Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    2 vulnerabilities by Apollo Pharmacy

    CVE-2026-50034 (GCVE-0-2026-50034)

    Vulnerability from cvelistv5 – Published: 2026-06-18 23:47 – Updated: 2026-06-18 23:47
    VLAI
    Title
    Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information
    Summary
    An attacker within BLE communication range can passively intercept wireless traffic and obtain sensitive health-related information, including glucose measurement values.
    CWE
    Assigner
    Impacted products
    Credits
    Rishitha Pucchakayala and Centre for Development of Advanced Computing (Hyderabad) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Blood Glucose Monitoring System (Model No. APG-01 BT)",
              "vendor": "Apollo Pharmacy",
              "versions": [
                {
                  "status": "affected",
                  "version": "0x0110_v1.1.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Rishitha Pucchakayala and Centre for Development of Advanced Computing (Hyderabad) reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An attacker within BLE communication range can passively intercept \nwireless traffic and obtain sensitive health-related information, \nincluding glucose measurement values."
                }
              ],
              "value": "An attacker within BLE communication range can passively intercept \nwireless traffic and obtain sensitive health-related information, \nincluding glucose measurement values."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-18T23:47:13.970Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.apollopharmacy.in/contact-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/news/understanding-bluetooth-technology"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-169-01"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-169-01.json"
            }
          ],
          "source": {
            "advisory": "ICSMA-26-169-01",
            "discovery": "EXTERNAL"
          },
          "title": "Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Cleartext Transmission of Sensitive Information",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eApollo Pharmacy did not respond to CISA\u0027s requests to coordinate. \nUsers are encouraged to reach out to Apollo Pharmacy directly for more \ninformation:\u003cbr\u003e\u003ca href=\"https://www.apollopharmacy.in/contact-us\"\u003ehttps://www.apollopharmacy.in/contact-us\u003c/a\u003e\u003c/p\u003e\n\u003cp\u003e\u003cbr\u003eCISA recommends users follow the \nguidance in the Understanding Bluetooth Technology blog:\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.cisa.gov/news-events/news/understanding-bluetooth-technology\"\u003ehttps://www.cisa.gov/news-events/news/understanding-bluetooth-technology\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Apollo Pharmacy did not respond to CISA\u0027s requests to coordinate. \nUsers are encouraged to reach out to Apollo Pharmacy directly for more \ninformation:\n https://www.apollopharmacy.in/contact-us \n\n\n\n\n\nCISA recommends users follow the \nguidance in the Understanding Bluetooth Technology blog:\u00a0\n https://www.cisa.gov/news-events/news/understanding-bluetooth-technology"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-50034",
        "datePublished": "2026-06-18T23:47:13.970Z",
        "dateReserved": "2026-06-10T21:21:12.237Z",
        "dateUpdated": "2026-06-18T23:47:13.970Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-52866 (GCVE-0-2026-52866)

    Vulnerability from cvelistv5 – Published: 2026-06-18 23:45 – Updated: 2026-06-18 23:45
    VLAI
    Title
    Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Missing Authorization
    Summary
    An attacker within BLE communication range can monopolize the device's only available BLE connection slot, preventing legitimate users or applications from establishing a connection.
    CWE
    Assigner
    Impacted products
    Credits
    Rishitha Pucchakayala and Centre for Development of Advanced Computing (Hyderabad) reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Blood Glucose Monitoring System (Model No. APG-01 BT)",
              "vendor": "Apollo Pharmacy",
              "versions": [
                {
                  "status": "affected",
                  "version": "0x0110_v1.1.0"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Rishitha Pucchakayala and Centre for Development of Advanced Computing (Hyderabad) reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An attacker within BLE communication range can monopolize the device\u0027s \nonly available BLE connection slot, preventing legitimate users or \napplications from establishing a connection."
                }
              ],
              "value": "An attacker within BLE communication range can monopolize the device\u0027s \nonly available BLE connection slot, preventing legitimate users or \napplications from establishing a connection."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 7.1,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-18T23:45:34.263Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.apollopharmacy.in/contact-us"
            },
            {
              "url": "https://www.cisa.gov/news-events/news/understanding-bluetooth-technology"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-169-01"
            },
            {
              "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-169-01.json"
            }
          ],
          "source": {
            "advisory": "ICSMA-26-169-01",
            "discovery": "EXTERNAL"
          },
          "title": "Apollo Pharmacy Blood Glucose Monitoring System APG-01 BT Missing Authorization",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eApollo Pharmacy did not respond to CISA\u0027s requests to coordinate. \nUsers are encouraged to reach out to Apollo Pharmacy directly for more \ninformation:\u003cbr\u003e\u003ca href=\"https://www.apollopharmacy.in/contact-us\"\u003ehttps://www.apollopharmacy.in/contact-us\u003c/a\u003e\u003c/p\u003e\n\u003cp\u003e\u003cbr\u003eCISA recommends users follow the \nguidance in the Understanding Bluetooth Technology blog:\u0026nbsp;\u003cbr\u003e\u003ca href=\"https://www.cisa.gov/news-events/news/understanding-bluetooth-technology\"\u003ehttps://www.cisa.gov/news-events/news/understanding-bluetooth-technology\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Apollo Pharmacy did not respond to CISA\u0027s requests to coordinate. \nUsers are encouraged to reach out to Apollo Pharmacy directly for more \ninformation:\n https://www.apollopharmacy.in/contact-us \n\n\n\n\n\nCISA recommends users follow the \nguidance in the Understanding Bluetooth Technology blog:\u00a0\n https://www.cisa.gov/news-events/news/understanding-bluetooth-technology"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-52866",
        "datePublished": "2026-06-18T23:45:34.263Z",
        "dateReserved": "2026-06-10T21:21:12.261Z",
        "dateUpdated": "2026-06-18T23:45:34.263Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }