Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    8 vulnerabilities by Group Arge Energy and Control Systems

    CVE-2022-4557 (GCVE-0-2022-4557)

    Vulnerability from cvelistv5 – Published: 2023-02-09 10:50 – Updated: 2026-05-18 14:24
    VLAI
    Title
    SQL Injection in Smartpower Web
    Summary
    Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection. This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    References
    Impacted products
    Date Public
    2023-02-08 11:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:41:45.723Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-4557",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T17:49:39.290531Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T18:30:49.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2023-02-08T11:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:24:25.998Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "SQL Injection in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-4557",
        "datePublished": "2023-02-09T10:50:03.914Z",
        "dateReserved": "2022-12-16T14:16:49.490Z",
        "dateUpdated": "2026-05-18T14:24:25.998Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45091 (GCVE-0-2022-45091)

    Vulnerability from cvelistv5 – Published: 2023-02-08 19:27 – Updated: 2026-05-18 14:39
    VLAI
    Title
    Cross-site Scripting in Smartpower Web
    Summary
    Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.452Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45091",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T19:11:41.039766Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T19:11:45.416Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
                }
              ],
              "value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\n\nThis issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:39:27.356Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE ID reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "Cross-site Scripting in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45091",
        "datePublished": "2023-02-08T19:27:17.083Z",
        "dateReserved": "2022-11-09T13:35:23.470Z",
        "dateUpdated": "2026-05-18T14:39:27.356Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45090 (GCVE-0-2022-45090)

    Vulnerability from cvelistv5 – Published: 2023-02-08 19:21 – Updated: 2026-05-18 14:37
    VLAI
    Title
    SQL Injection in Smartpower Web
    Summary
    Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection. This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    References
    Impacted products
    Credits
    Furkan KUTLUCA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.531Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45090",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T19:12:09.543713Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T19:38:34.511Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Furkan KUTLUCA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
                }
              ],
              "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:37:25.895Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE ID reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "SQL Injection in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45090",
        "datePublished": "2023-02-08T19:21:32.092Z",
        "dateReserved": "2022-11-09T13:35:23.470Z",
        "dateUpdated": "2026-05-18T14:37:25.895Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45089 (GCVE-0-2022-45089)

    Vulnerability from cvelistv5 – Published: 2023-02-08 19:18 – Updated: 2026-05-18 14:34
    VLAI
    Title
    SQL Injection in Smartpower Web
    Summary
    Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection. This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
    Assigner
    References
    Impacted products
    Credits
    Furkan KUTLUCA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.544Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45089",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T19:47:47.485436Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T19:47:53.654Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Furkan KUTLUCA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
                }
              ],
              "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows SQL Injection.\n\nThis issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:34:40.076Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE ID reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "SQL Injection in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45089",
        "datePublished": "2023-02-08T19:18:52.229Z",
        "dateReserved": "2022-11-09T13:35:23.470Z",
        "dateUpdated": "2026-05-18T14:34:40.076Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45088 (GCVE-0-2022-45088)

    Vulnerability from cvelistv5 – Published: 2023-02-08 18:50 – Updated: 2026-05-18 14:29
    VLAI
    Title
    Local File Inclusion in Smartpower Web
    Summary
    Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion. This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.505Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45088",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-24T19:48:08.787560Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-24T19:48:12.760Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
                }
              ],
              "value": "Improper Input Validation vulnerability in Group Arge Energy and Control Systems Smartpower Web allows PHP Local File Inclusion.\n\nThis issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-252",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-252 PHP Local File Inclusion"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:29:59.468Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE ID reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "Local File Inclusion in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45088",
        "datePublished": "2023-02-08T18:50:07.000Z",
        "dateReserved": "2022-11-09T13:35:23.470Z",
        "dateUpdated": "2026-05-18T14:29:59.468Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45087 (GCVE-0-2022-45087)

    Vulnerability from cvelistv5 – Published: 2023-02-08 18:46 – Updated: 2026-05-18 14:28
    VLAI
    Title
    Cross-site Scripting in Smartpower Web
    Summary
    Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.477Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45087",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-25T13:52:32.590384Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-25T13:52:39.650Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u0026nbsp;\u003cspan\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/span\u003e"
                }
              ],
              "value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:28:07.274Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE ID reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "Cross-site Scripting in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45087",
        "datePublished": "2023-02-08T18:46:13.951Z",
        "dateReserved": "2022-11-09T13:35:23.470Z",
        "dateUpdated": "2026-05-18T14:28:07.274Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45086 (GCVE-0-2022-45086)

    Vulnerability from cvelistv5 – Published: 2023-02-08 18:27 – Updated: 2026-05-18 14:42
    VLAI
    Title
    Cross-site Scripting in Smartpower Web
    Summary
    Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS). This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Credits
    Furkan KUTLUCA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.527Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45086",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-25T13:53:26.674714Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-25T13:53:35.194Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Furkan KUTLUCA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u0026nbsp;\u003cspan\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/span\u003e"
                }
              ],
              "value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows Cross-Site Scripting (XSS).\u00a0This issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:42:36.302Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE ID reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "Cross-site Scripting in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45086",
        "datePublished": "2023-02-08T18:27:15.888Z",
        "dateReserved": "2022-11-09T13:35:23.469Z",
        "dateUpdated": "2026-05-18T14:42:36.302Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-45085 (GCVE-0-2022-45085)

    Vulnerability from cvelistv5 – Published: 2023-02-08 14:48 – Updated: 2026-05-18 14:40
    VLAI
    Title
    Server-Side Request Forgery in Smartpower Web
    Summary
    Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery. This issue affects Smartpower Web: before 23.01.01.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-918 - Server-Side Request Forgery (SSRF)
    Assigner
    References
    Impacted products
    Credits
    Furkan KUTLUCA
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:01:31.453Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45085",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-25T13:57:20.371683Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-25T13:57:29.774Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Smartpower Web",
              "vendor": "Group Arge Energy and Control Systems",
              "versions": [
                {
                  "lessThan": "23.01.01",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Furkan KUTLUCA"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.\u003cp\u003eThis issue affects Smartpower Web: before 23.01.01.\u003c/p\u003e"
                }
              ],
              "value": "Server-Side Request Forgery (SSRF) vulnerability in Group Arge Energy and Control Systems Smartpower Web allows : Server Side Request Forgery.\n\nThis issue affects Smartpower Web: before 23.01.01."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-664",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-664 Server Side Request Forgery"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-918",
                  "description": "CWE-918 Server-Side Request Forgery (SSRF)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-18T14:40:49.577Z",
            "orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
            "shortName": "TR-CERT"
          },
          "references": [
            {
              "tags": [
                "government-resource",
                "broken-link"
              ],
              "url": "https://www.usom.gov.tr/bildirim/tr-23-0066"
            },
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://siberguvenlik.gov.tr/guvenlik-bildirimleri/detay/tr-23-0066"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update the software to \u0026gt;= 23.01.01"
                }
              ],
              "value": "Update the software to \u003e= 23.01.01"
            }
          ],
          "source": {
            "advisory": "TR-23-0066",
            "defect": [
              "TR-23-0066"
            ],
            "discovery": "EXTERNAL"
          },
          "timeline": [
            {
              "lang": "en",
              "time": "2022-11-08T14:44:00.000Z",
              "value": "Vulnerability detected"
            },
            {
              "lang": "en",
              "time": "2022-11-09T10:35:00.000Z",
              "value": "CVE reservation"
            },
            {
              "lang": "en",
              "time": "2022-11-09T12:00:00.000Z",
              "value": "Vendor informed"
            },
            {
              "lang": "en",
              "time": "2023-01-01T10:00:00.000Z",
              "value": "Patch published by vendor"
            },
            {
              "lang": "en",
              "time": "2023-02-08T13:00:00.000Z",
              "value": "Government advisory published"
            },
            {
              "lang": "en",
              "time": "2023-02-08T14:50:00.000Z",
              "value": "CVE published"
            }
          ],
          "title": "Server-Side Request Forgery in Smartpower Web",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
        "assignerShortName": "TR-CERT",
        "cveId": "CVE-2022-45085",
        "datePublished": "2023-02-08T14:48:27.782Z",
        "dateReserved": "2022-11-09T13:35:23.469Z",
        "dateUpdated": "2026-05-18T14:40:49.577Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }