A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains a directory traversal vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker with network access to the CCS server could exploit this vulnerability to list arbitrary directories or read files outside of the CCS application context.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-01-16 20:16 UTC
CWE
  • CWE-23 - Relative Path Traversal
References
Impacted products
Vendor Product Version CPE status
Siemens Control Center Server (CCS) Affected: All versions < V1.5.0
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:54:13.984Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-18338",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-01-16T20:16:01.878394Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-15T14:50:03.991Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Control Center Server (CCS)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The Control Center Server (CCS) contains a directory traversal\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\n\nAn authenticated remote attacker with network access to the CCS server\ncould exploit this vulnerability to list arbitrary directories\nor read files outside of the CCS application context."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:F/RL:U/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T09:56:12.210Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-18338",
    "datePublished": "2019-12-12T19:08:49.000Z",
    "dateReserved": "2019-10-23T00:00:00.000Z",
    "dateUpdated": "2024-11-15T14:50:03.991Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-18338",
      "date": "2026-10-01",
      "epss": "0.02647",
      "percentile": "0.85079"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "16668E9A-2D0A-425E-87F4-18CFC50551D3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F21BB6D-BFE0-4B69-97F2-1A871A390B1E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The Control Center Server (CCS) contains a directory traversal\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\n\nAn authenticated remote attacker with network access to the CCS server\ncould exploit this vulnerability to list arbitrary directories\nor read files outside of the CCS application context."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en Control Center Server (CCS) (Todas las versiones anteriores a V1.5.0). El Servidor de Control Center (CCS) contiene una vulnerabilidad de traspaso de directorios en su protocolo de comunicaci\u00f3n basado en XML proporcionado por defecto en los puertos 5444/tcp y 5440/tcp. Un atacante remoto autentificado con acceso a la red del servidor CCS podr\u00eda explotar esta vulnerabilidad para listar directorios arbitrarios o leer archivos fuera del contexto de la aplicaci\u00f3n CCS"
        }
      ],
      "id": "CVE-2019-18338",
      "lastModified": "2024-11-21T04:33:04.620",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "SINGLE",
              "availabilityImpact": "NONE",
              "baseScore": 4.0,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 8.0,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.7,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 3.1,
            "impactScore": 4.0,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2019-12-12T19:15:20.327",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-23"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-22"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "16668E9A-2D0A-425E-87F4-18CFC50551D3",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0F21BB6D-BFE0-4B69-97F2-1A871A390B1E",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The Control Center Server (CCS) contains a directory traversal\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\n\nAn authenticated remote attacker with network access to the CCS server\ncould exploit this vulnerability to list arbitrary directories\nor read files outside of the CCS application context."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en Control Center Server (CCS) (Todas las versiones anteriores a V1.5.0). El Servidor de Control Center (CCS) contiene una vulnerabilidad de traspaso de directorios en su protocolo de comunicaci\u00f3n basado en XML proporcionado por defecto en los puertos 5444/tcp y 5440/tcp. Un atacante remoto autentificado con acceso a la red del servidor CCS podr\u00eda explotar esta vulnerabilidad para listar directorios arbitrarios o leer archivos fuera del contexto de la aplicaci\u00f3n CCS"
          }
        ],
        "id": "CVE-2019-18338",
        "lastModified": "2024-11-21T04:33:04.620",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "availabilityImpact": "NONE",
                "baseScore": 4.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.1,
              "impactScore": 4.0,
              "source": "productcert@siemens.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Secondary"
            }
          ]
        },
        "published": "2019-12-12T19:15:20.327",
        "references": [
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
          },
          {
            "source": "productcert@siemens.com",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-23"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-22"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T01:54:13.984Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-18338",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-01-16T20:16:01.878394Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-15T14:49:58.923Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Control Center Server (CCS)",
              "vendor": "Siemens",
              "versions": [
                {
                  "status": "affected",
                  "version": "All versions \u003c V1.5.0"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The Control Center Server (CCS) contains a directory traversal\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\n\nAn authenticated remote attacker with network access to the CCS server\ncould exploit this vulnerability to list arbitrary directories\nor read files outside of the CCS application context."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N/E:F/RL:U/RC:C",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-23",
                  "description": "CWE-23: Relative Path Traversal",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-01-09T09:56:12.210Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2019-18338",
        "datePublished": "2019-12-12T19:08:49.000Z",
        "dateReserved": "2019-10-23T00:00:00.000Z",
        "dateUpdated": "2024-11-15T14:50:03.991Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…