CVE-2020-25082 (GCVE-0-2020-25082)
Vulnerability from cvelistv5 – Published: 2021-08-10 15:28 – Updated: 2024-08-04 15:26
VLAI
EPSS
VEX
Summary
An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy.
Severity
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.nuvoton.com/support/product-related-i… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.290Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:P/A:N/C:H/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-10T15:28:05.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25082",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:P/A:N/C:H/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/",
"refsource": "MISC",
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25082",
"datePublished": "2021-08-10T15:28:05.000Z",
"dateReserved": "2020-09-02T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:26:09.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-25082",
"date": "2026-09-17",
"epss": "0.00207",
"percentile": "0.11039"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nuvoton:npct75x_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3EC7A422-C144-418F-9642-B5FEFC1D16E1",
"versionEndExcluding": "7.2.2.0",
"versionStartIncluding": "7.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nuvoton:npct75x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17DAAE4D-AC8A-44CC-A6A9-66E773DCB11F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy."
},
{
"lang": "es",
"value": "Un atacante con acceso f\u00edsico a Nuvoton Trusted Platform Module (NPCT75x versiones 7.2.x anteriores a 7.2.2.0) podr\u00eda extraer una clave privada de Elliptic Curve Cryptography (ECC) por medio de un ataque de canal lateral contra ECDSA, debido a una Discrepancia de Tiempo Observable"
}
],
"id": "CVE-2020-25082",
"lastModified": "2024-11-21T05:17:13.177",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.4,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.2,
"impactScore": 3.6,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-10T17:15:07.087",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-203"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:nuvoton:npct75x_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3EC7A422-C144-418F-9642-B5FEFC1D16E1",
"versionEndExcluding": "7.2.2.0",
"versionStartIncluding": "7.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:nuvoton:npct75x:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17DAAE4D-AC8A-44CC-A6A9-66E773DCB11F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy."
},
{
"lang": "es",
"value": "Un atacante con acceso f\u00edsico a Nuvoton Trusted Platform Module (NPCT75x versiones 7.2.x anteriores a 7.2.2.0) podr\u00eda extraer una clave privada de Elliptic Curve Cryptography (ECC) por medio de un ataque de canal lateral contra ECDSA, debido a una Discrepancia de Tiempo Observable"
}
],
"id": "CVE-2020-25082",
"lastModified": "2024-11-21T05:17:13.177",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 1.9,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:M/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.4,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.2,
"impactScore": 3.6,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-10T17:15:07.087",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-203"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…