Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    3 vulnerabilities by METIS Cyberspace Technology SA

    CVE-2026-2249 (GCVE-0-2026-2249)

    Vulnerability from cvelistv5 – Published: 2026-02-11 14:16 – Updated: 2026-02-12 15:20
    VLAI
    Title
    Unauthenticated Remote Command Execution via Web Console in METIS DFS
    Summary
    METIS DFS devices (versions <= oscore 2.1.234-r18) expose a web-based shell at the /console endpoint that does not require authentication. Accessing this endpoint allows a remote attacker to execute arbitrary operating system commands with 'daemon' privileges. This results in the compromise of the software, granting unauthorized access to modify configuration, read and alter sensitive data, or disrupt services.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    • CWE-287 - Improper Authentication
    Assigner
    MHV
    References
    URL Tags
    https://www.metis.tech/ x_vendor-website
    https://cydome.io/vulnerability-advisory-cve-2026… technical-description
    Impacted products
    Vendor Product Version
    METIS Cyberspace Technology SA METIS DFS Affected: oscore 2.1.234-r18 (custom)
    Unaffected: oscore 2.1.235-r19 (custom)
    Create a notification for this product.
    Credits
    Cydome Security Ltd
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2249",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-11T14:47:17.943059Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-11T14:48:28.435Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "METIS DFS",
              "vendor": "METIS Cyberspace Technology SA",
              "versions": [
                {
                  "status": "affected",
                  "version": "oscore 2.1.234-r18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "oscore 2.1.235-r19",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Cydome Security Ltd"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eMETIS DFS devices (versions \u0026lt;= oscore 2.1.234-r18) expose a web-based shell at the /console endpoint that does not require authentication. Accessing this endpoint allows a remote attacker to execute arbitrary operating system commands with \u0027daemon\u0027 privileges. This results in the compromise of the software, granting unauthorized access to modify configuration, read and alter sensitive data, or disrupt services.\u003c/p\u003e"
                }
              ],
              "value": "METIS DFS devices (versions \u003c= oscore 2.1.234-r18) expose a web-based shell at the /console endpoint that does not require authentication. Accessing this endpoint allows a remote attacker to execute arbitrary operating system commands with \u0027daemon\u0027 privileges. This results in the compromise of the software, granting unauthorized access to modify configuration, read and alter sensitive data, or disrupt services."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-12T15:20:28.314Z",
            "orgId": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
            "shortName": "MHV"
          },
          "references": [
            {
              "tags": [
                "x_vendor-website"
              ],
              "url": "https://www.metis.tech/"
            },
            {
              "tags": [
                "technical-description"
              ],
              "url": "https://cydome.io/vulnerability-advisory-cve-2026-2249-unauthenticated-rce-in-metis-data-fusion-server-dfs"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Unauthenticated Remote Command Execution via Web Console in METIS DFS",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
        "assignerShortName": "MHV",
        "cveId": "CVE-2026-2249",
        "datePublished": "2026-02-11T14:16:19.157Z",
        "dateReserved": "2026-02-09T13:38:43.331Z",
        "dateUpdated": "2026-02-12T15:20:28.314Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2248 (GCVE-0-2026-2248)

    Vulnerability from cvelistv5 – Published: 2026-02-11 14:15 – Updated: 2026-02-12 15:20
    VLAI
    Title
    Unauthenticated Remote Root Shell Access via Web Console in METIS WIC
    Summary
    METIS WIC devices (versions <= oscore 2.1.234-r18) expose a web-based shell at the /console endpoint that does not require authentication. Accessing this endpoint allows a remote attacker to execute arbitrary operating system commands with root (UID 0) privileges. This results in full system compromise, allowing unauthorized access to modify system configuration, read sensitive data, or disrupt device operations
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    • CWE-287 - Improper Authentication
    Assigner
    MHV
    References
    URL Tags
    https://www.metis.tech/ x_vendor-website
    https://cydome.io/vulnerability-advisory-cve-2026… technical-description
    Impacted products
    Vendor Product Version
    METIS Cyberspace Technology SA METIS WIC Affected: oscore 2.1.234-r18 (custom)
    Unaffected: oscore 2.1.235-r19 (custom)
    Create a notification for this product.
    Credits
    Cydome Security Ltd
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2248",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-11T14:54:21.293377Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-11T14:54:45.412Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "METIS WIC",
              "vendor": "METIS Cyberspace Technology SA",
              "versions": [
                {
                  "status": "affected",
                  "version": "oscore 2.1.234-r18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "oscore 2.1.235-r19",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Cydome Security Ltd"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eMETIS WIC devices (versions \u0026lt;= oscore 2.1.234-r18) expose a web-based shell at the /console endpoint that does not require authentication. Accessing this endpoint allows a remote attacker to execute arbitrary operating system commands with root (UID 0) privileges. This results in full system compromise, allowing unauthorized access to modify system configuration, read sensitive data, or disrupt device operations\u003cbr\u003e\u003c/p\u003e"
                }
              ],
              "value": "METIS WIC devices (versions \u003c= oscore 2.1.234-r18) expose a web-based shell at the /console endpoint that does not require authentication. Accessing this endpoint allows a remote attacker to execute arbitrary operating system commands with root (UID 0) privileges. This results in full system compromise, allowing unauthorized access to modify system configuration, read sensitive data, or disrupt device operations"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-12T15:20:05.979Z",
            "orgId": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
            "shortName": "MHV"
          },
          "references": [
            {
              "tags": [
                "x_vendor-website"
              ],
              "url": "https://www.metis.tech/"
            },
            {
              "tags": [
                "technical-description"
              ],
              "url": "https://cydome.io/vulnerability-advisory-cve-2026-2248-unauthenticated-remote-root-shell-in-metis-wic"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Unauthenticated Remote Root Shell Access via Web Console in METIS WIC",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
        "assignerShortName": "MHV",
        "cveId": "CVE-2026-2248",
        "datePublished": "2026-02-11T14:15:42.961Z",
        "dateReserved": "2026-02-09T13:38:41.942Z",
        "dateUpdated": "2026-02-12T15:20:05.979Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-2250 (GCVE-0-2026-2250)

    Vulnerability from cvelistv5 – Published: 2026-02-11 14:13 – Updated: 2026-02-12 15:20
    VLAI
    Title
    Unauthenticated Data Export and Source Code Disclosure via /dbviewer/ in METIS WIC
    Summary
    The /dbviewer/ web endpoint in METIS WIC devices is exposed without authentication. A remote attacker can access and export the internal telemetry SQLite database containing sensitive operational data. Additionally, the application is configured with debug mode enabled, causing malformed requests to return verbose Django tracebacks that disclose backend source code, local file paths, and system configuration.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-284 - Improper Access Control
    • CWE-215 - Insertion of Sensitive Information Into Debugging Error Output
    Assigner
    MHV
    References
    URL Tags
    https://www.metis.tech/ x_vendor-website
    https://cydome.io/vulnerability-advisory-cve-2026… technical-description
    Impacted products
    Vendor Product Version
    METIS Cyberspace Technology SA METIS WIC Affected: oscore 2.1.234-r18 (custom)
    Unaffected: oscore 2.1.235-r19 (custom)
    Create a notification for this product.
    Credits
    Cydome Security Ltd
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-2250",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-02-11T15:00:06.523607Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-02-11T15:02:05.830Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "METIS WIC",
              "vendor": "METIS Cyberspace Technology SA",
              "versions": [
                {
                  "status": "affected",
                  "version": "oscore 2.1.234-r18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "oscore 2.1.235-r19",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Cydome Security Ltd"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThe /dbviewer/ web endpoint in METIS WIC devices is exposed without authentication. A remote attacker can access and export the internal telemetry SQLite database containing sensitive operational data. Additionally, the application is configured with debug mode enabled, causing malformed requests to return verbose Django tracebacks that disclose backend source code, local file paths, and system configuration.\u003c/p\u003e"
                }
              ],
              "value": "The /dbviewer/ web endpoint in METIS WIC devices is exposed without authentication. A remote attacker can access and export the internal telemetry SQLite database containing sensitive operational data. Additionally, the application is configured with debug mode enabled, causing malformed requests to return verbose Django tracebacks that disclose backend source code, local file paths, and system configuration."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284 Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-215",
                  "description": "CWE-215 Insertion of Sensitive Information Into Debugging Error Output",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-12T15:20:51.492Z",
            "orgId": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
            "shortName": "MHV"
          },
          "references": [
            {
              "tags": [
                "x_vendor-website"
              ],
              "url": "https://www.metis.tech/"
            },
            {
              "tags": [
                "technical-description"
              ],
              "url": "https://cydome.io/vulnerability-advisory-cve-2026-2250-unauthenticated-data-exfilteration-and-information-disclosure-in-metis-wic-wireless-intelligent-collector"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Unauthenticated Data Export and Source Code Disclosure via /dbviewer/ in METIS WIC",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "56a186b1-7f5e-4314-ba38-38d5499fccfd",
        "assignerShortName": "MHV",
        "cveId": "CVE-2026-2250",
        "datePublished": "2026-02-11T14:13:45.892Z",
        "dateReserved": "2026-02-09T13:38:44.756Z",
        "dateUpdated": "2026-02-12T15:20:51.492Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }