CVE-2020-27009
Vulnerability from cvelistv5
Published
2021-04-22 20:42
Modified
2024-08-04 16:03
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions < V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:23.236Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "APOGEE PXC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.5" } ] }, { "defaultStatus": "unknown", "product": "APOGEE PXC Compact (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.20" } ] }, { "defaultStatus": "unknown", "product": "APOGEE PXC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.5" } ] }, { "defaultStatus": "unknown", "product": "APOGEE PXC Modular (P2 Ethernet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.8.20" } ] }, { "defaultStatus": "unknown", "product": "Nucleus NET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2" } ] }, { "defaultStatus": "unknown", "product": "Nucleus Source Code", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "Versions including affected DNS modules" } ] }, { "defaultStatus": "unknown", "product": "TALON TC Compact (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.5" } ] }, { "defaultStatus": "unknown", "product": "TALON TC Modular (BACnet)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.5.5" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-823", "description": "CWE-823: Use of Out-of-range Pointer Offset", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-08-08T09:20:02.298Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-27009", "datePublished": "2021-04-22T20:42:19", "dateReserved": "2020-10-12T00:00:00", "dateUpdated": "2024-08-04T16:03:23.236Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-27009\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-04-22T21:15:09.220\",\"lastModified\":\"2023-08-08T10:15:11.637\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.20), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.20), Nucleus NET (All versions \u003c V5.2), Nucleus Source Code (Versions including affected DNS modules), TALON TC Compact (BACnet) (All versions \u003c V3.5.5), TALON TC Modular (BACnet) (All versions \u003c V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a write past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to execute code in the context of the current process or cause a denial-of-service condition.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones anteriores a V5.2), Nucleus Source Code (Versiones que incluyen los m\u00f3dulos DNS afectados). La funcionalidad de descompresi\u00f3n de registros de nombres de dominio DNS no valida correctamente los valores de desplazamiento del puntero. El an\u00e1lisis sint\u00e1ctico de respuestas malformadas podr\u00eda dar lugar a una escritura m\u00e1s all\u00e1 del final de una estructura asignada. Un atacante con una posici\u00f3n privilegiada en la red podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual o provocar una condici\u00f3n de denegaci\u00f3n de servicio\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-823\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2\",\"matchCriteriaId\":\"7AA3D291-7974-459E-8629-82EEE9222881\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:nucleus_source_code:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53A38C64-612A-4BC5-83D5-D3FA1C90E0F7\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.