CVE-2020-26997
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:03
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:03:23.217Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Solid Edge SE2020",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c SE2020MP13"
            }
          ]
        },
        {
          "product": "Solid Edge SE2020",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c SE2020MP14"
            }
          ]
        },
        {
          "product": "Solid Edge SE2021",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c SE2021MP4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822: Untrusted Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-08T19:47:15",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-26997",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Solid Edge SE2020",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c SE2020MP13"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Solid Edge SE2020",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c SE2020MP14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Solid Edge SE2021",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All Versions \u003c SE2021MP4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-822: Untrusted Pointer Dereference"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-26997",
    "datePublished": "2021-04-22T20:42:19",
    "dateReserved": "2020-10-12T00:00:00",
    "dateUpdated": "2024-08-04T16:03:23.217Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-26997\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-04-22T21:15:09.187\",\"lastModified\":\"2021-06-08T20:15:08.050\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2020 (All versions \u003c SE2020MP14), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11919)\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP14), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP4). Las aplicaciones afectadas carecen de la validaci\u00f3n adecuada de los datos suministrados por el usuario al analizar los archivos PAR. Esto podr\u00eda dar lugar a desviaciones de puntero de un valor obtenido de una fuente no fiable. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual. (ZDI-CAN-11919)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-822\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2020:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"se2020mp13\",\"matchCriteriaId\":\"FF72CFDF-0F35-434F-9BBC-181B6CD98086\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge_se2021:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"se2021mp14\",\"matchCriteriaId\":\"48EE7B47-BED5-4D33-8D1F-913267DDBA12\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.