CVE-2019-18340 (GCVE-0-2019-18340)

Vulnerability from cvelistv5 – Published: 2019-12-12 19:08 – Updated: 2024-08-05 01:54
VLAI
Summary
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), Control Center Server (CCS) (All versions >= V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store user and device passwords by applying weak cryptography. A local attacker could exploit this vulnerability to extract the passwords from the user database and/or the device configuration files to conduct further attacks.
CWE
  • CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
siemens CNA under the icscert root
CNA scorecard C 65/100 over 100 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
Siemens Control Center Server (CCS) Affected: All versions < V1.5.0
guessed Create a notification for this product.
Siemens Control Center Server (CCS) Affected: All versions >= V1.5.0
guessed Create a notification for this product.
Siemens SiNVR/SiVMS Video Server Affected: All versions < V5.0.0
guessed Create a notification for this product.
Siemens SiNVR/SiVMS Video Server Affected: All versions >= V5.0.0
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:54:14.118Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Control Center Server (CCS)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Control Center Server (CCS)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V1.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SiNVR/SiVMS Video Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SiNVR/SiVMS Video Server",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V5.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), Control Center Server (CCS) (All versions \u003e= V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store\nuser and device passwords by applying weak cryptography.\n\nA local attacker could exploit this vulnerability to extract\nthe passwords from the user database and/or the device configuration files\nto conduct further attacks."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:F/RL:U/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-01-09T09:56:14.606Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-18340",
    "datePublished": "2019-12-12T19:08:49.000Z",
    "dateReserved": "2019-10-23T00:00:00.000Z",
    "dateUpdated": "2024-08-05T01:54:14.118Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-18340",
      "date": "2026-10-31",
      "epss": "0.0025",
      "percentile": "0.16446"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "16668E9A-2D0A-425E-87F4-18CFC50551D3",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0F21BB6D-BFE0-4B69-97F2-1A871A390B1E",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), Control Center Server (CCS) (All versions \u003e= V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store\nuser and device passwords by applying weak cryptography.\n\nA local attacker could exploit this vulnerability to extract\nthe passwords from the user database and/or the device configuration files\nto conduct further attacks."
        },
        {
          "lang": "es",
          "value": "Se ha identificado una vulnerabilidad en Central Control Server (CCS) (Todas las versiones anteriores a V1.5.0), Control Center Server (CCS) (Todas las versiones anteriores o iguales a V1.5.0), SiNVR/SiVMS Video Server (Todas las versiones anteriores a V5.0.0). Tanto el servidor de video SiVMS/SiNVR 3 como el Central Control Server (CCS) almacenan las contrase\u00f1as de usuarios y dispositivos mediante una aplicaci\u00f3n de criptograf\u00eda d\u00e9bil. Un atacante local podr\u00eda explotar esta vulnerabilidad para extraer las contrase\u00f1as de la base de datos del usuario y/o los archivos de configuraci\u00f3n del dispositivo para conducir nuevos ataques adicionales."
        }
      ],
      "id": "CVE-2019-18340",
      "lastModified": "2024-11-21T04:33:04.860",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "LOW",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "LOCAL",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 2.1,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "NONE",
              "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 2.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "productcert@siemens.com",
            "type": "Secondary"
          },
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "NONE",
              "baseScore": 5.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            },
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      },
      "published": "2019-12-12T19:15:20.560",
      "references": [
        {
          "source": "productcert@siemens.com",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
        },
        {
          "source": "productcert@siemens.com",
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
        }
      ],
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-327"
            }
          ],
          "source": "productcert@siemens.com",
          "type": "Primary"
        },
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-327"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Secondary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "16668E9A-2D0A-425E-87F4-18CFC50551D3",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0F21BB6D-BFE0-4B69-97F2-1A871A390B1E",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), Control Center Server (CCS) (All versions \u003e= V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store\nuser and device passwords by applying weak cryptography.\n\nA local attacker could exploit this vulnerability to extract\nthe passwords from the user database and/or the device configuration files\nto conduct further attacks."
          },
          {
            "lang": "es",
            "value": "Se ha identificado una vulnerabilidad en Central Control Server (CCS) (Todas las versiones anteriores a V1.5.0), Control Center Server (CCS) (Todas las versiones anteriores o iguales a V1.5.0), SiNVR/SiVMS Video Server (Todas las versiones anteriores a V5.0.0). Tanto el servidor de video SiVMS/SiNVR 3 como el Central Control Server (CCS) almacenan las contrase\u00f1as de usuarios y dispositivos mediante una aplicaci\u00f3n de criptograf\u00eda d\u00e9bil. Un atacante local podr\u00eda explotar esta vulnerabilidad para extraer las contrase\u00f1as de la base de datos del usuario y/o los archivos de configuraci\u00f3n del dispositivo para conducir nuevos ataques adicionales."
          }
        ],
        "id": "CVE-2019-18340",
        "lastModified": "2024-11-21T04:33:04.860",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "LOW",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 2.1,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "productcert@siemens.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Secondary"
            }
          ]
        },
        "published": "2019-12-12T19:15:20.560",
        "references": [
          {
            "source": "productcert@siemens.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
          },
          {
            "source": "productcert@siemens.com",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
          }
        ],
        "sourceIdentifier": "productcert@siemens.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-327"
              }
            ],
            "source": "productcert@siemens.com",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-327"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.