CVE-2021-23880 (GCVE-0-2021-23880)
Vulnerability from cvelistv5 – Published: 2021-02-10 09:15 – Updated: 2024-09-16 22:45
VLAI?
Summary
Improper Access Control in attribute in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows authenticated local administrator user to perform an uninstallation of the anti-malware engine via the running of a specific command with the correct parameters.
Severity ?
6.7 (Medium)
CWE
- CWE-269 - Improper Privilege Management
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| McAfee LLC | Endpoint Security (ENS) for Windows |
Affected:
10.7.x , < 10.7.0 February 2021
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T19:14:09.256Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Endpoint Security (ENS) for Windows",
"vendor": "McAfee LLC",
"versions": [
{
"lessThan": "10.7.0 February 2021",
"status": "affected",
"version": "10.7.x",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-02-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Improper Access Control in attribute in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows authenticated local administrator user to perform an uninstallation of the anti-malware engine via the running of a specific command with the correct parameters."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-10T09:15:17",
"orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"shortName": "trellix"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Improper Access Control in the ENS installer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@mcafee.com",
"DATE_PUBLIC": "2021-02-10T00:00:00.000Z",
"ID": "CVE-2021-23880",
"STATE": "PUBLIC",
"TITLE": "Improper Access Control in the ENS installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Endpoint Security (ENS) for Windows",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "10.7.x",
"version_value": "10.7.0 February 2021"
}
]
}
}
]
},
"vendor_name": "McAfee LLC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Access Control in attribute in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows authenticated local administrator user to perform an uninstallation of the anti-malware engine via the running of a specific command with the correct parameters."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345",
"refsource": "CONFIRM",
"url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345"
}
]
},
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
"assignerShortName": "trellix",
"cveId": "CVE-2021-23880",
"datePublished": "2021-02-10T09:15:17.543955Z",
"dateReserved": "2021-01-12T00:00:00",
"dateUpdated": "2024-09-16T22:45:07.753Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mcafee:endpoint_security:*:*:*:*:*:windows:*:*\", \"versionEndExcluding\": \"10.7.0\", \"matchCriteriaId\": \"CA4CEE25-A297-4D69-8CF8-5425875B206A\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Improper Access Control in attribute in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows authenticated local administrator user to perform an uninstallation of the anti-malware engine via the running of a specific command with the correct parameters.\"}, {\"lang\": \"es\", \"value\": \"Un Control de Acceso Inapropiado en attribute en McAfee Endpoint Security (ENS) para Windows versiones anteriores a 10.7.0 actualizaci\\u00f3n de Febrero de 2021, permite a un usuario administrador local autenticado llevar a cabo una desinstalaci\\u00f3n del motor anti-malware por medio de la ejecuci\\u00f3n de un comando espec\\u00edfico con los par\\u00e1metros correctos\"}]",
"id": "CVE-2021-23880",
"lastModified": "2024-11-21T05:51:59.600",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 4.4, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 2.1, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 3.9, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-02-10T10:15:13.177",
"references": "[{\"url\": \"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\", \"source\": \"trellixpsirt@trellix.com\", \"tags\": [\"Broken Link\", \"Vendor Advisory\"]}, {\"url\": \"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "trellixpsirt@trellix.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"trellixpsirt@trellix.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-23880\",\"sourceIdentifier\":\"trellixpsirt@trellix.com\",\"published\":\"2021-02-10T10:15:13.177\",\"lastModified\":\"2024-11-21T05:51:59.600\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Access Control in attribute in McAfee Endpoint Security (ENS) for Windows prior to 10.7.0 February 2021 Update allows authenticated local administrator user to perform an uninstallation of the anti-malware engine via the running of a specific command with the correct parameters.\"},{\"lang\":\"es\",\"value\":\"Un Control de Acceso Inapropiado en attribute en McAfee Endpoint Security (ENS) para Windows versiones anteriores a 10.7.0 actualizaci\u00f3n de Febrero de 2021, permite a un usuario administrador local autenticado llevar a cabo una desinstalaci\u00f3n del motor anti-malware por medio de la ejecuci\u00f3n de un comando espec\u00edfico con los par\u00e1metros correctos\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":2.1,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"trellixpsirt@trellix.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mcafee:endpoint_security:*:*:*:*:*:windows:*:*\",\"versionEndExcluding\":\"10.7.0\",\"matchCriteriaId\":\"CA4CEE25-A297-4D69-8CF8-5425875B206A\"}]}]}],\"references\":[{\"url\":\"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\",\"source\":\"trellixpsirt@trellix.com\",\"tags\":[\"Broken Link\",\"Vendor Advisory\"]},{\"url\":\"https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10345\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…