CVE-2021-23852 (GCVE-0-2021-23852)

Vulnerability from cvelistv5 – Published: 2021-06-09 14:18 – Updated: 2024-09-16 22:03
VLAI?
Summary
An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS).
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
References
Impacted products
Vendor Product Version
Bosch CPP Firmware Affected: all
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.365Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "CPP4, CPP6, CPP7, CPP7.3, CPP13"
          ],
          "product": "CPP Firmware",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2021-05-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-09T14:18:24",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-478243-BT",
        "discovery": "UNKNOWN"
      },
      "title": "Denial of Service (DoS) due to invalid web parameter",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2021-05-20",
          "ID": "CVE-2021-23852",
          "STATE": "PUBLIC",
          "TITLE": "Denial of Service (DoS) due to invalid web parameter"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CPP Firmware",
                      "version": {
                        "version_data": [
                          {
                            "platform": "CPP4, CPP6, CPP7, CPP7.3, CPP13",
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS)."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-478243-BT",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23852",
    "datePublished": "2021-06-09T14:18:24.707515Z",
    "dateReserved": "2021-01-12T00:00:00",
    "dateUpdated": "2024-09-16T22:03:24.110Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:cpp4_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"55C25C73-B8DF-4530-B59A-375AE426D2D8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:cpp4:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1F4FA4F9-6BDC-44C4-A151-16ECF7926A83\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:cpp6_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2549BED9-6769-41AB-BE24-190ED45BC3C7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:cpp6:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"27B65C05-69F5-4048-BCBE-DA0D53EF9AFE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:cpp7_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"85D3F004-3A77-4C40-9921-B775BC487B56\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:cpp7:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E8339008-8889-47B0-9416-CCC6CE75D277\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:cpp7.3_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A028085E-993B-4BE2-A88A-E89AAFAE905E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:cpp7.3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5B97B95A-8143-4766-9F10-87E19AED22C6\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:cpp13_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4600022D-EDD1-43D2-8098-A863A1A23821\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:cpp13:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"80149FF9-3C6D-4C80-8257-CEB2BE8B0DCA\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS).\"}, {\"lang\": \"es\", \"value\": \"Un atacante autenticado con derechos de administrador de las c\\u00e1maras Bosch IP pueden llamar a una URL con un par\\u00e1metro invalid que causa que la c\\u00e1mara deje de responder durante unos segundos y causa una Denegaci\\u00f3n de servicio (DoS)\"}]",
      "id": "CVE-2021-23852",
      "lastModified": "2024-11-21T05:51:57.013",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 4.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 4.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:N/I:N/A:P\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-06-09T15:15:08.310",
      "references": "[{\"url\": \"https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html\", \"source\": \"psirt@bosch.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "psirt@bosch.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2021-23852\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2021-06-09T15:15:08.310\",\"lastModified\":\"2024-11-21T05:51:57.013\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An authenticated attacker with administrator rights Bosch IP cameras can call an URL with an invalid parameter that causes the camera to become unresponsive for a few seconds and cause a Denial of Service (DoS).\"},{\"lang\":\"es\",\"value\":\"Un atacante autenticado con derechos de administrador de las c\u00e1maras Bosch IP pueden llamar a una URL con un par\u00e1metro invalid que causa que la c\u00e1mara deje de responder durante unos segundos y causa una Denegaci\u00f3n de servicio (DoS)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":4.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:N/I:N/A:P\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:cpp4_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"55C25C73-B8DF-4530-B59A-375AE426D2D8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:cpp4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F4FA4F9-6BDC-44C4-A151-16ECF7926A83\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:cpp6_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2549BED9-6769-41AB-BE24-190ED45BC3C7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:cpp6:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"27B65C05-69F5-4048-BCBE-DA0D53EF9AFE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:cpp7_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85D3F004-3A77-4C40-9921-B775BC487B56\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:cpp7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8339008-8889-47B0-9416-CCC6CE75D277\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:cpp7.3_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A028085E-993B-4BE2-A88A-E89AAFAE905E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:cpp7.3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5B97B95A-8143-4766-9F10-87E19AED22C6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:cpp13_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4600022D-EDD1-43D2-8098-A863A1A23821\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:cpp13:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80149FF9-3C6D-4C80-8257-CEB2BE8B0DCA\"}]}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html\",\"source\":\"psirt@bosch.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://psirt.bosch.com/security-advisories/bosch-sa-478243-bt.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…