CVE-2018-4842
Vulnerability from cvelistv5
Published
2018-06-14 00:00
Modified
2024-08-05 05:18
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "104494",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "https://www.securityfocus.com/bid/104494"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.1"
            }
          ]
        },
        {
          "product": "SCALANCE X-200RNA switch family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        }
      ],
      "datePublic": "2018-06-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "104494",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://www.securityfocus.com/bid/104494"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4842",
    "datePublished": "2018-06-14T00:00:00",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-08-05T05:18:26.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-4842\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2018-06-14T16:29:00.397\",\"lastModified\":\"2022-12-13T17:15:11.860\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de conmutadores SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (todas las versiones inferiores a la versi\u00f3n V5.4.1), la familia de conmutadores SCALANCE X-300 (incluidas las variantes X408 y SIPLUS NET) (todas las versiones inferiores a la versi\u00f3n V4.1.3 ) Un atacante remoto y autenticado con acceso al servidor web de configuraci\u00f3n podr\u00eda almacenar el c\u00f3digo del script en el sitio web, si la opci\u00f3n de redundancia HRP est\u00e1 configurada. Este c\u00f3digo podr\u00eda ejecutarse en el navegador web de las v\u00edctimas que visitan este sitio web (XSS), afectando su confidencialidad, integridad y disponibilidad. La interacci\u00f3n del usuario es necesaria para una explotaci\u00f3n exitosa, ya que el usuario debe visitar el sitio web manipulado. En la etapa de publicaci\u00f3n de este aviso de seguridad no se conoce explotaci\u00f3n p\u00fablica. El proveedor ha confirmado la vulnerabilidad y proporciona mitigaciones para resolverla.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\",\"baseScore\":3.5},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x200irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.4.1\",\"matchCriteriaId\":\"7AA7D616-B6B3-4883-9EC2-ED08C8F22D99\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CAF3DA7A-6B80-4F20-835F-BF071197D1B0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x300_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E05BF7A-928C-4BF3-963F-7168037DFD51\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3F6299B-D7E3-4750-B016-7DCBC83C2287\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.3\",\"matchCriteriaId\":\"82699DAE-653E-4892-AABE-BD7EB0D08224\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A59C91EA-5D1B-4970-8C36-BD76BA420B12\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Mitigation\",\"Vendor Advisory\"]},{\"url\":\"https://www.securityfocus.com/bid/104494\",\"source\":\"productcert@siemens.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.