CVE-2019-8276 (GCVE-0-2019-8276)
Vulnerability from cvelistv5 – Published: 2019-03-09 00:00 – Updated: 2024-09-16 18:33- CWE-121 - Stack-based Buffer Overflow
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Kaspersky Lab | UltraVNC |
Affected:
1.2.2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T21:17:30.806Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UltraVNC",
"vendor": "Kaspersky Lab",
"versions": [
{
"status": "affected",
"version": "1.2.2.3"
}
]
}
],
"datePublic": "2019-03-01T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-06-12T20:55:54",
"orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"shortName": "Kaspersky"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8276",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
"assignerShortName": "Kaspersky",
"cveId": "CVE-2019-8276",
"datePublished": "2019-03-09T00:00:00Z",
"dateReserved": "2019-02-12T00:00:00",
"dateUpdated": "2024-09-16T18:33:31.486Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.2.2.3\", \"matchCriteriaId\": \"555D034F-3D64-4ED1-9B63-F8D59199E99C\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinumerik_access_mymachine\\\\/p2p:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.8\", \"matchCriteriaId\": \"D9345335-DF62-4472-93CD-E2C85453F91E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\\\/ipc:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"14.00\", \"matchCriteriaId\": \"7498412D-79FD-43FE-AD9B-5820FB5CF7D8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\\\/ipc:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"12.01\", \"matchCriteriaId\": \"1F603341-03C5-46CA-8A74-EC5A50135194\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.\"}, {\"lang\": \"es\", \"value\": \"UltraVNC, en su revisi\\u00f3n 1211, tiene una vulnerabilidad de desbordamiento de b\\u00fafer basado en pila en el c\\u00f3digo del servidor VNC dentro del manipulador de peticiones de trasferencia de datos, lo que puede resultar en una denegaci\\u00f3n de servicio (DoS). Este ataque parece ser explotable mediante la conectividad de red. Esta vulnerabilidad se ha solucionado en la revisi\\u00f3n 1212.\"}]",
"id": "CVE-2019-8276",
"lastModified": "2024-11-21T04:49:37.950",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-03-08T23:29:00.937",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\", \"source\": \"vulnerability@kaspersky.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/\", \"source\": \"vulnerability@kaspersky.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\", \"source\": \"vulnerability@kaspersky.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "vulnerability@kaspersky.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"vulnerability@kaspersky.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-121\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-8276\",\"sourceIdentifier\":\"vulnerability@kaspersky.com\",\"published\":\"2019-03-08T23:29:00.937\",\"lastModified\":\"2024-11-21T04:49:37.950\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.\"},{\"lang\":\"es\",\"value\":\"UltraVNC, en su revisi\u00f3n 1211, tiene una vulnerabilidad de desbordamiento de b\u00fafer basado en pila en el c\u00f3digo del servidor VNC dentro del manipulador de peticiones de trasferencia de datos, lo que puede resultar en una denegaci\u00f3n de servicio (DoS). Este ataque parece ser explotable mediante la conectividad de red. Esta vulnerabilidad se ha solucionado en la revisi\u00f3n 1212.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"vulnerability@kaspersky.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.2.2.3\",\"matchCriteriaId\":\"555D034F-3D64-4ED1-9B63-F8D59199E99C\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_access_mymachine\\\\/p2p:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.8\",\"matchCriteriaId\":\"D9345335-DF62-4472-93CD-E2C85453F91E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\\\/ipc:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"14.00\",\"matchCriteriaId\":\"7498412D-79FD-43FE-AD9B-5820FB5CF7D8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\\\/ipc:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"12.01\",\"matchCriteriaId\":\"1F603341-03C5-46CA-8A74-EC5A50135194\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\",\"source\":\"vulnerability@kaspersky.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/\",\"source\":\"vulnerability@kaspersky.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\",\"source\":\"vulnerability@kaspersky.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-20-161-06\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
CERTFR-2020-AVI-349
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC PDM | ||
| Siemens | N/A | SIMATIC WinCC OA V3.17 versions antérieures à V3.17-P003 | ||
| Siemens | N/A | SINUMERIK PCU base Win7 software /IPC versions antérieures à V12.01 HF4 | ||
| Siemens | N/A | SIMATIC NET PC versions antérieures à V16 Upd3 | ||
| Siemens | N/A | SIMATIC WinCC OA V3.16 versions antérieures à V3.16-P018 | ||
| Siemens | N/A | SINEC NMS sans le dernier correctif de sécurité | ||
| Siemens | N/A | SIMATIC PCS 7 | ||
| Siemens | N/A | LOGO!8 BM | ||
| Siemens | N/A | SIMATIC S7-1500 | ||
| Siemens | N/A | SINUMERIK Operate | ||
| Siemens | N/A | SINEMA Server sans le dernier correctif de sécurité | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced | ||
| Siemens | N/A | SIMATIC Automation Tool | ||
| Siemens | N/A | SINUMERIK ONE virtual | ||
| Siemens | N/A | SIMATIC ProSave | ||
| Siemens | N/A | SIMATIC WinCC V7.5 versions antérieures à V7.5 SP1 Update 3 | ||
| Siemens | N/A | SINAMICS STARTER commissioning tool | ||
| Siemens | N/A | SIMATIC WinCC Runtime Professional V13, V14, V15 et V16 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) V13, V14, V15 et V16 | ||
| Siemens | N/A | SIMATIC PCS neo | ||
| Siemens | N/A | SINAMICS Startdrive | ||
| Siemens | N/A | SINAMICS STARTER versions antérieures à V5.4 HF1 | ||
| Siemens | N/A | SIMATIC WinCC V7.4 versions antérieures à V7.4 SP1 Update 14 | ||
| Siemens | N/A | SIMATIC STEP 7 versions antérieures à V5.6 SP2 HF3 | ||
| Siemens | N/A | SINUMERIK Access MyMachine /P2P versions antérieures à V4.8 | ||
| Siemens | N/A | SINUMERIK PCU base Win10 software /IPC versions antérieures à V14.00 |
| Title | Publication Time | Tags | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC PDM",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA V3.17 versions ant\u00e9rieures \u00e0 V3.17-P003",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK PCU base Win7 software /IPC versions ant\u00e9rieures \u00e0 V12.01 HF4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC versions ant\u00e9rieures \u00e0 V16 Upd3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA V3.16 versions ant\u00e9rieures \u00e0 V3.16-P018",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC NMS sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO!8 BM",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Operate",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Server sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Automation Tool",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK ONE virtual",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ProSave",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.5 versions ant\u00e9rieures \u00e0 V7.5 SP1 Update 3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS STARTER commissioning tool",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Professional V13, V14, V15 et V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) V13, V14, V15 et V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS Startdrive",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS STARTER versions ant\u00e9rieures \u00e0 V5.4 HF1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.4 versions ant\u00e9rieures \u00e0 V7.4 SP1 Update 14",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 versions ant\u00e9rieures \u00e0 V5.6 SP2 HF3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Access MyMachine /P2P versions ant\u00e9rieures \u00e0 V4.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK PCU base Win10 software /IPC versions ant\u00e9rieures \u00e0 V14.00",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7589",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7589"
},
{
"name": "CVE-2018-15361",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15361"
},
{
"name": "CVE-2019-8262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8262"
},
{
"name": "CVE-2019-8277",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8277"
},
{
"name": "CVE-2019-8265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8265"
},
{
"name": "CVE-2019-8269",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8269"
},
{
"name": "CVE-2019-8260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8260"
},
{
"name": "CVE-2019-8263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8263"
},
{
"name": "CVE-2019-8261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8261"
},
{
"name": "CVE-2019-8276",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8276"
},
{
"name": "CVE-2019-8259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8259"
},
{
"name": "CVE-2019-8271",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8271"
},
{
"name": "CVE-2020-7586",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7586"
},
{
"name": "CVE-2019-8267",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8267"
},
{
"name": "CVE-2020-7580",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7580"
},
{
"name": "CVE-2019-8280",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8280"
},
{
"name": "CVE-2019-8275",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8275"
},
{
"name": "CVE-2019-8274",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8274"
},
{
"name": "CVE-2019-8266",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8266"
},
{
"name": "CVE-2019-8270",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8270"
},
{
"name": "CVE-2019-8258",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8258"
},
{
"name": "CVE-2019-8264",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8264"
},
{
"name": "CVE-2020-7585",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7585"
},
{
"name": "CVE-2019-8272",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8272"
},
{
"name": "CVE-2019-8268",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8268"
},
{
"name": "CVE-2019-8273",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8273"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-349",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-06-09T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-817401 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-817401.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-312271 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-689942 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-927095 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
}
]
}
CERTFR-2020-AVI-349
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC PDM | ||
| Siemens | N/A | SIMATIC WinCC OA V3.17 versions antérieures à V3.17-P003 | ||
| Siemens | N/A | SINUMERIK PCU base Win7 software /IPC versions antérieures à V12.01 HF4 | ||
| Siemens | N/A | SIMATIC NET PC versions antérieures à V16 Upd3 | ||
| Siemens | N/A | SIMATIC WinCC OA V3.16 versions antérieures à V3.16-P018 | ||
| Siemens | N/A | SINEC NMS sans le dernier correctif de sécurité | ||
| Siemens | N/A | SIMATIC PCS 7 | ||
| Siemens | N/A | LOGO!8 BM | ||
| Siemens | N/A | SIMATIC S7-1500 | ||
| Siemens | N/A | SINUMERIK Operate | ||
| Siemens | N/A | SINEMA Server sans le dernier correctif de sécurité | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced | ||
| Siemens | N/A | SIMATIC Automation Tool | ||
| Siemens | N/A | SINUMERIK ONE virtual | ||
| Siemens | N/A | SIMATIC ProSave | ||
| Siemens | N/A | SIMATIC WinCC V7.5 versions antérieures à V7.5 SP1 Update 3 | ||
| Siemens | N/A | SINAMICS STARTER commissioning tool | ||
| Siemens | N/A | SIMATIC WinCC Runtime Professional V13, V14, V15 et V16 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) V13, V14, V15 et V16 | ||
| Siemens | N/A | SIMATIC PCS neo | ||
| Siemens | N/A | SINAMICS Startdrive | ||
| Siemens | N/A | SINAMICS STARTER versions antérieures à V5.4 HF1 | ||
| Siemens | N/A | SIMATIC WinCC V7.4 versions antérieures à V7.4 SP1 Update 14 | ||
| Siemens | N/A | SIMATIC STEP 7 versions antérieures à V5.6 SP2 HF3 | ||
| Siemens | N/A | SINUMERIK Access MyMachine /P2P versions antérieures à V4.8 | ||
| Siemens | N/A | SINUMERIK PCU base Win10 software /IPC versions antérieures à V14.00 |
| Title | Publication Time | Tags | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC PDM",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA V3.17 versions ant\u00e9rieures \u00e0 V3.17-P003",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK PCU base Win7 software /IPC versions ant\u00e9rieures \u00e0 V12.01 HF4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC versions ant\u00e9rieures \u00e0 V16 Upd3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA V3.16 versions ant\u00e9rieures \u00e0 V3.16-P018",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC NMS sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO!8 BM",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Operate",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Server sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Automation Tool",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK ONE virtual",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ProSave",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.5 versions ant\u00e9rieures \u00e0 V7.5 SP1 Update 3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS STARTER commissioning tool",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Professional V13, V14, V15 et V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) V13, V14, V15 et V16",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS Startdrive",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS STARTER versions ant\u00e9rieures \u00e0 V5.4 HF1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.4 versions ant\u00e9rieures \u00e0 V7.4 SP1 Update 14",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 versions ant\u00e9rieures \u00e0 V5.6 SP2 HF3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Access MyMachine /P2P versions ant\u00e9rieures \u00e0 V4.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK PCU base Win10 software /IPC versions ant\u00e9rieures \u00e0 V14.00",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7589",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7589"
},
{
"name": "CVE-2018-15361",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15361"
},
{
"name": "CVE-2019-8262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8262"
},
{
"name": "CVE-2019-8277",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8277"
},
{
"name": "CVE-2019-8265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8265"
},
{
"name": "CVE-2019-8269",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8269"
},
{
"name": "CVE-2019-8260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8260"
},
{
"name": "CVE-2019-8263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8263"
},
{
"name": "CVE-2019-8261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8261"
},
{
"name": "CVE-2019-8276",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8276"
},
{
"name": "CVE-2019-8259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8259"
},
{
"name": "CVE-2019-8271",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8271"
},
{
"name": "CVE-2020-7586",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7586"
},
{
"name": "CVE-2019-8267",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8267"
},
{
"name": "CVE-2020-7580",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7580"
},
{
"name": "CVE-2019-8280",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8280"
},
{
"name": "CVE-2019-8275",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8275"
},
{
"name": "CVE-2019-8274",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8274"
},
{
"name": "CVE-2019-8266",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8266"
},
{
"name": "CVE-2019-8270",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8270"
},
{
"name": "CVE-2019-8258",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8258"
},
{
"name": "CVE-2019-8264",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8264"
},
{
"name": "CVE-2020-7585",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7585"
},
{
"name": "CVE-2019-8272",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8272"
},
{
"name": "CVE-2019-8268",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8268"
},
{
"name": "CVE-2019-8273",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8273"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-349",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-06-09T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-817401 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-817401.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-312271 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-689942 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-689942.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-927095 du 09 juin 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
}
]
}
CERTFR-2019-AVI-384
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | EcoStruxure Machine Expert HVAC (anciennement SoMachine HVAC) versions antérieures à 1.1.0 | ||
| Schneider Electric | N/A | Wiser for KNX (anciennement homeLYnk) versions antérieures à 2.4.0 | ||
| Schneider Electric | N/A | Modicon Premium | ||
| Schneider Electric | N/A | TelevisGO versions produites avant le 15 juillet 2019 et utilisant une version de UltraVNC, 1.0.9.6.1 et antérieure, sans le correctif de sécurité TelevisGo_HotFix_20190715.exe | ||
| Schneider Electric | N/A | Magelis HMIGTO series | ||
| Schneider Electric | N/A | Magelis XBTGH series | ||
| Schneider Electric | N/A | Magelis HMIGTUX series | ||
| Schneider Electric | N/A | Magelis XBTGC series | ||
| Schneider Electric | N/A | Modicon M580 versions antérieures à V2.90 | ||
| Schneider Electric | N/A | Magelis HMIGTU series | ||
| Schneider Electric | N/A | BMXNOR0200H Ethernet / Serial RTU module | ||
| Schneider Electric | N/A | Magelis HMISTO series | ||
| Schneider Electric | N/A | Magelis HMISCU series | ||
| Schneider Electric | N/A | Magelis HMIGXO series | ||
| Schneider Electric | Modicon M340 | Modicon M340 versions antérieures à V3.10 | ||
| Schneider Electric | N/A | Schneider Electric Software Update (SESU) SUT Service component versions antérieures à 2.3.1 | ||
| Schneider Electric | N/A | Magelis XBTGT series | ||
| Schneider Electric | N/A | Magelis HMIGXU series | ||
| Schneider Electric | N/A | Magelis HMISTU series | ||
| Schneider Electric | N/A | spaceLYnk versions antérieures à 2.4.0 | ||
| Schneider Electric | N/A | Modicon Quantum |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Machine Expert HVAC (anciennement SoMachine HVAC) versions ant\u00e9rieures \u00e0 1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Wiser for KNX (anciennement homeLYnk) versions ant\u00e9rieures \u00e0 2.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Premium",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "TelevisGO versions produites avant le 15 juillet 2019 et utilisant une version de UltraVNC, 1.0.9.6.1 et ant\u00e9rieure, sans le correctif de s\u00e9curit\u00e9 TelevisGo_HotFix_20190715.exe",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGH series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTUX series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGC series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 versions ant\u00e9rieures \u00e0 V2.90",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOR0200H Ethernet / Serial RTU module",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISTO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISCU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGXO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 versions ant\u00e9rieures \u00e0 V3.10",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Software Update (SESU) SUT Service component versions ant\u00e9rieures \u00e0 2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGT series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGXU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISTU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "spaceLYnk versions ant\u00e9rieures \u00e0 2.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-15361",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15361"
},
{
"name": "CVE-2019-8262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8262"
},
{
"name": "CVE-2019-8277",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8277"
},
{
"name": "CVE-2019-6828",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6828"
},
{
"name": "CVE-2019-8265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8265"
},
{
"name": "CVE-2019-8269",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8269"
},
{
"name": "CVE-2019-8260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8260"
},
{
"name": "CVE-2019-8263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8263"
},
{
"name": "CVE-2019-6832",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6832"
},
{
"name": "CVE-2019-8261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8261"
},
{
"name": "CVE-2019-8276",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8276"
},
{
"name": "CVE-2018-7846",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7846"
},
{
"name": "CVE-2019-8259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8259"
},
{
"name": "CVE-2018-7842",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7842"
},
{
"name": "CVE-2018-7849",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7849"
},
{
"name": "CVE-2019-8271",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8271"
},
{
"name": "CVE-2019-6831",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6831"
},
{
"name": "CVE-2019-6813",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6813"
},
{
"name": "CVE-2019-6809",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6809"
},
{
"name": "CVE-2019-6829",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6829"
},
{
"name": "CVE-2018-7852",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7852"
},
{
"name": "CVE-2019-8267",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8267"
},
{
"name": "CVE-2019-6830",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6830"
},
{
"name": "CVE-2019-6810",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6810"
},
{
"name": "CVE-2018-7854",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7854"
},
{
"name": "CVE-2019-8280",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8280"
},
{
"name": "CVE-2018-7844",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7844"
},
{
"name": "CVE-2018-7847",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7847"
},
{
"name": "CVE-2018-7855",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7855"
},
{
"name": "CVE-2019-8275",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8275"
},
{
"name": "CVE-2019-8274",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8274"
},
{
"name": "CVE-2019-6808",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6808"
},
{
"name": "CVE-2019-6826",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6826"
},
{
"name": "CVE-2018-7850",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7850"
},
{
"name": "CVE-2018-7856",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7856"
},
{
"name": "CVE-2019-8266",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8266"
},
{
"name": "CVE-2019-8270",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8270"
},
{
"name": "CVE-2019-6834",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6834"
},
{
"name": "CVE-2019-68067",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-68067"
},
{
"name": "CVE-2018-7845",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7845"
},
{
"name": "CVE-2019-8258",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8258"
},
{
"name": "CVE-2018-7857",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7857"
},
{
"name": "CVE-2019-8264",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8264"
},
{
"name": "CVE-2019-6833",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6833"
},
{
"name": "CVE-2019-8272",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8272"
},
{
"name": "CVE-2019-8268",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8268"
},
{
"name": "CVE-2019-68077",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-68077"
},
{
"name": "CVE-2019-8273",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8273"
},
{
"name": "CVE-2018-7853",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7853"
},
{
"name": "CVE-2018-7843",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7843"
},
{
"name": "CVE-2018-7848",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7848"
}
],
"links": [],
"reference": "CERTFR-2019-AVI-384",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-08-13T00:00:00.000000"
},
{
"description": "Ajout du bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-04 du 13 ao\u00fbt 2019",
"revision_date": "2019-08-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-06 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-06-SESU_SUT_Service.pdf\u0026p_Doc_Ref=SEVD-2019-225-06"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-04 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-04_SoMachine_HVAC_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-01 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-01-Magelis_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-03 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-03-Modicon-Ethernet+-Serial-RTU-Module-Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-07 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-07-spaceLYnk-homeLYnk.pdf\u0026p_Doc_Ref=SEVD-2019-225-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-02 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-02-Modicon_M340_Controllers_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-134-11 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-134-11-V2-Modicon-Controllers.pdf\u0026p_Doc_Ref=SEVD-2019-134-11"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-05 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-05-TelevisGO_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-05"
}
]
}
CERTFR-2019-AVI-384
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | EcoStruxure Machine Expert HVAC (anciennement SoMachine HVAC) versions antérieures à 1.1.0 | ||
| Schneider Electric | N/A | Wiser for KNX (anciennement homeLYnk) versions antérieures à 2.4.0 | ||
| Schneider Electric | N/A | Modicon Premium | ||
| Schneider Electric | N/A | TelevisGO versions produites avant le 15 juillet 2019 et utilisant une version de UltraVNC, 1.0.9.6.1 et antérieure, sans le correctif de sécurité TelevisGo_HotFix_20190715.exe | ||
| Schneider Electric | N/A | Magelis HMIGTO series | ||
| Schneider Electric | N/A | Magelis XBTGH series | ||
| Schneider Electric | N/A | Magelis HMIGTUX series | ||
| Schneider Electric | N/A | Magelis XBTGC series | ||
| Schneider Electric | N/A | Modicon M580 versions antérieures à V2.90 | ||
| Schneider Electric | N/A | Magelis HMIGTU series | ||
| Schneider Electric | N/A | BMXNOR0200H Ethernet / Serial RTU module | ||
| Schneider Electric | N/A | Magelis HMISTO series | ||
| Schneider Electric | N/A | Magelis HMISCU series | ||
| Schneider Electric | N/A | Magelis HMIGXO series | ||
| Schneider Electric | Modicon M340 | Modicon M340 versions antérieures à V3.10 | ||
| Schneider Electric | N/A | Schneider Electric Software Update (SESU) SUT Service component versions antérieures à 2.3.1 | ||
| Schneider Electric | N/A | Magelis XBTGT series | ||
| Schneider Electric | N/A | Magelis HMIGXU series | ||
| Schneider Electric | N/A | Magelis HMISTU series | ||
| Schneider Electric | N/A | spaceLYnk versions antérieures à 2.4.0 | ||
| Schneider Electric | N/A | Modicon Quantum |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Machine Expert HVAC (anciennement SoMachine HVAC) versions ant\u00e9rieures \u00e0 1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Wiser for KNX (anciennement homeLYnk) versions ant\u00e9rieures \u00e0 2.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Premium",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "TelevisGO versions produites avant le 15 juillet 2019 et utilisant une version de UltraVNC, 1.0.9.6.1 et ant\u00e9rieure, sans le correctif de s\u00e9curit\u00e9 TelevisGo_HotFix_20190715.exe",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGH series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTUX series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGC series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 versions ant\u00e9rieures \u00e0 V2.90",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOR0200H Ethernet / Serial RTU module",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISTO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISCU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGXO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 versions ant\u00e9rieures \u00e0 V3.10",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Software Update (SESU) SUT Service component versions ant\u00e9rieures \u00e0 2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGT series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGXU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISTU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "spaceLYnk versions ant\u00e9rieures \u00e0 2.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-15361",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15361"
},
{
"name": "CVE-2019-8262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8262"
},
{
"name": "CVE-2019-8277",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8277"
},
{
"name": "CVE-2019-6828",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6828"
},
{
"name": "CVE-2019-8265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8265"
},
{
"name": "CVE-2019-8269",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8269"
},
{
"name": "CVE-2019-8260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8260"
},
{
"name": "CVE-2019-8263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8263"
},
{
"name": "CVE-2019-6832",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6832"
},
{
"name": "CVE-2019-8261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8261"
},
{
"name": "CVE-2019-8276",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8276"
},
{
"name": "CVE-2018-7846",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7846"
},
{
"name": "CVE-2019-8259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8259"
},
{
"name": "CVE-2018-7842",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7842"
},
{
"name": "CVE-2018-7849",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7849"
},
{
"name": "CVE-2019-8271",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8271"
},
{
"name": "CVE-2019-6831",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6831"
},
{
"name": "CVE-2019-6813",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6813"
},
{
"name": "CVE-2019-6809",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6809"
},
{
"name": "CVE-2019-6829",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6829"
},
{
"name": "CVE-2018-7852",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7852"
},
{
"name": "CVE-2019-8267",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8267"
},
{
"name": "CVE-2019-6830",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6830"
},
{
"name": "CVE-2019-6810",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6810"
},
{
"name": "CVE-2018-7854",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7854"
},
{
"name": "CVE-2019-8280",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8280"
},
{
"name": "CVE-2018-7844",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7844"
},
{
"name": "CVE-2018-7847",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7847"
},
{
"name": "CVE-2018-7855",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7855"
},
{
"name": "CVE-2019-8275",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8275"
},
{
"name": "CVE-2019-8274",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8274"
},
{
"name": "CVE-2019-6808",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6808"
},
{
"name": "CVE-2019-6826",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6826"
},
{
"name": "CVE-2018-7850",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7850"
},
{
"name": "CVE-2018-7856",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7856"
},
{
"name": "CVE-2019-8266",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8266"
},
{
"name": "CVE-2019-8270",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8270"
},
{
"name": "CVE-2019-6834",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6834"
},
{
"name": "CVE-2019-68067",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-68067"
},
{
"name": "CVE-2018-7845",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7845"
},
{
"name": "CVE-2019-8258",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8258"
},
{
"name": "CVE-2018-7857",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7857"
},
{
"name": "CVE-2019-8264",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8264"
},
{
"name": "CVE-2019-6833",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6833"
},
{
"name": "CVE-2019-8272",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8272"
},
{
"name": "CVE-2019-8268",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8268"
},
{
"name": "CVE-2019-68077",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-68077"
},
{
"name": "CVE-2019-8273",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8273"
},
{
"name": "CVE-2018-7853",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7853"
},
{
"name": "CVE-2018-7843",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7843"
},
{
"name": "CVE-2018-7848",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7848"
}
],
"links": [],
"reference": "CERTFR-2019-AVI-384",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-08-13T00:00:00.000000"
},
{
"description": "Ajout du bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-04 du 13 ao\u00fbt 2019",
"revision_date": "2019-08-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-06 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-06-SESU_SUT_Service.pdf\u0026p_Doc_Ref=SEVD-2019-225-06"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-04 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-04_SoMachine_HVAC_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-01 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-01-Magelis_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-03 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-03-Modicon-Ethernet+-Serial-RTU-Module-Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-07 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-07-spaceLYnk-homeLYnk.pdf\u0026p_Doc_Ref=SEVD-2019-225-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-02 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-02-Modicon_M340_Controllers_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-134-11 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-134-11-V2-Modicon-Controllers.pdf\u0026p_Doc_Ref=SEVD-2019-134-11"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-05 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-05-TelevisGO_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-05"
}
]
}
GSD-2019-8276
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2019-8276",
"description": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"id": "GSD-2019-8276"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2019-8276"
],
"details": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"id": "GSD-2019-8276",
"modified": "2023-12-13T01:23:48.815110Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"DATE_PUBLIC": "2019-03-01T00:00:00",
"ID": "CVE-2019-8276",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UltraVNC",
"version": {
"version_data": [
{
"version_value": "1.2.2.3"
}
]
}
}
]
},
"vendor_name": "Kaspersky Lab"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.2.2.3",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:sinumerik_access_mymachine\\/p2p:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.8",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\/ipc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "14.00",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\/ipc:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "12.01",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "vulnerability@kaspersky.com",
"ID": "CVE-2019-8276"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/",
"refsource": "MISC",
"tags": [
"Third Party Advisory"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2020-10-22T16:58Z",
"publishedDate": "2019-03-08T23:29Z"
}
}
}
ICSA-20-161-06
Vulnerability from csaf_cisa - Published: 2020-06-09 00:00 - Updated: 2020-06-09 00:00Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reporting these vulnerabilities to CISA"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow remote code execution, information disclosure, and denial-of-service attacks under certain conditions.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Energy, Food and Agriculture, Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Listed vulnerabilities are part of a Kaspersky report. See VNC\nvulnerability research for related security advisories and additional\ninformation on the vulnerabilites.\n\nFor further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "general",
"text": "Listed vulnerabilities are part of a Kaspersky report. See VNC vulnerability research for related security advisories and additional information on the vulnerabilites. For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-161-06 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-161-06.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-161-06 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-161-06"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.us-cert.gov/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "SSA-496604: SSA-927095: UltraVNC Vulnerabilities in SINUMERIK Products - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/SSA-927095.txt"
}
],
"title": "Siemens SINUMERIK",
"tracking": {
"current_release_date": "2020-06-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-161-06",
"initial_release_date": "2020-06-09T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-06-09T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-161-06 Siemens SINUMERIK"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V4.8",
"product": {
"name": "SINUMERIK Access MyMachine /P2P: All versions \u003c V4.8",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SINUMERIK Access MyMachine /P2P"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V14.00",
"product": {
"name": "SINUMERIK PCU base Win10 software /IPC: All versions \u003c V14.00",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU base Win10 software /IPC"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V12.01 HF4",
"product": {
"name": "SINUMERIK PCU base Win7 software /IPC: All versions \u003c V12.01 HF4",
"product_id": "CSAFPID-0003"
}
}
],
"category": "product_name",
"name": "SINUMERIK PCU base Win7 software /IPC"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-15361",
"cwe": {
"id": "CWE-124",
"name": "Buffer Underwrite (\u0027Buffer Underflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 has a buffer underflow vulnerability in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-15361"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8258",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 has a heap buffer overflow vulnerability in VNC client code which results code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8258"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8259",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1198 contains multiple memory leaks in VNC client code, which allow an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1199.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8259"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8260",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC client RRE decoder code, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8260"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8261",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1199 has a out-of-bounds read vulnerability in VNC code inside client CoRRE decoder, caused by multiplication overflow. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1200.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8261"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8262",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has multiple heap buffer overflow vulnerabilities in VNC client code inside Ultra decoder, which results in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8262"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8263",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1205 has stack-based buffer overflow vulnerability in VNC client code inside ShowConnInfo routine, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. User interaction is required to trigger this vulnerability. This vulnerability has been fixed in revision 1206.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8263"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8264",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside Ultra2 decoder, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8264"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8265",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of SETPIXELS macro in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8265"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8266",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has multiple out-of-bounds access vulnerabilities connected with improper usage of ClientConnection::Copybuffer function in VNC client code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. User interaction is required to trigger these vulnerabilities. These vulnerabilities have been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8266"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8267",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1207 has out-of-bounds read vulnerability in VNC client code inside TextChat module, which results in a denial of service (DoS) condition. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1208.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8267"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8268",
"cwe": {
"id": "CWE-193",
"name": "Off-by-one Error"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1206 has multiple off-by-one vulnerabilities in VNC client code connected with improper usage of ClientConnection::ReadString function, which can potentially result code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1207.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8268"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8269",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1206 has stack-based Buffer overflow vulnerability in VNC client code inside FileTransfer module, which leads to a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1207.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8269"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8270",
"cwe": {
"id": "CWE-125",
"name": "Out-of-bounds Read"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1210 has out-of-bounds read vulnerability in VNC client code inside Ultra decoder, which results in a denial of service (DoS) condition. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1211.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8270"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8271",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer handler, which can potentially result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8271"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8272",
"cwe": {
"id": "CWE-193",
"name": "Off-by-one Error"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple off-by-one vulnerabilities in VNC server code, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8272"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8273",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer request handler, which can potentially result in code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8273"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8274",
"cwe": {
"id": "CWE-122",
"name": "Heap-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a heap buffer overflow vulnerability in VNC server code inside file transfer offer handler, which can potentially in result code execution. This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8274"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8275",
"cwe": {
"id": "CWE-170",
"name": "Improper Null Termination"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has multiple improper null termination vulnerabilities in VNC server code, which result in out-of-bound data being accessed by remote users. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8275"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8276",
"cwe": {
"id": "CWE-121",
"name": "Stack-based Buffer Overflow"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8276"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8277",
"cwe": {
"id": "CWE-665",
"name": "Improper Initialization"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1211 contains multiple memory leaks in VNC server code, which allows an attacker to read stack memory and can be abused for information disclosure. Combined with another vulnerability, it can be used to leak stack memory and bypass ASLR. This attack appears to be exploitable via network connectivity. These vulnerabilities have been fixed in revision 1212.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8277"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
},
{
"cve": "CVE-2019-8280",
"cwe": {
"id": "CWE-788",
"name": "Access of Memory Location After End of Buffer"
},
"notes": [
{
"category": "summary",
"text": "UltraVNC revision 1203 has out-of-bounds access vulnerability in VNC client inside RAW decoder, which can potentially result code execution. This attack appear to be exploitable via network connectivity. This vulnerability has been fixed in revision 1204.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
"references": [
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-8280"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the device to the internal or VPN network and to\ntrusted IP addresses only.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002",
"CSAFPID-0003"
]
}
]
}
]
}
FKIE_CVE-2019-8276
Vulnerability from fkie_nvd - Published: 2019-03-08 23:29 - Updated: 2024-11-21 04:49| URL | Tags | ||
|---|---|---|---|
| vulnerability@kaspersky.com | https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | Third Party Advisory | |
| vulnerability@kaspersky.com | https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/ | Third Party Advisory | |
| vulnerability@kaspersky.com | https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.us-cert.gov/ics/advisories/icsa-20-161-06 | Third Party Advisory, US Government Resource |
| Vendor | Product | Version | |
|---|---|---|---|
| uvnc | ultravnc | * | |
| siemens | sinumerik_access_mymachine\/p2p | * | |
| siemens | sinumerik_pcu_base_win10_software\/ipc | * | |
| siemens | sinumerik_pcu_base_win7_software\/ipc | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:uvnc:ultravnc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "555D034F-3D64-4ED1-9B63-F8D59199E99C",
"versionEndExcluding": "1.2.2.3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinumerik_access_mymachine\\/p2p:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D9345335-DF62-4472-93CD-E2C85453F91E",
"versionEndExcluding": "4.8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_pcu_base_win10_software\\/ipc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7498412D-79FD-43FE-AD9B-5820FB5CF7D8",
"versionEndExcluding": "14.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:sinumerik_pcu_base_win7_software\\/ipc:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1F603341-03C5-46CA-8A74-EC5A50135194",
"versionEndIncluding": "12.01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212."
},
{
"lang": "es",
"value": "UltraVNC, en su revisi\u00f3n 1211, tiene una vulnerabilidad de desbordamiento de b\u00fafer basado en pila en el c\u00f3digo del servidor VNC dentro del manipulador de peticiones de trasferencia de datos, lo que puede resultar en una denegaci\u00f3n de servicio (DoS). Este ataque parece ser explotable mediante la conectividad de red. Esta vulnerabilidad se ha solucionado en la revisi\u00f3n 1212."
}
],
"id": "CVE-2019-8276",
"lastModified": "2024-11-21T04:49:37.950",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-03-08T23:29:00.937",
"references": [
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"source": "vulnerability@kaspersky.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"sourceIdentifier": "vulnerability@kaspersky.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "vulnerability@kaspersky.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GHSA-7XXM-JWGJ-V243
Vulnerability from github – Published: 2022-05-13 01:14 – Updated: 2022-05-13 01:14UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.
{
"affected": [],
"aliases": [
"CVE-2019-8276"
],
"database_specific": {
"cwe_ids": [
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2019-03-08T23:29:00Z",
"severity": "HIGH"
},
"details": "UltraVNC revision 1211 has a stack buffer overflow vulnerability in VNC server code inside file transfer request handler, which can result in Denial of Service (DoS). This attack appears to be exploitable via network connectivity. This vulnerability has been fixed in revision 1212.",
"id": "GHSA-7xxm-jwgj-v243",
"modified": "2022-05-13T01:14:20Z",
"published": "2022-05-13T01:14:20Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-8276"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-927095.pdf"
},
{
"type": "WEB",
"url": "https://ics-cert.kaspersky.com/advisories/klcert-advisories/2019/03/01/klcert-19-023-ultravnc-stack-based-buffer-overflow"
},
{
"type": "WEB",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-06"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
CNVD-2019-13283
Vulnerability from cnvd - Published: 2019-05-08厂商已发布漏洞修复程序,请及时关注更新: https://www.uvnc.com/
| Name | UltraVNC UltraVNC 1211 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2019-8276"
}
},
"description": "UltraVNC\u662f\u4e00\u6b3e\u7528\u4e8eWindows\u5e73\u53f0\u7684\u5f00\u6e90\u8fdc\u7a0b\u7ec8\u7aef\u63a7\u5236\u8f6f\u4ef6\u3002\n\nUltraVNC 1211\u7248\u672c\u4e2d\u7684\u6587\u4ef6\u4f20\u8f93\u8bf7\u6c42\u5904\u7406\u7a0b\u5e8f\u7684VNC\u670d\u52a1\u5668\u4ee3\u7801\u5b58\u5728\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u9020\u6210\u62d2\u7edd\u670d\u52a1\u3002",
"discovererName": "unKnow",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.uvnc.com/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2019-13283",
"openTime": "2019-05-08",
"patchDescription": "UltraVNC\u662f\u4e00\u6b3e\u7528\u4e8eWindows\u5e73\u53f0\u7684\u5f00\u6e90\u8fdc\u7a0b\u7ec8\u7aef\u63a7\u5236\u8f6f\u4ef6\u3002\r\n\r\nUltraVNC 1211\u7248\u672c\u4e2d\u7684\u6587\u4ef6\u4f20\u8f93\u8bf7\u6c42\u5904\u7406\u7a0b\u5e8f\u7684VNC\u670d\u52a1\u5668\u4ee3\u7801\u5b58\u5728\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u9020\u6210\u62d2\u7edd\u670d\u52a1\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "UltraVNC\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "UltraVNC UltraVNC 1211"
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2019-8276",
"serverity": "\u4e2d",
"submitTime": "2019-03-11",
"title": "UltraVNC\u6808\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.