CVE-2014-0766 (GCVE-0-2014-0766)

Vulnerability from cvelistv5 – Published: 2014-04-12 01:00 – Updated: 2025-09-19 19:10
VLAI?
Summary
An attacker can exploit this vulnerability by copying an overly long NodeName2 argument into a statically sized buffer on the stack to overflow the static stack buffer. An attacker may use this vulnerability to remotely execute arbitrary code.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Advantech WebAccess Affected: 0 , ≤ 7.1 (custom)
Unaffected: 7.2
Create a notification for this product.
Credits
Andrea Micalizzi, aka rgod, Tom Gallagher, and an independent anonymous researcher working with HP’s Zero Day Initiative (ZDI)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-079-03"
          },
          {
            "name": "66725",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/66725"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "WebAccess",
          "vendor": "Advantech",
          "versions": [
            {
              "lessThanOrEqual": "7.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "7.2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Andrea Micalizzi, aka rgod, Tom Gallagher, and an independent anonymous researcher working with HP\u2019s Zero Day Initiative (ZDI)"
        }
      ],
      "datePublic": "2014-04-08T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\n\n\nAn attacker can exploit this vulnerability by copying an overly long \nNodeName2 argument into a statically sized buffer on the stack to \noverflow the static stack buffer. An attacker may use this vulnerability\n to remotely execute arbitrary code.\n\n\u003c/p\u003e"
            }
          ],
          "value": "An attacker can exploit this vulnerability by copying an overly long \nNodeName2 argument into a statically sized buffer on the stack to \noverflow the static stack buffer. An attacker may use this vulnerability\n to remotely execute arbitrary code."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-19T19:10:40.843Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-079-03"
        },
        {
          "name": "66740",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66740"
        },
        {
          "url": "http://webaccess.advantech.com/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAdvantech has created a new version (Version 7.2) that mitigates each\n of the vulnerabilities described above. Users may download this version\n from the following location at their web site:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://webaccess.advantech.com/downloads.php?item=software\"\u003ehttp://webaccess.advantech.com/downloads.php?item=software\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor additional information about WebAccess, please visit the following Advantech web site:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://webaccess.advantech.com/\"\u003ehttp://webaccess.advantech.com/\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Advantech has created a new version (Version 7.2) that mitigates each\n of the vulnerabilities described above. Users may download this version\n from the following location at their web site:\u00a0 http://webaccess.advantech.com/downloads.php?item=software \n\nFor additional information about WebAccess, please visit the following Advantech web site:\u00a0 http://webaccess.advantech.com/"
        }
      ],
      "source": {
        "advisory": "ICSA-14-079-03",
        "discovery": "EXTERNAL"
      },
      "title": "Advantech WebAccess Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0763",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple SQL injection vulnerabilities in DBVisitor.dll in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary SQL commands via SOAP requests to unspecified functions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-079-03",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-079-03"
            },
            {
              "name": "66740",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66740"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0766",
    "datePublished": "2014-04-12T01:00:00",
    "dateReserved": "2014-01-02T00:00:00",
    "dateUpdated": "2025-09-19T19:10:40.843Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:advantech:advantech_webaccess:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"7.1\", \"matchCriteriaId\": \"3D097D1E-9A02-40B0-93BD-163A11638118\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:advantech:advantech_webaccess:5.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"090C819C-5964-4158-80E6-2D4751A5E8BF\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:advantech:advantech_webaccess:6.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7CF61F9C-360A-4B70-951D-8EE9CF6E55FA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:advantech:advantech_webaccess:7.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1082E1D5-AF49-431F-9172-98C2D2887C96\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Stack-based buffer overflow in Advantech WebAccess before 7.2 allows remote attackers to execute arbitrary code via a long NodeName2 argument.\"}, {\"lang\": \"es\", \"value\": \"Desbordamiento de buffer basado en pila en Advantech WebAccess anterior a 7.2 permite a atacantes remotos ejecutar c\\u00f3digo arbitrario a trav\\u00e9s de un argumento NodeName2 largo.\"}]",
      "id": "CVE-2014-0766",
      "lastModified": "2024-11-21T02:02:46.320",
      "metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2014-04-12T04:37:31.533",
      "references": "[{\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-14-079-03\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://www.securityfocus.com/bid/66725\", \"source\": \"ics-cert@hq.dhs.gov\"}, {\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-14-079-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://www.securityfocus.com/bid/66725\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2014-0766\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2014-04-12T04:37:31.533\",\"lastModified\":\"2025-09-19T20:15:37.000\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An attacker can exploit this vulnerability by copying an overly long \\nNodeName2 argument into a statically sized buffer on the stack to \\noverflow the static stack buffer. An attacker may use this vulnerability\\n to remotely execute arbitrary code.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de buffer basado en pila en Advantech WebAccess anterior a 7.2 permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de un argumento NodeName2 largo.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:advantech_webaccess:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.1\",\"matchCriteriaId\":\"3D097D1E-9A02-40B0-93BD-163A11638118\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:advantech_webaccess:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"090C819C-5964-4158-80E6-2D4751A5E8BF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:advantech_webaccess:6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CF61F9C-360A-4B70-951D-8EE9CF6E55FA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:advantech_webaccess:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1082E1D5-AF49-431F-9172-98C2D2887C96\"}]}]}],\"references\":[{\"url\":\"http://webaccess.advantech.com/\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.securityfocus.com/bid/66740\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-14-079-03\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-14-079-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/66725\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…