CVE-2017-2850 (GCVE-0-2017-2850)
Vulnerability from cvelistv5 – Published: 2017-06-29 17:00 – Updated: 2024-09-17 00:01- password injection
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/99184 | vdb-entryx_refsource_BID |
| https://talosintelligence.com/vulnerability_repor… | x_refsource_MISC |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Foscam | Indoor IP Camera C1 Series |
Affected:
n/a
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T14:09:17.350Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "99184",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/99184"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Indoor IP Camera C1 Series",
"vendor": "Foscam",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-06-19T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary characters in the pureftpd.passwd file during a username change, which in turn allows for bypassing chroot restrictions in the FTP server. An attacker can simply send an HTTP request to the device to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "password injection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-19T18:23:26.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "99184",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/99184"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"DATE_PUBLIC": "2017-06-19T00:00:00",
"ID": "CVE-2017-2850",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Indoor IP Camera C1 Series",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Foscam"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary characters in the pureftpd.passwd file during a username change, which in turn allows for bypassing chroot restrictions in the FTP server. An attacker can simply send an HTTP request to the device to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.8,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "password injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "99184",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/99184"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2017-2850",
"datePublished": "2017-06-29T17:00:00.000Z",
"dateReserved": "2016-12-01T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:01:46.167Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-2850",
"date": "2026-10-29",
"epss": "0.02212",
"percentile": "0.82568"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:foscam:c1_indoor_hd_camera_firmware:2.52.2.37:*:*:*:*:*:*:*",
"matchCriteriaId": "0E42CC0A-E8B0-407C-A6B8-079CC10D2271",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:foscam:c1_indoor_hd_camera:-:*:*:*:*:*:*:*",
"matchCriteriaId": "24F43869-2168-407A-B546-06998CA5D572",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary characters in the pureftpd.passwd file during a username change, which in turn allows for bypassing chroot restrictions in the FTP server. An attacker can simply send an HTTP request to the device to trigger this vulnerability."
},
{
"lang": "es",
"value": "En la interfaz de gesti\u00f3n web en las c\u00e1maras Foscam C1 Indoor HD que ejecutan el firmware de aplicaci\u00f3n en su versi\u00f3n 2.52.2.37, una petici\u00f3n HTTP especialmente manipulada puede permitir que un usuario inyecte caracteres arbitrarios en el archivo pureftpd.passwd durante un cambio de nombre de usuario, lo que permite que se omitan las restricciones chroot en el servidor FTP. Un atacante puede simplemente enviar una petici\u00f3n HTTP al dispositivo para desencadenar esta vulnerabilidad."
}
],
"id": "CVE-2017-2850",
"lastModified": "2024-11-21T03:24:19.510",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-06-29T17:29:00.367",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Broken Link"
],
"url": "http://www.securityfocus.com/bid/99184"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Technical Description",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "http://www.securityfocus.com/bid/99184"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Technical Description",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:foscam:c1_indoor_hd_camera_firmware:2.52.2.37:*:*:*:*:*:*:*",
"matchCriteriaId": "0E42CC0A-E8B0-407C-A6B8-079CC10D2271",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:foscam:c1_indoor_hd_camera:-:*:*:*:*:*:*:*",
"matchCriteriaId": "24F43869-2168-407A-B546-06998CA5D572",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In the web management interface in Foscam C1 Indoor HD cameras with application firmware 2.52.2.37, a specially crafted HTTP request can allow for a user to inject arbitrary characters in the pureftpd.passwd file during a username change, which in turn allows for bypassing chroot restrictions in the FTP server. An attacker can simply send an HTTP request to the device to trigger this vulnerability."
},
{
"lang": "es",
"value": "En la interfaz de gesti\u00f3n web en las c\u00e1maras Foscam C1 Indoor HD que ejecutan el firmware de aplicaci\u00f3n en su versi\u00f3n 2.52.2.37, una petici\u00f3n HTTP especialmente manipulada puede permitir que un usuario inyecte caracteres arbitrarios en el archivo pureftpd.passwd durante un cambio de nombre de usuario, lo que permite que se omitan las restricciones chroot en el servidor FTP. Un atacante puede simplemente enviar una petici\u00f3n HTTP al dispositivo para desencadenar esta vulnerabilidad."
}
],
"id": "CVE-2017-2850",
"lastModified": "2026-05-13T00:24:29.033",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-06-29T17:29:00.367",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Broken Link"
],
"url": "http://www.securityfocus.com/bid/99184"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Technical Description",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "http://www.securityfocus.com/bid/99184"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Technical Description",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2017-0352"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.