CVE-2018-6961 (GCVE-0-2018-6961)
Vulnerability from cvelistv5 – Published: 2018-06-11 22:00 – Updated: 2025-10-21 23:45
VLAI?
CISA
Summary
VMware NSX SD-WAN Edge by VeloCloud prior to version 3.1.0 contains a command injection vulnerability in the local web UI component. This component is disabled by default and should not be enabled on untrusted networks. VeloCloud by VMware will be removing this service from the product in future releases. Successful exploitation of this issue could result in remote code execution.
Severity ?
8.1 (High)
CWE
- Command Injection
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| VMware | NSX SD-WAN by VeloCloud |
Affected:
prior to version 3.1.0
|
CISA Known Exploited Vulnerability
Data from the CISA Known Exploited Vulnerabilities Catalog
Date added: 2022-03-25
Due date: 2022-04-15
Required action: Apply updates per vendor instructions.
Used in ransomware: Unknown
Notes: https://nvd.nist.gov/vuln/detail/CVE-2018-6961
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:17:17.275Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "104185",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/104185"
},
{
"name": "44959",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/44959/"
},
{
"name": "1041210",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1041210"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.vmware.com/security/advisories/VMSA-2018-0011.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2018-6961",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T13:12:59.138877Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2022-03-25",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-6961"
},
"type": "kev"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:45:50.384Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-6961"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-03-25T00:00:00+00:00",
"value": "CVE-2018-6961 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "NSX SD-WAN by VeloCloud",
"vendor": "VMware",
"versions": [
{
"status": "affected",
"version": "prior to version 3.1.0"
}
]
}
],
"datePublic": "2018-06-11T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "VMware NSX SD-WAN Edge by VeloCloud prior to version 3.1.0 contains a command injection vulnerability in the local web UI component. This component is disabled by default and should not be enabled on untrusted networks. VeloCloud by VMware will be removing this service from the product in future releases. Successful exploitation of this issue could result in remote code execution."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Command Injection",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-07-04T09:57:01.000Z",
"orgId": "dcf2e128-44bd-42ed-91e8-88f912c1401d",
"shortName": "vmware"
},
"references": [
{
"name": "104185",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/104185"
},
{
"name": "44959",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/44959/"
},
{
"name": "1041210",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1041210"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.vmware.com/security/advisories/VMSA-2018-0011.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@vmware.com",
"DATE_PUBLIC": "2018-06-11T00:00:00",
"ID": "CVE-2018-6961",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NSX SD-WAN by VeloCloud",
"version": {
"version_data": [
{
"version_value": "prior to version 3.1.0"
}
]
}
}
]
},
"vendor_name": "VMware"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "VMware NSX SD-WAN Edge by VeloCloud prior to version 3.1.0 contains a command injection vulnerability in the local web UI component. This component is disabled by default and should not be enabled on untrusted networks. VeloCloud by VMware will be removing this service from the product in future releases. Successful exploitation of this issue could result in remote code execution."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "104185",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/104185"
},
{
"name": "44959",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/44959/"
},
{
"name": "1041210",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1041210"
},
{
"name": "http://www.vmware.com/security/advisories/VMSA-2018-0011.html",
"refsource": "CONFIRM",
"url": "http://www.vmware.com/security/advisories/VMSA-2018-0011.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "dcf2e128-44bd-42ed-91e8-88f912c1401d",
"assignerShortName": "vmware",
"cveId": "CVE-2018-6961",
"datePublished": "2018-06-11T22:00:00.000Z",
"dateReserved": "2018-02-14T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:45:50.384Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"cisa_known_exploited": {
"cveID": "CVE-2018-6961",
"cwes": "[\"CWE-78\"]",
"dateAdded": "2022-03-25",
"dueDate": "2022-04-15",
"knownRansomwareCampaignUse": "Unknown",
"notes": "https://nvd.nist.gov/vuln/detail/CVE-2018-6961",
"product": "SD-WAN Edge",
"requiredAction": "Apply updates per vendor instructions.",
"shortDescription": "VMware SD-WAN Edge by VeloCloud contains a command injection vulnerability in the local web UI component. Successful exploitation of this issue could result in remote code execution.",
"vendorProject": "VMware",
"vulnerabilityName": "VMware SD-WAN Edge by VeloCloud Command Injection Vulnerability"
},
"fkie_nvd": {
"cisaActionDue": "2022-04-15",
"cisaExploitAdd": "2022-03-25",
"cisaRequiredAction": "Apply updates per vendor instructions.",
"cisaVulnerabilityName": "VMware SD-WAN Edge by VeloCloud Command Injection Vulnerability",
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:vmware:nsx_sd-wan_by_velocloud:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.1.0\", \"matchCriteriaId\": \"FCA5E588-75D4-401D-B486-9CA8F3A5E8A0\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"VMware NSX SD-WAN Edge by VeloCloud prior to version 3.1.0 contains a command injection vulnerability in the local web UI component. This component is disabled by default and should not be enabled on untrusted networks. VeloCloud by VMware will be removing this service from the product in future releases. Successful exploitation of this issue could result in remote code execution.\"}, {\"lang\": \"es\", \"value\": \"VMware NSX SD-WAN Edge by VeloCloud en versiones anteriores a la 3.1.0 contiene una vulnerabilidad de inyecci\\u00f3n de comandos en el componente local web UI. Este componente est\\u00e1 deshabilitado por defecto y no se deber\\u00eda habilitar en redes no fiables. VeloCloud by VMware eliminar\\u00e1 este servicio del producto en futuras versiones. Una explotaci\\u00f3n exitosa de esta vulnerabilidad podr\\u00eda resultar en una ejecuci\\u00f3n remota de c\\u00f3digo.\"}]",
"id": "CVE-2018-6961",
"lastModified": "2024-11-21T04:11:29.293",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2018-06-11T22:29:00.230",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/104185\", \"source\": \"security@vmware.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1041210\", \"source\": \"security@vmware.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\", \"source\": \"security@vmware.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.exploit-db.com/exploits/44959/\", \"source\": \"security@vmware.com\", \"tags\": [\"Exploit\", \"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securityfocus.com/bid/104185\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1041210\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.exploit-db.com/exploits/44959/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "security@vmware.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-6961\",\"sourceIdentifier\":\"security@vmware.com\",\"published\":\"2018-06-11T22:29:00.230\",\"lastModified\":\"2025-10-30T20:07:45.157\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"VMware NSX SD-WAN Edge by VeloCloud prior to version 3.1.0 contains a command injection vulnerability in the local web UI component. This component is disabled by default and should not be enabled on untrusted networks. VeloCloud by VMware will be removing this service from the product in future releases. Successful exploitation of this issue could result in remote code execution.\"},{\"lang\":\"es\",\"value\":\"VMware NSX SD-WAN Edge by VeloCloud en versiones anteriores a la 3.1.0 contiene una vulnerabilidad de inyecci\u00f3n de comandos en el componente local web UI. Este componente est\u00e1 deshabilitado por defecto y no se deber\u00eda habilitar en redes no fiables. VeloCloud by VMware eliminar\u00e1 este servicio del producto en futuras versiones. Una explotaci\u00f3n exitosa de esta vulnerabilidad podr\u00eda resultar en una ejecuci\u00f3n remota de c\u00f3digo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"cisaExploitAdd\":\"2022-03-25\",\"cisaActionDue\":\"2022-04-15\",\"cisaRequiredAction\":\"Apply updates per vendor instructions.\",\"cisaVulnerabilityName\":\"VMware SD-WAN Edge by VeloCloud Command Injection Vulnerability\",\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:vmware:nsx_sd-wan_by_velocloud:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.1.0\",\"matchCriteriaId\":\"FCA5E588-75D4-401D-B486-9CA8F3A5E8A0\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/104185\",\"source\":\"security@vmware.com\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1041210\",\"source\":\"security@vmware.com\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\",\"source\":\"security@vmware.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.exploit-db.com/exploits/44959/\",\"source\":\"security@vmware.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securityfocus.com/bid/104185\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1041210\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.exploit-db.com/exploits/44959/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-6961\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"US Government Resource\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"http://www.securityfocus.com/bid/104185\", \"name\": \"104185\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\", \"x_transferred\"]}, {\"url\": \"https://www.exploit-db.com/exploits/44959/\", \"name\": \"44959\", \"tags\": [\"exploit\", \"x_refsource_EXPLOIT-DB\", \"x_transferred\"]}, {\"url\": \"http://www.securitytracker.com/id/1041210\", \"name\": \"1041210\", \"tags\": [\"vdb-entry\", \"x_refsource_SECTRACK\", \"x_transferred\"]}, {\"url\": \"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T06:17:17.275Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 8.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2018-6961\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"active\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-02-07T13:12:59.138877Z\"}}}, {\"other\": {\"type\": \"kev\", \"content\": {\"dateAdded\": \"2022-03-25\", \"reference\": \"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-6961\"}}}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2022-03-25T00:00:00+00:00\", \"value\": \"CVE-2018-6961 added to CISA KEV\"}], \"references\": [{\"url\": \"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-6961\", \"tags\": [\"government-resource\"]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-07T13:12:58.543Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"VMware\", \"product\": \"NSX SD-WAN by VeloCloud\", \"versions\": [{\"status\": \"affected\", \"version\": \"prior to version 3.1.0\"}]}], \"datePublic\": \"2018-06-11T00:00:00.000Z\", \"references\": [{\"url\": \"http://www.securityfocus.com/bid/104185\", \"name\": \"104185\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\"]}, {\"url\": \"https://www.exploit-db.com/exploits/44959/\", \"name\": \"44959\", \"tags\": [\"exploit\", \"x_refsource_EXPLOIT-DB\"]}, {\"url\": \"http://www.securitytracker.com/id/1041210\", \"name\": \"1041210\", \"tags\": [\"vdb-entry\", \"x_refsource_SECTRACK\"]}, {\"url\": \"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\", \"tags\": [\"x_refsource_CONFIRM\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"VMware NSX SD-WAN Edge by VeloCloud prior to version 3.1.0 contains a command injection vulnerability in the local web UI component. This component is disabled by default and should not be enabled on untrusted networks. VeloCloud by VMware will be removing this service from the product in future releases. Successful exploitation of this issue could result in remote code execution.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"dcf2e128-44bd-42ed-91e8-88f912c1401d\", \"shortName\": \"vmware\", \"dateUpdated\": \"2018-07-04T09:57:01.000Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"prior to version 3.1.0\"}]}, \"product_name\": \"NSX SD-WAN by VeloCloud\"}]}, \"vendor_name\": \"VMware\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"http://www.securityfocus.com/bid/104185\", \"name\": \"104185\", \"refsource\": \"BID\"}, {\"url\": \"https://www.exploit-db.com/exploits/44959/\", \"name\": \"44959\", \"refsource\": \"EXPLOIT-DB\"}, {\"url\": \"http://www.securitytracker.com/id/1041210\", \"name\": \"1041210\", \"refsource\": \"SECTRACK\"}, {\"url\": \"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\", \"name\": \"http://www.vmware.com/security/advisories/VMSA-2018-0011.html\", \"refsource\": \"CONFIRM\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"VMware NSX SD-WAN Edge by VeloCloud prior to version 3.1.0 contains a command injection vulnerability in the local web UI component. This component is disabled by default and should not be enabled on untrusted networks. VeloCloud by VMware will be removing this service from the product in future releases. Successful exploitation of this issue could result in remote code execution.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"Command Injection\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2018-6961\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"security@vmware.com\", \"DATE_PUBLIC\": \"2018-06-11T00:00:00\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2018-6961\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-21T23:45:50.384Z\", \"dateReserved\": \"2018-02-14T00:00:00.000Z\", \"assignerOrgId\": \"dcf2e128-44bd-42ed-91e8-88f912c1401d\", \"datePublished\": \"2018-06-11T22:00:00.000Z\", \"assignerShortName\": \"vmware\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…