CVE-2020-25082 (GCVE-0-2020-25082)
Vulnerability from cvelistv5 – Published: 2021-08-10 15:28 – Updated: 2024-08-04 15:26
VLAI
Summary
An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy.
Severity
CWE
- n/a
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.nuvoton.com/support/product-related-i… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.290Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:P/A:N/C:H/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-10T15:28:05.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-25082",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:H/AV:P/A:N/C:H/I:N/PR:H/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/",
"refsource": "MISC",
"url": "https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-25082",
"datePublished": "2021-08-10T15:28:05.000Z",
"dateReserved": "2020-09-02T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:26:09.290Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-25082",
"date": "2026-06-03",
"epss": "0.00059",
"percentile": "0.18679"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:nuvoton:npct75x_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.2.0\", \"versionEndExcluding\": \"7.2.2.0\", \"matchCriteriaId\": \"3EC7A422-C144-418F-9642-B5FEFC1D16E1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:nuvoton:npct75x:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17DAAE4D-AC8A-44CC-A6A9-66E773DCB11F\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy.\"}, {\"lang\": \"es\", \"value\": \"Un atacante con acceso f\\u00edsico a Nuvoton Trusted Platform Module (NPCT75x versiones 7.2.x anteriores a 7.2.2.0) podr\\u00eda extraer una clave privada de Elliptic Curve Cryptography (ECC) por medio de un ataque de canal lateral contra ECDSA, debido a una Discrepancia de Tiempo Observable\"}]",
"id": "CVE-2020-25082",
"lastModified": "2024-11-21T05:17:13.177",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 3.8, \"baseSeverity\": \"LOW\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 0.2, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 3.8, \"baseSeverity\": \"LOW\", \"attackVector\": \"PHYSICAL\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 0.2, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:M/Au:N/C:P/I:N/A:N\", \"baseScore\": 1.9, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.4, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-08-10T17:15:07.087",
"references": "[{\"url\": \"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-203\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-25082\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-08-10T17:15:07.087\",\"lastModified\":\"2024-11-21T05:17:13.177\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An attacker with physical access to Nuvoton Trusted Platform Module (NPCT75x 7.2.x before 7.2.2.0) could extract an Elliptic Curve Cryptography (ECC) private key via a side-channel attack against ECDSA, because of an Observable Timing Discrepancy.\"},{\"lang\":\"es\",\"value\":\"Un atacante con acceso f\u00edsico a Nuvoton Trusted Platform Module (NPCT75x versiones 7.2.x anteriores a 7.2.2.0) podr\u00eda extraer una clave privada de Elliptic Curve Cryptography (ECC) por medio de un ataque de canal lateral contra ECDSA, debido a una Discrepancia de Tiempo Observable\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":3.8,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.2,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:H/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":3.8,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":1.9,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.4,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-203\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:nuvoton:npct75x_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.2.0\",\"versionEndExcluding\":\"7.2.2.0\",\"matchCriteriaId\":\"3EC7A422-C144-418F-9642-B5FEFC1D16E1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:nuvoton:npct75x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17DAAE4D-AC8A-44CC-A6A9-66E773DCB11F\"}]}]}],\"references\":[{\"url\":\"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.nuvoton.com/support/product-related-information/security-advisories/sa-002/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…