Search criteria

3 vulnerabilities found for wiser_link_firmware by schneider-electric

FKIE_CVE-2020-7548

Vulnerability from fkie_nvd - Published: 2020-12-01 15:15 - Updated: 2024-11-21 05:37

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:acti9_smartlink_si_d_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "53A4A356-8F64-4D1C-8CCB-28803D59BB5B",
              "versionEndExcluding": "002.004.002",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:acti9_smartlink_si_d:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2CA2A7D-C3AB-49BE-B4B8-61177D64B2C8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:acti9_smartlink_si_b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B72CD29E-2E3E-4E96-A614-355AC1BF348B",
              "versionEndExcluding": "002.004.002",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:acti9_smartlink_si_b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB18AC59-6752-410B-987F-428D074C9B6A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:acti9_powertag_link_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED821AB9-402E-47E0-9ACB-C7E97653AF28",
              "versionEndExcluding": "001.008.007",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:acti9_powertag_link:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "572B9253-6A4A-456B-B052-A9FB97578BC8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:acti9_powertag_link_hd_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D5E8701-CC1C-423D-BC5F-CB9E586F784A",
              "versionEndExcluding": "001.008.007",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:acti9_powertag_link_hd:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "383B1CB5-BEE7-4387-9B42-925F9F9CC345",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:acti9_smartlink_el_b_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "424EBA8F-CCF4-49A2-8128-94C0D40C50AE",
              "versionEndExcluding": "1.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:acti9_smartlink_el_b:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C7D7CC7-F949-4EC4-BCA7-B52CD9FF2524",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_link_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "15224AF4-3090-45CA-9149-0A7C00E4F917",
              "versionEndExcluding": "1.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_link:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "808ED268-575E-49A1-9F0A-C68ADC677A1F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:wiser_energy_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "89706F01-2369-4941-B0FA-793B8D828023",
              "versionEndExcluding": "1.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:wiser_energy:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "84DAFA0A-0CBF-46B2-BB91-2BD44DF23040",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login."
    },
    {
      "lang": "es",
      "value": "Una CWE-330: Se presenta una vulnerabilidad uso de Valores Insuficientemente Aleatorios en Gateways Serie Smartlink, PowerTag y Wiser (v\u00e9ase la notificaci\u00f3n de seguridad para la informaci\u00f3n de la versi\u00f3n) que podr\u00eda permitir a usuarios no autorizados iniciar sesi\u00f3n"
    }
  ],
  "id": "CVE-2020-7548",
  "lastModified": "2024-11-21T05:37:21.567",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-12-01T15:15:12.720",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-330"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Secondary"
    }
  ]
}

CVE-2020-7548 (GCVE-0-2020-7548)

Vulnerability from cvelistv5 – Published: 2020-12-01 14:45 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.
Severity ?
No CVSS data available.
CWE
  • CWE-330 - - Use of Insufficiently Random Values
Assigner
References
Impacted products
Vendor Product Version
n/a Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) Affected: Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330 - Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-01T14:45:23",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7548",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-330 - Use of Insufficiently Random Values"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7548",
    "datePublished": "2020-12-01T14:45:23",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.533Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7548 (GCVE-0-2020-7548)

Vulnerability from nvd – Published: 2020-12-01 14:45 – Updated: 2024-08-04 09:33
VLAI?
Summary
A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.
Severity ?
No CVSS data available.
CWE
  • CWE-330 - - Use of Insufficiently Random Values
Assigner
References
Impacted products
Vendor Product Version
n/a Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) Affected: Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330 - Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-01T14:45:23",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7548",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-330 - Use of Insufficiently Random Values"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-287-03/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7548",
    "datePublished": "2020-12-01T14:45:23",
    "dateReserved": "2020-01-21T00:00:00",
    "dateUpdated": "2024-08-04T09:33:19.533Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}