CVE-2021-22288 (GCVE-0-2021-22288)

Vulnerability from cvelistv5 – Published: 2022-02-04 22:29 – Updated: 2024-09-17 04:04
VLAI?
Title
SECURITY – Denial of Service Vulnerabilities in SPIET800 INFI-Net to Ethernet Transfer module and PNI800 S+ Ethernet communication interface module
Summary
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.
CWE
  • CWE-20 - Improper Input Validation
Assigner
ABB
References
Impacted products
Vendor Product Version
ABB SPIET800 Affected: unspecified , ≤ A_B (custom)
Create a notification for this product.
    ABB PNI800 Affected: unspecified , ≤ A_B (custom)
Create a notification for this product.
Credits
ABB thanks Lance Lamont from Verve Industrial Protection and Ron Brash from Verve Industrial Protection/aDolus Technology Inc. helping to identify the vulnerabilities and protecting our customers.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:37:18.446Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SPIET800",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "A_B",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PNI800",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "A_B",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "ABB thanks Lance Lamont from Verve Industrial Protection and Ron Brash from Verve Industrial Protection/aDolus Technology Inc. helping to identify the vulnerabilities and protecting our customers."
        }
      ],
      "datePublic": "2022-02-02T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-04T22:29:18",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "ABB advises all customers to review their installations to determine if they are using an impacted product as listed above.\n\u2013 SPIET800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version A_C or later.\n\u2013 PNI800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version B_0 or later."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "SECURITY \u2013 Denial of Service Vulnerabilities in SPIET800 INFI-Net to Ethernet Transfer module and PNI800 S+ Ethernet communication interface module",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@ch.abb.com",
          "DATE_PUBLIC": "2022-02-02T13:47:00.000Z",
          "ID": "CVE-2021-22288",
          "STATE": "PUBLIC",
          "TITLE": "SECURITY \u2013 Denial of Service Vulnerabilities in SPIET800 INFI-Net to Ethernet Transfer module and PNI800 S+ Ethernet communication interface module"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SPIET800",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "A_B"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PNI800",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "A_B"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ABB"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "ABB thanks Lance Lamont from Verve Industrial Protection and Ron Brash from Verve Industrial Protection/aDolus Technology Inc. helping to identify the vulnerabilities and protecting our customers."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "ABB advises all customers to review their installations to determine if they are using an impacted product as listed above.\n\u2013 SPIET800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version A_C or later.\n\u2013 PNI800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version B_0 or later."
          }
        ],
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2021-22288",
    "datePublished": "2022-02-04T22:29:18.996984Z",
    "dateReserved": "2021-01-05T00:00:00",
    "dateUpdated": "2024-09-17T04:04:28.914Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:pni800_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"a_b\", \"matchCriteriaId\": \"FE579964-A7CB-4778-A9D7-657AA5317767\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:pni800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9ED6943A-99B4-42A7-88FC-F0061E9FD79E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:abb:spiet800_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"a_b\", \"matchCriteriaId\": \"6F929906-457E-44D2-BCE7-A833135B650D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:abb:spiet800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6E936B7F-C090-47A4-B74B-5418A2678782\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.\"}, {\"lang\": \"es\", \"value\": \"Una vulnerabilidad de Comprobaci\\u00f3n de Entrada Inapropiada en el m\\u00f3dulo ABB SPIET800 y PNI800 permite a un atacante causar la denegaci\\u00f3n de servicio o causar que el m\\u00f3dulo no responda\"}]",
      "id": "CVE-2021-22288",
      "lastModified": "2024-11-21T05:49:51.150",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@ch.abb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2022-02-04T23:15:11.027",
      "references": "[{\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"cybersecurity@ch.abb.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cybersecurity@ch.abb.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"cybersecurity@ch.abb.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-22288\",\"sourceIdentifier\":\"cybersecurity@ch.abb.com\",\"published\":\"2022-02-04T23:15:11.027\",\"lastModified\":\"2024-11-21T05:49:51.150\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de Comprobaci\u00f3n de Entrada Inapropiada en el m\u00f3dulo ABB SPIET800 y PNI800 permite a un atacante causar la denegaci\u00f3n de servicio o causar que el m\u00f3dulo no responda\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cybersecurity@ch.abb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:pni800_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"a_b\",\"matchCriteriaId\":\"FE579964-A7CB-4778-A9D7-657AA5317767\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:pni800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9ED6943A-99B4-42A7-88FC-F0061E9FD79E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:abb:spiet800_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"a_b\",\"matchCriteriaId\":\"6F929906-457E-44D2-BCE7-A833135B650D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:abb:spiet800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E936B7F-C090-47A4-B74B-5418A2678782\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@ch.abb.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…