GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2018-0679 (GCVE-0-2018-0679)

Vulnerability from cvelistv5 – Published: 2018-11-15 15:00 – Updated: 2024-08-05 03:35
VLAI
Summary
Cross-site scripting vulnerability in multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions) allows attacker with administrator rights to inject arbitrary web script or HTML via the administrative page.
CWE
  • Cross-site scripting
References
URL Tags
https://www.fxc.jp/news/20171228.html x_refsource_MISC
http://jvn.jp/en/jp/JVN68528150/index.html third-party-advisoryx_refsource_JVN
Impacted products
Vendor Product Version CPE status
FXC Inc. multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions) Affected: Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions
guessed Create a notification for this product.
Date Public
2018-11-15 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T03:35:48.781Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.fxc.jp/news/20171228.html"
          },
          {
            "name": "JVN#68528150",
            "tags": [
              "third-party-advisory",
              "x_refsource_JVN",
              "x_transferred"
            ],
            "url": "http://jvn.jp/en/jp/JVN68528150/index.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions)",
          "vendor": "FXC Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions"
            }
          ]
        }
      ],
      "datePublic": "2018-11-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting vulnerability in multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions) allows attacker with administrator rights to inject arbitrary web script or HTML via the administrative page."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Cross-site scripting",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-11-15T14:57:01.000Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.fxc.jp/news/20171228.html"
        },
        {
          "name": "JVN#68528150",
          "tags": [
            "third-party-advisory",
            "x_refsource_JVN"
          ],
          "url": "http://jvn.jp/en/jp/JVN68528150/index.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2018-0679",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "FXC Inc."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting vulnerability in multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions) allows attacker with administrator rights to inject arbitrary web script or HTML via the administrative page."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.fxc.jp/news/20171228.html",
              "refsource": "MISC",
              "url": "https://www.fxc.jp/news/20171228.html"
            },
            {
              "name": "JVN#68528150",
              "refsource": "JVN",
              "url": "http://jvn.jp/en/jp/JVN68528150/index.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2018-0679",
    "datePublished": "2018-11-15T15:00:00.000Z",
    "dateReserved": "2017-11-27T00:00:00.000Z",
    "dateUpdated": "2024-08-05T03:35:48.781Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-0679",
      "date": "2026-09-16",
      "epss": "0.00523",
      "percentile": "0.43111"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5210_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.22\", \"matchCriteriaId\": \"72B8C77B-756B-4DBF-8642-9CEFA3E64FAB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5210:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8C380189-64D0-4E67-A7BB-AAB484497E49\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5218_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.22\", \"matchCriteriaId\": \"A6BF9D0B-4A8E-4748-8F11-BA13560F4D16\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5218:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"22202750-42B2-49C4-913A-109E2B4A9ED2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5224_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.22\", \"matchCriteriaId\": \"C14B632E-AFB3-4768-B55D-AC174A0C2EB8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5224:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17C40735-948D-49FF-BEC1-8EC5840E75D1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5426f_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.06\", \"matchCriteriaId\": \"B8063D2B-DD96-4624-85DC-3A5707C94203\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5426f:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FD2A9AE2-29E8-4662-881A-A4F9C83CF15D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5428_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.07\", \"matchCriteriaId\": \"9845D815-58C3-4138-8F75-36B559774F47\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5428:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CEB46925-3B3D-4980-8E32-B86E978BD13C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5210pe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.14\", \"matchCriteriaId\": \"FFF6CC07-DBEF-48C8-9369-731FDED0835B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5210pe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D6B7A903-7058-473F-B027-EC9408651BE9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5218pe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.14\", \"matchCriteriaId\": \"EEB412D1-5C4D-4800-8C05-42AE9AE4495B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5218pe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C568C89C-9A39-45EE-9345-2EB406AFF932\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:fxc5224pe_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.00.14\", \"matchCriteriaId\": \"66703C10-C292-438A-ADCF-6966DAF1002A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:fxc5224pe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B8077073-5A74-4512-86B1-1EB37E4C7928\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:ae1021_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"693C65D1-F2F8-4DC7-AA47-F9A0323AA118\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:ae1021:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"03B391D9-2AF4-4889-BFA3-52C11B4390C5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:fxc:ae1021pe_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BC6562B5-862B-490D-8B2A-D0250CF5C63A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:fxc:ae1021pe:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BB758E1E-0CF5-4CA6-9A08-2B33BF296D67\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Cross-site scripting vulnerability in multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions) allows attacker with administrator rights to inject arbitrary web script or HTML via the administrative page.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad Cross-Site Scripting (XSS) en m\\u00faltiples dispositivos de red de FXC Inc. (Managed Ethernet switch FXC5210/5218/5224 con firmware en versiones anteriores a la Ver1.00.22, Managed Ethernet switch FXC5426F con firmware en versiones anteriores a la Ver1.00.06, Managed Ethernet switch FXC5428 con firmware en versiones anteriores a la Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE con firmware en versiones anteriores a la Ver1.00.14 y Wireless LAN router AE1021/AE1021PE con firmware en todas las versiones) permite que un atacante con derechos de administrador inyecte scripts web o HTML arbitrarios mediante la p\\u00e1gina administrativa.\"}]",
      "id": "CVE-2018-0679",
      "lastModified": "2024-11-21T03:38:43.630",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 4.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2018-11-15T15:29:00.287",
      "references": "[{\"url\": \"http://jvn.jp/en/jp/JVN68528150/index.html\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.fxc.jp/news/20171228.html\", \"source\": \"vultures@jpcert.or.jp\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}, {\"url\": \"http://jvn.jp/en/jp/JVN68528150/index.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.fxc.jp/news/20171228.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "vultures@jpcert.or.jp",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-0679\",\"sourceIdentifier\":\"vultures@jpcert.or.jp\",\"published\":\"2018-11-15T15:29:00.287\",\"lastModified\":\"2024-11-21T03:38:43.630\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cross-site scripting vulnerability in multiple FXC Inc. network devices (Managed Ethernet switch FXC5210/5218/5224 firmware prior to version Ver1.00.22, Managed Ethernet switch FXC5426F firmware prior to version Ver1.00.06, Managed Ethernet switch FXC5428 firmware prior to version Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE firmware prior to version Ver1.00.14, and Wireless LAN router AE1021/AE1021PE firmware all versions) allows attacker with administrator rights to inject arbitrary web script or HTML via the administrative page.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad Cross-Site Scripting (XSS) en m\u00faltiples dispositivos de red de FXC Inc. (Managed Ethernet switch FXC5210/5218/5224 con firmware en versiones anteriores a la Ver1.00.22, Managed Ethernet switch FXC5426F con firmware en versiones anteriores a la Ver1.00.06, Managed Ethernet switch FXC5428 con firmware en versiones anteriores a la Ver1.00.07, Power over Ethernet (PoE) switch FXC5210PE/5218PE/5224PE con firmware en versiones anteriores a la Ver1.00.14 y Wireless LAN router AE1021/AE1021PE con firmware en todas las versiones) permite que un atacante con derechos de administrador inyecte scripts web o HTML arbitrarios mediante la p\u00e1gina administrativa.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5210_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.22\",\"matchCriteriaId\":\"72B8C77B-756B-4DBF-8642-9CEFA3E64FAB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5210:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C380189-64D0-4E67-A7BB-AAB484497E49\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5218_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.22\",\"matchCriteriaId\":\"A6BF9D0B-4A8E-4748-8F11-BA13560F4D16\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5218:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"22202750-42B2-49C4-913A-109E2B4A9ED2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5224_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.22\",\"matchCriteriaId\":\"C14B632E-AFB3-4768-B55D-AC174A0C2EB8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5224:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17C40735-948D-49FF-BEC1-8EC5840E75D1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5426f_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.06\",\"matchCriteriaId\":\"B8063D2B-DD96-4624-85DC-3A5707C94203\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5426f:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD2A9AE2-29E8-4662-881A-A4F9C83CF15D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5428_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.07\",\"matchCriteriaId\":\"9845D815-58C3-4138-8F75-36B559774F47\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5428:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CEB46925-3B3D-4980-8E32-B86E978BD13C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5210pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.14\",\"matchCriteriaId\":\"FFF6CC07-DBEF-48C8-9369-731FDED0835B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5210pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D6B7A903-7058-473F-B027-EC9408651BE9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5218pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.14\",\"matchCriteriaId\":\"EEB412D1-5C4D-4800-8C05-42AE9AE4495B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5218pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C568C89C-9A39-45EE-9345-2EB406AFF932\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:fxc5224pe_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.00.14\",\"matchCriteriaId\":\"66703C10-C292-438A-ADCF-6966DAF1002A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:fxc5224pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8077073-5A74-4512-86B1-1EB37E4C7928\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:ae1021_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"693C65D1-F2F8-4DC7-AA47-F9A0323AA118\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:ae1021:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"03B391D9-2AF4-4889-BFA3-52C11B4390C5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fxc:ae1021pe_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BC6562B5-862B-490D-8B2A-D0250CF5C63A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fxc:ae1021pe:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB758E1E-0CF5-4CA6-9A08-2B33BF296D67\"}]}]}],\"references\":[{\"url\":\"http://jvn.jp/en/jp/JVN68528150/index.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.fxc.jp/news/20171228.html\",\"source\":\"vultures@jpcert.or.jp\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"http://jvn.jp/en/jp/JVN68528150/index.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.fxc.jp/news/20171228.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]}]}}"
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.