CVE-2015-2823
Vulnerability from cvelistv5
Published
2015-04-08 16:00
Modified
2024-08-06 05:24
Severity ?
EPSS score ?
Summary
Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T05:24:39.120Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "74040", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/74040" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2015-04-08T00:00:00", "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-10T14:06:08", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "name": "74040", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/74040" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2015-2823", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "74040", "refsource": "BID", "url": "http://www.securityfocus.com/bid/74040" }, { "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2015-2823", "datePublished": "2015-04-08T16:00:00", "dateReserved": "2015-04-01T00:00:00", "dateUpdated": "2024-08-06T05:24:39.120Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2015-2823\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2015-04-08T16:59:01.270\",\"lastModified\":\"2016-11-28T19:21:58.403\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), and SIMATIC WinCC 7.x before 7.3 Upd4 allow remote attackers to complete authentication by leveraging knowledge of a password hash without knowledge of the associated password.\"},{\"lang\":\"es\",\"value\":\"Siemens SIMATIC HMI Basic Panels 2nd Generation anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional anterior a WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Basic Panels 1st Generation (WinCC TIA Portal), SIMATIC HMI Mobile Panel 277 (WinCC TIA Portal), SIMATIC HMI Multi Panels (WinCC TIA Portal), y SIMATIC WinCC 7.x anterior a 7.3 Upd4 permiten a atacantes remotos completar la autenticaci\u00f3n mediante el aprovechamiento de conocimiento de un hash de contrase\u00f1as sin conocer la contrase\u00f1a asociada.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A33F9015-7058-419A-8762-CB2AE4ACF1A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B16BB99-49E0-443E-BEE0-C7694D2C54E1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D3788F5-FBE9-4BA8-910B-B3B216C544E5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:7.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B22136E0-9DEE-4F5A-BD5C-D0AE9E30A086\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:sp1:*:*:*:*:*:*\",\"versionEndIncluding\":\"13.0\",\"matchCriteriaId\":\"76613CE7-E3DB-4E11-8F87-5DB5A67CB6E3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:wincc:*:sp1:*:*:advanced:*:*:*\",\"versionEndIncluding\":\"13.0\",\"matchCriteriaId\":\"6C5C15E0-ADB8-4DAE-8D7C-B606FC544CE5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_basic_panels_generation_1:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BF50B5E3-9457-4BE2-A83B-A5936B1C453C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_basic_panels_generation_2:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8ADB8F11-4C36-41BA-BBF5-0F1F60F6FC4F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"30B2BFDE-5FB0-481F-98ED-8C30FBC8F565\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_mobile_panel_277:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F4698AC-4347-4047-B976-9F3F822E7B7B\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD775BB6-1801-4CD9-9F18-250287BA006E\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/74040\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-487246.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-487246.pdf\",\"source\":\"cve@mitre.org\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.