CVE-2011-2959 (GCVE-0-2011-2959)
Vulnerability from cvelistv5 – Published: 2011-07-29 19:00 – Updated: 2024-09-16 18:49
VLAI?
Summary
Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet to TCP port 22202.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:15:32.021Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "44345",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/44345"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf"
},
{
"name": "72117",
"tags": [
"vdb-entry",
"x_refsource_OSVDB",
"x_transferred"
],
"url": "http://www.osvdb.org/72117"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.insomniasec.com/advisories/ISVA-110427.1.htm"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet to TCP port 22202."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2011-07-29T19:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "44345",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/44345"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf"
},
{
"name": "72117",
"tags": [
"vdb-entry",
"x_refsource_OSVDB"
],
"url": "http://www.osvdb.org/72117"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.insomniasec.com/advisories/ISVA-110427.1.htm"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-2959",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet to TCP port 22202."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "44345",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/44345"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf"
},
{
"name": "72117",
"refsource": "OSVDB",
"url": "http://www.osvdb.org/72117"
},
{
"name": "http://www.insomniasec.com/advisories/ISVA-110427.1.htm",
"refsource": "MISC",
"url": "http://www.insomniasec.com/advisories/ISVA-110427.1.htm"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-2959",
"datePublished": "2011-07-29T19:00:00Z",
"dateReserved": "2011-07-29T00:00:00Z",
"dateUpdated": "2024-09-16T18:49:15.628Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"9\", \"matchCriteriaId\": \"19D222AA-6EC8-4EB4-87C5-7BA3FAED6CC7\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:2.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"45468C48-3D40-4A21-9EF0-6B7F8D889116\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:3.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3B8849FF-F94B-4049-8503-94FC5E8A9DB4\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:4.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2973964D-2F93-4B6D-8B29-53A0B40ADF55\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:5.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E98A9963-0465-4113-81AE-CB196AC4FB85\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:5.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B1FDA273-4DDD-4AEB-9564-F1FD4EB9A049\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:6:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"076184B2-8381-4BFD-B77E-0C35757161D5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:7:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D371A71E-3F97-43A8-A9E9-2C81DE4DDB7E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:7t:igss:8:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E680A5B4-6207-4715-BFA6-1D3BBCB28D48\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet to TCP port 22202.\"}, {\"lang\": \"es\", \"value\": \"Desbordamiento de b\\u00fafer basado en pila en el servicio ODBC - Open Database Connectivity (Odbcixv9se.exe) en 7-Technologies Interactive Graphical SCADA System (IGSS) v9 y anteriores permite a atacantes remotos causar una denegaci\\u00f3n de servicio (ca\\u00edda de la aplicaci\\u00f3n) y posiblemente ejecutar c\\u00f3digo de su elecci\\u00f3n a trav\\u00e9s de un paquete especialmente modificado contra el puerto TCP 22202.\"}]",
"id": "CVE-2011-2959",
"lastModified": "2024-11-21T01:29:22.120",
"metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2011-07-29T19:55:03.470",
"references": "[{\"url\": \"http://secunia.com/advisories/44345\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.insomniasec.com/advisories/ISVA-110427.1.htm\", \"source\": \"cve@mitre.org\"}, {\"url\": \"http://www.osvdb.org/72117\", \"source\": \"cve@mitre.org\"}, {\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Patch\", \"US Government Resource\"]}, {\"url\": \"http://secunia.com/advisories/44345\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.insomniasec.com/advisories/ISVA-110427.1.htm\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://www.osvdb.org/72117\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"US Government Resource\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2011-2959\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2011-07-29T19:55:03.470\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Stack-based buffer overflow in the Open Database Connectivity (ODBC) service (Odbcixv9se.exe) in 7-Technologies Interactive Graphical SCADA System (IGSS) 9 and earlier allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a crafted packet to TCP port 22202.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer basado en pila en el servicio ODBC - Open Database Connectivity (Odbcixv9se.exe) en 7-Technologies Interactive Graphical SCADA System (IGSS) v9 y anteriores permite a atacantes remotos causar una denegaci\u00f3n de servicio (ca\u00edda de la aplicaci\u00f3n) y posiblemente ejecutar c\u00f3digo de su elecci\u00f3n a trav\u00e9s de un paquete especialmente modificado contra el puerto TCP 22202.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"9\",\"matchCriteriaId\":\"19D222AA-6EC8-4EB4-87C5-7BA3FAED6CC7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"45468C48-3D40-4A21-9EF0-6B7F8D889116\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B8849FF-F94B-4049-8503-94FC5E8A9DB4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:4.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2973964D-2F93-4B6D-8B29-53A0B40ADF55\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E98A9963-0465-4113-81AE-CB196AC4FB85\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:5.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1FDA273-4DDD-4AEB-9564-F1FD4EB9A049\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"076184B2-8381-4BFD-B77E-0C35757161D5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D371A71E-3F97-43A8-A9E9-2C81DE4DDB7E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:7t:igss:8:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E680A5B4-6207-4715-BFA6-1D3BBCB28D48\"}]}]}],\"references\":[{\"url\":\"http://secunia.com/advisories/44345\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.insomniasec.com/advisories/ISVA-110427.1.htm\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.osvdb.org/72117\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"US Government Resource\"]},{\"url\":\"http://secunia.com/advisories/44345\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.insomniasec.com/advisories/ISVA-110427.1.htm\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.osvdb.org/72117\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-119-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…