CVE-2020-27484 (GCVE-0-2020-27484)
Vulnerability from cvelistv5 – Published: 2020-11-16 20:59 – Updated: 2024-08-04 16:18
VLAI?
Summary
Garmin Forerunner 235 before 8.20 is affected by: Integer Overflow. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check for overflow when allocating the array for the NEWA instruction. This a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:18:44.312Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Garmin Forerunner 235 before 8.20 is affected by: Integer Overflow. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check for overflow when allocating the array for the NEWA instruction. This a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-16T20:59:25.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-27484",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Garmin Forerunner 235 before 8.20 is affected by: Integer Overflow. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check for overflow when allocating the array for the NEWA instruction. This a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md",
"refsource": "MISC",
"url": "https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-27484",
"datePublished": "2020-11-16T20:59:25.000Z",
"dateReserved": "2020-10-21T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:18:44.312Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2020-27484",
"date": "2026-05-06",
"epss": "0.00932",
"percentile": "0.76228"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:garmin:forerunner_235_firmware:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.90\", \"versionEndExcluding\": \"8.20\", \"matchCriteriaId\": \"6043DF86-0FC7-4F8D-A1F4-A8A79BF90099\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:garmin:forerunner_235:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3387D0DB-AB79-4860-B741-CE78FE79139D\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Garmin Forerunner 235 before 8.20 is affected by: Integer Overflow. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check for overflow when allocating the array for the NEWA instruction. This a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment.\"}, {\"lang\": \"es\", \"value\": \"Garmin Forerunner 235 versiones anteriores a 8.20, est\\u00e1 afectado por: un Desbordamiento de Enteros.\u0026#xa0;El componente es: ConnectIQ TVM.\u0026#xa0;El vector de ataque es: Para explotar la vulnerabilidad, el atacante debe cargar una aplicaci\\u00f3n de ConnectIQ maliciosa en la tienda ConnectIQ.\u0026#xa0;El int\\u00e9rprete del programa ConnectIQ presenta un fallo al comprobar el desbordamiento al asignar la matriz para la instrucci\\u00f3n NEWA.\u0026#xa0;Esta es una primitiva de lectura y escritura restringida en todo el espacio de direcciones MAX32630.\u0026#xa0;Una explotaci\\u00f3n con \\u00e9xito permitir\\u00eda a una aplicaci\\u00f3n de la tienda de aplicaciones ConnectIQ escapar y llevar a cabo actividades fuera del entorno de ejecuci\\u00f3n de aplicaciones restringido\"}]",
"id": "CVE-2020-27484",
"lastModified": "2024-11-21T05:21:15.507",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.9, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.1, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\", \"baseScore\": 6.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-11-16T21:15:13.377",
"references": "[{\"url\": \"https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-190\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-27484\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-11-16T21:15:13.377\",\"lastModified\":\"2024-11-21T05:21:15.507\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Garmin Forerunner 235 before 8.20 is affected by: Integer Overflow. The component is: ConnectIQ TVM. The attack vector is: To exploit the vulnerability, the attacker must upload a malicious ConnectIQ application to the ConnectIQ store. The ConnectIQ program interpreter fails to check for overflow when allocating the array for the NEWA instruction. This a constrained read/write primitive across the entire MAX32630 address space. A successful exploit would allow a ConnectIQ app store application to escape and perform activities outside the restricted application execution environment.\"},{\"lang\":\"es\",\"value\":\"Garmin Forerunner 235 versiones anteriores a 8.20, est\u00e1 afectado por: un Desbordamiento de Enteros.\u0026#xa0;El componente es: ConnectIQ TVM.\u0026#xa0;El vector de ataque es: Para explotar la vulnerabilidad, el atacante debe cargar una aplicaci\u00f3n de ConnectIQ maliciosa en la tienda ConnectIQ.\u0026#xa0;El int\u00e9rprete del programa ConnectIQ presenta un fallo al comprobar el desbordamiento al asignar la matriz para la instrucci\u00f3n NEWA.\u0026#xa0;Esta es una primitiva de lectura y escritura restringida en todo el espacio de direcciones MAX32630.\u0026#xa0;Una explotaci\u00f3n con \u00e9xito permitir\u00eda a una aplicaci\u00f3n de la tienda de aplicaciones ConnectIQ escapar y llevar a cabo actividades fuera del entorno de ejecuci\u00f3n de aplicaciones restringido\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.9,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.1,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-190\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:garmin:forerunner_235_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.90\",\"versionEndExcluding\":\"8.20\",\"matchCriteriaId\":\"6043DF86-0FC7-4F8D-A1F4-A8A79BF90099\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:garmin:forerunner_235:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3387D0DB-AB79-4860-B741-CE78FE79139D\"}]}]}],\"references\":[{\"url\":\"https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/atredispartners/advisories/blob/master/ATREDIS-2020-0004.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…