CVE-2018-18999
Vulnerability from cvelistv5
Published
2018-12-19 18:00
Modified
2024-08-05 11:23
Severity ?
EPSS score ?
Summary
WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.securityfocus.com/bid/106245 | Third Party Advisory, VDB Entry | |
ics-cert@hq.dhs.gov | https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02 | Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.tenable.com/security/research/tra-2018-45 | Third Party Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | WebAccess/SCADA |
Version: WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T11:23:08.967Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.tenable.com/security/research/tra-2018-45" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "name": "106245", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/106245" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "WebAccess/SCADA", "vendor": "n/a", "versions": [ { "status": "affected", "version": "WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1" } ] } ], "datePublic": "2018-12-19T00:00:00", "descriptions": [ { "lang": "en", "value": "WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "IMPROPER INPUT VALIDATION CWE-20", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-20T10:57:01", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.tenable.com/security/research/tra-2018-45" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "name": "106245", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/106245" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2018-18999", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "WebAccess/SCADA", "version": { "version_data": [ { "version_value": "WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "IMPROPER INPUT VALIDATION CWE-20" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.tenable.com/security/research/tra-2018-45", "refsource": "MISC", "url": "https://www.tenable.com/security/research/tra-2018-45" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02" }, { "name": "106245", "refsource": "BID", "url": "http://www.securityfocus.com/bid/106245" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2018-18999", "datePublished": "2018-12-19T18:00:00", "dateReserved": "2018-11-06T00:00:00", "dateUpdated": "2024-08-05T11:23:08.967Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-18999\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2018-12-19T18:29:00.203\",\"lastModified\":\"2020-09-18T16:53:24.537\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.\"},{\"lang\":\"es\",\"value\":\"WebAccess/SCADA, WebAccess/SCADA en su versi\u00f3n 8.3.2 instalada en Windows 2008 R2 SP1. La falta de validaci\u00f3n adecuada de entradas proporcionadas por el usuario podr\u00eda permitir que un atacante provoque el desbordamiento de un b\u00fafer de la pila.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":7.5},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:advantech:webaccess\\\\/scada:8.3.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FD6FF92-F296-4E92-9CB4-8D99F7651FE3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:o:microsoft:windows_server_2008:r2:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"2ACA9287-B475-4AF7-A4DA-A7143CEF9E57\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/106245\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-352-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.tenable.com/security/research/tra-2018-45\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.