CVE-2018-6437
Vulnerability from cvelistv5
Published
2018-11-08 19:00
Modified
2024-08-05 06:01
Severity ?
EPSS score ?
Summary
A Vulnerability in the help command of Brocade Fabric OS command line interface (CLI) versions before 8.2.1, 8.1.2f, 8.0.2f, 7.4.2d could allow a local attacker to escape the restricted shell and, gain root access.
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Brocade Communications Systems, Inc. | Brocade Fabric OS |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T06:01:49.267Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-731" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Brocade Fabric OS", "vendor": "Brocade Communications Systems, Inc.", "versions": [ { "status": "affected", "version": "All versions prior to version 8.2.1, 8.1.2f, 8.0.2f, 7.4.2d" } ] } ], "datePublic": "2018-11-08T00:00:00", "descriptions": [ { "lang": "en", "value": "A Vulnerability in the help command of Brocade Fabric OS command line interface (CLI) versions before 8.2.1, 8.1.2f, 8.0.2f, 7.4.2d could allow a local attacker to escape the restricted shell and, gain root access." } ], "problemTypes": [ { "descriptions": [ { "description": "Privilege Escalation", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2018-11-08T18:57:01", "orgId": "87b297d7-335e-4844-9551-11b97995a791", "shortName": "brocade" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-731" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "sirt@brocade.com", "ID": "CVE-2018-6437", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Brocade Fabric OS", "version": { "version_data": [ { "version_value": "All versions prior to version 8.2.1, 8.1.2f, 8.0.2f, 7.4.2d" } ] } } ] }, "vendor_name": "Brocade Communications Systems, Inc." } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A Vulnerability in the help command of Brocade Fabric OS command line interface (CLI) versions before 8.2.1, 8.1.2f, 8.0.2f, 7.4.2d could allow a local attacker to escape the restricted shell and, gain root access." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Privilege Escalation" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-731", "refsource": "CONFIRM", "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-731" } ] } } } }, "cveMetadata": { "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791", "assignerShortName": "brocade", "cveId": "CVE-2018-6437", "datePublished": "2018-11-08T19:00:00", "dateReserved": "2018-01-31T00:00:00", "dateUpdated": "2024-08-05T06:01:49.267Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2018-6437\",\"sourceIdentifier\":\"sirt@brocade.com\",\"published\":\"2018-11-08T19:29:02.317\",\"lastModified\":\"2021-06-22T15:20:30.207\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A Vulnerability in the help command of Brocade Fabric OS command line interface (CLI) versions before 8.2.1, 8.1.2f, 8.0.2f, 7.4.2d could allow a local attacker to escape the restricted shell and, gain root access.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad en el comando help de las versiones de la interfaz de l\u00ednea de comandos (CLI) de Brocade Fabric OS en versiones anteriores a la 8.2.1, 8.1.2f, 8.0.2f, 8.4.2f y 7.4.2d podr\u00eda permitir que un atacante local escape de la shell restringida y obtenga acceso root.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.2},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.4.2\",\"versionEndExcluding\":\"7.4.2d\",\"matchCriteriaId\":\"A92A8875-D708-46CC-9758-E94551C9E809\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0.2\",\"versionEndExcluding\":\"8.0.2f\",\"matchCriteriaId\":\"1200CBDE-6179-45B9-A21A-D66341095B94\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.1.2\",\"versionEndExcluding\":\"8.1.2f\",\"matchCriteriaId\":\"E5782411-927C-43DD-A7B2-E114402715E0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.2.0\",\"versionEndExcluding\":\"8.2.1\",\"matchCriteriaId\":\"CD800AD8-1792-4D0B-BE9C-FDCE1BF6BE31\"}]}]}],\"references\":[{\"url\":\"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2018-731\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.