CVE-2025-8834 (GCVE-0-2025-8834)
Vulnerability from cvelistv5 – Published: 2025-08-11 06:32 – Updated: 2025-08-12 14:19
VLAI?
Title
JCG Link-net LW-N915R Wireless Basic Settings basic.asp cross site scripting
Summary
A vulnerability has been found in JCG Link-net LW-N915R 17s.20.001.908. Affected is an unknown function of the file /wireless/basic.asp of the component Wireless Basic Settings Page. The manipulation of the argument Network Name leads to cross site scripting. It is possible to launch the attack remotely.
Severity ?
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| JCG | Link-net LW-N915R |
Affected:
17s.20.001.908
|
Credits
Fergod (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-8834",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-11T15:15:11.150374Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T14:19:31.832Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless Basic Settings Page"
],
"product": "Link-net LW-N915R",
"vendor": "JCG",
"versions": [
{
"status": "affected",
"version": "17s.20.001.908"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Fergod (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in JCG Link-net LW-N915R 17s.20.001.908. Affected is an unknown function of the file /wireless/basic.asp of the component Wireless Basic Settings Page. The manipulation of the argument Network Name leads to cross site scripting. It is possible to launch the attack remotely."
},
{
"lang": "de",
"value": "Dabei betrifft es einen unbekannter Codeteil der Datei /wireless/basic.asp der Komponente Wireless Basic Settings Page. Mittels dem Manipulieren des Arguments Network Name mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-11T06:32:06.665Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-319368 | JCG Link-net LW-N915R Wireless Basic Settings basic.asp cross site scripting",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.319368"
},
{
"name": "VDB-319368 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.319368"
},
{
"name": "Submit #627228 | Link-net LW-N915R 17s.20.001.908 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.627228"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-08-10T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-08-10T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-08-10T10:20:40.000Z",
"value": "VulDB entry last update"
}
],
"title": "JCG Link-net LW-N915R Wireless Basic Settings basic.asp cross site scripting"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-8834",
"datePublished": "2025-08-11T06:32:06.665Z",
"dateReserved": "2025-08-10T08:15:37.447Z",
"dateUpdated": "2025-08-12T14:19:31.832Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}