Search criteria
9 vulnerabilities by GE Vernova
CVE-2025-3222 (GCVE-0-2025-3222)
Vulnerability from cvelistv5 – Published: 2025-11-07 16:28 – Updated: 2025-11-13 17:16
VLAI?
Summary
Improper Authentication vulnerability in GE Vernova Smallworld on Windows, Linux allows Authentication Abuse.This issue affects Smallworld: 5.3.3 and prior versions for Linux, and 5.3.4. and prior versions for Windows.
Severity ?
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GE Vernova | Smallworld |
Affected:
5.3.3
(Linux)
Affected: 5.3.4 (Windows) |
Credits
Théo GOBINET
Azaël MARTIN
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3222",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-07T19:17:06.399847Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-07T19:17:12.529Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"Linux"
],
"product": "Smallworld",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "5.3.3",
"versionType": "Linux"
},
{
"status": "affected",
"version": "5.3.4",
"versionType": "Windows"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Th\u00e9o GOBINET"
},
{
"lang": "en",
"type": "finder",
"value": "Aza\u00ebl MARTIN"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Authentication vulnerability in GE Vernova Smallworld on Windows, Linux allows Authentication Abuse.\u003cp\u003eThis issue affects Smallworld: 5.3.3 and prior versions for Linux, and 5.3.4. and prior versions for Windows.\u003c/p\u003e"
}
],
"value": "Improper Authentication vulnerability in GE Vernova Smallworld on Windows, Linux allows Authentication Abuse.This issue affects Smallworld: 5.3.3 and prior versions for Linux, and 5.3.4. and prior versions for Windows."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-13T17:16:35.591Z",
"orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"shortName": "GE_Vernova"
},
"references": [
{
"url": "https://www.gevernova.com/content/dam/cyber_security/global/en_US/pdfs/SecurityAdvisory_ImproperAuthentication_SWMFS.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "GE Vernova recommends that users upgrade to the appropriate non-affected version listed above in accordance with their use case and architecture as this is the most complete method to address the Vulnerability.\u003cbr\u003e\u003cbr\u003eAlso, users are strongly advised to follow the SDG instructions. The complete SDG can be found in the Smallworld Documentation.\u003cbr\u003e\u003cbr\u003eTo obtain the latest version of SWMFS, please contact your local support representative at Customer Center.\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "GE Vernova recommends that users upgrade to the appropriate non-affected version listed above in accordance with their use case and architecture as this is the most complete method to address the Vulnerability.\n\nAlso, users are strongly advised to follow the SDG instructions. The complete SDG can be found in the Smallworld Documentation.\n\nTo obtain the latest version of SWMFS, please contact your local support representative at Customer Center."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Smallworld SWMFS Improper Authentication",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"assignerShortName": "GE_Vernova",
"cveId": "CVE-2025-3222",
"datePublished": "2025-11-07T16:28:45.217Z",
"dateReserved": "2025-04-03T13:47:11.155Z",
"dateUpdated": "2025-11-13T17:16:35.591Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-7719 (GCVE-0-2025-7719)
Vulnerability from cvelistv5 – Published: 2025-11-07 16:28 – Updated: 2025-11-13 17:17
VLAI?
Summary
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in GE Vernova Smallworld on Windows, Linux allows File Manipulation.This issue affects Smallworld: 5.3.5. and previous versions.
Severity ?
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GE Vernova | Smallworld |
Affected:
5.3.5
|
Credits
Théo GOBINET
Azaël MARTIN
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-7719",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-11-07T19:17:36.891267Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-11-07T19:17:44.314Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows",
"Linux"
],
"product": "Smallworld",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "5.3.5"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Th\u00e9o GOBINET"
},
{
"lang": "en",
"type": "finder",
"value": "Aza\u00ebl MARTIN"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in GE Vernova Smallworld on Windows, Linux allows File Manipulation.\u003cp\u003eThis issue affects Smallworld: 5.3.5. and previous versions.\u003c/p\u003e"
}
],
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in GE Vernova Smallworld on Windows, Linux allows File Manipulation.This issue affects Smallworld: 5.3.5. and previous versions."
}
],
"impacts": [
{
"capecId": "CAPEC-165",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-165 File Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-13T17:17:12.293Z",
"orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"shortName": "GE_Vernova"
},
"references": [
{
"url": "https://www.gevernova.com/content/dam/cyber_security/global/en_US/pdfs/SecurityAdvisory_ArbitraryFileOps_SWMFS.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "GE Vernova recommends that users upgrade to the appropriate non-affected version listed above in accordance with their use case and architecture, as this is the most complete method to address the Vulnerability.\u003cbr\u003e\u003cbr\u003eAlso, users are strongly advised to follow the SDG instructions. The complete SDG can be found in the Smallworld Documentation.\u003cbr\u003e\u003cbr\u003eTo obtain the latest version of SWMFS, please contact your local support representative at Customer Center.\u003cbr\u003e"
}
],
"value": "GE Vernova recommends that users upgrade to the appropriate non-affected version listed above in accordance with their use case and architecture, as this is the most complete method to address the Vulnerability.\n\nAlso, users are strongly advised to follow the SDG instructions. The complete SDG can be found in the Smallworld Documentation.\n\nTo obtain the latest version of SWMFS, please contact your local support representative at Customer Center."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Smallworld SWMFS Arbitrary File Ops",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"assignerShortName": "GE_Vernova",
"cveId": "CVE-2025-7719",
"datePublished": "2025-11-07T16:28:03.432Z",
"dateReserved": "2025-07-16T16:37:57.358Z",
"dateUpdated": "2025-11-13T17:17:12.293Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-9038 (GCVE-0-2025-9038)
Vulnerability from cvelistv5 – Published: 2025-09-22 14:49 – Updated: 2025-09-24 13:31
VLAI?
Summary
Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version.
Severity ?
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GE Vernova | S1 Agile Configuration Software |
Affected:
3.1 and previous version
|
Credits
Charit Misra from DNV, Netherlands
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9038",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-22T16:54:16.367027Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-22T17:26:59.035Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "S1 Agile Configuration Software",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "3.1 and previous version"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Charit Misra from DNV, Netherlands"
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Privilege Management vulnerability in GE Vernova S1 Agile Configuration Software on Windows allows Privilege Escalation.This issue affects S1 Agile Configuration Software: 3.1 and previous version."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NEGLIGIBLE",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "LOCAL",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-24T13:31:23.806Z",
"orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"shortName": "GE_Vernova"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/sites/default/files/resources/products/support/ges-2025-001.pdf"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "To resolve this issue and enhance security, during the S1 Agile application installation, we ensure \nonly privileged users can access various folders used by the S1 Agile application. This ensures \nthat S1 Agile files can not be edited or replaced by users without sufficient privileges on that \ncomputer. \u003cbr\u003e\u003cbr\u003e\nWe would like to assert that this attack, if successful, can give \u201cAdministrator\u201d privileges to the \nattacker on the computer, but the configured IEDs will not see any impact in their configuration or \nfunctionality. The RBAC (\u2018Role-Based Access Control\u2019) on the IED remains unimpacted. \n\n\u003cbr\u003e\u003cbr\u003e\n\nWe strongly recommend customers to upgrade to the latest software version available. \nSoftware version 3.1.1 is released for customer usage in January 2025. \n\n\u003cbr\u003e"
}
],
"value": "To resolve this issue and enhance security, during the S1 Agile application installation, we ensure \nonly privileged users can access various folders used by the S1 Agile application. This ensures \nthat S1 Agile files can not be edited or replaced by users without sufficient privileges on that \ncomputer. \n\n\nWe would like to assert that this attack, if successful, can give \u201cAdministrator\u201d privileges to the \nattacker on the computer, but the configured IEDs will not see any impact in their configuration or \nfunctionality. The RBAC (\u2018Role-Based Access Control\u2019) on the IED remains unimpacted. \n\n\n\n\n\nWe strongly recommend customers to upgrade to the latest software version available. \nSoftware version 3.1.1 is released for customer usage in January 2025."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "S1 Agile Privilege Escalation",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "As a workaround, GE Vernova recommends having sufficient security controls in place on the \nworkstation where S1 Agile software is installed. This will ensure the attacker\u2019s remote \nconnection to the computer is not feasible. Harden the computer on which S1 Agile is installed. \nThe product deployment guide can be used to understand the guidelines around how the product \ncan be deployed in the end user\u2019s environment. \n\n\u003cbr\u003e"
}
],
"value": "As a workaround, GE Vernova recommends having sufficient security controls in place on the \nworkstation where S1 Agile software is installed. This will ensure the attacker\u2019s remote \nconnection to the computer is not feasible. Harden the computer on which S1 Agile is installed. \nThe product deployment guide can be used to understand the guidelines around how the product \ncan be deployed in the end user\u2019s environment."
}
],
"x_generator": {
"engine": "cveClient/1.0.15"
}
}
},
"cveMetadata": {
"assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"assignerShortName": "GE_Vernova",
"cveId": "CVE-2025-9038",
"datePublished": "2025-09-22T14:49:38.805Z",
"dateReserved": "2025-08-14T13:30:30.722Z",
"dateUpdated": "2025-09-24T13:31:23.806Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-3223 (GCVE-0-2025-3223)
Vulnerability from cvelistv5 – Published: 2025-05-19 21:03 – Updated: 2025-05-20 13:00
VLAI?
Summary
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in GE Vernova WorkstationST on Windows (EGD Configuration Server modules) allows Path Traversal.This issue affects WorkstationST: WorkstationST V07.10.10C and earlier.
Severity ?
5.9 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GE Vernova | WorkstationST |
Affected:
WorkstationST V07.10.10C and earlier
(Custom)
|
Credits
Ricardo Pelaz García
Roberto Garcia Hervás
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-3223",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-20T12:59:54.621643Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-20T13:00:02.792Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"EGD Configuration Server"
],
"platforms": [
"Windows"
],
"product": "WorkstationST",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "WorkstationST V07.10.10C and earlier",
"versionType": "Custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Ricardo Pelaz Garc\u00eda"
},
{
"lang": "en",
"type": "finder",
"value": "Roberto Garcia Herv\u00e1s"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in GE Vernova WorkstationST on Windows (EGD Configuration Server modules) allows Path Traversal.\u003cp\u003eThis issue affects WorkstationST: WorkstationST V07.10.10C and earlier.\u003c/p\u003e"
}
],
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in GE Vernova WorkstationST on Windows (EGD Configuration Server modules) allows Path Traversal.This issue affects WorkstationST: WorkstationST V07.10.10C and earlier."
}
],
"impacts": [
{
"capecId": "CAPEC-126",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-126 Path Traversal"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-19T21:03:32.078Z",
"orgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"shortName": "GE_Vernova"
},
"references": [
{
"url": "https://www.gevernova.com/content/dam/cyber_security/global/en_US/pdfs/2024-09-24_EGD_Config_Server_File_Overwrite.pdf"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "WorkstationST EGD Configuration Server Path Traversal Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2cf0fb33-79e2-44e0-beb8-826cc5ce3250",
"assignerShortName": "GE_Vernova",
"cveId": "CVE-2025-3223",
"datePublished": "2025-05-19T21:03:32.078Z",
"dateReserved": "2025-04-03T13:57:26.486Z",
"dateUpdated": "2025-05-20T13:00:02.792Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27257 (GCVE-0-2025-27257)
Vulnerability from cvelistv5 – Published: 2025-03-10 09:05 – Updated: 2025-03-12 11:10
VLAI?
Summary
Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware.
The firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration check to be bypassed.
Severity ?
6.1 (Medium)
CWE
- CWE-345 - Insufficient Verification of Data Authenticity
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GE Vernova | N60 multilin |
Affected:
7.0 , ≤ 8.60
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27257",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T13:23:04.580273Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T13:23:20.325Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "N60 multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "B30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "B90 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C70 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C95 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "D30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "D60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "F35 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "F60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L90 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "M60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "T35 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "T60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "M60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware.\u003cbr\u003eThe firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, a\u003cspan style=\"background-color: var(--wht);\"\u003ellowing the integration check to be bypassed.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Insufficient Verification of Data Authenticity vulnerability in GE Vernova UR IED family devices allows an authenticated user to install a modified firmware.\nThe firmware signature verification is enforced only on the client-side dedicated software Enervista UR Setup, allowing the integration check to be bypassed."
}
],
"impacts": [
{
"capecId": "CAPEC-638",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-638 Altered Component Firmware"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-345",
"description": "CWE-345 Insufficient Verification of Data Authenticity",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-12T11:10:57.902Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily\u0026type=21\u0026file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27257"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2025-27257",
"datePublished": "2025-03-10T09:05:34.817Z",
"dateReserved": "2025-02-21T08:32:26.974Z",
"dateUpdated": "2025-03-12T11:10:57.902Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27256 (GCVE-0-2025-27256)
Vulnerability from cvelistv5 – Published: 2025-03-10 09:05 – Updated: 2025-03-12 11:10
VLAI?
Summary
Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network.
Severity ?
8.3 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GE Vernova | EnerVista UR Setup |
Affected:
7.0 , ≤ 8.60
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27256",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T14:01:25.783083Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T14:01:42.394Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EnerVista UR Setup",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network."
}
],
"value": "Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-12T11:10:35.187Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily\u0026type=21\u0026file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27256"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2025-27256",
"datePublished": "2025-03-10T09:05:25.962Z",
"dateReserved": "2025-02-21T08:32:26.974Z",
"dateUpdated": "2025-03-12T11:10:35.187Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27255 (GCVE-0-2025-27255)
Vulnerability from cvelistv5 – Published: 2025-03-10 09:05 – Updated: 2025-03-12 11:10
VLAI?
Summary
Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code.
Severity ?
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GE Vernova | EnerVista UR Setup |
Affected:
8.42
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27255",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T14:02:30.485876Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T14:03:06.938Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EnerVista UR Setup",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "8.42",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code."
}
],
"value": "Use of Hard-coded Credentials vulnerability in GE Vernova EnerVista UR Setup allows Privilege Escalation. The local user database is encrypted using an hardcoded password retrievable by an attacker analyzing the application code."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-12T11:10:21.030Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily\u0026type=21\u0026file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27255"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2025-27255",
"datePublished": "2025-03-10T09:05:17.222Z",
"dateReserved": "2025-02-21T08:32:26.973Z",
"dateUpdated": "2025-03-12T11:10:21.030Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27254 (GCVE-0-2025-27254)
Vulnerability from cvelistv5 – Published: 2025-03-10 09:05 – Updated: 2025-10-07 14:18
VLAI?
Summary
CWE-282 "Improper Ownership Management" in GE Vernova EnerVista UR Setup allows Authentication Bypass.
The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify.
Severity ?
CWE
- CWE-282 - Improper Ownership Management
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| GE Vernova | EnerVista UR Setup |
Affected:
8.42
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27254",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T14:10:30.949201Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T14:10:54.966Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EnerVista UR Setup",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "8.42",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-282 \"Improper Ownership Management\"\u0026nbsp;in GE Vernova EnerVista UR Setup allows Authentication Bypass.\u0026nbsp;\u003cbr\u003e\u003cspan style=\"background-color: var(--wht);\"\u003eThe software\u0027s startup authentication can be disabled by altering a Windows registry setting that any user can modify.\u003c/span\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "CWE-282 \"Improper Ownership Management\"\u00a0in GE Vernova EnerVista UR Setup allows Authentication Bypass.\u00a0\nThe software\u0027s startup authentication can be disabled by altering a Windows registry setting that any user can modify."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-282",
"description": "CWE-282 Improper Ownership Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T14:18:35.592Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily\u0026type=21\u0026file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27254"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2025-27254",
"datePublished": "2025-03-10T09:05:08.963Z",
"dateReserved": "2025-02-21T08:32:26.973Z",
"dateUpdated": "2025-10-07T14:18:35.592Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-27253 (GCVE-0-2025-27253)
Vulnerability from cvelistv5 – Published: 2025-03-10 09:04 – Updated: 2025-10-07 14:16
VLAI?
Summary
A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.
Severity ?
6.1 (Medium)
CWE
- CWE-15 - External Control of System or Configuration Setting
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GE Vernova | N60 multilin |
Affected:
7.0 , ≤ 8.60
(custom)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-27253",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-10T15:33:39.489617Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-10T15:33:49.185Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "N60 multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "B30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "B90 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C70 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C95 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "D30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "D60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "F35 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "F60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L90 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "M60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "T35 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "T60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "M60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\u0026nbsp;CWE-15 \"External Control of System or Configuration Setting\"\u0026nbsp;in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
}
],
"value": "A\u00a0CWE-15 \"External Control of System or Configuration Setting\"\u00a0in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-15",
"description": "CWE-15 External Control of System or Configuration Setting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T14:16:49.710Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily\u0026type=21\u0026file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27253"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2025-27253",
"datePublished": "2025-03-10T09:04:34.413Z",
"dateReserved": "2025-02-21T08:32:26.973Z",
"dateUpdated": "2025-10-07T14:16:49.710Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",