Search criteria
1 vulnerability by carestream
CVE-2018-17891 (GCVE-0-2018-17891)
Vulnerability from cvelistv5 – Published: 2018-10-04 21:00 – Updated: 2024-09-17 02:32
VLAI?
Summary
Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack.
Severity ?
No CVSS data available.
CWE
- CWE-209 - INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Carestream | Vue RIS |
Affected:
RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T11:01:14.459Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Vue RIS",
"vendor": "Carestream",
"versions": [
{
"status": "affected",
"version": "RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5"
}
]
}
],
"datePublic": "2018-10-04T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-04T20:57:01",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-10-04T00:00:00",
"ID": "CVE-2018-17891",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Vue RIS",
"version": {
"version_data": [
{
"version_value": "RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5"
}
]
}
}
]
},
"vendor_name": "Carestream"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Carestream Vue RIS, RIS Client Builds: Version 11.2 and prior running on a Windows 8.1 machine with IIS/7.5. When contacting a Carestream server where there is no Oracle TNS listener available, users will trigger an HTTP 500 error, leaking technical information an attacker could use to initiate a more elaborate attack."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "INFORMATION EXPOSURE THROUGH AN ERROR MESSAGE CWE-209"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSMA-18-277-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-17891",
"datePublished": "2018-10-04T21:00:00Z",
"dateReserved": "2018-10-02T00:00:00",
"dateUpdated": "2024-09-17T02:32:31.321Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}