Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
4 vulnerabilities by Signify
CVE-2026-73669 (GCVE-0-2026-73669)
Vulnerability from nvd – Published: 2026-08-13 19:00 – Updated: 2026-08-13 19:00
VLAI
EPSS
VEX
Title
Philips Hue Bridge Pro MQTT broker missing authentication
Summary
The Signify Philips Hue Bridge Pro firmware embeds a Mosquitto MQTT broker (v2.0.22) that listens on all network interfaces with anonymous access enabled and no firewall restriction. An attacker with access to the Bridge's network can read device data and control connected lights.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · cisa-cg (v2.0.3)
Decision recorded 2026-08-03 18:41 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.philips-hue.com/en-us/support/release… | |
| https://www.philips-hue.com/en-us/support/securit… | release-notes |
| https://www.cve.org/CVERecord?id=CVE-2026-73669 | vdb-entry |
| https://raw.githubusercontent.com/cisagov/CSAF/de… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Signify | Philips Hue Bridge Pro |
Affected:
0 , < 1.77.2071318010
(custom)
Unaffected: 1.77.2071318010 |
Date Public
2026-08-13 00:00
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Philips Hue Bridge Pro",
"vendor": "Signify",
"versions": [
{
"lessThan": "1.77.2071318010",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.77.2071318010"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Bu\u011frahan KARAHAN"
}
],
"datePublic": "2026-08-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Signify Philips Hue Bridge Pro firmware embeds a Mosquitto MQTT broker (v2.0.22) that listens on all network interfaces with anonymous access enabled and no firewall restriction. An attacker with access to the Bridge\u0027s network can read device data and control connected lights."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW"
}
},
{
"other": {
"content": {
"id": "CVE-2026-73669",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-03T18:41:49.130933Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-13T19:00:05.705Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.philips-hue.com/en-us/support/release-notes/bridge-pro"
},
{
"name": "url",
"tags": [
"release-notes"
],
"url": "https://www.philips-hue.com/en-us/support/security-advisory"
},
{
"name": "url",
"tags": [
"vdb-entry"
],
"url": "https://www.cve.org/CVERecord?id=CVE-2026-73669"
},
{
"name": "url",
"tags": [
"third-party-advisory"
],
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/IT/white/2026/va-26-225-01.json"
}
],
"title": "Philips Hue Bridge Pro MQTT broker missing authentication"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2026-73669",
"datePublished": "2026-08-13T19:00:05.705Z",
"dateReserved": "2026-08-13T14:20:28.541Z",
"dateUpdated": "2026-08-13T19:00:05.705Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56562 (GCVE-0-2025-56562)
Vulnerability from nvd – Published: 2025-09-16 00:00 – Updated: 2026-07-05 16:09
VLAI
EPSS
VEX
Summary
An incorrect API discovered in Signify Wiz Connected 1.9.1 allows attackers to remotely launch a DoS on Wiz devices only requiring the MAC address.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-17 15:40 UTC
CWE
- n/a
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
2 references
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56562",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-17T15:40:10.715665Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-17T15:42:46.840Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://archive.org/details/wiz-rtebug"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An incorrect API discovered in Signify Wiz Connected 1.9.1 allows attackers to remotely launch a DoS on Wiz devices only requiring the MAC address."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T16:09:13.688Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://api.wiz.world/api/v2/light"
},
{
"url": "https://archive.org/details/wiz-rtebug"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56562",
"datePublished": "2025-09-16T00:00:00.000Z",
"dateReserved": "2025-08-17T00:00:00.000Z",
"dateUpdated": "2026-07-05T16:09:13.688Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-73669 (GCVE-0-2026-73669)
Vulnerability from cvelistv5 – Published: 2026-08-13 19:00 – Updated: 2026-08-13 19:00
VLAI
EPSS
VEX
Title
Philips Hue Bridge Pro MQTT broker missing authentication
Summary
The Signify Philips Hue Bridge Pro firmware embeds a Mosquitto MQTT broker (v2.0.22) that listens on all network interfaces with anonymous access enabled and no firewall restriction. An attacker with access to the Bridge's network can read device data and control connected lights.
Severity
6.3 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · cisa-cg (v2.0.3)
Decision recorded 2026-08-03 18:41 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
4 references
| URL | Tags |
|---|---|
| https://www.philips-hue.com/en-us/support/release… | |
| https://www.philips-hue.com/en-us/support/securit… | release-notes |
| https://www.cve.org/CVERecord?id=CVE-2026-73669 | vdb-entry |
| https://raw.githubusercontent.com/cisagov/CSAF/de… | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Signify | Philips Hue Bridge Pro |
Affected:
0 , < 1.77.2071318010
(custom)
Unaffected: 1.77.2071318010 |
Date Public
2026-08-13 00:00
{
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Philips Hue Bridge Pro",
"vendor": "Signify",
"versions": [
{
"lessThan": "1.77.2071318010",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "1.77.2071318010"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Bu\u011frahan KARAHAN"
}
],
"datePublic": "2026-08-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The Signify Philips Hue Bridge Pro firmware embeds a Mosquitto MQTT broker (v2.0.22) that listens on all network interfaces with anonymous access enabled and no firewall restriction. An attacker with access to the Bridge\u0027s network can read device data and control connected lights."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW"
}
},
{
"other": {
"content": {
"id": "CVE-2026-73669",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-08-03T18:41:49.130933Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-13T19:00:05.705Z",
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg"
},
"references": [
{
"name": "url",
"url": "https://www.philips-hue.com/en-us/support/release-notes/bridge-pro"
},
{
"name": "url",
"tags": [
"release-notes"
],
"url": "https://www.philips-hue.com/en-us/support/security-advisory"
},
{
"name": "url",
"tags": [
"vdb-entry"
],
"url": "https://www.cve.org/CVERecord?id=CVE-2026-73669"
},
{
"name": "url",
"tags": [
"third-party-advisory"
],
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/IT/white/2026/va-26-225-01.json"
}
],
"title": "Philips Hue Bridge Pro MQTT broker missing authentication"
}
},
"cveMetadata": {
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"assignerShortName": "cisa-cg",
"cveId": "CVE-2026-73669",
"datePublished": "2026-08-13T19:00:05.705Z",
"dateReserved": "2026-08-13T14:20:28.541Z",
"dateUpdated": "2026-08-13T19:00:05.705Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-56562 (GCVE-0-2025-56562)
Vulnerability from cvelistv5 – Published: 2025-09-16 00:00 – Updated: 2026-07-05 16:09
VLAI
EPSS
VEX
Summary
An incorrect API discovered in Signify Wiz Connected 1.9.1 allows attackers to remotely launch a DoS on Wiz devices only requiring the MAC address.
Severity
7.5 (High)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-17 15:40 UTC
CWE
- n/a
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
2 references
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56562",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-17T15:40:10.715665Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-17T15:42:46.840Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://archive.org/details/wiz-rtebug"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An incorrect API discovered in Signify Wiz Connected 1.9.1 allows attackers to remotely launch a DoS on Wiz devices only requiring the MAC address."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-05T16:09:13.688Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://api.wiz.world/api/v2/light"
},
{
"url": "https://archive.org/details/wiz-rtebug"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56562",
"datePublished": "2025-09-16T00:00:00.000Z",
"dateReserved": "2025-08-17T00:00:00.000Z",
"dateUpdated": "2026-07-05T16:09:13.688Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}