Search criteria
28 vulnerabilities by Crestron
CVE-2025-47415 (GCVE-0-2025-47415)
Vulnerability from cvelistv5 – Published: 2025-09-09 19:20 – Updated: 2025-09-10 15:47
VLAI?
Summary
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in CRESTRON TOUCHSCREENS x70 allows Relative Path Traversal.This issue affects TOUCHSCREENS x70: from 3.000.0110.001 before 3.001.0031.001.
Confirmed Affected Hardware: TSW-760, TSW-1060
Confirmed Affected Firmware: 3.002.1061 - (no fix released, product discontinued)
For x70
The Affected Firmware:- 3.000.0110.001 and versions below
The Fixed Firmware:- 3.001.0031.001
Severity ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CRESTRON | TOUCHSCREENS x60, x70 series |
Affected:
3.000.0110.001 , < 3.001.0031.001
(custom)
|
Credits
IBM
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47415",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-10T15:41:57.276783Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-10T15:47:05.306Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TOUCHSCREENS x60, x70 series",
"vendor": "CRESTRON",
"versions": [
{
"changes": [
{
"at": "3.001.0031.001",
"status": "unaffected"
}
],
"lessThan": "3.001.0031.001",
"status": "affected",
"version": "3.000.0110.001",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "IBM"
}
],
"datePublic": "2025-06-09T18:54:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in CRESTRON TOUCHSCREENS x70 allows Relative Path Traversal.\u003cp\u003eThis issue affects TOUCHSCREENS x70: from 3.000.0110.001 before 3.001.0031.001.\u003cbr\u003e\u003cbr\u003e\n\n\u003c/p\u003e\u003cdiv\u003e\u003cp\u003e\u003c/p\u003e\u003c/div\u003e\n\n\u003cdiv\u003e\u003cp\u003eConfirmed Affected Hardware:\u202fTSW-760, TSW-1060 \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u003cspan style=\"background-color: transparent;\"\u003eConfirmed Affected Firmware:\u202f3.002.1061\u003c/span\u003e\u0026nbsp;- \u003ci\u003e(no fix released, product discontinued)\u003c/i\u003e\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eFor x70\u202f\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eThe Affected Firmware:- 3.000.0110.001 \u202fand versions below \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eThe Fixed Firmware:- 3.001.0031.001 \u003c/p\u003e\u003c/div\u003e\n\n\u003cdiv\u003e\u003cp\u003e \u003c/p\u003e\u003c/div\u003e\n\n\u003cbr\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in CRESTRON TOUCHSCREENS x70 allows Relative Path Traversal.This issue affects TOUCHSCREENS x70: from 3.000.0110.001 before 3.001.0031.001.\n\n\n\n\n\n\n\n\n\n\n\nConfirmed Affected Hardware:\u202fTSW-760, TSW-1060 \n\n\n\nConfirmed Affected Firmware:\u202f3.002.1061\u00a0- (no fix released, product discontinued)\n\n\n\n\u00a0\n\nFor x70\u202f\u00a0\n\n\n\nThe Affected Firmware:- 3.000.0110.001 \u202fand versions below \n\n\n\nThe Fixed Firmware:- 3.001.0031.001"
}
],
"impacts": [
{
"capecId": "CAPEC-139",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-139 Relative Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T19:20:35.244Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com"
},
{
"tags": [
"patch"
],
"url": "https://www.crestron.com/Software-Firmware/Firmware/Touchpanels/TS-770-TS-1070-TSS-770-TSS-1070-TSW-570/3-002-0040-001"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "RECWAVE Filepath Traversal",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47415",
"datePublished": "2025-09-09T19:20:35.244Z",
"dateReserved": "2025-05-06T19:36:18.439Z",
"dateUpdated": "2025-09-10T15:47:05.306Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47416 (GCVE-0-2025-47416)
Vulnerability from cvelistv5 – Published: 2025-09-09 13:52 – Updated: 2025-09-09 14:06
VLAI?
Summary
A vulnerability exists in the ConsoleFindCommandMatchList function in libsymproc. so imported by ctpd that may lead to unauthorized execution of an attacker-defined file that gets prioritized by the ConsoleFindCommandMatchList.
A third-party researcher discovered that the ConsoleFindCommandMatchList enumerates the /dev/shm/symproc/c directory in alphabetical order to identify console commands. Permission levels are inferred from the integer values present in each command's file name.
Confirmed Affected Hardware: TSW-760, TSW-1060
Confirmed Affected Firmware: 3.002.1061
Fixed Firmware: no fixed released (product is discontinued and end of life)
For x70
The Affected Firmware:- 3.000.0110.001 and versions below
The Fixed Firmware:- 3.001.0031.001
Severity ?
CWE
- CWE-697 - Incorrect Comparison
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| CRESTRON | TOUCHSCREEN x70 |
Affected:
3.000.0110.001 , < 3.001.0031.001
(custom)
|
|||||||
|
|||||||||
Credits
IBM
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47416",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-09T14:06:09.910159Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T14:06:41.093Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TOUCHSCREEN x70",
"vendor": "CRESTRON",
"versions": [
{
"changes": [
{
"at": "3.001.0031.001",
"status": "unaffected"
}
],
"lessThan": "3.001.0031.001",
"status": "affected",
"version": "3.000.0110.001",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Touchscreen x60s",
"vendor": "CRESTRON",
"versions": [
{
"status": "affected",
"version": "3.002.1061"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "IBM"
}
],
"datePublic": "2025-06-09T13:21:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability exists in the ConsoleFindCommandMatchList\u202ffunction in libsymproc. so\u202fimported by ctpd that may lead to unauthorized execution of an attacker-defined file that gets prioritized by the ConsoleFindCommandMatchList.\u003cbr\u003e\u003cbr\u003e\n\nA third-party researcher discovered that the ConsoleFindCommandMatchList\u202fenumerates the /dev/shm/symproc/c directory in alphabetical order to identify console commands. Permission levels are inferred from the integer values present in each command\u0027s file name.\u0026nbsp;\u003cbr\u003e\u003cbr\u003e\n\n\u003cdiv\u003e\u003cp\u003eConfirmed Affected Hardware:\u202fTSW-760, TSW-1060 \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u003cspan style=\"background-color: rgb(239, 250, 102);\"\u003eConfirmed Affected Firmware:\u202f3.002.1061\u0026nbsp;\u003c/span\u003e\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eFixed Firmware: no fixed released\u0026nbsp;\u003ci\u003e(product is discontinued and end of life)\u003c/i\u003e\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eFor x70\u202f\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eThe Affected Firmware:- 3.000.0110.001 \u202fand versions below \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003eThe Fixed Firmware:- 3.001.0031.001\u003c/p\u003e\u003c/div\u003e\u003cbr\u003e"
}
],
"value": "A vulnerability exists in the ConsoleFindCommandMatchList\u202ffunction in libsymproc. so\u202fimported by ctpd that may lead to unauthorized execution of an attacker-defined file that gets prioritized by the ConsoleFindCommandMatchList.\n\n\n\nA third-party researcher discovered that the ConsoleFindCommandMatchList\u202fenumerates the /dev/shm/symproc/c directory in alphabetical order to identify console commands. Permission levels are inferred from the integer values present in each command\u0027s file name.\u00a0\n\n\n\nConfirmed Affected Hardware:\u202fTSW-760, TSW-1060 \n\n\n\nConfirmed Affected Firmware:\u202f3.002.1061\u00a0\n\n\n\nFixed Firmware: no fixed released\u00a0(product is discontinued and end of life)\n\n\n\n\u00a0\n\n\n\nFor x70\u202f\u00a0\n\n\n\nThe Affected Firmware:- 3.000.0110.001 \u202fand versions below \n\n\n\nThe Fixed Firmware:- 3.001.0031.001"
}
],
"impacts": [
{
"capecId": "CAPEC-43",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-43 Exploiting Multiple Input Interpretation Layers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-697",
"description": "CWE-697 Incorrect Comparison",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T13:52:45.855Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com"
},
{
"tags": [
"patch"
],
"url": "https://www.crestron.com/Software-Firmware/Firmware/Touchpanels/TS-770-TS-1070-TSS-770-TSS-1070-TSW-570/3-002-0040-001"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "ConsoleFindCommandMatchList",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47416",
"datePublished": "2025-09-09T13:52:45.855Z",
"dateReserved": "2025-05-06T19:36:18.440Z",
"dateUpdated": "2025-09-09T14:06:41.093Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47421 (GCVE-0-2025-47421)
Vulnerability from cvelistv5 – Published: 2025-09-03 13:49 – Updated: 2025-09-03 13:59
VLAI?
Summary
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability in CRESTRON TOUCHSCREENS x70 allows Argument Injection.This issue affects TOUCHSCREENS x70: from 3.001.0031.001 through 3.001.0034.001.
A specially crafted SCP command sent via SSH login string can lead a valid administrator user to gain Privileged Operating System access on the device.
Following Products Models are affected:
TSW-x70
TSW-x60
TST-1080
AM-3000/3100/3200
Soundbar VB70
HD-PS622/621/402
HD-TXU-RXU-4kZ-211
HD-MDNXM-4KZ-E
*Note: additional firmware updates will be published once made available
Severity ?
CWE
- CWE-88 - Improper Neutralization of Argument Delimiters in a Command ('Argument Injection')
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| CRESTRON | TOUCHSCREENS x70 |
Affected:
3.001.0031.001 , < 3.001.0034.001
(custom)
|
Credits
Frank Slezak
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47421",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-03T13:59:12.682369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-03T13:59:32.186Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "TOUCHSCREENS x70",
"vendor": "CRESTRON",
"versions": [
{
"lessThan": "3.001.0034.001",
"status": "affected",
"version": "3.001.0031.001",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Frank Slezak"
}
],
"datePublic": "2025-07-25T13:24:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027) vulnerability in CRESTRON TOUCHSCREENS x70 allows Argument Injection.\u003cp\u003eThis issue affects TOUCHSCREENS x70: from 3.001.0031.001 through 3.001.0034.001.\u003cbr\u003e\u003cbr\u003eA specially crafted SCP command sent via SSH login string can lead a valid administrator user to gain Privileged Operating System access on the device.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eFollowing Products Models are affected:\u003cbr\u003e\u003cbr\u003eTSW-x70 \u003cbr\u003eTSW-x60 \u003cbr\u003eTST-1080\u003cbr\u003eAM-3000/3100/3200\u003cbr\u003eSoundbar VB70\u003cbr\u003eHD-PS622/621/402\u003cbr\u003eHD-TXU-RXU-4kZ-211\u003cbr\u003eHD-MDNXM-4KZ-E\u003cbr\u003e\u003cbr\u003e*Note: additional firmware updates will be published once made available\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027) vulnerability in CRESTRON TOUCHSCREENS x70 allows Argument Injection.This issue affects TOUCHSCREENS x70: from 3.001.0031.001 through 3.001.0034.001.\n\nA specially crafted SCP command sent via SSH login string can lead a valid administrator user to gain Privileged Operating System access on the device.\n\n\nFollowing Products Models are affected:\n\nTSW-x70 \nTSW-x60 \nTST-1080\nAM-3000/3100/3200\nSoundbar VB70\nHD-PS622/621/402\nHD-TXU-RXU-4kZ-211\nHD-MDNXM-4KZ-E\n\n*Note: additional firmware updates will be published once made available"
}
],
"impacts": [
{
"capecId": "CAPEC-6",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-6 Argument Injection"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-88",
"description": "CWE-88 Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-03T13:49:40.856Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com"
},
{
"tags": [
"patch"
],
"url": "https://https://www.crestron.com/Software-Firmware/Firmware/Touchpanels/TS-770-TS-1070-TSS-770-TSS-1070-TSW-570/3-002-0040-001"
},
{
"tags": [
"release-notes"
],
"url": "https://https://www.crestron.com/release_notes/tsw-xx70_3.002.0040.001_release_notes.pdf"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Privilege escalation via SCP login",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47421",
"datePublished": "2025-09-03T13:49:40.856Z",
"dateReserved": "2025-05-06T19:36:18.441Z",
"dateUpdated": "2025-09-03T13:59:32.186Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47420 (GCVE-0-2025-47420)
Vulnerability from cvelistv5 – Published: 2025-05-06 21:33 – Updated: 2025-05-07 14:03
VLAI?
Summary
266 vulnerability in Crestron Automate VX allows Privilege Escalation.This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Severity ?
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Automate VX |
Affected:
5.6.8161.21536 , ≤ 6.4.0.49
(custom)
|
Credits
Crestron Electronics Inc
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47420",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T13:46:20.078463Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T14:03:50.793Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automate VX",
"vendor": "Crestron",
"versions": [
{
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"lessThanOrEqual": "6.4.0.49",
"status": "affected",
"version": "5.6.8161.21536",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Crestron Electronics Inc"
}
],
"datePublic": "2025-04-23T21:15:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "266 vulnerability in Crestron Automate VX allows Privilege Escalation.\u003cp\u003eThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.\u003c/p\u003e"
}
],
"value": "266 vulnerability in Crestron Automate VX allows Privilege Escalation.This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T21:33:39.188Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com/"
},
{
"tags": [
"patch"
],
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"
},
{
"tags": [
"release-notes"
],
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will applies user permissions to API requests. \u003cbr\u003e"
}
],
"value": "Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will applies user permissions to API requests."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "User Permissions on Network API",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Limit all API usage to users with full permissions.\n\n\u003cbr\u003e"
}
],
"value": "Limit all API usage to users with full permissions."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47420",
"datePublished": "2025-05-06T21:33:39.188Z",
"dateReserved": "2025-05-06T19:36:18.441Z",
"dateUpdated": "2025-05-07T14:03:50.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47419 (GCVE-0-2025-47419)
Vulnerability from cvelistv5 – Published: 2025-05-06 20:52 – Updated: 2025-05-07 14:03
VLAI?
Summary
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Severity ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Automate VX |
Affected:
5.6.8161.21536 , ≤ 6.4.0.49
(custom)
|
Credits
Crestron Electronics Inc
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47419",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T13:47:55.617300Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T14:03:57.638Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automate VX",
"vendor": "Crestron",
"versions": [
{
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"lessThanOrEqual": "6.4.0.49",
"status": "affected",
"version": "5.6.8161.21536",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Crestron Electronics Inc"
}
],
"datePublic": "2025-04-23T20:47:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\u003cbr\u003e\u003cbr\u003eThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\u003cbr\u003e\u003cp\u003eThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.\u003c/p\u003e"
}
],
"value": "Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.\n\nThe device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.\n\n\nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
}
],
"impacts": [
{
"capecId": "CAPEC-158",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-158 Sniffing Network Traffic"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T20:52:44.604Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com/"
},
{
"tags": [
"patch"
],
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"
},
{
"tags": [
"release-notes"
],
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCrestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will disables the use of unsecure ports for the Web UI and API.\u003cbr\u003e\u003c/p\u003e"
}
],
"value": "Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will disables the use of unsecure ports for the Web UI and API."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Non-Secure Access",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Protect the device at the physical or network layer using an external firewall to prevent unauthorized configuration. \u003cbr\u003e"
}
],
"value": "Protect the device at the physical or network layer using an external firewall to prevent unauthorized configuration."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47419",
"datePublished": "2025-05-06T20:52:44.604Z",
"dateReserved": "2025-05-06T19:36:18.441Z",
"dateUpdated": "2025-05-07T14:03:57.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47418 (GCVE-0-2025-47418)
Vulnerability from cvelistv5 – Published: 2025-05-06 20:13 – Updated: 2025-05-07 14:04
VLAI?
Summary
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.
There is no visible indication when the system is recording and recording can be enabled remotely via a network API.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Severity ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Automate VX |
Affected:
5.6.8161.21536 , ≤ 6.4.0.49
(custom)
|
Credits
Crestron Electronics Inc
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47418",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-07T13:46:13.710646Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-07T14:04:11.178Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automate VX",
"vendor": "Crestron",
"versions": [
{
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"lessThanOrEqual": "6.4.0.49",
"status": "affected",
"version": "5.6.8161.21536",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Crestron Electronics Inc"
}
],
"datePublic": "2025-04-23T20:04:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.\u003cbr\u003e\u003cbr\u003eThere is no visible indication when the system is recording and recording can be enabled remotely via a network API. \u003cbr\u003e\u003cp\u003eThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.\u003c/p\u003e"
}
],
"value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.\n\nThere is no visible indication when the system is recording and recording can be enabled remotely via a network API. \nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
}
],
"impacts": [
{
"capecId": "CAPEC-212",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-212 Functionality Misuse"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T20:20:24.812Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com/"
},
{
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"
},
{
"tags": [
"release-notes"
],
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCrestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will\u0026nbsp;\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eadds \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ea\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e visual\u003c/span\u003e \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eindication\u003c/span\u003e \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eon \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ethe program \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003evideo output \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ewhen recording is \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003estarted\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u0026nbsp;\u003c/span\u003e\u003cbr\u003e"
}
],
"value": "Crestron recommends updating to firmware version 6.4.1.8 or higher. The firmware version will\u00a0adds a visual indication on the program video output when recording is started."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Recording",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInform users in the room that they may be recorded. Also, configure the network to only allow needed systems and/or devices to access the API.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Inform users in the room that they may be recorded. Also, configure the network to only allow needed systems and/or devices to access the API."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47418",
"datePublished": "2025-05-06T20:13:38.805Z",
"dateReserved": "2025-05-06T19:36:18.441Z",
"dateUpdated": "2025-05-07T14:04:11.178Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-47417 (GCVE-0-2025-47417)
Vulnerability from cvelistv5 – Published: 2025-05-06 19:49 – Updated: 2025-05-08 18:35
VLAI?
Summary
Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.
When Enable Debug Images in Crestron Automate VX is active, snapshots of the captured video or portions thereof are stored locally on the system, and there is no visible indication that this is being done.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
Severity ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
| URL | Tags | |
|---|---|---|
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Automate VX |
Affected:
5.6.8161.21536 , ≤ 6.4.0.49
(custom)
|
Credits
Crestron Electronics Inc
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-47417",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T18:34:55.584949Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-08T18:35:06.098Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automate VX",
"vendor": "Crestron",
"versions": [
{
"changes": [
{
"at": "6.4.1.8",
"status": "unaffected"
}
],
"lessThanOrEqual": "6.4.0.49",
"status": "affected",
"version": "5.6.8161.21536",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Crestron Electronics Inc"
}
],
"datePublic": "2025-04-23T19:48:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.\u003cbr\u003e\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eWhen Enable Debug Images in Crestron Automate VX is active, snapshots of the captured video or portions thereof are stored locally on the system, and there is no visible indication that this is being done.\u003c/span\u003e\n\n\u003cbr\u003e\u003cp\u003eThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.\u003c/p\u003e"
}
],
"value": "Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Crestron Automate VX allows Functionality Misuse.\n\n\n\nWhen Enable Debug Images in Crestron Automate VX is active, snapshots of the captured video or portions thereof are stored locally on the system, and there is no visible indication that this is being done.\n\n\nThis issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49."
}
],
"impacts": [
{
"capecId": "CAPEC-212",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-212 Functionality Misuse"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-06T19:49:09.288Z",
"orgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"shortName": "Crestron"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://security.crestron.com"
},
{
"tags": [
"patch"
],
"url": "https://www.crestron.com/Software-Firmware/Software/Automate-VX-Software/6-4-1-8"
},
{
"url": "https://www.crestron.com/release_notes/automate_vx_6.4.1.8_release_notes.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Crestron recommends updating the software to firmware version\u0026nbsp;6.4.1.8 or higher. The\u0026nbsp;firmware update will automatically disables the Enable Debug Images Mode on system startup and reboot (which occurs daily), or if manually disabled, whichever occurs first, and automatically deletes captured images in 24 hours. While active, a visual overlay is applied to the program video output indicating Debug Images Enabled."
}
],
"value": "Crestron recommends updating the software to firmware version\u00a06.4.1.8 or higher. The\u00a0firmware update will automatically disables the Enable Debug Images Mode on system startup and reboot (which occurs daily), or if manually disabled, whichever occurs first, and automatically deletes captured images in 24 hours. While active, a visual overlay is applied to the program video output indicating Debug Images Enabled."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Enable Debug Images",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDeactivate Enable Debug Images and delete stored images.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Deactivate Enable Debug Images and delete stored images."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "25b0b659-c4b4-483f-aecb-067757d23ef3",
"assignerShortName": "Crestron",
"cveId": "CVE-2025-47417",
"datePublished": "2025-05-06T19:49:09.288Z",
"dateReserved": "2025-05-06T19:36:18.441Z",
"dateUpdated": "2025-05-08T18:35:06.098Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-6926 (GCVE-0-2023-6926)
Vulnerability from cvelistv5 – Published: 2024-01-23 19:23 – Updated: 2024-11-13 15:54
VLAI?
Summary
There is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.
Severity ?
8.4 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Credits
Uri Katz of Claroty Research Team82
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T08:42:08.538Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"government-resource",
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-023-02"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-6926",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-01-29T16:20:29.212401Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-13T15:54:03.385Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "AM-300",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": " 1.4499.00018"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Uri Katz of Claroty Research Team82"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eThere is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.\u003c/span\u003e\n\n"
}
],
"value": "\nThere is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-23T19:23:08.788Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-023-02"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCrestron has resolved this vulnerability in firmware version 1.4499.00023.001 or higher. Please see \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://security.crestron.com/\"\u003ehttps://security.crestron.com\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;or contact True Blue Support for additional information.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "\nCrestron has resolved this vulnerability in firmware version 1.4499.00023.001 or higher. Please see https://security.crestron.com https://security.crestron.com/ \u00a0or contact True Blue Support for additional information.\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) in Crestron AM-300",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2023-6926",
"datePublished": "2024-01-23T19:23:08.788Z",
"dateReserved": "2023-12-18T15:44:37.002Z",
"dateUpdated": "2024-11-13T15:54:03.385Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40298 (GCVE-0-2022-40298)
Vulnerability from cvelistv5 – Published: 2022-09-22 23:30 – Updated: 2025-05-27 15:23
VLAI?
Summary
Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:14:40.215Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-40298",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-27T15:22:47.788281Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T15:23:18.955Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-22T23:30:16.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-40298",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AirMedia for Windows before 5.5.1.84 has insecure inherited permissions, which leads to a privilege escalation vulnerability found in the AirMedia Windows Application, version 4.3.1.39. A low privileged user can initiate a repair of the system and gain a SYSTEM level shell."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.crestron.com/Security/Security_Advisories",
"refsource": "MISC",
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"name": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf",
"refsource": "MISC",
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-40298",
"datePublished": "2022-09-22T23:30:16.000Z",
"dateReserved": "2022-09-08T00:00:00.000Z",
"dateUpdated": "2025-05-27T15:23:18.955Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34101 (GCVE-0-2022-34101)
Vulnerability from cvelistv5 – Published: 2022-09-13 21:47 – Updated: 2024-08-03 08:16
VLAI?
Summary
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can place a malicious DLL in a certain path to execute code and preform a privilege escalation attack.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:16:16.512Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can place a malicious DLL in a certain path to execute code and preform a privilege escalation attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T21:47:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-34101",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can place a malicious DLL in a certain path to execute code and preform a privilege escalation attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.crestron.com/Security/Security_Advisories",
"refsource": "MISC",
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"name": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf",
"refsource": "MISC",
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-34101",
"datePublished": "2022-09-13T21:47:01",
"dateReserved": "2022-06-20T00:00:00",
"dateUpdated": "2024-08-03T08:16:16.512Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34102 (GCVE-0-2022-34102)
Vulnerability from cvelistv5 – Published: 2022-09-13 21:42 – Updated: 2024-08-03 08:16
VLAI?
Summary
Insufficient access control vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can pause the uninstallation of an executable to gain a SYSTEM level command prompt.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:16:16.877Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient access control vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can pause the uninstallation of an executable to gain a SYSTEM level command prompt."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T21:42:19",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-34102",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient access control vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a user can pause the uninstallation of an executable to gain a SYSTEM level command prompt."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.crestron.com/Security/Security_Advisories",
"refsource": "MISC",
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"name": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf",
"refsource": "MISC",
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-34102",
"datePublished": "2022-09-13T21:42:19",
"dateReserved": "2022-06-20T00:00:00",
"dateUpdated": "2024-08-03T08:16:16.877Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34100 (GCVE-0-2022-34100)
Vulnerability from cvelistv5 – Published: 2022-09-13 18:11 – Updated: 2024-08-03 08:16
VLAI?
Summary
A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:16:16.644Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T18:11:22",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-34100",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was discovered in the Crestron AirMedia Windows Application, version 4.3.1.39, in which a low-privileged user can gain a SYSTEM level command prompt by pre-staging a file structure prior to the installation of a trusted service executable and change permissions on that file structure during a repair operation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.crestron.com/Security/Security_Advisories",
"refsource": "MISC",
"url": "https://www.crestron.com/Security/Security_Advisories"
},
{
"name": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf",
"refsource": "MISC",
"url": "https://www.crestron.com/release_notes/airmedia_windows_installer_release_notes_5.5.1.84.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-34100",
"datePublished": "2022-09-13T18:11:22",
"dateReserved": "2022-06-20T00:00:00",
"dateUpdated": "2024-08-03T08:16:16.644Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3939 (GCVE-0-2019-3939)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:40 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device.
Severity ?
No CVSS data available.
CWE
- CWE-16 - Default Credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.803Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-16",
"description": "CWE-16: Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:40:18",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3939",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the web interface. An unauthenticated, remote attacker can use these credentials to gain privileged access to the device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-16: Default Credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3939",
"datePublished": "2019-04-30T20:40:18",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.803Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3938 (GCVE-0-2019-3938)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:39 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the "export configuration" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords.
Severity ?
No CVSS data available.
CWE
- CWE-522 - Insufficiently protectect credentials
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.938Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the \"export configuration\" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-522",
"description": "CWE-522: Insufficiently protectect credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:39:24",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3938",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the file generated via the \"export configuration\" feature. The configuration file is encrypted using the awenc binary. The same binary can be used to decrypt any configuration file since all the encryption logic is hard coded. A local attacker can use this vulnerability to gain access to devices username and passwords."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-522: Insufficiently protectect credentials"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3938",
"datePublished": "2019-04-30T20:39:24",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.938Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3937 (GCVE-0-2019-3937)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:38 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data.
Severity ?
No CVSS data available.
CWE
- CWE-312 - Cleartext Storage
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.781Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-312",
"description": "CWE-312: Cleartext Storage",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:38:24",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3937",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-312: Cleartext Storage"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3937",
"datePublished": "2019-04-30T20:38:24",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.781Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3936 (GCVE-0-2019-3936)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:35 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a "stopped" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.921Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a \"stopped\" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:35:48",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3936",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port 389. The request will force the slideshow to transition into a \"stopped\" state. A remote, unauthenticated attacker can use this vulnerability to stop an active slideshow."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3936",
"datePublished": "2019-04-30T20:35:48",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.921Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3935 (GCVE-0-2019-3935)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:34 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.786Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:34:51",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3935",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP POST requests to conference.cgi. A remote, unauthenticated attacker can use this vulnerability to start, stop, and disconnect active slideshows."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3935",
"datePublished": "2019-04-30T20:34:51",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3934 (GCVE-0-2019-3934)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:34 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.453Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:34:03",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3934",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP POST request to login.cgi. A remote, unauthenticated attacker can use this vulnerability to download the current slide image without knowing the access code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3934",
"datePublished": "2019-04-30T20:34:03",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.453Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3933 (GCVE-0-2019-3933)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:30 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.523Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:30:50",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3933",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /images/browserslide.jpg via HTTP. A remote, unauthenticated attacker can use this vulnerability to watch a slideshow without knowing the access code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3933",
"datePublished": "2019-04-30T20:30:50",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.523Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3932 (GCVE-0-2019-3932)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:30 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge.
Severity ?
No CVSS data available.
CWE
- CWE-249 - Hard-coded Password
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.558Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-249",
"description": "CWE-249 Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:30:02",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3932",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password in return.tgi. A remote, unauthenticated attacker can use this vulnerability to control external devices via the uart_bridge."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-249 Hard-coded Password"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3932",
"datePublished": "2019-04-30T20:30:02",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.558Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3931 (GCVE-0-2019-3931)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:28 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root.
Severity ?
No CVSS data available.
CWE
- CWE-88 - Argument Injection
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.568Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-88",
"description": "CWE-88 Argument Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:28:44",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3931",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-88 Argument Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3931",
"datePublished": "2019-04-30T20:28:44",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.568Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3930 (GCVE-0-2019-3930)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:25 – Updated: 2024-08-04 19:26
VLAI?
Summary
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so's PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint.
Severity ?
No CVSS data available.
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4. |
Affected:
Crestron AM-100 firmware 1.6.0.2
Affected: Crestron AM-101 firmware 2.7.0.1 Affected: Barco wePresent WiPG-1000P firmware 2.3.0.10 Affected: Barco wePresent WiPG-1600W before firmware 2.4.1.19 Affected: Extron ShareLink 200/250 firmware 2.0.3.4 Affected: Teq AV IT WIPS710 firmware 1.1.0.7 Affected: SHARP PN-L703WA firmware 1.4.2.3 Affected: Optoma WPS-Pro firmware 1.0.0.5 Affected: Blackbox HD WPS firmware 1.0.0.5 Affected: InFocus LiteShow3 firmware 1.0.16 Affected: and InFocus LiteShow4 2.0.0.7 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.743Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "Crestron AM-100 firmware 1.6.0.2"
},
{
"status": "affected",
"version": "Crestron AM-101 firmware 2.7.0.1"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"status": "affected",
"version": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"status": "affected",
"version": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"status": "affected",
"version": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"status": "affected",
"version": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"status": "affected",
"version": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"status": "affected",
"version": "InFocus LiteShow3 firmware 1.0.16"
},
{
"status": "affected",
"version": "and InFocus LiteShow4 2.0.0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so\u0027s PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:25:56",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3930",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"version": {
"version_data": [
{
"version_value": "Crestron AM-100 firmware 1.6.0.2"
},
{
"version_value": "Crestron AM-101 firmware 2.7.0.1"
},
{
"version_value": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"version_value": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"version_value": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"version_value": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"version_value": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"version_value": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"version_value": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"version_value": "InFocus LiteShow3 firmware 1.0.16"
},
{
"version_value": "and InFocus LiteShow4 2.0.0.7"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to a stack buffer overflow in libAwgCgi.so\u0027s PARSERtoCHAR function. A remote, unauthenticated attacker can use this vulnerability to execute arbitrary code as root via a crafted request to the return.cgi endpoint."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3930",
"datePublished": "2019-04-30T20:25:56",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.743Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3929 (GCVE-0-2019-3929)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:21 – Updated: 2025-10-21 23:45
VLAI?
Summary
The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Severity ?
9.8 (Critical)
CWE
- CWE-79 - OS Command Injection
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4. |
Affected:
Crestron AM-100 firmware 1.6.0.2
Affected: Crestron AM-101 firmware 2.7.0.1 Affected: Barco wePresent WiPG-1000P firmware 2.3.0.10 Affected: Barco wePresent WiPG-1600W before firmware 2.4.1.19 Affected: Extron ShareLink 200/250 firmware 2.0.3.4 Affected: Teq AV IT WIPS710 firmware 1.1.0.7 Affected: SHARP PN-L703WA firmware 1.4.2.3 Affected: Optoma WPS-Pro firmware 1.0.0.5 Affected: Blackbox HD WPS firmware 1.0.0.5 Affected: InFocus LiteShow3 firmware 1.0.16 Affected: and InFocus LiteShow4 2.0.0.7 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.549Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-3929",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T20:26:27.910638Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2022-04-15",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:45:38.287Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-04-15T00:00:00+00:00",
"value": "CVE-2019-3929 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "Crestron AM-100 firmware 1.6.0.2"
},
{
"status": "affected",
"version": "Crestron AM-101 firmware 2.7.0.1"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"status": "affected",
"version": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"status": "affected",
"version": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"status": "affected",
"version": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"status": "affected",
"version": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"status": "affected",
"version": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"status": "affected",
"version": "InFocus LiteShow3 firmware 1.0.16"
},
{
"status": "affected",
"version": "and InFocus LiteShow4 2.0.0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-14T17:06:03.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"version": {
"version_data": [
{
"version_value": "Crestron AM-100 firmware 1.6.0.2"
},
{
"version_value": "Crestron AM-101 firmware 2.7.0.1"
},
{
"version_value": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"version_value": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"version_value": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"version_value": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"version_value": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"version_value": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"version_value": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"version_value": "InFocus LiteShow3 firmware 1.0.16"
},
{
"version_value": "and InFocus LiteShow4 2.0.0.7"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"name": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"name": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3929",
"datePublished": "2019-04-30T20:21:09.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:45:38.287Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3928 (GCVE-0-2019-3928)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:18 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.641Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:18:34",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3928",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allow any user to obtain the presentation passcode via the iso.3.6.1.4.1.3212.100.3.2.7.4 OIDs. A remote, unauthenticated attacker can use this vulnerability to access a restricted presentation or to become the presenter."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3928",
"datePublished": "2019-04-30T20:18:34",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.641Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3927 (GCVE-0-2019-3927)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:15 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user's password and gain access to restricted areas on the HTTP interface.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.355Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user\u0027s password and gain access to restricted areas on the HTTP interface."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:15:32",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3927",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 anyone can change the administrator and moderator passwords via the iso.3.6.1.4.1.3212.100.3.2.8.1 and iso.3.6.1.4.1.3212.100.3.2.8.2 OIDs. A remote, unauthenticated attacker can use this vulnerability to change the admin or moderator user\u0027s password and gain access to restricted areas on the HTTP interface."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3927",
"datePublished": "2019-04-30T20:15:32",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.355Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3926 (GCVE-0-2019-3926)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:12 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.14.1. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Severity ?
No CVSS data available.
CWE
- CWE-79 - OS Command Injection
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.268Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.14.1. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:12:46",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3926",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.14.1. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3926",
"datePublished": "2019-04-30T20:12:46",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:27.268Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3925 (GCVE-0-2019-3925)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:09 – Updated: 2024-08-04 19:26
VLAI?
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.
Severity ?
No CVSS data available.
CWE
- CWE-79 - OS Command Injection
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Crestron | Crestron AirMedia |
Affected:
AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:26.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-04-30T20:09:51",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3925",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia",
"version": {
"version_data": [
{
"version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to command injection via SNMP OID iso.3.6.1.4.1.3212.100.3.2.9.3. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3925",
"datePublished": "2019-04-30T20:09:51",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-08-04T19:26:26.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-5553 (GCVE-0-2018-5553)
Vulnerability from cvelistv5 – Published: 2018-07-10 16:00 – Updated: 2024-09-16 22:20
VLAI?
Summary
The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - (Improper Neutralization of Special Elements used in an OS Command)
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
Credits
This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:40:50.678Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DGE-100",
"vendor": "Crestron",
"versions": [
{
"lessThanOrEqual": "1.3384.00049.001",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "TS-1542-C",
"vendor": "Crestron",
"versions": [
{
"lessThanOrEqual": "1.3384.00049.001",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "DM-DGE-200-C",
"vendor": "Crestron",
"versions": [
{
"lessThanOrEqual": "1.3384.00049.001",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
}
],
"datePublic": "2018-06-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-07-10T15:57:01",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
}
],
"solutions": [
{
"lang": "en",
"value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages."
}
],
"source": {
"advisory": "R7-2018-15",
"discovery": "EXTERNAL"
},
"title": "Crestron DGE-100 Console Command Injection (FIXED)",
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "",
"ASSIGNER": "cve@rapid7.com",
"DATE_PUBLIC": "2018-06-12T10:00:00.000Z",
"ID": "CVE-2018-5553",
"STATE": "PUBLIC",
"TITLE": "Crestron DGE-100 Console Command Injection (FIXED)"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DGE-100",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "",
"version_affected": "\u003c=",
"version_name": "",
"version_value": "1.3384.00049.001"
}
]
}
},
{
"product_name": "TS-1542-C",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "",
"version_affected": "\u003c=",
"version_name": "",
"version_value": "1.3384.00049.001"
}
]
}
},
{
"product_name": "DM-DGE-200-C",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "",
"version_affected": "\u003c=",
"version_name": "",
"version_value": "1.3384.00049.001"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"configuration": [],
"credit": [
{
"lang": "eng",
"value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
}
]
},
"exploit": [],
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553",
"refsource": "CONFIRM",
"url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
},
{
"name": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/",
"refsource": "MISC",
"url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages."
}
],
"source": {
"advisory": "R7-2018-15",
"defect": [],
"discovery": "EXTERNAL"
},
"work_around": []
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2018-5553",
"datePublished": "2018-07-10T16:00:00Z",
"dateReserved": "2018-01-12T00:00:00",
"dateUpdated": "2024-09-16T22:20:46.752Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}