CVE-2019-20721
Vulnerability from cvelistv5
Published
2020-04-16 16:19
Modified
2024-08-05 02:53
Severity ?
EPSS score ?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:53:07.558Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-16T16:19:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-20721", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-20721", "datePublished": "2020-04-16T16:19:28", "dateReserved": "2020-04-15T00:00:00", "dateUpdated": "2024-08-05T02:53:07.558Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.47\", \"matchCriteriaId\": \"BEF729AE-1D95-448C-80FA-8FAE723C1EC3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DA2D4987-3726-4A72-8D32-592F59FAC46D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.48\", \"matchCriteriaId\": \"733650A8-D797-43B2-851E-1B364C9E7100\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5341B659-DE7D-43F1-954D-82049CBE18AD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.76\", \"matchCriteriaId\": \"CC89483B-6D99-4A1B-A513-B50EA44DA963\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"88DD070C-7CBD-48A5-8D77-7C3D1C502D65\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.76\", \"matchCriteriaId\": \"542F7529-27DB-41F1-A8E4-FA7A596E5DCC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"49846803-C6FB-4DD3-ADA7-78B9923536F2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.72\", \"matchCriteriaId\": \"3223C7E1-06DF-4CAA-89DD-611435165F49\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B4F62287-CB55-4FB1-AA39-62018654BA39\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.136\", \"matchCriteriaId\": \"E0A1B4BD-9DD6-4999-B0FA-F843713C991F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1289BBB4-1955-46A4-B5FE-BF11153C24F5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.136\", \"matchCriteriaId\": \"2138C164-530B-4F97-8107-035F9D0852B0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F285D60D-A5DA-4467-8F79-15EF8135D007\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.3.38\", \"matchCriteriaId\": \"536487B8-FF04-4526-BE91-44437256525C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.52\", \"matchCriteriaId\": \"2C2195F1-18F6-4397-9D28-7A92003B7A76\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17CF7445-6950-45FE-9D1A-E23F63316329\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.4.12\", \"matchCriteriaId\": \"E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0F859165-8D89-4CDD-9D48-9C7923D2261F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.4.12\", \"matchCriteriaId\": \"F1F914AD-70DC-47F5-A2F7-672DBE89C62E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.32\", \"matchCriteriaId\": \"317AE6B1-BA33-49DF-A839-A49C5493996E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6FB1BE0D-E3CF-4C16-8C11-706B238E9934\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.68\", \"matchCriteriaId\": \"663F925A-642C-4E4A-9D27-76B6EF6978F6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3DAD97C7-458D-4547-82A4-EC7F4CFB2A90\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.70\", \"matchCriteriaId\": \"DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.66\", \"matchCriteriaId\": \"A480981E-57ED-47E3-B9AB-190E4783DC04\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4D8680F5-0C06-4CFC-8BA0-CF85D0438419\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.58\", \"matchCriteriaId\": \"1DA490CC-DB27-4817-A589-61A0D221E9FD\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4428B145-B86D-4709-BBA9-64BDE7D35A25\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.58\", \"matchCriteriaId\": \"652D8CA8-B56A-4403-B072-B4C245AB8EDA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C31D6808-4103-4543-B7AB-84A79CD12006\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3.2.32\", \"matchCriteriaId\": \"804E18F1-4621-4650-9015-49A9137A0C39\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.3.2.32\", \"matchCriteriaId\": \"29216B3A-9A3B-4752-99C2-4A9CFA8E5E26\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.66\", \"matchCriteriaId\": \"9F3D02E3-8FA1-4129-A4B2-25235AF0E49C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"317F25FF-B3A2-4C68-888F-D2627C564867\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32.\"}, {\"lang\": \"es\", \"value\": \"Determinados dispositivos NETGEAR est\\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D7800 versiones anteriores a 1.0.1.47, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7300 versiones anteriores a 1.0.2.136, R7500v2 versiones anteriores a 1.0.3.38, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4. 12, R9000 versiones anteriores a 1.0.4.12, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1.0.2.70, WN3100RPv2 versiones anteriores a 1.0.0. 66, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.66, XR450 versiones anteriores a 2.3.2.32, y XR500 versiones anteriores a 2.3.2.32.\"}]", "id": "CVE-2019-20721", "lastModified": "2024-11-21T04:39:10.943", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 4.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 2.7}], \"cvssMetricV30\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N\", \"baseScore\": 4.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}", "published": "2020-04-16T19:15:25.227", "references": "[{\"url\": \"https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2019-20721\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-04-16T19:15:25.227\",\"lastModified\":\"2024-11-21T04:39:10.943\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by stored XSS. This affects D7800 before 1.0.1.47, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX6400 before 1.0.2.136, EX7300 before 1.0.2.136, R7500v2 before 1.0.3.38, R7800 before 1.0.2.52, R8900 before 1.0.4.12, R9000 before 1.0.4.12, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, WNR2000v5 before 1.0.0.66, XR450 before 2.3.2.32, and XR500 before 2.3.2.32.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a D7800 versiones anteriores a 1.0.1.47, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.72, EX6400 versiones anteriores a 1.0.2.136, EX7300 versiones anteriores a 1.0.2.136, R7500v2 versiones anteriores a 1.0.3.38, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0.4. 12, R9000 versiones anteriores a 1.0.4.12, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1.0.2.70, WN3100RPv2 versiones anteriores a 1.0.0. 66, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, WNR2000v5 versiones anteriores a 1.0.0.66, XR450 versiones anteriores a 2.3.2.32, y XR500 versiones anteriores a 2.3.2.32.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.47\",\"matchCriteriaId\":\"BEF729AE-1D95-448C-80FA-8FAE723C1EC3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA2D4987-3726-4A72-8D32-592F59FAC46D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.48\",\"matchCriteriaId\":\"733650A8-D797-43B2-851E-1B364C9E7100\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5341B659-DE7D-43F1-954D-82049CBE18AD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.76\",\"matchCriteriaId\":\"CC89483B-6D99-4A1B-A513-B50EA44DA963\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"88DD070C-7CBD-48A5-8D77-7C3D1C502D65\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.76\",\"matchCriteriaId\":\"542F7529-27DB-41F1-A8E4-FA7A596E5DCC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"49846803-C6FB-4DD3-ADA7-78B9923536F2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.72\",\"matchCriteriaId\":\"3223C7E1-06DF-4CAA-89DD-611435165F49\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4F62287-CB55-4FB1-AA39-62018654BA39\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.136\",\"matchCriteriaId\":\"E0A1B4BD-9DD6-4999-B0FA-F843713C991F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1289BBB4-1955-46A4-B5FE-BF11153C24F5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.136\",\"matchCriteriaId\":\"2138C164-530B-4F97-8107-035F9D0852B0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F285D60D-A5DA-4467-8F79-15EF8135D007\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.3.38\",\"matchCriteriaId\":\"536487B8-FF04-4526-BE91-44437256525C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.52\",\"matchCriteriaId\":\"2C2195F1-18F6-4397-9D28-7A92003B7A76\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17CF7445-6950-45FE-9D1A-E23F63316329\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.4.12\",\"matchCriteriaId\":\"E5AC056A-DF92-4CA7-9919-2C9BDAE3C32D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F859165-8D89-4CDD-9D48-9C7923D2261F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.4.12\",\"matchCriteriaId\":\"F1F914AD-70DC-47F5-A2F7-672DBE89C62E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.32\",\"matchCriteriaId\":\"317AE6B1-BA33-49DF-A839-A49C5493996E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FB1BE0D-E3CF-4C16-8C11-706B238E9934\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.68\",\"matchCriteriaId\":\"663F925A-642C-4E4A-9D27-76B6EF6978F6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3DAD97C7-458D-4547-82A4-EC7F4CFB2A90\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.70\",\"matchCriteriaId\":\"DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.66\",\"matchCriteriaId\":\"A480981E-57ED-47E3-B9AB-190E4783DC04\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D8680F5-0C06-4CFC-8BA0-CF85D0438419\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.58\",\"matchCriteriaId\":\"1DA490CC-DB27-4817-A589-61A0D221E9FD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4428B145-B86D-4709-BBA9-64BDE7D35A25\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.58\",\"matchCriteriaId\":\"652D8CA8-B56A-4403-B072-B4C245AB8EDA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C31D6808-4103-4543-B7AB-84A79CD12006\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3.2.32\",\"matchCriteriaId\":\"804E18F1-4621-4650-9015-49A9137A0C39\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3.2.32\",\"matchCriteriaId\":\"29216B3A-9A3B-4752-99C2-4A9CFA8E5E26\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.66\",\"matchCriteriaId\":\"9F3D02E3-8FA1-4129-A4B2-25235AF0E49C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"317F25FF-B3A2-4C68-888F-D2627C564867\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://kb.netgear.com/000061207/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Gateways-and-Extenders-PSV-2018-0159\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.