CVE-2019-10917
Vulnerability from cvelistv5
Published
2019-05-14 19:54
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.224Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC PCS 7 V8.0 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.1",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V8.2",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC PCS 7 V9.0",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Upd 9"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal) V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V13",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V14",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14.1 Upd 8"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional V15",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1 Upd 3"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.2 and earlier",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.3",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.3 Upd 19"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.4",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.4 SP1 Upd 11"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V7.5 Upd 3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-248",
              "description": "CWE-248: Uncaught Exception",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-23T19:28:02",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10917",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC PCS 7 V8.0 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.1",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.1 with WinCC V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V8.2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC PCS 7 V9.0",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Upd 9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V13",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14.1 Upd 8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V15.1 Upd 3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.2 and earlier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.3 Upd 19"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.4 SP1 Upd 11"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC V7.5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V7.5 Upd 3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-248: Uncaught Exception"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-08"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10917",
    "datePublished": "2019-05-14T19:54:48",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.224Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-10917\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2019-05-14T20:29:02.387\",\"lastModified\":\"2021-11-02T19:30:50.800\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions \u003c V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions \u003c V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions \u003c V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.0 y anteriores (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones anteriores a la versi\u00f3n V8.1 con WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (Todas las versiones anteriores V8.2 SP1 con WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (Todas las versiones  anteriores a la versi\u00f3n V9.0 SP2 con WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones \"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":2.1},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-755\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-248\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.0\",\"matchCriteriaId\":\"78F045C4-8DC2-4FA8-833D-B430EA26F2A0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"858628AC-EA69-4D72-AE23-77A4A8DE2547\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4A75F15-8F47-4348-A85C-D94BBA8F9992\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3F27A96F-58B7-492F-8CF7-DE04D4EDAAD8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.2\",\"matchCriteriaId\":\"23B89914-E5BA-4670-B692-092AE9FFE148\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D6229A2-9B8E-4F76-8425-589D2CE58B16\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F64B795A-7E66-49AE-BE40-E8EEAC12D280\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):13.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3D1A823-CE50-441F-B060-DA678DFE24FD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):14.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"28A1BA01-7A92-4368-8A73-8FA47A08BC53\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_\\\\(tia_portal\\\\):15.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0256663E-3A97-4E99-995D-7446804DB496\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E07DBA91-379C-40F5-8C45-6EC302F5CA7D\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/ICSA-19-134-08\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.