CVE-2018-5553 (GCVE-0-2018-5553)
Vulnerability from cvelistv5 – Published: 2018-07-10 16:00 – Updated: 2024-09-16 22:20
VLAI?
Summary
The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.
Severity ?
9.8 (Critical)
CWE
- CWE-78 - (Improper Neutralization of Special Elements used in an OS Command)
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
Credits
This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7's vulnerability disclosure policy (https://www.rapid7.com/disclosure/).
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T05:40:50.678Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "DGE-100",
"vendor": "Crestron",
"versions": [
{
"lessThanOrEqual": "1.3384.00049.001",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "TS-1542-C",
"vendor": "Crestron",
"versions": [
{
"lessThanOrEqual": "1.3384.00049.001",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "DM-DGE-200-C",
"vendor": "Crestron",
"versions": [
{
"lessThanOrEqual": "1.3384.00049.001",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
}
],
"datePublic": "2018-06-12T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-07-10T15:57:01",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
}
],
"solutions": [
{
"lang": "en",
"value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages."
}
],
"source": {
"advisory": "R7-2018-15",
"discovery": "EXTERNAL"
},
"title": "Crestron DGE-100 Console Command Injection (FIXED)",
"x_legacyV4Record": {
"CVE_data_meta": {
"AKA": "",
"ASSIGNER": "cve@rapid7.com",
"DATE_PUBLIC": "2018-06-12T10:00:00.000Z",
"ID": "CVE-2018-5553",
"STATE": "PUBLIC",
"TITLE": "Crestron DGE-100 Console Command Injection (FIXED)"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "DGE-100",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "",
"version_affected": "\u003c=",
"version_name": "",
"version_value": "1.3384.00049.001"
}
]
}
},
{
"product_name": "TS-1542-C",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "",
"version_affected": "\u003c=",
"version_name": "",
"version_value": "1.3384.00049.001"
}
]
}
},
{
"product_name": "DM-DGE-200-C",
"version": {
"version_data": [
{
"affected": "\u003c=",
"platform": "",
"version_affected": "\u003c=",
"version_name": "",
"version_value": "1.3384.00049.001"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"configuration": [],
"credit": [
{
"lang": "eng",
"value": "This issue was discovered by Rapid7 researchers Cale Black and Jordan Larose. It is being disclosed in accordance Rapid7\u0027s vulnerability disclosure policy (https://www.rapid7.com/disclosure/)."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access."
}
]
},
"exploit": [],
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78 (Improper Neutralization of Special Elements used in an OS Command)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553",
"refsource": "CONFIRM",
"url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553"
},
{
"name": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/",
"refsource": "MISC",
"url": "https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Users should update affected devices to the latest firmware version (1.3384.00059.001 or higher) available from Crestron\u0027s product pages."
}
],
"source": {
"advisory": "R7-2018-15",
"defect": [],
"discovery": "EXTERNAL"
},
"work_around": []
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2018-5553",
"datePublished": "2018-07-10T16:00:00Z",
"dateReserved": "2018-01-12T00:00:00",
"dateUpdated": "2024-09-16T22:20:46.752Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:crestron:dge-100_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.3384.00049.001\", \"matchCriteriaId\": \"2F48676D-D566-45C5-965B-B20ED8F2817F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:crestron:dge-100:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E5D6A6E8-4FF6-467F-8F59-5512DD5B0A2C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:crestron:dm-dge-200-c_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.3384.00049.001\", \"matchCriteriaId\": \"9D0D4D4C-9AE5-4500-8531-691E766A3175\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:crestron:dm-dge-200-c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D0D4FFAC-0D1F-4D58-986B-3F402EE643AE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:crestron:ts-1542-c_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.3384.00049.001\", \"matchCriteriaId\": \"8D4AA22E-4175-4B81-BC75-B88868785FD5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:crestron:ts-1542-c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B59A47EB-692A-47A0-B1CE-6967A18B7A37\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.\"}, {\"lang\": \"es\", \"value\": \"El servicio Crestron Console en los dispositivos DGE-100, DM-DGE-200-C y TS-1542-C con la configuraci\\u00f3n por defecto y ejecutando versiones del firmware 1.3384.00049.001 y anteriores es vulnerable a una inyecci\\u00f3n de comandos que puede emplearse para obtener acceso a nivel root.\"}]",
"id": "CVE-2018-5553",
"lastModified": "2024-11-21T04:09:03.720",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"cve@rapid7.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2018-07-10T16:29:00.970",
"references": "[{\"url\": \"https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/\", \"source\": \"cve@rapid7.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553\", \"source\": \"cve@rapid7.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@rapid7.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cve@rapid7.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-5553\",\"sourceIdentifier\":\"cve@rapid7.com\",\"published\":\"2018-07-10T16:29:00.970\",\"lastModified\":\"2024-11-21T04:09:03.720\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Crestron Console service running on DGE-100, DM-DGE-200-C, and TS-1542-C devices with default configuration and running firmware versions 1.3384.00049.001 and lower are vulnerable to command injection that can be used to gain root-level access.\"},{\"lang\":\"es\",\"value\":\"El servicio Crestron Console en los dispositivos DGE-100, DM-DGE-200-C y TS-1542-C con la configuraci\u00f3n por defecto y ejecutando versiones del firmware 1.3384.00049.001 y anteriores es vulnerable a una inyecci\u00f3n de comandos que puede emplearse para obtener acceso a nivel root.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cve@rapid7.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:dge-100_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.3384.00049.001\",\"matchCriteriaId\":\"2F48676D-D566-45C5-965B-B20ED8F2817F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:dge-100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5D6A6E8-4FF6-467F-8F59-5512DD5B0A2C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:dm-dge-200-c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.3384.00049.001\",\"matchCriteriaId\":\"9D0D4D4C-9AE5-4500-8531-691E766A3175\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:dm-dge-200-c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0D4FFAC-0D1F-4D58-986B-3F402EE643AE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:ts-1542-c_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.3384.00049.001\",\"matchCriteriaId\":\"8D4AA22E-4175-4B81-BC75-B88868785FD5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:ts-1542-c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B59A47EB-692A-47A0-B1CE-6967A18B7A37\"}]}]}],\"references\":[{\"url\":\"https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/\",\"source\":\"cve@rapid7.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553\",\"source\":\"cve@rapid7.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://blog.rapid7.com/2018/06/12/r7-2018-15-cve-2018-5553-crestron-dge-100-console-command-injection-fixed/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet#CVE%C2%AD-2018%C2%AD-5553\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…