CVE-2020-8481
Vulnerability from cvelistv5
Published
2020-04-29 01:30
Modified
2024-08-04 10:03
Severity ?
EPSS score ?
Summary
ABB Central Licensing System - Information disclosure
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | ABB | Central Licensing System |
Version: 5.1 < 5* |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:03:45.868Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Central Licensing System", "vendor": "ABB", "versions": [ { "lessThan": "5*", "status": "affected", "version": "5.1", "versionType": "custom" } ] }, { "product": "ABB Ability System 800xA", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" } ] }, { "product": "Compact HMI", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" } ] }, { "product": "Control Builder Safe", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1.0" }, { "status": "affected", "version": "1.1" }, { "status": "affected", "version": "2.0" } ] }, { "product": "Symphony Plus S+ Operations", "vendor": "ABB", "versions": [ { "lessThanOrEqual": "3.2", "status": "affected", "version": "3", "versionType": "custom" } ] }, { "product": "Symphony Plus S+ Engineering ", "vendor": "ABB", "versions": [ { "lessThanOrEqual": "2.2", "status": "affected", "version": "1.1", "versionType": "custom" } ] }, { "product": "Composer Harmony", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" } ] }, { "product": "Composer Melody ", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.3" }, { "lessThanOrEqual": "6.3", "status": "affected", "version": "6", "versionType": "custom" } ] }, { "product": "Harmony OPC Server Standalone", "vendor": "ABB", "versions": [ { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" }, { "status": "affected", "version": "7.0" } ] }, { "product": "Advant OCS Control Builder A", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1.3" }, { "status": "affected", "version": "1.4" } ] }, { "product": "Composer CTK", "vendor": "ABB", "versions": [ { "status": "affected", "version": "6.1" }, { "status": "affected", "version": "6.2" } ] }, { "product": "AdvaBuild", "vendor": "ABB", "versions": [ { "status": "affected", "version": "3.7 SP1" }, { "status": "affected", "version": "3.7 SP2" } ] }, { "product": "OPC Server for Mod 300 (non-800xA)", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1.4" } ] }, { "product": "OPC Data Link", "vendor": "ABB", "versions": [ { "status": "affected", "version": "2.1" }, { "status": "affected", "version": "2.2" } ] }, { "product": "Knowledge Manager", "vendor": "ABB", "versions": [ { "status": "affected", "version": "8.0" }, { "status": "affected", "version": "9.0" }, { "status": "affected", "version": "9.1" } ] }, { "product": "Manufacturing Operations Management", "vendor": "ABB", "versions": [ { "status": "affected", "version": "1812" }, { "status": "affected", "version": "1909" } ] }, { "product": "Advant OCS AC 100 OPS Server", "vendor": "ABB", "versions": [ { "status": "affected", "version": "5.1" }, { "status": "affected", "version": "6.0" }, { "status": "affected", "version": "6.1" } ] } ], "descriptions": [ { "lang": "en", "value": "For ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200 Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-29T01:30:56", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "source": { "discovery": "UNKNOWN" }, "title": "ABB Central Licensing System - Information disclosure", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@ch.abb.com", "ID": "CVE-2020-8481", "STATE": "PUBLIC", "TITLE": "ABB Central Licensing System - Information disclosure" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Central Licensing System", "version": { "version_data": [ { "version_affected": "\u003e=", "version_name": "5", "version_value": "5.1" } ] } }, { "product_name": "ABB Ability System 800xA", "version": { "version_data": [ { "version_affected": "=", "version_value": "5.1" }, { "version_affected": "=", "version_value": "6.0" }, { "version_affected": "=", "version_value": "6.1" } ] } }, { "product_name": "Compact HMI", "version": { "version_data": [ { "version_affected": "=", "version_value": "5.1" }, { "version_affected": "=", "version_value": "6.0" } ] } }, { "product_name": "Control Builder Safe", "version": { "version_data": [ { "version_affected": "=", "version_value": "1.0" }, { "version_affected": "=", "version_value": "1.1" }, { "version_affected": "=", "version_value": "2.0" } ] } }, { "product_name": "Symphony Plus S+ Operations", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "3", "version_value": "3.2" } ] } }, { "product_name": "Symphony Plus S+ Engineering ", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "1.1", "version_value": "2.2" } ] } }, { "product_name": "Composer Harmony", "version": { "version_data": [ { "version_affected": "=", "version_value": "5.1" }, { "version_affected": "=", "version_value": "6.0" }, { "version_affected": "=", "version_value": "6.1" } ] } }, { "product_name": "Composer Melody ", "version": { "version_data": [ { "version_affected": "=", "version_value": "5.3" }, { "version_affected": "\u003c=", "version_name": "6", "version_value": "6.3" } ] } }, { "product_name": "Harmony OPC Server Standalone", "version": { "version_data": [ { "version_affected": "=", "version_value": "6.0" }, { "version_affected": "=", "version_value": "6.1" }, { "version_affected": "=", "version_value": "7.0" } ] } }, { "product_name": "Advant OCS Control Builder A", "version": { "version_data": [ { "version_affected": "=", "version_value": "1.3" }, { "version_affected": "=", "version_value": "1.4" } ] } }, { "product_name": "Composer CTK", "version": { "version_data": [ { "version_affected": "=", "version_value": "6.1" }, { "version_affected": "=", "version_value": "6.2" } ] } }, { "product_name": "AdvaBuild", "version": { "version_data": [ { "version_affected": "=", "version_value": "3.7 SP1" }, { "version_affected": "=", "version_value": "3.7 SP2" } ] } }, { "product_name": "OPC Server for Mod 300 (non-800xA)", "version": { "version_data": [ { "version_affected": "=", "version_value": "1.4" } ] } }, { "product_name": "OPC Data Link", "version": { "version_data": [ { "version_affected": "=", "version_value": "2.1" }, { "version_affected": "=", "version_value": "2.2" } ] } }, { "product_name": "Knowledge Manager", "version": { "version_data": [ { "version_affected": "=", "version_value": "8.0" }, { "version_affected": "=", "version_value": "9.0" }, { "version_affected": "=", "version_value": "9.1" } ] } }, { "product_name": "Manufacturing Operations Management", "version": { "version_data": [ { "version_affected": "=", "version_value": "1812" }, { "version_affected": "=", "version_value": "1909" } ] } }, { "product_name": "Advant OCS AC 100 OPS Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "5.1" }, { "version_affected": "=", "version_value": "6.0" }, { "version_affected": "=", "version_value": "6.1" } ] } } ] }, "vendor_name": "ABB" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "For ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200 Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "source": { "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2020-8481", "datePublished": "2020-04-29T01:30:56", "dateReserved": "2020-01-30T00:00:00", "dateUpdated": "2024-08-04T10:03:45.868Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-8481\",\"sourceIdentifier\":\"cybersecurity@ch.abb.com\",\"published\":\"2020-04-29T02:15:11.907\",\"lastModified\":\"2021-09-14T14:00:32.383\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"For ABB products ABB Ability\u2122 System 800xA and related system extensions versions 5.1, 6.0 and 6.1, Compact HMI versions 5.1 and 6.0, Control Builder Safe 1.0, 1.1 and 2.0, Symphony Plus -S+ Operations 3.0 to 3.2 Symphony Plus -S+ Engineering 1.1 to 2.2, Composer Harmony 5.1, 6.0 and 6.1, Melody Composer 5.3, 6.1/6.2 and SPE for Melody 1.0SPx (Composer 6.3), Harmony OPC Server (HAOPC) Standalone 6.0, 6.1 and 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A 1.3 and 1.4, Advant\u00ae OCS AC100 OPC Server 5.1, 6.0 and 6.1, Composer CTK 6.1 and 6.2, AdvaBuild 3.7 SP1 and SP2, OPCServer for MOD 300 (non-800xA) 1.4, OPC Data Link 2.1 and 2.2, Knowledge Manager 8.0, 9.0 and 9.1, Manufacturing Operations Management 1812 and 1909, confidential data is written in an unprotected file. An attacker who successfully exploited this vulnerability could take full control of the computer.\"},{\"lang\":\"es\",\"value\":\"Para los productos ABB Ability\u2122 System 800xA de ABB y extensiones de sistema relacionadas versiones 5.1, 6.0 y 6.1, Compact HMI versiones 5.1 y 6.0, Control Builder Safe versiones 1.0, 1.1 y 2.0, Symphony Plus -S+ Engineering versiones 1.1 hasta 2.2, Composer Harmony versiones 5.1, 6.0 y 6.1, Melody Composer versiones 5.3, 6.1/6.2 y SPE for Melody versi\u00f3n 1.0SPx (Composer versi\u00f3n 6.3), Harmony OPC Server (HAOPC) Standalone versiones 6.0, 6.1 y 7.0, ABB Ability\u2122 System 800xA/ Advant\u00ae OCS Control Builder A versiones 1.3 y 1.4, Advant\u00ae OCS AC100 OPC Server versiones 5.1, 6.0 y 6.1, Composer CTK versiones 6.1 y 6.2, AdvaBuild versiones 3.7 SP1 y SP2, OPCServer para MOD 300 (non-800xA) versi\u00f3n 1.4, OPC Data Link versiones 2.1 y 2.2, Knowledge Manager versiones 8.0, 9.0 y 9.1, Manufacturing Operations Management versiones 1812 y 1909, los datos confidenciales se escriben en un archivo no protegido. Un atacante que explote con \u00e9xito esta vulnerabilidad podr\u00eda tomar el control total de la computadora.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":10.0},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-922\"}]},{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:abb:800xa_system:5.1:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"342DDBC9-9FD6-4B34-AE9D-570173A28ECE\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121230\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=2PAA121231\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.