CVE-2018-11229
Vulnerability from cvelistv5
Published
2018-06-08 01:00
Modified
2024-08-05 08:01
Severity ?
Summary
Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP).
Impacted products
n/an/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:01:52.667Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105051",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105051"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-06-07T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-08-14T09:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "105051",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105051"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-11229",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105051",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105051"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01"
            },
            {
              "name": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet",
              "refsource": "CONFIRM",
              "url": "https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-11229",
    "datePublished": "2018-06-08T01:00:00",
    "dateReserved": "2018-05-17T00:00:00",
    "dateUpdated": "2024-08-05T08:01:52.667Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-11229\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2018-06-08T01:29:00.997\",\"lastModified\":\"2019-05-13T18:31:15.047\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC, and TSW-560-NC devices before 2.001.0037.001 allow unauthenticated remote code execution via command injection in Crestron Toolbox Protocol (CTP).\"},{\"lang\":\"es\",\"value\":\"Los dispositivos Crestron TSW-1060, TSW-760, TSW-560, TSW-1060-NC, TSW-760-NC y TSW-560-NC en versiones anteriores a la 2.001.0037.001 permiten la ejecuci\u00f3n remota de c\u00f3digo sin autenticar mediante una inyecci\u00f3n de comandos en CTP (Crestron Toolbox Protocol).\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":7.5},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:crestron:crestron_toolbox_protocol_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.001.0037.001\",\"matchCriteriaId\":\"990FAF8F-A8B1-46B9-9C75-0ECF3A636B20\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:dmc-str:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"88961DC9-941C-480F-90EB-C572D0C0DD79\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-1060:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"199FB4DB-871C-422D-9082-C0C7F1E241CF\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-1060-nc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB8F6CD2-49B9-489E-9413-881D3D0DE791\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-560:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B107D415-5148-4323-A71E-AD694BE2CE16\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-560-nc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E44817F9-2CC7-4794-A0C0-8A9718AFA136\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-760:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BCDAF5B8-C9B3-49F9-A558-EFC89C918806\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:crestron:tsw-760-nc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD7F2F4A-7697-445A-A1B0-A66BA5DEC70A\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/105051\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-221-01\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://support.crestron.com/app/answers/answer_view/a_id/5471/~/the-latest-details-from-crestron-on-security-and-safety-on-the-internet\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.