for this product.
    Siemens SIMATIC STEP 7 V5 Affected: All versions < V5.6 SP2 HF3
Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.16 Affected: All versions < V3.16 P018
Create a notification for this product.
    Siemens SIMATIC WinCC OA V3.17 Affected: All versions < V3.17 P003
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V16 Update 2
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V13 Affected: All versions < V13 SP2 Update 4
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V14 Affected: All versions < V14 SP1 Update 10
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V15 Affected: All versions < V15.1 Update 5
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V16 Affected: All versions < V16 Update 2
Create a notification for this product.
    Siemens SIMATIC WinCC V7.4 Affected: All versions < V7.4 SP1 Update 14
Create a notification for this product.
    Siemens SIMATIC WinCC V7.5 Affected: All versions < V7.5 SP1 Update 3
Create a notification for this product.
    Siemens SINAMICS STARTER Affected: All Versions < V5.4 HF2
Create a notification for this product.
    Siemens SINAMICS Startdrive Affected: All Versions < V16 Update 3
Create a notification for this product.
    Siemens SINEC NMS Affected: All versions < V1.0 SP2
Create a notification for this product.
    Siemens SINEMA Server Affected: All versions < V14 SP3
Create a notification for this product.
    Siemens SINUMERIK ONE virtual Affected: All Versions < V6.14
Create a notification for this product.
    Siemens SINUMERIK Operate Affected: All Versions < V6.14
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.492Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4 SP2"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Upd3"
            }
          ]
        },
        {
          "product": "SIMATIC PCS neo",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0 SP1"
            }
          ]
        },
        {
          "product": "SIMATIC ProSave",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.8"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 V5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.6 SP2 HF3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.16 P018"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA V3.17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.17 P003"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V13 SP2 Update 4"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 10"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 2"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 SP1 Update 3"
            }
          ]
        },
        {
          "product": "SINAMICS STARTER",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V5.4 HF2"
            }
          ]
        },
        {
          "product": "SINAMICS Startdrive",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V16 Update 3"
            }
          ]
        },
        {
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0 SP2"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP3"
            }
          ]
        },
        {
          "product": "SINUMERIK ONE virtual",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        },
        {
          "product": "SINUMERIK Operate",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c V6.14"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-428",
              "description": "CWE-428: Unquoted Search Path or Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-7580",
    "datePublished": "2020-06-10T00:00:00",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.492Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10943 (GCVE-0-2019-10943)

Vulnerability from nvd – Published: 2019-08-13 18:55 – Updated: 2024-08-04 22:40
VLAI?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
Severity ?
No CVSS data available.
CWE
  • CWE-353 - Missing Support for Integrity Check
Assigner
References
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller family Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V20.8
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions >= V20.8
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions < V4.4.0
Create a notification for this product.
    Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions >= V4.4.0
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.8.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions >= V2.8.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V20.8
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions >= V20.8
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V3.0
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions >= V3.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.602Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.4.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.8.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353: Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:16:23",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10943",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Drive Controller family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V4.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.8.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-353: Missing Support for Integrity Check"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10943",
    "datePublished": "2019-08-13T18:55:57",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.602Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6568 (GCVE-0-2019-6568)

Vulnerability from nvd – Published: 2019-04-17 13:40 – Updated: 2024-08-04 20:23
VLAI?
Summary
The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.
CWE
Assigner
Impacted products
Vendor Product Version
Siemens SIMATIC CP 1604 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC CP 1616 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC CP 343-1 Advanced Affected: All versions
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIMATIC CP 443-1 Advanced Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIMATIC CP 443-1 OPC UA Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Affected: All versions < V2.1.6
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V2.7
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMATIC IPC DiagMonitor Affected: All versions < V5.1.3
Create a notification for this product.
    Siemens SIMATIC RF182C Affected: All versions
Create a notification for this product.
    Siemens SIMATIC RF185C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF186C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF188C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF600R family Affected: All versions < V3.2.1
Create a notification for this product.
    Siemens SIMATIC RFID 181EIP Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.6.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V2.7
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: All versions < V2.0 SP1 UPD1
Create a notification for this product.
    Siemens SIMATIC Teleservice Adapter IE Advanced Affected: All versions
Create a notification for this product.
    Siemens SIMATIC Teleservice Adapter IE Basic Affected: All versions
Create a notification for this product.
    Siemens SIMATIC Teleservice Adapter IE Standard Affected: All versions
Create a notification for this product.
    Siemens SIMATIC WinAC RTX 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
    Siemens SIMATIC WinAC RTX F 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V15.1 Upd4
Create a notification for this product.
    Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) Affected: All versions < V1.1.3
Create a notification for this product.
    Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Affected: All versions < V2.1.3
Create a notification for this product.
    Siemens SINAMICS G130 V4.6 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V4.7 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V4.7 SP1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V4.8 Control Unit Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS G130 V5.1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G130 V5.1 SP1 Control Unit Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS G150 V4.6 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V4.7 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V4.7 SP1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V4.8 Control Unit Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS G150 V5.1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS G150 V5.1 SP1 Control Unit Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS GH150 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS GH150 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF9
Create a notification for this product.
    Siemens SINAMICS GL150 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS GL150 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF9
Create a notification for this product.
    Siemens SINAMICS GM150 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS GM150 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF9
Create a notification for this product.
    Siemens SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants) Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants) Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS S150 V4.6 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V4.7 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V4.7 SP1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V4.8 Control Unit Affected: All versions < V4.8 HF6
Create a notification for this product.
    Siemens SINAMICS S150 V5.1 Control Unit Affected: All versions
Create a notification for this product.
    Siemens SINAMICS S150 V5.1 SP1 Control Unit Affected: All versions < V5.1 SP1 HF4
Create a notification for this product.
    Siemens SINAMICS S210 Affected: All versions < V5.1 SP1 HF8
Create a notification for this product.
    Siemens SINAMICS SL150 V4.7 (Control Unit) Affected: All versions < V4.7 HF33
Create a notification for this product.
    Siemens SINAMICS SL150 V4.8 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS SM120 V4.7 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SINAMICS SM120 V4.8 (Control Unit) Affected: All versions < V4.8 SP2 HF10
Create a notification for this product.
    Siemens SINAMICS SM150 V4.8 (Control Unit) Affected: All versions
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8 PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS ET 200S IM151-8F PN/DP CPU Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS NET CP 343-1 Advanced Affected: All versions
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIPLUS NET CP 443-1 Advanced Affected: All versions < V3.3
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Affected: All versions < V3.3.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Affected: All versions < V3.2.16
Create a notification for this product.
    Siemens SITOP Manager Affected: All versions < V1.1
Create a notification for this product.
    Siemens SITOP PSU8600 Affected: All versions < V1.5
Create a notification for this product.
    Siemens SITOP UPS1600 (incl. SIPLUS variants) Affected: All versions < V2.3
Create a notification for this product.
    Siemens TIM 1531 IRC (incl. SIPLUS NET variants) Affected: All versions < V2.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.207Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF182C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF185C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF186C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF188C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RFID 181EIP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0 SP1 UPD1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.6 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V5.1 SP1 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S210",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1 SP1 HF8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF33"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP2 HF10"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM150 V4.8 (Control Unit)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 343-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET CP 443-1 Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.16"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP Manager",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device.\r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125: Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-05-09T11:51:03.049Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6568",
    "datePublished": "2019-04-17T13:40:24",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6575 (GCVE-0-2019-6575)

Vulnerability from nvd – Published: 2019-04-17 13:40 – Updated: 2024-08-04 20:23
VLAI?
Summary
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.
Severity ?
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
Siemens SIMATIC CP 443-1 OPC UA Affected: All versions
Create a notification for this product.
    Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Affected: All versions < V2.7
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SIMATIC IPC DiagMonitor Affected: All versions < V5.1.3
Create a notification for this product.
    Siemens SIMATIC NET PC Software V13 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC NET PC Software V14 Affected: All versions < V14 SP1 Update 14
Create a notification for this product.
    Siemens SIMATIC NET PC Software V15 Affected: All versions
Create a notification for this product.
    Siemens SIMATIC RF188C Affected: All versions < V1.1.0
Create a notification for this product.
    Siemens SIMATIC RF600R family Affected: All versions < V3.2.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions >= V2.5 < V2.6.1
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller Affected: All versions between V2.5 (including) and V2.7 (excluding)
Create a notification for this product.
    Siemens SIMATIC WinCC OA Affected: All versions < V3.15 P018
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: All versions < V15.1 Upd 4
Create a notification for this product.
    Siemens SINEC NMS Affected: All versions < V1.0 SP1
Create a notification for this product.
    Siemens SINEMA Server Affected: All versions < V14 SP2
Create a notification for this product.
    Siemens SINUMERIK OPC UA Server Affected: All versions < V2.1
Create a notification for this product.
    Siemens TeleControl Server Basic Affected: All versions < V3.1.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:22.041Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SIMATIC IPC DiagMonitor",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.1.3"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V13",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC RF188C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "product": "SIMATIC RF600R family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.5 \u003c V2.6.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions between V2.5 (including) and V2.7 (excluding)"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.15 P018"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 4"
            }
          ]
        },
        {
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0 SP1"
            }
          ]
        },
        {
          "product": "SINEMA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP2"
            }
          ]
        },
        {
          "product": "SINUMERIK OPC UA Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "product": "TeleControl Server Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:16:36",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-6575",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC CP 443-1 OPC UA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.7"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC IPC DiagMonitor",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V5.1.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Update 14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RF188C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.1.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RF600R family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.2.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.5 \u003c V2.6.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions between V2.5 (including) and V2.7 (excluding)"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC OA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.15 P018"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINEC NMS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.0 SP1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINEMA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SINUMERIK OPC UA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TeleControl Server Basic",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.1.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-6575",
    "datePublished": "2019-04-17T13:40:24",
    "dateReserved": "2019-01-22T00:00:00",
    "dateUpdated": "2024-08-04T20:23:22.041Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}