CVE-2020-12834 (GCVE-0-2020-12834)

Vulnerability from cvelistv5 – Published: 2020-05-15 16:14 – Updated: 2024-08-04 12:04
VLAI?
Summary
eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset).
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:04:22.903Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://psytester.github.io/CVE-2020-12834/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-15T16:14:49",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://psytester.github.io/CVE-2020-12834/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-12834",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psytester.github.io/CVE-2020-12834/",
              "refsource": "MISC",
              "url": "https://psytester.github.io/CVE-2020-12834/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-12834",
    "datePublished": "2020-05-15T16:14:49",
    "dateReserved": "2020-05-13T00:00:00",
    "dateUpdated": "2024-08-04T12:04:22.903Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.51.6\", \"matchCriteriaId\": \"01848E5D-7A8C-4DAD-967D-E29FB129C2EF\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:eq-3:homematic_ccu2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9C2CF19C-7EDE-4E3C-A736-E6736FF03FDC\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:ccu3_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"3.51.6\", \"matchCriteriaId\": \"62962D0F-9A5C-4A4A-81CE-1D0A0B54434F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:eq-3:homematic_ccu3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"33113AD0-F378-49B2-BCFC-C57B52FD3A04\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset).\"}, {\"lang\": \"es\", \"value\": \"eQ-3 Homematic Central Control Unit (CCU)2 versiones hasta 2.51.6 y la CCU3 versiones hasta 3.51.6, permiten una ejecuci\\u00f3n de c\\u00f3digo remota en el JSON API Method ReGa.runScript, por parte de atacantes no autenticados con acceso a la interfaz web, debido a que la funcionalidad auto-login predeterminada est\\u00e1 activada durante la configuraci\\u00f3n por primera vez (o el restablecimiento de f\\u00e1brica).\"}]",
      "id": "CVE-2020-12834",
      "lastModified": "2024-11-21T05:00:22.087",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2020-05-15T17:15:12.500",
      "references": "[{\"url\": \"https://psytester.github.io/CVE-2020-12834/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://psytester.github.io/CVE-2020-12834/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-276\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-12834\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-05-15T17:15:12.500\",\"lastModified\":\"2024-11-21T05:00:22.087\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset).\"},{\"lang\":\"es\",\"value\":\"eQ-3 Homematic Central Control Unit (CCU)2 versiones hasta 2.51.6 y la CCU3 versiones hasta 3.51.6, permiten una ejecuci\u00f3n de c\u00f3digo remota en el JSON API Method ReGa.runScript, por parte de atacantes no autenticados con acceso a la interfaz web, debido a que la funcionalidad auto-login predeterminada est\u00e1 activada durante la configuraci\u00f3n por primera vez (o el restablecimiento de f\u00e1brica).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.51.6\",\"matchCriteriaId\":\"01848E5D-7A8C-4DAD-967D-E29FB129C2EF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:eq-3:homematic_ccu2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C2CF19C-7EDE-4E3C-A736-E6736FF03FDC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:ccu3_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.51.6\",\"matchCriteriaId\":\"62962D0F-9A5C-4A4A-81CE-1D0A0B54434F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:eq-3:homematic_ccu3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33113AD0-F378-49B2-BCFC-C57B52FD3A04\"}]}]}],\"references\":[{\"url\":\"https://psytester.github.io/CVE-2020-12834/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://psytester.github.io/CVE-2020-12834/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…