Search

Find a vulnerability

Search criteria ⓘ Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    10 vulnerabilities by thermofisher

    CVE-2026-17583 (GCVE-0-2026-17583)

    Vulnerability from nvd – Published: 2026-08-05 20:23 – Updated: 2026-08-06 13:34
    VLAI
    Title
    Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check
    Summary
    The affected Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-06 13:34 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-17583",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-06T13:34:47.788856Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-06T13:34:57.240Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems 3500/3500xL Series Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "4.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems 3730/3730xL Series Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems SeqStudio Flex Series Instrument Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems GeneMapper ID-X Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "1.7.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems 3130 Series Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ABI PRISM 3100/3100-Avant Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ABI PRISM 310 Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Nathaniel Adams, Laura Gaydosh-Combs, and Kevin Dyer reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eThe affected\u003c/span\u003e\n\nThermo Fisher Applied Biosystems Genetic Analyzers are\u003cspan\u003e\u0026nbsp;vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.\u003c/span\u003e"
                }
              ],
              "value": "The affected\n\nThermo Fisher Applied Biosystems Genetic Analyzers are\u00a0vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-353",
                  "description": "CWE-353",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-05T20:23:32.890Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01"
            },
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2026-17583"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThermo Fisher has developed security updates to address the vulnerability. The security updates implement the use of digital signatures on the instrument software that adds an extralayer of protection. Moving forward, this will help users verify that data files have not been modified.\u003c/p\u003e\u003cp\u003eApplied Biosystems 3500/3500xL Series Data Collection Software: Update to version 4.0.3\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe\"\u003ehttps://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems 3730/3730xL Series Data Collection Software: Update to version 5.0.3\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe\"\u003ehttps://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems SeqStudio Genetic Analyzer Data Collection Software: Update to version 1.2.6\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg\"\u003ehttps://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems SeqStudio Flex Series Instrument Software: Update to version 1.2.1\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg\"\u003ehttps://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems GeneMapper ID-X Software: Update to version 1.7.4\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe\"\u003ehttps://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Thermo Fisher has developed security updates to address the vulnerability. The security updates implement the use of digital signatures on the instrument software that adds an extralayer of protection. Moving forward, this will help users verify that data files have not been modified.\n\n\n\nApplied Biosystems 3500/3500xL Series Data Collection Software: Update to version 4.0.3\n https://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe \n\n\n\nApplied Biosystems 3730/3730xL Series Data Collection Software: Update to version 5.0.3\n https://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe \n\n\n\nApplied Biosystems SeqStudio Genetic Analyzer Data Collection Software: Update to version 1.2.6\n https://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg \n\n\n\nApplied Biosystems SeqStudio Flex Series Instrument Software: Update to version 1.2.1\n https://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg \n\n\n\nApplied Biosystems GeneMapper ID-X Software: Update to version 1.7.4\n https://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe"
            }
          ],
          "source": {
            "advisory": "ICSMA-26-216-01",
            "discovery": "EXTERNAL"
          },
          "title": "Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eApplied Biosystems 3130 Series Data Collection Software: Product is End of Life (EoL), no update provided\u003cbr\u003eABI PRISM 3100/3100-Avant Data Collection Software: Product is End of Life (EoL), no update provided\u003cbr\u003eABI PRISM 310 Data Collection Software: Product is End of Life (EoL), no update provided\u003c/p\u003e\u003cp\u003eFor users who are unable to immediately implement all applicable security updates, Thermo Fisher Scientific recommends implementing the following interim mitigation measures until the applicable updates have been installed:\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003eMaintain a secure chain of custody for files generated by the HID instrumentation throughout the analysis workflow.\u003c/li\u003e\u003cli\u003eStore generated files on encrypted, password-protected storage media (for example, encrypted USB drives or encrypted hard drives).\u003c/li\u003e\u003cli\u003eRestrict access to generated files to authorized personnel in accordance with your laboratory\u0027s access control policies.\u003c/li\u003e\u003cli\u003eApply the principle of least privilege by limiting user permissions on systems operating the HID instrumentation or hosting associated data analysis and secondary analysis software.\u003c/li\u003e\u003cli\u003eLeverage firewall rules and network access control lists (NACLs) to restrict internet connectivity to only trusted sources.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information, refer to Thermo Fisher\u0027s security bulletin.\u003cbr\u003e\u003ca href=\"https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf\"\u003ehttps://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Applied Biosystems 3130 Series Data Collection Software: Product is End of Life (EoL), no update provided\nABI PRISM 3100/3100-Avant Data Collection Software: Product is End of Life (EoL), no update provided\nABI PRISM 310 Data Collection Software: Product is End of Life (EoL), no update provided\n\n\n\nFor users who are unable to immediately implement all applicable security updates, Thermo Fisher Scientific recommends implementing the following interim mitigation measures until the applicable updates have been installed:\u00a0\n\n  *  Maintain a secure chain of custody for files generated by the HID instrumentation throughout the analysis workflow.\n  *  Store generated files on encrypted, password-protected storage media (for example, encrypted USB drives or encrypted hard drives).\n  *  Restrict access to generated files to authorized personnel in accordance with your laboratory\u0027s access control policies.\n  *  Apply the principle of least privilege by limiting user permissions on systems operating the HID instrumentation or hosting associated data analysis and secondary analysis software.\n  *  Leverage firewall rules and network access control lists (NACLs) to restrict internet connectivity to only trusted sources.\n\n\n\n\nFor more information, refer to Thermo Fisher\u0027s security bulletin.\n https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-17583",
        "datePublished": "2026-08-05T20:23:32.890Z",
        "dateReserved": "2026-07-27T15:53:40.951Z",
        "dateUpdated": "2026-08-06T13:34:57.240Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54307 (GCVE-0-2025-54307)

    Vulnerability from nvd – Published: 2025-12-04 00:00 – Updated: 2025-12-05 19:57
    VLAI
    Summary
    An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. The /configure/plugins/plugin/upload/zip/ and /configure/newupdates/offline/bundle/upload/ endpoints allow low-privilege users to upload ZIP files to the server. The plupload_file_upload function handles these file uploads and constructs the destination file path by using either the name parameter or the uploaded filename, neither of which is properly sanitized. The file extension is extracted by splitting the filename, and a format string is used to construct the final file path, leaving the destination path vulnerable to path traversal. An authenticated attacker with network connectivity can write arbitrary files to the server, enabling remote code execution after overwriting an executable file. An example is the pdflatex executable, which is executed through subprocess.Popen in the write_report_pdf function after requests to a /report/latex/(\d+).pdf endpoint.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 19:57 UTC
    CWE
    • n/a
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54307",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T19:57:05.399563Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-22",
                    "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T19:57:57.971Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. The /configure/plugins/plugin/upload/zip/ and /configure/newupdates/offline/bundle/upload/ endpoints allow low-privilege users to upload ZIP files to the server. The plupload_file_upload function handles these file uploads and constructs the destination file path by using either the name parameter or the uploaded filename, neither of which is properly sanitized. The file extension is extracted by splitting the filename, and a format string is used to construct the final file path, leaving the destination path vulnerable to path traversal. An authenticated attacker with network connectivity can write arbitrary files to the server, enabling remote code execution after overwriting an executable file. An example is the pdflatex executable, which is executed through subprocess.Popen in the write_report_pdf function after requests to a /report/latex/(\\d+).pdf endpoint."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T15:00:55.325Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54307",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T19:57:57.971Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54306 (GCVE-0-2025-54306)

    Vulnerability from nvd – Published: 2025-12-04 00:00 – Updated: 2025-12-05 20:01
    VLAI
    Summary
    An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. A remote code execution vulnerability exists in the network configuration functionality, stemming from insufficient input validation when processing network configuration parameters through administrative endpoints. The application allows administrators to modify the server's network configuration through the Django application. This configuration is processed by Bash scripts (TSsetnoproxy and TSsetproxy) that write user-controlled data directly to environment variables without proper sanitization. After updating environment variables, the scripts execute a source command on /etc/environment; if an attacker injects malicious data into environment variables, this command can enable arbitrary command execution. The vulnerability begins with the /admin/network endpoint, which passes user-supplied form data as arguments to subprocess.Popen calls. The user-supplied input is then used to update environment variables in TSsetnoproxy and TSsetproxy, and finally source $environment is executed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 19:59 UTC
    CWE
    • n/a
    • CWE-20 - Improper Input Validation
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.2,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "HIGH",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54306",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T19:59:47.816163Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-20",
                    "description": "CWE-20 Improper Input Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T20:01:01.183Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. A remote code execution vulnerability exists in the network configuration functionality, stemming from insufficient input validation when processing network configuration parameters through administrative endpoints. The application allows administrators to modify the server\u0027s network configuration through the Django application. This configuration is processed by Bash scripts (TSsetnoproxy and TSsetproxy) that write user-controlled data directly to environment variables without proper sanitization. After updating environment variables, the scripts execute a source command on /etc/environment; if an attacker injects malicious data into environment variables, this command can enable arbitrary command execution. The vulnerability begins with the /admin/network endpoint, which passes user-supplied form data as arguments to subprocess.Popen calls. The user-supplied input is then used to update environment variables in TSsetnoproxy and TSsetproxy, and finally source $environment is executed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T14:57:00.961Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54306",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T20:01:01.183Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54305 (GCVE-0-2025-54305)

    Vulnerability from nvd – Published: 2025-12-04 00:00 – Updated: 2025-12-05 19:07
    VLAI
    Summary
    An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. One of the middlewares included in this application, LocalhostAuthMiddleware, authenticates users as ionadmin if the REMOTE_ADDR property in request.META is set to 127.0.0.1, to 127.0.1.1, or to ::1. Any user with local access to the server may bypass authentication.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 19:05 UTC
    CWE
    • n/a
    • CWE-290 - Authentication Bypass by Spoofing
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54305",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T19:05:15.685877Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-290",
                    "description": "CWE-290 Authentication Bypass by Spoofing",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T19:07:10.828Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. One of the middlewares included in this application, LocalhostAuthMiddleware, authenticates users as ionadmin if the REMOTE_ADDR property in request.META is set to 127.0.0.1, to 127.0.1.1, or to ::1. Any user with local access to the server may bypass authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T14:56:30.958Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54305",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T19:07:10.828Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54303 (GCVE-0-2025-54303)

    Vulnerability from nvd – Published: 2025-12-04 00:00 – Updated: 2025-12-05 20:05
    VLAI
    Summary
    The Thermo Fisher Torrent Suite Django application 5.18.1 has weak default credentials, which are stored as fixtures for the Django ORM API. The ionadmin user account can be used to authenticate to default deployments with the password ionadmin. The user guide recommends changing default credentials; however, a password change policy for default administrative accounts is not enforced. Many deployments may retain default credentials, in which case an attacker is likely to be able to successfully authenticate with administrative privileges.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 20:04 UTC
    CWE
    • n/a
    • CWE-1392 - Use of Default Credentials
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54303",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T20:04:58.738872Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-1392",
                    "description": "CWE-1392 Use of Default Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T20:05:35.403Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Thermo Fisher Torrent Suite Django application 5.18.1 has weak default credentials, which are stored as fixtures for the Django ORM API. The ionadmin user account can be used to authenticate to default deployments with the password ionadmin. The user guide recommends changing default credentials; however, a password change policy for default administrative accounts is not enforced. Many deployments may retain default credentials, in which case an attacker is likely to be able to successfully authenticate with administrative privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T14:55:38.998Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54303",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T20:05:35.403Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-17583 (GCVE-0-2026-17583)

    Vulnerability from cvelistv5 – Published: 2026-08-05 20:23 – Updated: 2026-08-06 13:34
    VLAI
    Title
    Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check
    Summary
    The affected Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-06 13:34 UTC
    CWE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-17583",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-06T13:34:47.788856Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-06T13:34:57.240Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems 3500/3500xL Series Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "4.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems 3730/3730xL Series Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "5.0.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.5",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems SeqStudio Flex Series Instrument Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "1.2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems GeneMapper ID-X Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "1.7.3",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Applied Biosystems 3130 Series Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "4.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ABI PRISM 3100/3100-Avant Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "2.0",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "ABI PRISM 310 Data Collection Software",
              "vendor": "Thermo Fisher",
              "versions": [
                {
                  "lessThanOrEqual": "3.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Nathaniel Adams, Laura Gaydosh-Combs, and Kevin Dyer reported this vulnerability to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan\u003eThe affected\u003c/span\u003e\n\nThermo Fisher Applied Biosystems Genetic Analyzers are\u003cspan\u003e\u0026nbsp;vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.\u003c/span\u003e"
                }
              ],
              "value": "The affected\n\nThermo Fisher Applied Biosystems Genetic Analyzers are\u00a0vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-353",
                  "description": "CWE-353",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-05T20:23:32.890Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf"
            },
            {
              "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01"
            },
            {
              "url": "https://www.cve.org/CVERecord?id=CVE-2026-17583"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eThermo Fisher has developed security updates to address the vulnerability. The security updates implement the use of digital signatures on the instrument software that adds an extralayer of protection. Moving forward, this will help users verify that data files have not been modified.\u003c/p\u003e\u003cp\u003eApplied Biosystems 3500/3500xL Series Data Collection Software: Update to version 4.0.3\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe\"\u003ehttps://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems 3730/3730xL Series Data Collection Software: Update to version 5.0.3\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe\"\u003ehttps://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems SeqStudio Genetic Analyzer Data Collection Software: Update to version 1.2.6\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg\"\u003ehttps://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems SeqStudio Flex Series Instrument Software: Update to version 1.2.1\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg\"\u003ehttps://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems GeneMapper ID-X Software: Update to version 1.7.4\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe\"\u003ehttps://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Thermo Fisher has developed security updates to address the vulnerability. The security updates implement the use of digital signatures on the instrument software that adds an extralayer of protection. Moving forward, this will help users verify that data files have not been modified.\n\n\n\nApplied Biosystems 3500/3500xL Series Data Collection Software: Update to version 4.0.3\n https://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe \n\n\n\nApplied Biosystems 3730/3730xL Series Data Collection Software: Update to version 5.0.3\n https://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe \n\n\n\nApplied Biosystems SeqStudio Genetic Analyzer Data Collection Software: Update to version 1.2.6\n https://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg \n\n\n\nApplied Biosystems SeqStudio Flex Series Instrument Software: Update to version 1.2.1\n https://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg \n\n\n\nApplied Biosystems GeneMapper ID-X Software: Update to version 1.7.4\n https://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe"
            }
          ],
          "source": {
            "advisory": "ICSMA-26-216-01",
            "discovery": "EXTERNAL"
          },
          "title": "Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eApplied Biosystems 3130 Series Data Collection Software: Product is End of Life (EoL), no update provided\u003cbr\u003eABI PRISM 3100/3100-Avant Data Collection Software: Product is End of Life (EoL), no update provided\u003cbr\u003eABI PRISM 310 Data Collection Software: Product is End of Life (EoL), no update provided\u003c/p\u003e\u003cp\u003eFor users who are unable to immediately implement all applicable security updates, Thermo Fisher Scientific recommends implementing the following interim mitigation measures until the applicable updates have been installed:\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003eMaintain a secure chain of custody for files generated by the HID instrumentation throughout the analysis workflow.\u003c/li\u003e\u003cli\u003eStore generated files on encrypted, password-protected storage media (for example, encrypted USB drives or encrypted hard drives).\u003c/li\u003e\u003cli\u003eRestrict access to generated files to authorized personnel in accordance with your laboratory\u0027s access control policies.\u003c/li\u003e\u003cli\u003eApply the principle of least privilege by limiting user permissions on systems operating the HID instrumentation or hosting associated data analysis and secondary analysis software.\u003c/li\u003e\u003cli\u003eLeverage firewall rules and network access control lists (NACLs) to restrict internet connectivity to only trusted sources.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information, refer to Thermo Fisher\u0027s security bulletin.\u003cbr\u003e\u003ca href=\"https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf\"\u003ehttps://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf\u003c/a\u003e\u003c/p\u003e"
                }
              ],
              "value": "Applied Biosystems 3130 Series Data Collection Software: Product is End of Life (EoL), no update provided\nABI PRISM 3100/3100-Avant Data Collection Software: Product is End of Life (EoL), no update provided\nABI PRISM 310 Data Collection Software: Product is End of Life (EoL), no update provided\n\n\n\nFor users who are unable to immediately implement all applicable security updates, Thermo Fisher Scientific recommends implementing the following interim mitigation measures until the applicable updates have been installed:\u00a0\n\n  *  Maintain a secure chain of custody for files generated by the HID instrumentation throughout the analysis workflow.\n  *  Store generated files on encrypted, password-protected storage media (for example, encrypted USB drives or encrypted hard drives).\n  *  Restrict access to generated files to authorized personnel in accordance with your laboratory\u0027s access control policies.\n  *  Apply the principle of least privilege by limiting user permissions on systems operating the HID instrumentation or hosting associated data analysis and secondary analysis software.\n  *  Leverage firewall rules and network access control lists (NACLs) to restrict internet connectivity to only trusted sources.\n\n\n\n\nFor more information, refer to Thermo Fisher\u0027s security bulletin.\n https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 1.0.4"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2026-17583",
        "datePublished": "2026-08-05T20:23:32.890Z",
        "dateReserved": "2026-07-27T15:53:40.951Z",
        "dateUpdated": "2026-08-06T13:34:57.240Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54306 (GCVE-0-2025-54306)

    Vulnerability from cvelistv5 – Published: 2025-12-04 00:00 – Updated: 2025-12-05 20:01
    VLAI
    Summary
    An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. A remote code execution vulnerability exists in the network configuration functionality, stemming from insufficient input validation when processing network configuration parameters through administrative endpoints. The application allows administrators to modify the server's network configuration through the Django application. This configuration is processed by Bash scripts (TSsetnoproxy and TSsetproxy) that write user-controlled data directly to environment variables without proper sanitization. After updating environment variables, the scripts execute a source command on /etc/environment; if an attacker injects malicious data into environment variables, this command can enable arbitrary command execution. The vulnerability begins with the /admin/network endpoint, which passes user-supplied form data as arguments to subprocess.Popen calls. The user-supplied input is then used to update environment variables in TSsetnoproxy and TSsetproxy, and finally source $environment is executed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 19:59 UTC
    CWE
    • n/a
    • CWE-20 - Improper Input Validation
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.2,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "HIGH",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54306",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T19:59:47.816163Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-20",
                    "description": "CWE-20 Improper Input Validation",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T20:01:01.183Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. A remote code execution vulnerability exists in the network configuration functionality, stemming from insufficient input validation when processing network configuration parameters through administrative endpoints. The application allows administrators to modify the server\u0027s network configuration through the Django application. This configuration is processed by Bash scripts (TSsetnoproxy and TSsetproxy) that write user-controlled data directly to environment variables without proper sanitization. After updating environment variables, the scripts execute a source command on /etc/environment; if an attacker injects malicious data into environment variables, this command can enable arbitrary command execution. The vulnerability begins with the /admin/network endpoint, which passes user-supplied form data as arguments to subprocess.Popen calls. The user-supplied input is then used to update environment variables in TSsetnoproxy and TSsetproxy, and finally source $environment is executed."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T14:57:00.961Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54306",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T20:01:01.183Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54305 (GCVE-0-2025-54305)

    Vulnerability from cvelistv5 – Published: 2025-12-04 00:00 – Updated: 2025-12-05 19:07
    VLAI
    Summary
    An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. One of the middlewares included in this application, LocalhostAuthMiddleware, authenticates users as ionadmin if the REMOTE_ADDR property in request.META is set to 127.0.0.1, to 127.0.1.1, or to ::1. Any user with local access to the server may bypass authentication.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 19:05 UTC
    CWE
    • n/a
    • CWE-290 - Authentication Bypass by Spoofing
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54305",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T19:05:15.685877Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-290",
                    "description": "CWE-290 Authentication Bypass by Spoofing",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T19:07:10.828Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. One of the middlewares included in this application, LocalhostAuthMiddleware, authenticates users as ionadmin if the REMOTE_ADDR property in request.META is set to 127.0.0.1, to 127.0.1.1, or to ::1. Any user with local access to the server may bypass authentication."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T14:56:30.958Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54305",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T19:07:10.828Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54307 (GCVE-0-2025-54307)

    Vulnerability from cvelistv5 – Published: 2025-12-04 00:00 – Updated: 2025-12-05 19:57
    VLAI
    Summary
    An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. The /configure/plugins/plugin/upload/zip/ and /configure/newupdates/offline/bundle/upload/ endpoints allow low-privilege users to upload ZIP files to the server. The plupload_file_upload function handles these file uploads and constructs the destination file path by using either the name parameter or the uploaded filename, neither of which is properly sanitized. The file extension is extracted by splitting the filename, and a format string is used to construct the final file path, leaving the destination path vulnerable to path traversal. An authenticated attacker with network connectivity can write arbitrary files to the server, enabling remote code execution after overwriting an executable file. An example is the pdflatex executable, which is executed through subprocess.Popen in the write_report_pdf function after requests to a /report/latex/(\d+).pdf endpoint.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 19:57 UTC
    CWE
    • n/a
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 8.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54307",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T19:57:05.399563Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-22",
                    "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T19:57:57.971Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in the Thermo Fisher Torrent Suite Django application 5.18.1. The /configure/plugins/plugin/upload/zip/ and /configure/newupdates/offline/bundle/upload/ endpoints allow low-privilege users to upload ZIP files to the server. The plupload_file_upload function handles these file uploads and constructs the destination file path by using either the name parameter or the uploaded filename, neither of which is properly sanitized. The file extension is extracted by splitting the filename, and a format string is used to construct the final file path, leaving the destination path vulnerable to path traversal. An authenticated attacker with network connectivity can write arbitrary files to the server, enabling remote code execution after overwriting an executable file. An example is the pdflatex executable, which is executed through subprocess.Popen in the write_report_pdf function after requests to a /report/latex/(\\d+).pdf endpoint."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T15:00:55.325Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54307",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T19:57:57.971Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-54303 (GCVE-0-2025-54303)

    Vulnerability from cvelistv5 – Published: 2025-12-04 00:00 – Updated: 2025-12-05 20:05
    VLAI
    Summary
    The Thermo Fisher Torrent Suite Django application 5.18.1 has weak default credentials, which are stored as fixtures for the Django ORM API. The ionadmin user account can be used to authenticate to default deployments with the password ionadmin. The user guide recommends changing default credentials; however, a password change policy for default administrative accounts is not enforced. Many deployments may retain default credentials, in which case an attacker is likely to be able to successfully authenticate with administrative privileges.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-12-05 20:04 UTC
    CWE
    • n/a
    • CWE-1392 - Use of Default Credentials
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-54303",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-05T20:04:58.738872Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-1392",
                    "description": "CWE-1392 Use of Default Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-12-05T20:05:35.403Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Thermo Fisher Torrent Suite Django application 5.18.1 has weak default credentials, which are stored as fixtures for the Django ORM API. The ionadmin user account can be used to authenticate to default deployments with the password ionadmin. The user guide recommends changing default credentials; however, a password change policy for default administrative accounts is not enforced. Many deployments may retain default credentials, in which case an attacker is likely to be able to successfully authenticate with administrative privileges."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-04T14:55:38.998Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.thermofisher.com/us/en/home/life-science/sequencing/next-generation-sequencing/ion-torrent-next-generation-sequencing-workflow/ion-torrent-next-generation-sequencing-data-analysis-workflow/ion-torrent-suite-software.html"
            },
            {
              "url": "https://assets.thermofisher.com/TFS-Assets/LSG/manuals/MAN0026163-Torrent-Suite-5.18-UG.pdf"
            },
            {
              "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/Ion_OneTouch_2_and_Torrent_Suite_Software.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2025-54303",
        "datePublished": "2025-12-04T00:00:00.000Z",
        "dateReserved": "2025-07-18T00:00:00.000Z",
        "dateUpdated": "2025-12-05T20:05:35.403Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }