Summary
Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T19:50:05.408Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://en.securitylab.ru/lab/PT-2012-42" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2012-09-18T14:00:00Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "http://en.securitylab.ru/lab/PT-2012-42" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-3028", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://en.securitylab.ru/lab/PT-2012-42", "refsource": "MISC", "url": "http://en.securitylab.ru/lab/PT-2012-42" }, { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-3028", "datePublished": "2012-09-18T14:00:00Z", "dateReserved": "2012-05-30T00:00:00Z", "dateUpdated": "2024-09-16T20:32:23.222Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2012-3028\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2012-09-18T14:55:01.397\",\"lastModified\":\"2012-09-19T04:00:00.000\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cross-site request forgery (CSRF) vulnerability in WebNavigator in Siemens WinCC 7.0 SP3 and earlier, as used in SIMATIC PCS7 and other products, allows remote attackers to hijack the authentication of arbitrary users for requests that modify data or cause a denial of service.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de falsificaci\u00f3n de peticiones en sitios cruzados (CSRF) en WebNavigator en Siemens WinCC v7.0 SP3 y versiones anteriores, tal como se utiliza en SIMATIC PCS v7 y otros productos, permite a atacantes remotos provocar una denegaci\u00f3n de servicio o secuestrar la autenticaci\u00f3n de usuarios de su elecci\u00f3n para las peticiones que modifican datos.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs7:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8B894F4-9635-4436-BC0A-E43280426017\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:sp3:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.0\",\"matchCriteriaId\":\"5AC094B0-B1BE-436D-A8D3-2008D0CDE070\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4CB277F-7ECB-4F44-8BB5-A3D350486EE7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:5.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"616535F1-F609-408B-AE48-61ACF48748A1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7F322FCB-32F4-4C5A-A7F5-F7EF41188C88\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"69822DB4-DC79-4F88-A470-5AC512C77377\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp3:*:*:*:*:*:*\",\"matchCriteriaId\":\"996DE8BD-DD51-41EF-9882-C2BD2CC5FE53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:6.0:sp4:*:*:*:*:*:*\",\"matchCriteriaId\":\"945C8B46-4CDA-4143-889C-30E30E93DB29\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A33F9015-7058-419A-8762-CB2AE4ACF1A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6271FCC-CCF6-4D31-801A-B4B0DC4639DD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF7A6B2B-D573-4285-B3B4-136F2BE7E710\"}]}]}],\"references\":[{\"url\":\"http://en.securitylab.ru/lab/PT-2012-42\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-864051.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-12-256-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.